Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BERYLLIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Quadrupole and multi-collector ICP-MS analysis of 226 Ra in brain from a radium dial painter

We report two ICP-MS methods were developed to measure the radiotoxic isotope 226 Ra in brain tissues from a radium dial painter worker. The first method was a direct analysis of acid digested samples using quadrupole ICP-MS. The instrumental LOD of 226 Ra was 0.1 ng kg -1 . Polyatomic interferences at m/z 226 were investigated and Pb was identified from a polyatomic interferent in an in-house sample prepared from bovine brain, with a 226/208 formation ratio of 4 × 10 -8 . The quadrupole ICP-MS method was also used to measure levels of beryllium, strontium, and uranium. A second method was developed that included cation-exchange chromatography to separate 226 Ra followed by analysis with sector field MC-ICP-MS. The instrumental LOD for the cation exchange method with MC-ICP-MS detection was 0.5 pg kg -1 (19 mBq kg -1 ). The measured concentrations of 226 Ra in different brain regions ranged from 0.09–0.72 ng kg -1 (3.3–27 Bq kg -1 ) and radium was non-uniformly distributed in the brain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapidly convergent quantum Monte Carlo using a Chebyshev projector

The multireference coupled-cluster Monte Carlo (MR-CCMC) algorithm is a determinant-based quantum Monte Carlo (QMC) algorithm that is conceptually similar to Full Configuration Interaction QMC (FCIQMC). It has been shown to offer a balanced treatment of both static and dynamic correlation while retaining polynomial scaling, although application to large systems with significant strong correlation remained impractical. In this paper, we document recent algorithmic advances that enable rapid convergence and a more black-box approach to the multireference problem. These include a logarithmically scaling metric-tree-based excitation acceptance algorithm to search for determinants connected to the reference space at the desired excitation level and a symmetry-screening procedure for the reference space. We show that, for moderately sized reference spaces, the new search algorithm brings about an approximately 8-fold acceleration of one MR-CCMC iteration, while the symmetry screening procedure reduces the number of active reference space determinants with essentially no loss of accuracy. We also introduce a stochastic implementation of an approximate wall projector, which is the infinite imaginary time limit of the exponential projector, using a truncated expansion of the wall function in Chebyshev polynomials. Notably, this wall-Chebyshev projector can be used to accelerate any projector-based QMC algorithm. We show that it requires significantly fewer applications of the Hamiltonian to achieve the same statistical convergence. We benchmark these acceleration methods on the beryllium and carbon dimers, using initiator FCIQMC and MR-CCMC with basis sets up to cc-pVQZ quality.

Zhao, Zijun↗

Application-specific machine-learned interatomic potentials: exploring the trade-off between DFT convergence, MLIP expressivity, and computational cost

Machine-learned interatomic potentials (MLIPs) are revolutionizing computational materials science and chemistry by offering an efficient alternative to ab initio molecular dynamics (MD) simulations. However, fitting high-quality MLIPs remains a challenging, time-consuming, and computationally intensive task where numerous trade-offs have to be considered, e.g., How much and what kind of atomic configurations should be included in the training set? Which level of ab initio convergence should be used to generate the training set? Which loss function should be used for fitting the MLIP? Which machine learning architecture should be used to train the MLIP? The answers to these questions significantly impact both the computational cost of MLIP training and the accuracy and computational cost of subsequent MLIP MD simulations. In this study, we use a configurationally diverse beryllium dataset and quadratic spectral neighbor analysis potential. We demonstrate that joint optimization of energy versus force weights, training set selection strategies, and convergence settings of the ab initio reference simulations, as well as model complexity can lead to a significant reduction in the overall computational cost associated with training and evaluating MLIPs. This opens the door to computationally efficient generation of high-quality MLIPs for a range of applications which demand different accuracy versus training and evaluation cost trade-offs.

36 MATERIALS SCIENCE↗

Optimizing the XMaS Beamline for Low energy Operations to Maximize Benefits from the ESRF Upgrade Program

The XMaS beamline at the ESRF has been in regular user operation since April 1998 and operates over an energy range of 2.4-15 keV. It has developed a wide range of unique instrumentation, primarily dedicated to high resolution magnetic and single crystal diffraction. With the upcoming ESRF upgrade program a number of instrumental developments are planned for the beamline to maximize the benefits of the increased photon flux at low energies. Firstly we report on the optimisation of the beamline and its core components. A novel attenuator system which is actuated by fast acting solenoids thereby avoiding problems of gas bursts into the beamline vacuum seen on some commercially available instruments is introduced. Secondly we discuss developments to the low temperature sample environments that have been integrated into the beamline vacuum system, minimizing both air and beryllium absorption. Finally we demonstrate the current capabilities of the beamline by describing preliminary reflectivity measurements that have been made on an [Fe(2ML)Pd(15ML)]x20 multilayer recorded around the Pd L{sub 3} edge using circular polarised light produced from a thin diamond phase plate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion cyclotron resonance frequency heating in JET during initial operations with the ITER-like wall

In 2011/12, JET started operation with its new ITER-Like Wall (ILW) made of a tungsten (W) divertor and a beryllium (Be) main chamber wall. The impact of the new wall materials on the JET Ion Cyclotron Resonance Frequency (ICRF) operation is assessed and some important properties of JET plasmas heated with ICRF are highlighted. A ∼ 20% reduction of the antenna coupling resistance is observed with the ILW as compared with the JET carbon (JET-C) wall. Heat-fluxes on the protecting limiters close the antennas, quantified using Infra-Red thermography (maximum 4.5 MW/m{sup 2} in current drive phasing), are within the wall power load handling capabilities. A simple RF sheath rectification model using the antenna near-fields calculated with the TOPICA code can reproduce the heat-flux pattern around the antennas. ICRF heating results in larger tungsten and nickel (Ni) contents in the plasma and in a larger core radiation when compared to Neutral Beam Injection (NBI) heating. The location of the tungsten ICRF specific source could not be identified but some experimental observations indicate that main-chamber W components could be an important impurity source: for example, the divertor W influx deduced from spectroscopy is comparable when using RF or NBI at same power and comparable divertor conditions, and Be evaporation in the main chamber results in a strong reduction of the impurity level. In L-mode plasmas, the ICRF specific high-Z impurity content decreased when operating at higher plasma density and when increasing the hydrogen concentration from 5% to 15%. Despite the higher plasma bulk radiation, ICRF exhibited overall good plasma heating performance; the power is typically deposited at the plasma centre while the radiation is mainly from the outer part of the plasma bulk. Application of ICRF heating in H-mode plasmas has started, and the beneficial effect of ICRF central electron heating to prevent W accumulation in the plasma core has been observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Electrochemical cell for in operando X-ray diffraction measurements on a conventional X-ray diffractometer

Electrochemical in operando X-ray diffraction (XRD) is a powerful method to analyze structural changes of energy storage materials while inserting/de-inserting charge carriers, such as Li- or Na-ions, into/from a host structure. The design of an XRD in operando cell is presented, which enables the use of thin (6 μm) aluminum foil as X-ray window as a non-toxic alternative to conventional beryllium windows. Owing to the reduced thickness, diffraction patterns and their changes during cycling can be observed with excellent quality, which was demonstrated for two cathode materials for sodium-ion batteries in a half-cell set-up, P2-Na{sub 0.7}MnO{sub 2} and Na{sub 2.55}V{sub 6}O{sub 16} ⋅ 0.6H{sub 2}O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decomposition of the configuration-interaction coefficients in the multiconfiguration time-dependent Hartree-Fock method

An approximate implementation of the multiconfiguration time-dependent Hartree-Fock method is proposed, in which the matrix of configuration-interaction coefficients is decomposed into a product of matrices of smaller dimension. The applicability of this method in which all the configurations are kept in the expansion of the wave function, while the configuration-interaction coefficients are approximately calculated, is discussed by showing the results on three model systems: a one-dimensional model of a beryllium atom, a one-dimensional model of a carbon atom, and a one-dimensional model of a chain of four hydrogen atoms. The time-dependent electronic dynamics induced by a few-cycle, long-wavelength laser pulse is found to be well described at a lower computational cost compared to the standard multiconfiguration time-dependent Hartree-Fock treatment. Drawbacks of the method are also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-vacuum multi-modal monochromator for synchrotron-based hard x-ray micro-imaging

The original monochromator design we present consists in a high-vacuum vessel comprising three monochromators mounted side-by-side: a Lauë/Lauë, a Bragg/Bragg, and a double-multilayer monochromator. The selection of one monochromator type is done remotely by sliding laterally the crystal support in the monochromator vessel. In this way, exotic combinations such as Lauë/Bragg are also possible. Installation and commissioning of the new monochromator at ESRF beamline ID19 was carried out 2013-2014 (the multilayers not being installed yet). Beamline ID19 offers not only superb beam characteristics for phase-contrast imaging with a high level of sensitivity but also compared to other synchrotron X-ray imaging facilities a large beam of currently up to 7 cm × 1.3 cm. A wide energy range can be accessed in a fixed-exit mode (depending on the optics chosen the accessible energy range is between 10 keV and 200 keV). A beryllium exit window (10 cm × 10 cm active opening) completes the monochromator assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron imaging with the short-pulse laser driven neutron source at the TRIDENT Laser Facility

Emerging approaches to short-pulse laser-driven neutron production offer a possible gateway to compact, low cost, and intense broad spectrum sources for a wide variety of applications. They are based on energetic ions, driven by an intense short-pulse laser, interacting with a converter material to produce neutrons via breakup and nuclear reactions. Recent experiments performed with the high-contrast laser at the Trident laser facility of Los Alamos National Laboratory have demonstrated a laser-driven ion acceleration mechanism operating in the regime of relativistic transparency, featuring a volumetric laser-plasma interaction. This mechanism is distinct from previously studied ones that accelerate ions at the laser-target surface. The Trident experiments produced an intense beam of deuterons with an energy distribution extending above 100 MeV. This deuteron beam, when directed at a beryllium converter, produces a forward-directed neutron beam with ~5x10 9 n/sr, in a single laser shot, primarily due to deuteron breakup. The neutron beam has a pulse duration on the order of a few nanoseconds with an energy distribution extending from a few hundreds of keV to almost 80 MeV. For the experiments on neutron-source spot-size measurements, our gated neutron imager was setup to select neutrons in the energy range of 2.5 to 35 MeV. The spot size of neutron emission at the converter was measured by two different imaging techniques, using a knife-edge and a penumbral aperture, in two different experimental campaigns. The neutron-source spot size is measured ~1 mm for both experiments. The measurements and analysis reported here give a spatial characterization for this type of neutron source for the first time. In addition, the forward modeling performed provides an empirical estimate of the spatial characteristics of the deuteron ion-beam. Finally, these experimental observations, taken together, provide essential yet unique data to benchmark and verify theoretical work into the basic acceleration mechanism, which remains an ongoing challenge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulations of the ablative Rayleigh-Taylor instability in planar inertial-confinement-fusion targets using the FastRad3D code

The ablative Rayleigh-Taylor (RT) instability is a central issue in the performance of laser-accelerated inertial-confinement-fusion targets. Historically, the accurate numerical simulation of this instability has been a challenging task for many radiation hydrodynamics codes, particularly when it comes to capturing the ablatively stabilized region of the linear dispersion spectrum and modeling ab initio perturbations. Here, we present recent results from two-dimensional numerical simulations of the ablative RT instability in planar laser-ablated foils that were performed using the Eulerian code FastRad3D. Our study considers polystyrene, (cryogenic) deuterium-tritium, and beryllium target materials, quarter- and third-micron laser light, and low and high laser intensities. An initial single-mode surface perturbation is modeled in our simulations as a small modulation to the target mass density and the ablative RT growth-rate is calculated from the time history of areal-mass variations once the target reaches a steady-state acceleration. By performing a sequence of such simulations with different perturbation wavelengths, we generate a discrete dispersion spectrum for each of our examples and find that in all cases the linear RT growth-rate γ is well described by an expression of the form γ=α [kg/(1+ϵ kLm)]1/2−βkVa, where k is the perturbation wavenumber, g is the acceleration of the target, Lm is the minimum density scale-length, Va is the ablation velocity, and ϵ is either one or zero. The dimensionless coefficients α and β in the above formula depend on the particular target and laser parameters and are determined from two-dimensional simulation results through the use of a nonlinear curve-fitting procedure. While our findings are generally consistent with those of Betti et al. (Phys. Plasmas 5, 1446 (1998)), the ablative RT growth-rates predicted in this investigation are somewhat smaller than the values previously reported for the same target and laser parameters. It is speculated that differences in the equation-of-state and opacity models are largely responsible for the discrepancy. Resolution of this issue awaits the development of better experimental diagnostics capable of measuring small-wavelength (5–20 μm) perturbation growth due to the ablative RT instability in the linear regime.

Bates, J. W. (ORCID:0000000188087240)↗

Radiative detached divertor with acceptable separatrix Z eff

The feasibility study is performed for the radiative detached divertor (RDD) concept, which characterizes a variety of detached plasmas with impurity amounts providing the highest levels of divertor radiation without X-point MARFE (XPM), based on a set of restrictive criteria for the leading plasma parameters (LPPs) including, e.g., tolerable peak power loads below 1 MW/m2, low separatrix densities, allowable impurity concentrations, and acceptable Z eff values for a DIII-D like tokamak. For this, extensive simulations with the 2-D edge plasma transport code were done scanning the deuterium and impurity inventories practically for all impurity elements from beryllium to neon and the analysis of LPP variations in these scans is presented. It is shown that, for a given D inventory, the total radiation fraction with an increase in the impurity inventory reaches a flat top level, f rad = 0.85 ± 0.01, whereas the higher f rad corresponds to XPM. This critical fraction is the same for all elements and values of the D inventory. Successful RDD solutions with a flat top radiation meeting all ad hoc LPP criteria are found for some elements. Boron and nitrogen are shown to be the most promising elements for seeding, since they are capable of providing alone the successful RDD at the lowest concentrations. Several important effects on impurity radiation are considered including: cross-field impurity transport in regions with strong temperature gradients, multi-species thermal force, charge-exchange of impurity ions with D atoms originating from recombination, impurity entrainment by parallel flows, flows caused by inner/outer divertor asymmetries, and Mach ∼ 1 flows reached inside radiation-ionization fronts. The impurity radiation profiles of various elements are analyzed suggesting three patterns differing in the radiation front position with respect to the D ionization source. The modeled relocation of D from the pedestal into divertor regions; an enhanced pedestal enrichment for impurities with high first ionization potential; and RDD capability of confining inside the divertors the large D inventories as neutral atoms, are considered as effects of increasing impurity inventory. The responses of a flat-top RDD to the input parameters variation are studied. For example, dependencies of LPPs on the input power increase, which express the sharp and even bifurcation transitions between two distinct branches corresponding to the detached and attached divertors, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 7.2 keV spherical x-ray crystal backlighter for two-frame, two-color backlighting at Sandia’s Z Pulsed Power Facility

Many experiments on Sandia National Laboratories’ Z Pulsed Power Facility—a 30 MA, 100 ns rise-time, pulsed-power driver—use a monochromatic quartz crystal backlighter system at 1.865 keV (Si He α ) or 6.151 keV (Mn He α ) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array z-pinch. The x-ray source is generated by the Z-Beamlet laser, which provides two 527-nm, 1 kJ, 1-ns laser pulses. Radiographs of imploding, thick-walled beryllium liners at convergence ratios C R above 15 [C R =r i (0)/r i (t)] using the 6.151-keV backlighter system were too opaque to identify the inner radius ri of the liner with high confidence, demonstrating the need for a higher-energy x-ray radiography system. Here, we present a 7.242 keV backlighter system using a Ge(335) spherical crystal with the Co He α resonance line. This system operates at a similar Bragg angle as the existing 1.865 keV and 6.151 keV backlighters, enhancing our capabilities for two-color, two-frame radiography without modifying the system integration at Z. The first data taken at Z include 6.2-keV and 7.2-keV two-color radiographs as well as radiographs of low-convergence (C R about 4-5), high-areal-density liner implosions.

36 MATERIALS SCIENCE↗

Intense, directed neutron beams from a laser-driven neutron source at PHELIX

Laser-driven neutrons are generated by the conversion of laser-accelerated ions via nuclear reactions inside a converter material. Here, we present results from an experimental campaign at the PHELIX laser at GSI in Darmstadt where protons and deuterons were accelerated from thin deuterated plastic foils with thicknesses in the μm and sub-μm range. The neutrons were generated inside a sandwich-type beryllium converter, leading to reproducible neutron numbers around 10 11 neutrons per shot. The angular distribution was measured with a high level of detail using up to 30 bubble detectors simultaneously. It shows a laser forward directed component of up to 1.42 × 10 10 neutrons per steradian, corresponding to a dose of 43 mrem scaled to a distance of 1 m from the converter.

07 ISOTOPE AND RADIATION SOURCES↗

Fluorescence and absorption spectroscopy for warm dense matter studies and ICF plasma diagnostics

The burning core of an inertial confinement fusion (ICF) plasma produces bright x-rays at stagnation that can directly diagnose core conditions essential for comparison to simulations and understanding fusion yields. These x-rays also backlight the surrounding shell of warm, dense matter, whose properties are critical to understanding the efficacy of the inertial confinement and global morphology. In this work, we show that the absorption and fluorescence spectra of mid-Z impurities or dopants in the warm dense shell can reveal the optical depth, temperature, and density of the shell and help constrain models of warm, dense matter. This is illustrated by the example of a high-resolution spectrum collected from an ICF plasma with a beryllium shell containing native iron impurities. Lastly, analysis of the iron K-edge provides model-independent diagnostics of the shell density (2.3 × 10 24 e/cm 3 ) and temperature (10 eV), while a 12-eV red shift in Kβ and 5-eV blue shift in the K-edge discriminate among models of warm dense matter: Both shifts are well described by a self-consistent field model based on density functional theory but are not fully consistent with isolated-atom models using ad-hoc density effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next-generation diamond cell and applications to single-crystal neutron diffraction

In this paper, a diamond cell optimized for single-crystal neutron diffraction is described. It is adapted for work at several of the single-crystal diffractometers of the Spallation Neutron Source and the High Flux Isotope Reactor at the Oak Ridge National Laboratory (ORNL). A simple spring design improves portability across the facilities and affords load maintenance from offline pressurization and during temperature cycling. Compared to earlier prototypes, pressure stability of polycrystalline diamond (Versimax®) has been increased through double-conical designs and ease of use has been improved through changes to seat and piston setups. These anvils allow ~30%-40% taller samples than possible with comparable single-crystal anvils. Hydrostaticity and the important absence of shear pressure gradients have been established with the use of glycerin as a pressure medium. Large single-crystal synthetic diamonds have also been used for the first time with such a clamp-diamond anvil cell for pressures close to 20 GPa. The cell is made from a copper beryllium alloy and sized to fit into ORNL’s magnets for future ultra-low temperature and high-field studies. Finally, we show examples from the Spallation Neutron Source’s SNAP and CORELLI beamlines and the High Flux Isotope Reactor’s HB-3A and IMAGINE beamlines.

36 MATERIALS SCIENCE↗

Using L-shell x-ray spectra to determine conditions of non-local thermal dynamic equilibrium plasmas

K-shell x-ray spectra of Li- to H-like ions have long been used to determine plasma conditions. The ratio of integrated line intensities is used to determine the temperature. At the density of non-local thermal dynamic equilibrium (NLTE) plasmas (ne ≈ 10 21 cm -3 ), the K-shell spectrum is not very sensitive to density. We propose using the L-shell emission of open L-shell ions (C- to Li-like) as an alternative to determine both temperature and density of NLTE plasmas. First, the L-shell models of a mid-Z material need to be verified against the temperatures obtained using a K-shell spectrum of a low-Z material. A buried layer platform is being developed at the OMEGA laser to study the open L-shell spectra of NLTE plasmas of mid-Z materials. Studies have been done using a 250 μm diameter dot composed of a layer of 1200 Å thick Zn between two 600 Å thick layers of Ti, in the center of a 1000 μm diameter, 13 μm thick beryllium tamper. Lasers heat the target from both sides for up to 3 ns. The size of the emitting volume vs time was measured with x-ray imaging (face-on and side-on) to determine the density. The temperature was measured from the Ti K-shell spectra. The use of this platform for the verification of atomic L-shell models is discussed.

36 MATERIALS SCIENCE↗

Determination of 2D poloidal maps of the intrinsic W density for transport studies in JET-ILW

The experimental method developed at ASDEX Upgrade for the determination of the intrinsic tungsten (W) density profile coupling data from the soft X-ray (SXR) diagnostic and vacuum-ultra-violet (VUV) spectroscopy has been upgraded for application to JET plasmas. The strong poloidal asymmetries in the SXR emission are modeled assuming a ln ln ( ϵ ( ρ , R ) / ϵ ( ρ , R 0 ) ) = λ ( ρ ) ( R 2 − R 0 2 ) distribution, where ρ is the flux coordinate, R is the major radius, and λ is the fit parameter. The W density is calculated from the resulting 2D SXR emissivity maps accounting for contributions from a low-Z impurity (typically beryllium) and main ion with the assumption that their contributions are poloidally symmetric. Comparing the result with the independent W concentration measurement of VUV spectroscopy, a recalibration factor for the SXR emissivity is calculated making the method robust against the decrease in the sensitivity of the SXR diodes which has been observed across multiple campaigns. The final 2D W density map is checked for consistency versus the time-evolution of the W concentration measurement from VUV spectroscopy, toroidal rotation measurements from charge exchange recombination spectroscopy, and tomographic reconstructions of bolometry data. The method has been found to be robust for W concentrations above a few 10 -5 and in cases where the contributions from other medium-Z impurities such as Ni are negligible.

47 OTHER INSTRUMENTATION↗