Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Automated Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Effects of Granular Control on Customers’ Perspective and Behavior with Automated Demand Response Systems

Automated demand response (Auto-DR) is expected to close the loop between buildings and the grid by providing machine-to-machine communications to curtail loads without the need for human intervention. Hence, it can offer more reliable and repeatable demand response results to the grid than the manual approach and make demand response participation a hassle-free experience for customers. However, many building operators misunderstand Auto-DR and are afraid of losing control over their building operation. To ease the transition from manual to Auto-DR, we designed and implemented granular control of Auto-DR systems so that building operators could modify or opt out of individual load-shed strategies whenever they wanted. This paper reports the research findings from this effort demonstrated through a field study in large commercial buildings located in New York City. We focused on (1) understanding how providing granular control affects building operators’ perspective on Auto-DR, and (2) evaluating the usefulness of granular control by examining their interaction with the Auto-DR user interface during test events. Through trend log analysis, interviews, and surveys, we found that: (1) the opt-out capability during Auto-DR events can remove the feeling of being forced into load curtailments and increase their willingness to adopt Auto-DR; (2) being able to modify individual load-shed strategies allows flexible Auto-DR participation that meets the building’s changing operational requirements; (3) a clear display of automation strategies helps building operators easily identify how Auto-DR is functioning and can build trust in Auto-DR systems.

Schetrit, Oren↗

Ultrasound Characterization of Plastic Bonded Explosives With Varied Binder Content and Density

Advanced explosive formulations and methods of production require rapid characterization for both processes and materials. Here, we present results for ultrasound characterization of a plastic bonded explosive (PBX) formulation as a function of binder weight percent and pressing density using through-transmission sound speed measurements. The explosive in this study was composed of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) combined with the fluoropolymer binder Kynar Ultraflex B. Binder content ranged from 2.6 wt.% to 11.5 wt.% with associated explosive formulation densities from 1.69 g/cc to 1.89 g/cc. We find linear and nonlinear changes in longitudinal and shear sound speeds, peak frequencies, and measured elastic properties for the different PBX formulations. These measured changes can differentiate the tested formulations, highlighting the potential for ultrasound as a nondestructive characterization method for newly-formulated PBXs. We also demonstrate through-transmission measurements using different coupling media and present results from an ultrasound technique called resonant ultrasound spectroscopy (RUS). Both transmission and RUS approaches may allow for rapid and even automated characterization of PBX components suitable for high-throughput manufacturing operations.

Engineering↗

Parallel Radioisotope Collection and Analysis in Response to the Fukushima Release

Two independent air samplers were operated at Pacific Northwest National Laboratory in parallel during the collection of samples from the Fukushima reactor releases. One system is an automated aerosol collection and analysis unit, while the other was a manual sampler of higher daily air volume. The samples collected each day showed excellent correlation in radionuclide activity, although some variations were seen. These variations illustrate the reproducibility of the air sample radionuclide measurements made by the Comprehensive Nuclear-Test-Ban Treaty International Monitoring System (IMS) and show a simple way to acquire useful parallel samples for scientific purposes. In particular, a party wishing to have a “copy” of a sample acquired by the verification regime of the treaty could employ this method and have results similar to the IMS station at low cost and even higher sensitivity.

Atmospheric Aerosol Sampling↗

Autonomous online optimization of a closed-circuit reverse osmosis system

As freshwater becomes increasingly scarce, many industrial and municipal water utilities look at premise-scale water treatment and reuse to meet water demand. Closed-circuit reverse osmosis (CCRO) has been proposed as a promising process design to do so. This sequencing batch process enables operation at higher brine salinity levels by means of a recycle flow. Optimal operation requires that the maximum salinity level at the membrane surface represents an optimal trade-off between brine disposal costs and energy efficiency. This maximum salinity level may change over time as the feed water composition changes and electricity markets fluctuate. In this article, we present the results of the experimental evaluation of an automatic technique for continuous online optimization, known as extremum seeking control. This technique has a long history in the process control community but has received little traction so far in the water industry. We modify this technique to enable its use for online optimization of CCRO, specifically to account for its sequential batch operation. We challenge the optimization schemes through several experimental tests and illustrate the advantages and drawbacks of extremum-seeking control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic Inc., Barco Corp Consultant Agreement, Fujifilm Medical Systems.

60 APPLIED LIFE SCIENCES↗

OpenMC

OpenMC is an open source, community-developed framework for performing Monte Carlo particle transport calculations.It is capable of simulating neutron and photon transport below ~50 MeV and also includes a model for bremsstrahlung production of photons by electrons/positrons. Fixed source, k-eigenvalue, and subcritical multiplication problems can be solved. Problem geometries can be modeled either using constructive solid geometry or a CAD representation. A flexible and efficient tally system enables a wide variety of physical quantities to be tallied and analyzed. OpenMC can run in parallel using a hybrid MPI and OpenMP programming model and has been extensively tested on leadership class supercomputers. A built-in Bateman equation solver enables the modeling of material composition changes due to irradiation. One of the unique features of OpenMC is its rich, extensible Python and C/C++ programming interfaces that enable programming pre- and post-processing, multigroup cross section generation, workflow automation, multiphysics coupling, and the visualization of geometry and tally results. In addition to the core Monte Carlo transport solver and associated APIs, OpenMC includes a Python-based nuclear data interface that enables power users to inspect, modify,and perform various types of nuclear data processing on ENDF, ACE, and OpenMC¿s native HDF5 files

ROMANO, PaulK.↗

Smart align -- A new tool for robust non-rigid registration of scanning microscope data

Many microscopic investigations of materials may benefit from the recording of multiple successive images. This can include techniques common to several types of microscopy such as frame averaging to improve signal-to-noise ratios (SNR) or time series to study dynamic processes or more specific applications. In the scanning transmission electron microscope, this might include focal series for optical sectioning or aberration measurement, beam damage studies or camera-length series to study the effects of strain; whilst in the scanning tunnelling microscope, this might include bias voltage series to probe local electronic structure. Whatever the application, such investigations must begin with the careful alignment of these data stacks, an operation that is not always trivial. In addition, the presence of low-frequency scanning distortions can introduce intra-image shifts to the data. Here, we describe an improved automated method of performing non-rigid registration customised for the challenges unique to scanned microscope data specifically addressing the issues of low-SNR data, images containing a large proportion of crystalline material and/or local features of interest such as dislocations or edges. Careful attention has been paid to artefact testing of the non-rigid registration method used, and the importance of this registration for the quantitative interpretation of feature intensities and positions is evaluated.

36 MATERIALS SCIENCE↗

Search for Infrasound Signals in InSight Data Using Coupled Pressure/Ground Deformation Methods

The unprecedented quality and sampling rate of seismometer and pressure sensors of the InSight Mars mission allow us to investigate infrasound through its pressure and ground deformation signals. This study focuses on compliance effects induced by acoustic waves propagating almost horizontally close to the surface. The compliance of acoustic waves is first estimated using the compliance estimates from pressure perturbations moving at wind speed. Then, a marker of compliance events is used to detect events of ground deformation induced by pressure variations, in three frequency bands from 0.4 to 3.2 Hz, from InSight sol 180 to 690. Additional selection criteria are imposed on the detected events to focus on acoustic waves and to remove various noise sources (e.g., wind effects or seismometer artifacts). After an automated selection, the visual inspection of the records allows us to validate two infrasound candidates that cannot be related to pressure perturbations moving at wind speed nor to known noise sources. For our highest quality infrasound candidate, the relation between this event and a convective vortex occuring 10 s later is tested. The azimuth of the vortex position at the time of infrasound detection is not consistent with the arrival azimuth of the suspected infrasound inferred from the polarization of seismometer records, thus the link between these two phenomena cannot be demonstrated. Further investigations would require a better understanding of wind-related noise impacting InSight sensors and of the effects of lateral variations of subsurface mechanical properties on the ground deformations induced by atmospheric pressure variations.

58 GEOSCIENCES↗

Improving and Assessing Planet Sensitivity of the GPI Exoplanet Survey with a Forward Model Matched Filter

We present a new matched-filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar point-spread function (PSF) is first subtracted using a Karhunen-Loéve image processing (KLIP) algorithm with angular and spectral differential imaging (ADI and SDI). The KLIP-induced distortion of the astrophysical signal is included in the matched-filter template by computing a forward model of the PSF at every position in the image. To optimize the performance of the algorithm, we conduct extensive planet injection and recovery tests and tune the exoplanet spectra template and KLIP reduction aggressiveness to maximize the signal-to-noise ratio (S/N) of the recovered planets. We show that only two spectral templates are necessary to recover any young Jovian exoplanets with minimal S/N loss. We also developed a complete pipeline for the automated detection of point-source candidates, the calculation of receiver operating characteristics (ROC), contrast curves based on false positives, and completeness contours. We process in a uniform manner more than 330 data sets from the Gemini Planet Imager Exoplanet Survey and assess GPI typical sensitivity as a function of the star and the hypothetical companion spectral type. This work allows for the first time a comparison of different detection algorithms at a survey scale accounting for both planet completeness and false-positive rate. We show that the new forward model matched filter allows the detection of 50% fainter objects than a conventional cross-correlation technique with a Gaussian PSF template for the same false-positive rate.

79 ASTRONOMY AND ASTROPHYSICS↗

Vertically Resolved Retrievals of Aerosol Concentrations and Effective Radii from the DOE Combined HSRL and Raman lidar Measurement Study (CHARMS) Merged High-Spectral-Resolution Lidar-Raman Lidar Data Set

The Department of Energy’s (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility is a key component of DOE’s research strategy to address global climate change. The objective of the ARM Facility is to provide an experimental testbed for studying important atmospheric effects, particularly cloud and aerosol processes, and testing parameterizations of these processes for use in climate change models. ARM observational sites include a broad array of instruments to characterize cloud and aerosol properties, atmospheric state variables, and incoming and outgoing radiation. Advanced lidar systems provide valuable and unique information about the atmospheric column. We examine the potential for providing vertically resolved information about aerosol size and concentration with a combination of two such lidar systems, the Raman lidar and the High-Spectral-Resolution Lidar (HSRL). Currently ARM has a limited ability to remotely measure profiles of aerosol optical and microphysical properties on an operational basis. Although the Southern Great Plains (SGP), Eastern North Atlantic (ENA), and North Slope of Alaska (NSA, Oliktok Point location only) Raman lidars provide profiles of aerosol backscatter and extinction at 355 nm, additional information is required to better characterize the impacts of aerosols on radiation and clouds. Recent advances in lidar retrieval theory and algorithm development (Müller et al. 1999, 2014; Chemyakin et al. 2014) demonstrate that multi-wavelength lidar retrieval algorithms that use measurements of aerosol extinction at both 355 and 532 nm and backscatter at 355, 532, and 1064 nm have the potential to constrain both the aerosol optical (e.g., complex index of refraction, scattering, etc.) and microphysical properties (e.g., effective radius, concentration). This advancement greatly increases the utility of the remote-sensed aerosol observations. Based on this work, the HSRL group at the National Aeronautics and Space Administration (NASA)’s Langley Research Center (LaRC) developed automated algorithms for retrieving aerosol optical and microphysical properties, demonstrated these retrievals using data from the unique NASA/LaRC airborne multi-wavelength HSRL-2 system, and validated these retrievals using coincident airborne in situ data (Müller et al. 2014; Sawamura et al. 2017). We report here on the use of ARM instrumentation to gather a multi-wavelength ground-based lidar data set to test such retrievals. Continuous (24/7) operation of the co-located SGP Raman lidar and University of Wisconsin (UW) HSRL during the 10-week Combined HSRL and Raman lidar Measurement Study (CHARMS) (mid-July through September 2015) allowed the acquisition of a unique, multi-wavelength ground-based lidar data set. The ARM SGP Raman lidar (RLID) measured profiles of aerosol backscatter, extinction, and depolarization at 355 nm and profiles of water vapor mixing ratio and temperature. The UW HSRL simultaneously measured profiles of aerosol backscatter, extinction and depolarization at 532 nm and aerosol backscatter at 1064 nm. This RLID+HSRL combination provided a test data set to investigate these more advanced aerosol retrieval techniques with the potential to greatly improve aerosol characterization in the lower atmosphere.

54 ENVIRONMENTAL SCIENCES↗

Robot-Powered Reliability Testing at NREL's ESIF

With auto manufacturers expected to roll out fuel cell electric vehicles in the 2015 to 2017 timeframe, the need for a reliable hydrogen fueling infrastructure is greater than ever. That's why the National Renewable Energy Laboratory (NREL) is using a robot in its Energy Systems Integration Facility (ESIF) to assess the durability of hydrogen fueling hoses, a largely untested—and currently costly—component of hydrogen fueling stations. The automated machine mimics the repetitive stress of a human bending and twisting the hose to refuel a vehicle—all under the high pressure and low temperature required to deliver hydrogen to a fuel cell vehicle's onboard storage tank.

42 ENGINEERING↗

Design and testing of ultrasound probe adapters for a robotic imaging platform

Medical imaging-based triage is a critical tool for emergency medicine in both civilian and military settings. Ultrasound imaging can be used to rapidly identify free fluid in abdominal and thoracic cavities which could necessitate immediate surgical intervention. However, proper ultrasound image capture requires a skilled ultrasonography technician who is likely unavailable at the point of injury where resources are limited. Instead, robotics and computer vision technology can simplify image acquisition. As a first step towards this larger goal, here, we focus on the development of prototypes for ultrasound probe securement using a robotics platform. The ability of four probe adapter technologies to precisely capture images at anatomical locations, repeatedly, and with different ultrasound transducer types were evaluated across more than five scoring criteria. Testing demonstrated two of the adapters outperformed the traditional robot gripper and manual image capture, with a compact, rotating design compatible with wireless imaging technology being most suitable for use at the point of injury. Next steps will integrate the robotic platform with computer vision and deep learning image interpretation models to automate image capture and diagnosis. This will lower the skill threshold needed for medical imaging-based triage, enabling this procedure to be available at or near the point of injury.

47 OTHER INSTRUMENTATION↗

BRIGHTEST X-RAY CLUSTERS OF GALAXIES IN THE CFHTLS WIDE FIELDS: CATALOG AND OPTICAL MASS ESTIMATOR

The Canada-France-Hawaii Telescope Legacy Survey (CFHTLS) presents a unique data set for weak-lensing studies, having high-quality imaging and deep multiband photometry. We have initiated an XMM-CFHTLS project to provide X-ray observations of the brightest X-ray-selected clusters within the wide CFHTLS area. Performance of these observations and the high quality of CFHTLS data allow us to revisit the identification of X-ray sources, introducing automated reproducible algorithms, based on the multicolor red sequence finder. We have also introduced a new optical mass proxy. We provide the calibration of the red sequence observed in the Canada-France-Hawaii filters and compare the results with the traditional single-color red sequence and photo-z. We test the identification algorithm on the subset of highly significant XMM clusters and identify 100% of the sample. We find that the integrated z-band luminosity of the red sequence galaxies correlates well with the X-ray luminosity, with a surprisingly small scatter of 0.20 dex. We further use the multicolor red sequence to reduce spurious detections in the full XMM and ROSAT All-Sky Survey (RASS) data sets, resulting in catalogs of 196 and 32 clusters, respectively. We made spectroscopic follow-up observations of some of these systems with HECTOSPEC and in combination with BOSS DR9 data. We also describe the modifications needed to the source detection algorithm in order to maintain high purity of extended sources in the shallow X-ray data. We also present the scaling relation between X-ray luminosity and velocity dispersion.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Smart Grid Technologies Employed for System Reliability Improvement: Pacific Northwest Smart Grid Demonstration Experience

The Pacific Northwest Smart Grid Demonstration (PNWSGD) was a smart grid technology performance evaluation project that included multiple U.S. states and cooperation from multiple electric utilities in the northwest region. One of the local objectives for the project was to achieve improved distribution system reliability. Toward this end, some PNWSGD utilities automated their distribution systems, including the application of fault detection, isolation, and restoration and advanced metering infrastructure. In light of this investment, a major challenge was to establish a correlation between implementation of these smart grid technologies and actual improvements of distribution system reliability. This paper proposes using Welch’s t-test to objectively determine and quantify whether distribution system reliability is improving over time. The proposed methodology is generic, and it can be implemented by any utility after calculation of the standard reliability indices. The effectiveness of the proposed hypothesis testing approach is demonstrated through comprehensive practical results. It is believed that wider adoption of the proposed approach can help utilities to evaluate a realistic long-term performance of smart grid technologies.

Agalgaonkar, Yashodhan P. (ORCID:0000000290061848)↗

Deep Learning for Automated Detection and Identification of Migrating American Eel Anguilla rostrata from Imaging Sonar Data

Adult American eels (Anguilla rostrata) are vulnerable to hydropower turbine mortality during outmigration from growth habitat in inland waters to the ocean where they spawn. Imaging sonar is a reliable and proven technology for monitoring of fish passage and migration; however, there is no efficient automated method for eel detection. We designed a deep learning model for automated detection of adult American eels from sonar data. The method employs convolution neural network (CNN) to distinguish between 14 images of eels and non-eel objects. Prior to image classification with CNN, background subtraction and wavelet denoising were applied to enhance sonar images. The CNN model was first trained and tested on data obtained from a laboratory experiment, which yielded overall accuracies of >98% for image-based classification. Then, the model was trained and tested on field data that were obtained near the Iroquois Dam located on the St. Lawrence River; the accuracy achieved was commensurate with that of human experts.

13 HYDRO ENERGY↗

Technology Solutions Case Study: Apartment Compartmentalization with an Aerosol-Based Sealing Process

Air sealing of building enclosures is a difficult and time-consuming process. Current methods in new construction require laborers to physically locate small and sometimes large holes in multiple assemblies and then manually seal each of them. This research study by Building America team Consortium for Advanced Residential Buildings demonstrated the automated air sealing and compartmentalization of buildings through the use of an aerosolized sealant developed by the Western Cooling Efficiency Center at University of California Davis. CARB demonstrated this new technology application in a multifamily building in Queens, NY. The effectiveness of the sealing process was evaluated by three methods: air leakage testing of overall apartment before and after sealing, point-source testing of individual leaks, and pressure measurements in the walls of the target apartment during sealing. Aerosolized sealing was successful by several measures in this study. Many individual leaks that are labor-intensive to address separately were well sealed by the aerosol particles. In addition, many diffuse leaks that are difficult to identify and treat were also sealed. The aerosol-based sealing process resulted in an average reduction of 71% in air leakage across three apartments and an average apartment airtightness of 0.08 CFM50/SF of enclosure area.

Aerosol sealant↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Beyond DERMS: Demonstration of Automated Grid Services, Mode Transition, and Resilience

This report describes the results of more advanced use cases including Ancillary Services, Black-sky-day operation, and Mode Switching from Phase 3 of the “Beyond DERMS” project aiming to build, deploy, and demonstrate a holistic platform that supports the integrated operation and planning of future power distribution networks with bi-directional power flows, many diverse distributed energy resources (DERs), and inverter-based resources. These test results demonstrated how a Beyond DERMS platform can fuse together AMI, SCADA, and DER data to provide a utility with deep insights into distribution network operations and planning, extending the value of DERMS and BTM DER resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗