Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A time-resolved spectroscopic diagnostic based on fast scintillator and optical fiber array for z-pinch plasmas

We report a specially designed type of temporal resolved x-ray spectroscopic diagnostic using a spherically bent quartz crystal for z-pinch plasmas. Registration of time-resolved spectra was accomplished by coupling fast plastic scintillator, an optical fiber array, an optical streak camera, and a charge coupled device as the recording medium of this diagnostic. The diagnostic has been tested in imploding wire array experiments on S-300 pulsed power facility. Time-resolved K-shell lines were successfully obtained for aluminum wire array implosion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new soft x-ray pulse height analysis array in the HL-2A tokamak

A new soft x-ray pulse height analysis (PHA) array including nine independent subsystems, on basis of a nonconventional software multichannel analysis system and a silicon drift detector (SDD) linear array consisting of nine high performance SDD detectors, has been developed in the HL-2A tokamak. The use of SDD has greatly improved the measurement accuracy and the spatiotemporal resolutions of the soft x-ray PHA system. Since the ratio of peak to background counts obtained from the SDD PHA system is very high, p/b{>=}3000, the soft x-ray spectra measured by the SDD PHA system can approximatively be regarded as electron velocity distribution. The electron velocity distribution can be well derived in the pure ohmic and auxiliary heating discharges. The performance of the new soft x-ray PHA array and the first experimental results with some discussions are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axial x-ray backlighting of wire-array Z-pinches using X pinches

For the first time, a geometry has been developed to allow for an axial imaging system for wire-array Z-pinch experiments that produce high-resolution x-ray images. The new geometry required a significant redesign of the electrode hardware. Calibrated areal density measurements of the Z-pinch plasma including wire cores, coronal plasma, streaming plasma, and the precursor were obtained. The system used eight-wire molybdenum (Mo) X pinches in series with and directly below the Z-pinch axis to provide micron-scale x-rays sources for point-projection radiography. The images formed on the x-ray sensitive film had a 15 mm diameter field of view at the center height of the array and a magnification of about 7.5:1. Titanium (Ti) filters in front of the film transmitted radiation in the spectral range of 3-5 keV. For calibration, a separate film with the same thickness Ti filter was placed the same distance from the X pinch. This film had an unobstructed path that bypasses the Z-pinch but included step wedges for calibration of the Z-pinch plasma. The step wedges had thicknesses of tungsten (W) ranging from 0.015 to 1.1 {mu}m to obtain areal density measurements of the W plasma from the wire-array. Images had subnanosecond temporal resolution and about 10 {mu}m spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tests of a C{sub 6}D{sub 6} Deuterated Scintillator Array and Measurements of (d, n) Cross Sections

A deuterated liquid-scintillator neutron detector array (C{sub 6}D{sub 6}) has been developed and tested in-beam, which permits useable neutron energy measurements without need of time-of-flight (ToF), while still providing excellent n/gamma and muon discrimination. A similar detector of the same size based on (C{sub 6}H{sub 6}) also was tested for comparison purposes. The exothermic reactions {sup 3}H(d,n){sup 4}He and {sup 2}H(d,n){sup 3}He were used to deduce neutron spectra from the specially designed C{sub 6}D{sub 6} liquid scintillators. Major features of the detector and its response to high-energy neutrons and gammas from a {sup 13}C(d,n){sup 14}N experiment are presented. Preliminary cross sections for the ground and excited states of {sup 14}N have been measured using the detector array. The array should be well-suited for study of many reactions involving neutrons, including exothermic (d, n) reactions with radioactive ion beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medipix3 array high performance read-out board for synchrotron research

The Medipix3 ASIC is one of the most advanced chip that is presently available to build photon counting area detectors. The capabilities of the chip include adjacent pixels charge summing circuitry to sort out the distortion due to charge sharing, simultaneous counting and read-out that enables frames to be acquired without dead time, the colour mode of operation that enables up to eight energy bands to be acquired. In order to fully exploit the capabilities of the Medipix3 chip in synchrotron research, a high performance electronic board capable of driving large arrays of chips is necessary. We propose a parallel read-out board of Medipix3 chip arrays with a scalable architecture that allows driving the Medipix3 chip in all of its modes of operation. The board functions include the control of the chip arrays, data formatting and data compression, the management of the communications with the data storage devices, and operation in various trigger modes. In addition to this the board will have some 'intelligence' embedded. This will add some very important features to the final detector such as pattern recognition, capability of variable frame duration as a function of the photon flux, feedback to other equipment and real time calculations of data relevant to experiments such as the autocorrelation function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dot arrays of L1{sub 0}-type FePt ordered alloy perpendicular films fabricated using low-temperature sputter film deposition

Using ultrahigh vacuum sputter film deposition, we fabricated L1{sub 0}-type Fe{sub 50}Pt{sub 50} ordered alloy perpendicular films on MgO(001) single-crystal substrates and 2.5 in. glass disks at low substrate temperatures of 200-350 deg. C. Then we examined the magnetic properties of the dot arrays made from these films. The uniaxial magnetic anisotropy K{sub u} for L1{sub 0}-type FePt films (10 nm in thickness) deposited with a Pd underlayer on MgO(001) substrates reached about 2 x 10{sup 7} erg/cm{sup 3} at the substrate temperature T{sub s} of 200 deg. C, and 3 x 10{sup 7} erg/cm{sup 3} at T{sub s} = 250 deg. C. The order parameter S was about 0.46 at T{sub s} = 300 deg. C. Moreover, K{sub u} for L1{sub 0}-FePt films fabricated on glass disks using MgO/Cr underlayers shows 3.4 x 10{sup 7} erg/cm{sup 3} at T{sub s} = 300 deg. C, which was almost equal to that for FePt single-crystal films deposited on Pd/MgO(001). The switching field distribution {sigma}/H{sub c} for dot arrays made from L1{sub 0}-FePt film [5 nm in thickness, on Pd/MgO(001) at T{sub s} = 250 deg. C] was small; {sigma}/H{sub c}= 0.11 for a dot diameter of 15 nm. This value was smaller than that of hcp-Co{sub 75}Pt{sub 25} dot arrays ({sigma}/H{sub c} = 0.18). The difference was mainly attributable to the degree of the easy axis distribution. This result demonstrates the homogeneous formation of a L1{sub 0}-type ordered structure in the FePt layers.

36 MATERIALS SCIENCE↗

Influence of the adatom diffusion on selective growth of GaN nanowire regular arrays

Molecular beam epitaxy (MBE) on patterned Si/AlN/Si(111) substrates was used to obtain regular arrays of uniform-size GaN nanowires (NWs). The silicon top layer has been patterned with e-beam lithography, resulting in uniform arrays of holes with different diameters (d{sub h}) and periods (P). While the NW length is almost insensitive to the array parameters, the diameter increases significantly with d{sub h} and P till it saturates at P values higher than 800 nm. A diffusion induced model was used to explain the experimental results with an effective diffusion length of the adatoms on the Si, estimated to be about 400 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structure and magnetic properties of three-dimensional (La,Sr)MnO{sub 3} nanofilms on ZnO nanorod arrays

Three-dimensional (3D) cubic perovskite (La,Sr)MnO{sub 3} (LSMO) nanofilms have been deposited on ZnO nanorod arrays with controlled dimensionality and crystallinity by radio frequency (rf) magnetron sputtering and post thermal annealing. Compared to the two-dimensional (2D) LSMO nanofilm on flat Si, the structure and magnetic properties of 3D LSMO nanofilms on ZnO nanorod arrays have a strong anisotropic morphology and thickness dependence. Ferromagnetic property has been observed in both 2D and 3D LSMO nanofilms while a ferromagnetic-superparamagnetic transition was revaled in 3D LSMO nanofilms on ZnO nanorod array with decreasing nanofilm thickness, due to a large surface dispersion effect. The LSMO/ZnO nanofilm/nanorod structures could open up new avenues for intriguing magnetic properties studies and applications of nanoscale perovskites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Investigation Of Exotic Shapes, Correlations And Isomers In Nuclei With Large Compton Suppressed Clover Array

An array is designed for 24 Compton suppressed clover detectors. Recent results from the array will be presented which highlights the structure of nuclei in A {approx} 110 and 130 region and investigation of different reactions dynamics. The perspectives offered by the forthcoming operation of the clover array coupled to a new digital data acquisition system are also discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Injection-locking Oscillator Array for RF Spectrum Analysis

A highly parallel radio frequency receiver using an array of injection-locking oscillators for on-chip, rapid estimation of signal amplitudes and frequencies is considered. The oscillators are tuned to different natural frequencies, and variable gain amplifiers are used to provide negative feedback to adapt the locking band-width with the input signal to yield a combined measure of input signal amplitude and frequency detuning. To further this effort, an array of 16 two-stage differential ring oscillators and 16 Gilbert-cell mixers is designed for 40-400 MHz operation. The injection-locking oscillator array is assembled on a custom printed-circuit board. Control and calibration is achieved by on-board microcontroller.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous complete opaqueness in a sparse array of gold nanoparticle chains

We report on an anomalous polarization-switching extinction effect in a sparse array of gold nanoparticle chains: under normal incidence of light, the array is almost transparent for one polarization; whereas it is fully opaque (with nearly zero transmittance) for the orthogonal polarization within a narrow band, even though the nanoparticles cover only a tiny fraction (say, 3.5%) of the transparent substrate surface. We reveal that the strong polarization-dependent short-range dipolar coupling and long-range radiative coupling of gold nanoparticles in this highly asymmetric array is responsible for this extraordinary effect.

36 MATERIALS SCIENCE↗

Observation of plasma array dynamics in 110 GHz millimeter-wave air breakdown

We present dynamical measurements of self-organizing arrays of plasma structures in air induced by a 110 GHz millimeter-wave beam with linear or circular polarization. The formation of the individual plasmas and the growth of the array pattern are studied using a fast-gated (5-10 ns) intensified camera. We measure the time-dependent speed at which the array pattern propagates in discrete steps toward the millimeter-wave source, observing a peak speed greater than 100 km/s. We observe the expansion of an initially spherical plasma into a disk or an elongated filament, depending on the polarization of the incident beam. The results show good agreement with one-dimensional ionization-diffusion theory and two-dimensional simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Deposition of Microcolumnar Scintillator on CMOS SSPM Array: Toward a Photon Counting Detector for X-Ray/Gamma Ray Imaging

We are developing a modular, low-cost, photon-counting detector based on a scintillator coupled to a solid-state photodetector. A working prototype was successfully developed by depositing CsI:Tl directly onto a CMOS SSPM array designed by RMD and custom-fabricated by a commercial foundry. The device comprised a 6x6 array of 1.5x1.5 mm{sup 2} macro-pixels, each containing a 36x36 array of resistively coupled micro-pixels, that was subjected to vapor deposition of columnar CsI:Tl. Direct deposition eliminates the gap between the scintillator and SSPM and creates a better optical bond than does index-matching grease. This paper compares the performance of SSPMs with directly deposited CsI:Tl, in terms of signal-to-noise ratio and light spread, against devices using monolithic single crystals or pixelated single crystals coupled to the SSPM. Due to the reduction in light scattering and optical losses in the interface, the directly deposited CsI:Tl demonstrated significantly better position sensitivity, with at least a factor of 2 increase in SNR compared to a single crystal. These data indicate that a photodetector with substantially smaller macro-pixel dimensions than used here could be used to implement a low-energy X-ray/gamma-ray imaging and spectroscopy detector, particularly for applications where high resolution is of prime importance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical Thomson scattering measurements of cylindrical wire array parameters

A Thomson scattering diagnostic has been used to measure the parameters of cylindrical wire array Z pinch plasmas. The scattering operates in the collective regime ({alpha}>1) allowing spatially localised measurements of the ion or electron plasma temperatures and of the plasma bulk velocity. The ablation flow is found to accelerate towards the axis reaching peak velocities of 1.2-1.3 Multiplication-Sign 10{sup 7} cm/s in aluminium and {approx}1 Multiplication-Sign 10{sup 7} cm/s in tungsten arrays. Measurements of the precursor ion temperature shortly after formation are found to correspond to the kinetic energy of the converging ablation flow. Measurements during the implosion phase of tungsten arrays show the main imploding mass reaches velocities of {approx}1.4-1.7 Multiplication-Sign 10{sup 7} cm/s and is non-zero even at large radii close to the start of the x-ray pulse indicating current flow in the trailing mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

Controlled growth and multi-photon luminescence of hexagonal arrays of Au nanoparticles on anodic aluminum oxide templates

Au nanoparticles were deposited onto anodic aluminum oxide (AAO) templates by using a rotating sputtering technique. Interestingly, hexagonal arrays of Au nanoparticles were obtained at an appropriate rotating rate and deposition time. Strong three-photon luminescence was observed from the hexagonally arrayed Au nanoparticles, which is attributed to the strong enhancements of local electromagnetic fields at both excitation and emission wavelengths. Our findings provide a new method to prepare Au nanoparticle arrays with large field enhancements and could have prospective applications in plasmonic nanodevices, such as surface-enhanced Raman scattering substrates, and biosensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High compositional homogeneity in In-rich InGaAs nanowire arrays on nanoimprinted SiO{sub 2}/Si (111)

We report improved homogeneity control of composition-tuned In{sub 1-x}Ga{sub x}As (x < 0.4) nanowire (NW) arrays grown by catalyst-free molecular beam epitaxy (MBE) on nanoimprinted SiO{sub 2}/Si (111) substrates. Using very high As/(Ga+In) ratios at growth temperatures of 550 Degree-Sign C enabled uniform incorporation of the respective group-III elements (In,Ga) over the investigated composition range, confirmed by high-resolution x-ray diffraction (HRXRD) and energy dispersive x-ray spectroscopy. Low-temperature (20 K) photoluminescence of these In-rich In{sub 1-x}Ga{sub x}As NW ensembles reveal state-of-the-art linewidths of {approx}29-33 meV. These are independent of Ga content, suggesting an overall low degree of phase separation. In contrast, self-assembled, non-periodic In{sub 1-x}Ga{sub x}As NW arrays show larger inhomogeneity with increased peakwidths in 2{theta}-{omega} HRXRD scans as well as broadened Raman modes. These results demonstrate the excellent potential of site-selective MBE growth of high-periodicity non-tapered In{sub 1-x}Ga{sub x}As NW arrays with low size and composition dispersion for optimized device integration on Si.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Generation of extreme state of water by spherical wire array underwater electrical explosion

The results of the first experiments on the underwater electrical explosion of a spherical wire array generating a converging strong shock wave are reported. Using a moderate pulse power generator with a stored energy of {<=}6 kJ and discharge current of {<=}500 kA with a rise-time of {approx}300 ns, explosions of Cu and Al wire arrays of different diameters and with a different number and diameter of wires were tested. Electrical, optical, and destruction diagnostics were used to determine the energy deposited into the array, the time-of-flight of the shock wave to the origin of the implosion, and the parameters of water at that location. The experimental and numerical simulation results indicate that the convergence of the shock wave leads to the formation of an extreme state of water in the vicinity of the implosion origin that is characterized by pressure, temperature, and compression factors of (2 {+-} 0.2) Multiplication-Sign 10{sup 12} Pa, 8 {+-} 0.5 eV, and 7 {+-} 0.5, respectively.

42 ENGINEERING↗