Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adaptive optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Switchable resolution in soft x-ray tomography of single cells

The diversity of living cells, in both size and internal complexity, calls for imaging methods with adaptable spatial resolution. Soft x-ray tomography (SXT) is a three-dimensional imaging technique ideally suited to visualizing and quantifying the internal organization of single cells of varying sizes in a near-native state. The achievable resolution of the soft x-ray microscope is largely determined by the objective lens, but switching between objectives is extremely time-consuming and typically undertaken only during microscope maintenance procedures. Since the resolution of the optic is inversely proportional to the depth of focus, an optic capable of imaging the thickest cells is routinely selected. This unnecessarily limits the achievable resolution in smaller cells and eliminates the ability to obtain high-resolution images of regions of interest in larger cells. Here, we describe developments to overcome this shortfall and allow selection of microscope optics best suited to the specimen characteristics and data requirements. We demonstrate that switchable objective capability advances the flexibility of SXT to enable imaging cells ranging in size from bacteria to yeast and mammalian cells without physically modifying the microscope, and we demonstrate the use of this technology to image the same specimen with both optics.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of Long Duration Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure syndrome (VIIP) is a newly described space flight-associated medical condition made up of a constellation of symptoms affecting at least 34% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures, and is thought to be related to elevated intracranial pressure secondary to space flightinduced cephalad fluid shifts. Loss of visual acuity could be a significant threat to crew health and performance and may be suggestive of other adaptations with implications for years post-flight. Our primary objective is to determine whether vascular compliance is altered by space flight and whether such adaptations are related to the incidence of VIIP. In particular, we will measure ocular parameters and vascular compliance in vessels of the head and neck in astronauts who have no space flight experience, in astronauts before, during, and after space flight, and in bed rest subjects with conditions similar to space flight. Additionally, we will analyze astronaut data from the Lifetime Surveillance of Astronaut Health (LSAH) archive to determine which factors might be predictive of the development of VIIP. The project will be conducted in four separate but related parts. To understand the baseline condition of astronauts without any prior space flight experience, we will study 10 astronauts who have never flown in space by performing a comprehensive evaluation of the vasculature of the head, neck and eyes. Hemodynamic data (stroke volume and blood pressure), ocular (tonometry and ocular ultrasound), venous and arterial parameters will be acquired across a range of tilt angles (20, 10, 0, -10, -20 degrees). Vessels to be studied include the temporal, jugular, and vertebral veins and the cerebral, carotid and vertebral arteries. Ophthalmic data from the annual physical will be obtained through data sharing. To examine the relation between vascular compliance in the head and neck and the development of VIIP after a long duration space flight, we will study 10 astronauts before, during, and after long-duration ISS missions. Pre- and post-flight testing will be identical to that described above. During flight, images of the same vessels of interest will be obtained for later analysis. Ophthalmic data including VIIP scores will be obtained through data sharing from medically-required tests. To investigate the effects of age and elevated sodium intake, two potential contributors to VIIP, we will study 24 men (in two age groups: 25-35 and 45-55) during a 14 day 6deg head-down bed rest, a well-accepted analog of space flight. Standard NASA bed rest conditions will be maintained except for dietary sodium. Sodium intake will be similar to that of ISS astronauts, which is higher than consumed in previous bed rest studies. Pre- and post-bed rest testing procedures will be identical to the testing protocol described above for astronauts. Ophthalmic testing (optical coherence tomography, fundoscopy, and tonometry) will be conducted on the same day that vascular compliance measures are obtained. To identify parameters that may relate to an increase in an astronaut's susceptibility to developing VIIP, we will use data mining techniques to evaluate astronaut data obtained from the LSAH. Medical history, family history, space flight history and its related exposures, and history of high performance jet aircraft exposure will be examined for their potential relationship to ocular data. We hypothesize that the cephalad fluid shift induced by space flight will result in structural and functional adaptations in head and neck vessels leading to decreased vascular compliance and related to the development of VIIP symptoms. Further, although VIIP has not been observed in previous bed rest studies, we hypothesize that an elevated sodium intake will increase the incidence of VIIP symptoms in this space flight analog. Finally, we hypothesize that data mining analyses will reveal relationships between health history, previous exposures (including space flight and high performance aircraft), and the development of VIIP in the astronaut population.

Ribeiro, L. C.↗

An Intelligent Adaptable Monitoring Package. Final Report

The “Intelligent Adaptable Monitoring Package” project was a four-year effort that demonstrated the feasibility of integrated sensing packages at tidal and wave energy sites. Such integration is generally required by the breadth of sensors required to understand environmental effects at marine energy sites and the operational difficulty of deploying, maintaining, and recovering such sensors. Over the course of the project, the Adaptable Monitoring Package (AMP) was deployed in multiple settings, each corresponding to a project budget period: - Budget Period 1: Demonstration of cabled deployment at Pacific Northwest National Laboratory’s Marine Science Laboratory. The deployment highlighted AMP hardware endurance over a 4-month deployment in a tidally-dominated environment and laid the groundwork for machine learning algorithms to detect and classify targets present in active sonar data. - Budget Period 2: Demonstration of an autonomous deployment at PacWave South off the coast of Newport, Oregon. The deployment highlighted the stability of AMP hardware and software, with the autonomous package collecting data on a duty cycle over a 1.5-month deployment. - Budget Period 3: Demonstration of an autonomous deployment powered by a wave energy converter at the U.S. Navy’s Wave Energy Test Site. The deployment highlighted the potential of wave energy to power ocean observatories and led to the development of machine learning algorithms to detect and classify targets in optical camera data. In aggregate, this project’s greatest success was demonstrating the AMP’s flexibility in a range of deployment scenarios. Each budget period represented a “first of a kind” demonstration of integrated instrumentation – cabled AMP, autonomous AMP, wave-energy powered AMP – and each deployment helped to identify and set goals for the next. Further, despite the exploratory nature of these deployments, each one achieved high system up-time and proved that flexible integration of multiple sensors in a single package represents a viable strategy for marine energy environmental monitoring. The key lessons learned from the project are: - Without continuous power, either from a shore cable or in situ source, many of the benefits of integration are lost (If continuous power is not available, the ability to detect rare events is lost, as is the ability to minimize the risk of behavioral changes through adaptive sensing. However, even on a duty cycle, there is still value in being able to acquire synchronous data from multiple sensors.); and - Observations from a moving platform present substantially greater data processing challenges than those from stationary platforms. Finally, these deployments also demonstrate an important truth: successful integration alone does not guarantee that relevant data are collected. To grow the knowledge base about environmental interactions with marine energy converters, integrated systems, like the AMP, need to include the right sensor mix and connect the data pipelines to effective processing algorithms. These deployments establish a strong foundation for future collaborations with the environmental research community: not only to understand the environmental effects of marine energy, but also to improve our general ability to study life in the sea.

16 TIDAL AND WAVE POWER↗

Spaceborne astronomy with electro-optical image sensors

The Space Telescope, planned for orbiting in the early 1980s, is described, with emphasis on its electro-optical image sensing capability. Relative advantages of image tubes and solid state arrays as image detectors are summarized; image tube technology is well characterized, but preference may be given to a more versatile tandem solid state array consisting of one module with high silicon response covering most of the spectrum, and a second intensified array with ultraviolet sensitivity and low noise readout. The classical 'photoelectron noise limit' calculation is reviewed, and a detailed calculation of sensitivity limits adaptable to analysis of image tube or solid state array detectors is also given. In particular, characteristics of a filter to optimize the signal to noise ratio is determined. Typical sensitivity calculations for an image tube detector show that with an exposure of one orbital night (approximately 2000 seconds), 10% photometry may be done to a low limit of visual magnitude.

Bradley, W. C.↗

Coherent communication link using diode-pumped lasers

Work toward developing a diffraction limited, single frequency, modulated transmitter suitable for coherent optical communication or direct detection communication is discussed. Diode pumped, monolithic Nd:YAG nonplanar ring oscillators were used as the carrier beam. An external modulation technique which can handle high optical powers, has moderate modulation voltage, and which can reach modulation rates of 1 GHz was invented. Semiconductor laser pumped solid-state lasers which have high output power (0.5 Watt) and which oscillate at a single frequency, in a diffraction limited beam, at the wavelength of 1.06 microns were built. A technique for phase modulating the laser output by 180 degrees with a 40-volt peak to peak driving voltage is demonstrated. This technique can be adapted for amplitude modulation of 100 percent with the same voltage. This technique makes use of a resonant bulk modulator, so it does not have the power handling limitations of guided wave modulators.

Kane, Thomas J.↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗

Southwest Water Resources: Monitoring Surface Water Extents of Remote Stock Ponds in the Southwestern United States Using Earth Observing Systems for Enhanced Water Resources Management

Due to increasingly frequent and severe drought conditions in the southwestern US, land managers and livestock producers need to monitor stock ponds with increasing regularity. The ability to assess stock pond water levels with Earth observing satellite systems would enhance monitoring efforts of partners at the US Forest Service, Arizona Department of Game and Fish, and the Diablo Trust. This study employed Landsat 8 Operational Land Imager (OLI), Sentinel-1 C-band Synthetic Aperture Radar (C-SAR), and Sentinel-2 Multispectral Instrument (MSI) to monitor surface water extent for hundreds of critical stock ponds in Arizona. Using methods adapted from previously developed image processing workflows, this project conducted a time-series analysis to capture seasonal and interannual variations in surface water area between 2013 to 2021. In addition, end users can monitor the surface water extent of stock ponds through the developed Google Earth Engine software tool called Surface Water Identification and Forecasting Tool (SWIFT). SWIFT incorporates the Automated Water Extraction Index, Modified Normalized Difference Water Index, and Tasseled Cap-Wetness Index for optical imagery and the incidence angle, VV and VH polarization bands for Sentinel-1 imagery to detect small water bodies in the study area with an overall accuracy range of 88-93%. These tools will empower our partners to monitor the extents of water in their stock ponds remotely, enabling them to develop data-informed and sustainable management solutions for decades to come.

Rainey Aberle↗

Label-free DNA biosensing by topological light confinement

Large-area and transparent all-dielectric metasurfaces sustaining photonic bound states in the continuum (BICs) provide a set of fundamental advantages for ultrasensitive biosensing. BICs bridge the gap of large effective mode volume with large experimental quality factor. Relying on the transduction mechanism of reactive sensing principle, herein, we first numerically study the potential of subwavelength confinement driven by topological decoupling from free space radiation for BIC-based biosensing. Then, we experimentally combine this capability with minimal and low-cost optical setup, applying the devised quasi-BIC resonator for PNA/DNA selective biosensing with real-time monitoring of the binding event. A sensitivity of 20 molecules per micron squared is achieved, i.e. ≃0.01 pg. Further enhancement can easily be envisaged, pointing out the possibility of single-molecule regime. This work aims at a precise and ultrasensitive approach for developing low-cost point-of-care tools suitable for routine disease prescreening analyses in laboratory, also adaptable to industrial production control.

59 BASIC BIOLOGICAL SCIENCES↗

Embracing Uncertainty and Perseverance. A Brief Perspective on Conducting On-Site NDT Research

Dr. Judi E. See, a Systems Analyst and Human Factors Engineer at Sandia National Laboratories, reflects on her experience conducting NDT research in a male-dominated environment. She emphasizes the importance of persistence, flexibility, and persuasive skills in overcoming challenges, ranging from gaining access to test sites and equipment to building trust with inspectors. She shares her personal experience of navigating professional situations where gender disparities were evident, highlighting the need for women to adapt and overcome obstacles in traditionally male-dominated settings. See's journey demonstrates that perseverance and ingenuity can lead to significant contributions, process improvements, and recognition in the NDT field.

42 ENGINEERING↗

Mars Spark Source Prototype

The Mars Spark Source Prototype (MSSP) hardware has been developed as part of a proof of concept system for the detection of trace metals such as lead, cadmium, and arsenic in Martian dusts and soils. A spark discharge produces plasma from a soil sample and detectors measure the optical emission from metals in the plasma that will allow their identification and quantification. Trace metal measurements are vital for the assessment of the potential toxicity of the Martian environment for human exploration. The current method of X-ray fluorescence can yield concentrations only of major species. Other instruments are incompatible with the volume, weight, and power constraints for a Mars mission. The instrument will be developed primarily for use in the Martian environment, but would be adaptable for terrestrial use in environmental monitoring. This paper describes the Mars Spark Source Prototype hardware, the results of the characterization tests, and future plans for hardware development.

Eichenberg, Dennis J.↗

CCD Camera Lens Interface for Real-Time Theodolite Alignment

Theodolites are a common instrument in the testing, alignment, and building of various systems ranging from a single optical component to an entire instrument. They provide a precise way to measure horizontal and vertical angles. They can be used to align multiple objects in a desired way at specific angles. They can also be used to reference a specific location or orientation of an object that has moved. Some systems may require a small margin of error in position of components. A theodolite can assist with accurately measuring and/or minimizing that error. The technology is an adapter for a CCD camera with lens to attach to a Leica Wild T3000 Theodolite eyepiece that enables viewing on a connected monitor, and thus can be utilized with multiple theodolites simultaneously. This technology removes a substantial part of human error by relying on the CCD camera and monitors. It also allows image recording of the alignment, and therefore provides a quantitative means to measure such error.

Wake, Shane↗

Near Earth Asteroid Scout Solar Sail Thrust and Torque Model

The Near Earth Asteroid (NEA) Scout is a solar sail mission whose objective is to scout at least one Near Earth Asteroid to help prepare for human missions to Near Earth Asteroids. NEA Scout will launch as a secondary payload on the first SLS-Orion mission. NEA Scout will perform a small trim maneuver shortly after deploy from the spent SLS upper stage using a cold gas propulsion system, but from that point on will depend entirely on the solar sail for thrust. As such, it is important to accurately characterize the thrust of the sail in order to achieve mission success. Additionally, the solar sail creates a relatively large solar disturbance torque that must be mitigated. For early mission design studies a flat plate model of the solar sail with a fixed center of pressure was adequate, but as mission concepts and the sail design matured, greater fidelity was required. Here we discuss the progress to a three-dimensional sail model that includes the effects of tension and thermal deformation that has been derived from a large structural Finite Element Model (FEM) developed by the Langley Research Center. We have found that the deformed sail membrane affects torque relatively much more than thrust; a flat plate model could potentially model thrust well enough to close mission design studies, but a three-dimensional solar sail is essential to control system design. The three-dimensional solar sail model revealed that thermal deformations of unshielded booms would create unacceptably large solar disturbance torques. The original large FEM model was used in control and mission simulations, but was resulted in simulations with prohibitive run times. This led us to adapt the Generalized Sail Model (GSM) of Rios-Reyes. A design reference sail model has been baselined for NEA Scout and has been used to design the mission and control system for the sailcraft. Additionally, since NEA Scout uses reaction wheels for attitude pointing and control, the solar torque model is essentially to successfully design the NEA Scout momentum management control system. We have also updated the estimate of diffusivity used for the aluminized sail material based on optical testing of wrinkled sail material. The model presented here represents the current state of the art of NASA's ability to model solar sail thrust and torque.

Heaton, Andy↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

ITER ECH Transmission Line System Design and Status

The electron cyclotron (EC) heating & current drive (H&CD) system on ITER provides plasma heating by generating, transmitting, and launching high-intensity, high-frequency (170 GHz) electromagnetic wave energy steerable across the plasma cross-section. The transmission line (TL) subsystem connects the Matching Optics Unit (MOU) on each of the 24 gyrotrons to the 32 feed points in the four upper launchers and the 24 feed points in the equatorial launcher. Each TL must be able to operate at up to 1.2 MW of input power for up to 1 hour pulse lengths. The TL system contains 50 mm water-cooled corrugated waveguide, 90o miter bends, 140o miter bends, polarizer miter bend pairs, switches, expansion units, pumpouts, DC breaks, MOU-TL adapters, Radio Frequency (RF) loads, and isolation shutter valves. A detailed finite element analysis has been used to verify the thermo-mechanical performance of each component. The microwave performance has been analyzed using a 2-D electromagnetic code combined with a Monte Carlo code. This approach allows the impact of manufacturing and installation tolerances to be assessed and optimized to provide a high probability of achieving the system performance requirements. Prototypes of the waveguide and TL components have been fabricated and tested at high-power. Production contracts are now being issued for fabrication and delivery of the waveguide and components to ITER.

Hanson, Gregory↗

Structured illumination with thermal imaging (SI-TI): A dynamically reconfigurable metrology for parallelized thermal transport characterization

The recent push for the “materials by design” paradigm requires synergistic integration of scalable computation, synthesis, and characterization. Among these, techniques for efficient measurement of thermal transport can be a bottleneck limiting the experimental database size, especially for diverse materials with a range of roughness, porosity, and anisotropy. Traditional contact thermal measurements have challenges with throughput and the lack of spatially resolvable property mapping, while non-contact pump-probe laser methods generally need mirror smooth sample surfaces and also require serial raster scanning to achieve property mapping. Here, we present structured illumination with thermal imaging (SI-TI), a new thermal characterization tool based on parallelized all-optical heating and thermometry. Experiments on representative dense and porous bulk materials as well as a 3D printed thermoelectric thick film (~50 μm) demonstrate that SI-TI (1) enables paralleled measurement of multiple regions and samples without raster scanning; (2) can dynamically adjust the heating pattern purely in software, to optimize the measurement sensitivity in different directions for anisotropic materials; and (3) can tolerate rough (~3 μm) and scratched sample surfaces. Here, this work highlights a new avenue in adaptivity and throughput for thermal characterization of diverse materials.

42 ENGINEERING↗

Execution of the Spitzer In-orbit Checkout and Science Verification Plan

The Spitzer Space Telescope is an 85-cm telescope with three cryogenically cooled instruments. Following launch, the observatory was initialized and commissioned for science operations during the in-orbit checkout (IOC) and science verification (SV) phases, carried out over a total of 98.3 days. The execution of the IOC/SV mission plan progressively established Spitzer capabilities taking into consideration thermal, cryogenic, optical, pointing, communications, and operational designs and constraints. The plan was carried out with high efficiency, making effective use of cryogen-limited flight time. One key component to the success of the plan was the pre-launch allocation of schedule reserve in the timeline of IOC/SV activities, and how it was used in flight both to cover activity redesign and growth due to continually improving spacecraft and instrument knowledge, and to recover from anomalies. This paper describes the adaptive system design and evolution, implementation, and lessons learned from IOC/SV operations. It is hoped that this information will provide guidance to future missions with similar engineering challenges

operations↗