Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

An OPO-Based Lidar System for Differential Absorption Measurements of Methane in the 3 micron region

A ground-based lidar system in the wavelength region of 1.45-4 microns for the remote measurement of methane is described. The laser transmitter consists of an injection-seeded Nd:YAG laser which pumps an OPO (optical parametric oscillator). The OPO output is tunable from 1.45-4 microns, with a bandwidth less than 500 MHz, and a pulse energy of 1 to 3 mJ at 3.29 microns. The receiver is cart-mounted and consists of a 14" telescope with 1.57 and 3.29 micron detector channels. A fast oscilloscope is used for data acquisition. The system performance will be tested through measurements of sources of atmospheric methane.

Lee, S. W.↗

Differential Absorption Lidar (DIAL) Measurements of Atmospheric Water Vapor Utilizing Robotic Aircraft

A new unpiloted air vehicle (UAV) based water vapor DIAL system will be described. This system is expected to offer lower operating costs, longer test duration and severe weather capabilities. A new high-efficiency, compact, light weight, diode-pumped, tunable Cr:LiSAF laser will be developed to meet the UAV payload weight and size limitations and its constraints in cooling capacity, physical size and payload. Similarly, a new receiver system using a single mirror telescope and an avalanche photo diode (APD) will be developed. Projected UAV parameters are expected to allow operation at altitudes up to 20 km, endurance of 24 hrs and speed of 400 km/hr. At these conditions measurements of water vapor at an uncertainty of 2-10% with a vertical resolution of 200 m and horizontal resolution of 10 km will be possible.

Hoang, Ngoc↗

Laboratory Studies of Chemical and Photochemical Processes Relevant to Stratospheric Ozone

This is the final report for this project. Its purpose is to reduce the uncertainty in rate coefficients for key gas-phase kinetic processes which impact our understanding of stratospheric ozone. The main emphasis of this work is on measuring the rate coefficients for the reactions of HO2 + O3, and HO2 + NO2 in the temperature range (200-240 K) relevant to the lower stratosphere. In order to accomplish this, a high pressure turbulent flow tube reactor was built and its flow characteristics were quantified. The instrument was coupled with tunable diode laser spectroscopy for HO2 detection. Room temperature measurements of the HO2 + NO2 rate coefficients over the pressure range of 50-300 torr agree well with previous measurements. Preliminary measurements of the HO2 + O, rate coefficients at 50 - 300 Torr over the temperature range of 208-294 K agree with the NASA evaluation from 294-225 K but deviate significantly (50 % higher) at approximately 210 K.

Villalta, P. W.↗

Diagnostics and Active Control of Aircraft Interior Noise

This project deals with developing advanced methods for investigating and controlling interior noise in aircraft. The work concentrates on developing and applying the techniques of Near Field Acoustic Holography (NAH) and Principal Component Analysis (PCA) to the aircraft interior noise dynamic problem. This involves investigating the current state of the art, developing new techniques and then applying them to the particular problem being studied. The knowledge gained under the first part of the project was then used to develop and apply new, advanced noise control techniques for reducing interior noise. A new fully active control approach based on the PCA was developed and implemented on a test cylinder. Finally an active-passive approach based on tunable vibration absorbers was to be developed and analytically applied to a range of test structures from simple plates to aircraft fuselages.

Fuller, C. R.↗

Line Narrowing Parameter Measurement by Modulation Spectroscopy

Accurate Characterization of Oxygen A-Band Line Parameters by Wavelength Modulation Spectroscopy with tunable diode lasers is an ongoing research at Old Dominion University, under sponsorship from NASA Langley research Center. The work proposed here will be undertaken under the guidance of Dr. William Chu and Dr. Lamont Poole of the Aerosol Research Branch at NASA Langley-Research Center in Hampton, Virginia. The research was started about two years ago and utilizes wavelength modulation absorption spectroscopy with higher harmonic detection, a technique that we developed at Old Dominion University, to obtain the absorption line characteristics of the Oxygen A-band rovibronic lines. Accurate characterization of this absorption band is needed for processing of data that will be obtained in experiments such as the NASA Stratospheric Aerosol and Gas Experiment III (SAGE III) as part of the US Mission to Planet Earth. The research work for Summer Fellowship undertook a measurement of the Dicke line-narrowing parameters of the Oxygen A-Band lines by using wavelength modulation spectroscopy. Our previous theoretical results had indicated that such a measurement could be done sensitively and in a convenient fashion by using this type of spectroscopy. In particular, theoretical results had indicated that the signal magnitude would depend on pressure in a manner that was very sensitive to the narrowing parameter. One of the major tasks undertaken during the summer of 1998 was to establish experimentally that these theoretical predictions were correct. This was done successfully and the results of the work are being prepared for publication. Experimental Results were obtained in which the magnitude of the signal was measured as a function of pressure, for various harmonic detection orders (N = 1, 2, 3, 4, 5). A comparison with theoretical results was made, and it was shown that the agreement between theory and experiment was very good. More importantly, however, it was shown that the measurement was yielded a very sensitive technique for obtaining the narrowing parameter that describes the deviation of Oxygen A-band lines from the Voigt profile. In particular, it was seen that the best fits were obtained consistently when the narrowing parameter value used was 0.022 1/cm, 1/Atm, Previous work, upon which the current work was based has resulted in several accurate measurements of properties of particular lines of the Oxygen A band. For example, this work has resulted in the measurement of the collision cross sections of several lines including the RQ(13,14) and the RR(15,15) lines. A major achievement of achievement of the work was also the demonstration that the technique we have developed can accurately probe the structure of the absorption lineshape function. In particular, the method we have developed is very well suited for experimentally probing the characteristics of lines in their wings. This work was accepted for publication in the Journal of Applied Physics, and is scheduled to appear in the December 15, 1998 issue.

Dharamsi, Amin N.↗

Advanced Exploration Technologies: Micro and Nano Technologies Enabling Space Missions in the 21st Century

Some of the many new and advanced exploration technologies which will enable space missions in the 21st century and specifically the Manned Mars Mission are explored in this presentation. Some of these are the system on a chip, the Computed-Tomography imaging Spectrometer, the digital camera on a chip, and other Micro Electro Mechanical Systems (MEMS) technology for space. Some of these MEMS are the silicon micromachined microgyroscope, a subliming solid micro-thruster, a micro-ion thruster, a silicon seismometer, a dewpoint microhygrometer, a micro laser doppler anemometer, and tunable diode laser (TDL) sensors. The advanced technology insertion is critical for NASA to decrease mass, volume, power and mission costs, and increase functionality, science potential and robustness.

Krabach, Timothy↗

KWIC: A Widefield Mid-Infrared Array Camera/Spectrometer for the KAO

The Kuiper Widefield Infrared Camera (KWIC) is an imaging spectrometer designed for use on the Kuiper Airborne Observator between 18 and 40 microns. The spectral resolution achieving devices are two fully tunable and scanning cryogenic Fabry-Perot interferometers that employ free standing metal mesh as the reflective surfaces. The detective device is a 128 x 128 pixel Si:Sb BIB array manufactured by Rockwell/Boeing for the SIRTF project. The plate scale for KWIC (one pixel subtends 2.73" x 2.73") was chosen so as to more than fully sample the KAO beam (approximately 9" at 31.5 microns), to enable effective image restoration techniques to be applied. Even so, KWIC has a rather large (5.8' x 5.8') field of view. KWIC has both high and low spectral resolution modes that are interchangeable in a few minutes time in flight on the KAO. The high resolution (R = lambda/(delta)lambda = 1000 to 6000) mode is suitable for detecting weak lines in the presence of strong continuum for Galactic sources, and for resolving broad extragalactic lines. The low resolution (R approximately 30 to 100) mode is suitable for imaging in the thermal dust continuum.

Stacey, Gordon J.↗

Mars Volatiles and Climate Surveyor (MVACS) Integrated Payload for the Mars Polar Lander Mission

The Mars Volatiles and Climate Surveyor (MVACS) integrated payload for the Mars Polar Lander will be launched in January 1999, with a scheduled landing on Mars' south-polar layered deposits in December 1999. Over the course of its 90-day nominal mission during the martian southern spring and summer seasons, it will make in situ measurements that will provide new insights into the behavior and distribution of martian volatiles, MVACS consists of four major instrument systems: a surface stereo imager (SSI), which will acquire multispectral stereo images of the surface and atmosphere; a 2-m robotic arm (RA), which will dig a O.5-m deep trench and acquire surface and subsurface samples that will be imaged by a focusable robotic arm camera (RAC), which will take close-up images of surface and subsurface samples at a spatial resolution of 21 micron; a meteorology package (MET), which will make the first measurements of surface pressure, temperature, and winds in Mars' southern hemisphere and employ a tunable diode laser (TDL) spectrometer to measure the water-vapor concentration and isotopic composition of CO2 in the martian atmosphere; and a thermal and evolved gas analyzer (TEGA), which will use differential scanning calorimetry and TDL-evolved gas analysis to determine the concentrations of ices, adsorbed volatiles, and volatile-bearing minerals in surface and subsurface soil samples. The unique in situ measurements made by MVACS at its high-latitude landing site will define a number of important aspects of the physical, isotopic, and chemical nature of the martian near-surface and subsurface environment that will be valuable in better understanding Mars meteorites and returned samples, as well as in the search for martian resources that could be utilized by humans.

Paige, D. A.↗

Study of the effects of MeV Ag, Cu, Au, and Sn implantation on the optical properties of LiNbO3

The authors present the results of characterization of linear absorption and nonlinear refractive index of Au, Ag, Cu and Sn ion implantation into LiNbO3. Ag was implanted at 1.5 MeV to fluences of 2 to 17 x 17(exp 16)/sq cm at room temperature. Au and Cu were implanted to fluences of 5 to 20 x 10(exp 16)/sq cm at an energy of 2.0 MeV. Sn was implanted to a fluence of 1.6 x 10(exp 17)/sq cm at 160 kV. Optical absorption spectrometry indicated an absorption peak for the Au implanted samples after heat treatment at 1,000 C at approx. 620 nm. The Ag implanted samples absorption peaks shifted from approx. 450 nm before heat treatment to 550 nm after 500 C for 1h. Heat treatment at 800 C returned the Ag implanted crystals to a clear state. Cu nanocluster absorption peaks disappears at 500 C. No Sn clusters were observed by optical absorption or XRD. The size of the Ag and Au clusters as a function of heat treatment were determined from the absorption peaks. The Ag clusters did not change appreciably in size with heat treatment. The Au clusters increased from 3 to 9 nm diameter upon heat treatment at 1000 C. TEM analysis performed on a Au implanted crystal indicated the formation of Au nanocrystals with facets normal to the c-axis. Measurements of the nonlinear refractive indices were carried out using the Z-scan method with a tunable dye laser pumped by a frequency doubled mode-locked Nd:YAG laser. The dye laser had a 4.5 ps pulse duration time and 76 MHz pulse repetition rate (575 nm).

Williams, E. K.↗

Third Order Optical Nonlinearity of Colloidal Metal Nanoclusters Formed by MeV Ion Implantation

We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO(sub 3) crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 deg C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width).The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO(sub 3) sample produced at five times less fluence is on average two times greater than that of the reference.

Sarkisov, S. S.↗

Thermally Stable, Piezoelectric and Pyroelectric Polymeric Substrates

A thermally stable, piezoelectric and pyroelectric polymeric substrate was prepared. This thermally stable, piezoelectric and pyroelectric polymeric substrate may be used to prepare electromechanical transducers, thermomechanical transducers, accelerometers. acoustic sensors, infrared sensors, pressure sensors, vibration sensors, impact sensors, in-situ temperature sensors, in-situ stress/strain sensors, micro actuators, switches, adjustable fresnel lenses, speakers, tactile sensors. weather sensors, micro positioners, ultrasonic devices, power generators, tunable reflectors, microphones, and hydrophones. The process for preparing these polymeric substrates includes: providing a polymeric substrate having a softening temperature greater than 1000 C; depositing a metal electrode material onto the polymer film; attaching a plurality of electrical leads to the metal electrode coated polymeric substrate; heating the metal electrode coated polymeric substrate in a low dielectric medium; applying a voltage to the heated metal electrode coated polymeric substrate to induce polarization; and cooling the polarized metal electrode coated polymeric electrode while maintaining a constant voltage.

Simpson, Joycely O.↗

Laser-Induced Fluorescence Measurements of Translational Temperature and Relative Cycle Number by use of Optically Pumped Trace-Sodium Vapor

Sodium fluorescence induced by a narrow bandwidth tunable laser has been used to measure temperature, pressure, axial velocity and species concentrations in wind tunnels, rocket engine exhausts and the upper atmosphere. Optical pumping of the ground states of the sodium, however, can radically alter the shape of the laser induced fluorescence excitation spectrum, complicating such measurements. Here a straightforward extension of rate equations originally proposed to account for the features of the pumped spectrum is to make temperature measurements from spectra taken in pumped vapor. Also determined from the spectrum is the relative fluorescence cycle number, which has application to measurement of diffusion rate and transverse flow velocity. The accuracy of both the temperature and cycle-number measurements is comparable with that of temperature measurements made in the absence of pumping.

Dobson, Chris C.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

Laser-Induced Fluorescence Measurements of Translational Temperature and Relative Cycle Number by use of Optically Pumped Trace-Sodium Vapor

Sodium fluorescence induced by a narrow-bandwidth tunable laser has been used to measure temperature, pressure, axial velocity, and species concentrations in wind tunnels, rocket engine exhausts, and the upper atmosphere. Optical pumping of the ground states of the sodium, however, can radically alter the shape of the laser-induced fluorescence excitation spectrum, complicating such measurements. Here a straightforward extension of rate equations originally proposed to account for the features of the pumped spectrum is used to make temperature measurements from spectra taken in pumped vapor. Also determined from the spectrum is the relative fluorescence cycle number, which has application to measurement of diffusion rate and transverse flow velocity, The accuracy of both the temperature and the cycle-number measurements is comparable with that of temperature measurements made in the absence of pumping.

Dobson, Chris C.↗

Coupling Factor Determination in the Control of Unintentionally Generated RF Fields

Radiated emissions and susceptibility requirements imposed in bands where intentional RF reception or transmission does not occur is problematical. It is often desired to compare radiated emissions with radiated susceptibility performance to assess system level compatibility. For reasons purely theoretical and because of practical measurement limitations, this not realistic. McCollum and Clark proposed a limit and test method that provided a direct comparison of radiated emissions and radiated susceptibility performance in those cases where only unintentional emissions and reception are of interest (non-tunable electronics). This test method, referred to as bulk current emissions (BCE) testing, and its associated limit is a complementary test method to bulk current injection testing and radiated susceptibility testing. Previous work utilized victim and culprit circuits with low common-mode loop impedance. Forward work identified in this publication was to determine how different loop impedance on culprit and victim circuits affected cable-to-cable coupling and the corresponding BCE test limit. Cable coupling factors for victim and culprit circuits with different loop impedance are investigated.

McCollum, Matthew B.↗

Resonant Transmissive Modulator Construction for Use in Beam Steering Array

An agile electronically configurable optical beam steering device for use in directional free-space transmission of optical signals is described. The device design employs an array of tunable resonant transmissive modulators constructed from multi-layered stacks of electro-optically active dielectric materials. Each modulator may be individually configured to transmit an optical signal with a specific amount of phase and group velocity modulation. The resulting diffractive interactions between modulator outputs provide a method for directional optical signal transmission. Of particular focus within this presentation is the optimized design of the individual modulator. It is widely known that periodic multi-layered stacks of dielectric materials exhibit reflective and transmissive resonances as described by the stack's transmission function. If an electric field is applied normal to the stack's layers, phenomena such as the electro-optic effect and/or the quantum-confined Stark effect may be employed to change the effective refractive index within the stack. This refractive index change alters the stack's transmission function and modulates the phase and group velocity of the transmitted optical signal. By varying the parameters that describe the stack's specific construction and operation, such as number of layers within the stack, refractive indexes of stack materials, layer thicknesses, and combinations of periodic verses non-periodic layer repetitions, custom transmittance functions may be generated. The transmitted optical signal carrier frequency and bandwidth must be carefully selected to maximize transmission and to minimize absorption. A computational optimization of the variables describing the stack's construction strives to maximize the amount of optical signal modulation verses applied voltage. Trade-offs between methods of increasing device performance verses the limitations of fabrication technologies are considered.

Keys, Andrew S.↗

Engine Test and Measurements

Although the importance of aerosols and their precursors are now well recognized, the characterization of current subsonic engines for these emissions is far from complete. Furthermore, since the relationship of engine operating parameters to aerosol emissions is not known, extrapolation to untested and unbuilt engines necessarily remains highly uncertain. 1997 NASA LaRC engine test, as well as the parallel 1997 NASA LaRC flight measurement, attempts to address both issues by expanding measurements of aerosols and aerosol precursors with fuels containing different levels of fuel sulfur content. The specific objective of the 1997 engine test is to obtain a database of sulfur oxides emissions as well as the non-volatile particulate emission properties as a function of fuel sulfur and engine operating conditions. Four diagnostic systems, extractive and non-intrusive (optical), will be assembled for the gaseous and particulate emissions characterization measurements study. NASA is responsible for the extractive gaseous emissions measurement system which contains an array of analyzers dedicated to examining the concentrations of specific gases (NO, NO(x), CO, CO2, O2, THC, SO2) and the smoke number. University of Missouri-Rolla uses the Mobile Aerosol Sampling System to measure aerosol/particulate total concentration, size distribution, volatility and hydration property. Air Force Research Laboratory uses the Chemical Ionization Mass Spectrometer to measure SO2, SO3/H2SO4, and HN03 Aerodyne Research, Inc. uses Infrared Tunable Diode Laser system to measure SO2, SO3, NO, H2O, and CO2.

Wey, Chown Chou↗

Infrared Laser System for Extended Area Monitoring of Air Pollution

An atmospheric pollution monitoring system using a spectrally scanning laser has been developed by the General Electric Company. This paper will report on an evaluation of a breadboard model, and will discuss applications of the concept to various ambient air monitoring situations. The system is adaptable to other tunable lasers. Operating in the middle infrared region, the system uses retroreflectors to measure average concentrations over long paths at low, safe power levels. The concept shows promise of meeting operational needs in ambient air monitoring and providing new data for atmospheric research.

Snowman, L. R.↗