Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Artemis I Flight Instrumentation Data Quality Assessment and Processing

This paper is in support of the SciTech 2024 Space Launch System Aerosciences Special Sessions being organized by Brent Pomeroy and Jeremy Pinier. On November 16th, 2022, NASA launched the inaugural test flight of the Space Launch System (SLS) carrying the Orion capsule into a high orbit far beyond the Moon. The launch vehicle was instrumented with over three thousand flight instrumentation sensors, which monitored aerodynamic, acoustic, structural, and thermal environments. These data are intended to validate experimental and numerical tools used to predict the design environments which the vehicle experiences during launch and ascent. Prior to launch, tests were performed at the SLS Systems Integration Laboratory (SIL) using flight-like avionics and on the integrated flight hardware of Artemis I at the Vehicle Assembly Building (VAB). The purpose of these tests was to characterize the data acquisition units (DAUs) used to record and telemeter flight data to ground stations in order to assure that flight test objectives can be achieved and to quantify the expected quality of the flight data. In addition, pre-flight assessment and development of tools and methods used to process and disseminate flight data at the Huntsville Operations Support Center (HOSC) were conducted and adjustments made with respect to DAU time-synchronization prior to and after the flight. This paper summarizes these tests and some aspects of the post processing of data are discussed.

Developmental Flight Instrumentation↗

Machine-Learning-aided Approach for Predicting the Thermal Expansion Behaviors in Advanced Test Reactor Capsules (NURETH-20 full paper)

Instrumented experiments at test reactors are essential to deploying new advanced reactor systems. Designing new experiments and generating data on specific conditions require both time and cost investment. A high-fidelity model of the experiment environment can be created using finite element analysis software to support the actual experiments, but computation time is still a concern in applying outcomes to real-time usage (e.g., a digital twin). This research proposes a machine-learning-aided approach to temperature and displacement predictions, based on the thickness of the outer gas gap on the experimental capsule used for the in-pile demonstration of a novel thermal conductivity probe in the Advanced Test Reactor. The capsule consisted of U10Zr fuel, a rodlet, sodium, and inner and outer capsules. There were gas gaps between the fuel and rodlet and between the inner and outer capsule. The learning data consisted of an experimental capsule’s radial distributions of temperature and displacement, as obtained from Abaqus and the physical features. For the first step, temperature was predicted using three positional parameters. Then the displacement was predicted using six different positional parameters. Each physical feature was normalized to be both nondimensional and standardized. The temperature and displacement predictions showed good agreement in all cases involving interpolation and extrapolation. Also, data similarity enhancement increased the similarity between training and target data increasing the predictive accuracy of machine-learning models. In some cases of extrapolation, the accuracy of the machine-learning model showed limited performance, but still data similarity enhancement improved the accuracy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NOAA-20 VIIRS Thermal Emissive Bands On-Orbit Performance

The VIIRS (Visible Infrared Imaging Radiometer Suite) instrument onboard the NOAA-20 satellite (launched on November 18, 2017) started to collect Earth-view data after its nadir door opened on December 13, 2017. Seven of the VIIRS bands, I4-5 and M12-16 are thermal emissive bands (TEBs), covering a spectral range from 3.6 to 12.5 meters. They began collecting valid data after the cold focal plane assembly (CFPA) cooled down to its nominal operating temperature on January 6, 2018. This paper will present the performance of each TEB, including calibration coefficients, noise equivalent differential temperature (NEdT), on-orbit calibration coefficient estimates from scheduled onboard blackbody warm-up and cool-down (WUCD) data, as well as related telemetry temperatures. Several methods are tested and compared in the WUCD data analysis for estimating the calibration coefficients. Based on the preliminary results, the NEdT of each band is well below the design specification and very close to that of the VIIRS onboard the Suomi National Polar-orbiting Partnership (SNPP) satellite. The detector gains appear stable for bands on the short- and mid-wave infrared CFPA, whereas the detector gains have larger than expected degradation for bands on the long-wave infrared CFPA during the early mission. All TEB-related telemetry temperatures are stable. The on-orbit performance of NOAA-20 VIIRS TEB is compared with VIIRS onboard the SNPP.

Thermal Emissive Bands (TEB)↗

Thermal Analysis of the MC-1 Chamber/Nozzle

This paper will describe the thermal analysis techniques used to predict temperatures in the film-cooled ablative rocket nozzle used on the MC-1 60K rocket engine. A model was developed that predicts char and pyrolysis depths, liner thermal gradients, and temperatures of the bondline between the overwrap and liner. Correlation of the model was accomplished by thermal analog tests performed at Southern Research, and specially instrumented hot fire tests at the Marshall Space Flight Center. Infrared thermography was instrumental in defining nozzle hot wall surface temperatures. In-depth and outboard thermocouple data was used to correlate the kinetic decomposition routine used to predict char and pyrolysis depths. These depths were anchored with measured char and pyrolysis depths from cross-sectioned hot-fire nozzles. For the X-34 flight analysis, the model includes the ablative Thermal Protection System (TPS) material that protects the overwrap from the recirculating plume. Results from model correlation, hot-fire testing, and flight predictions will be discussed.

Davis, Darrell W.↗

Thermal Analysis of the Fastrac Chamber/Nozzle

This paper will describe the thermal analysis techniques used to predict temperatures in the film-cooled ablative rocket nozzle used on the Fastrac 60K rocket engine. A model was developed that predicts char and pyrolysis depths, liner thermal gradients, and temperatures of the bondline between the overwrap and liner. Correlation of the model was accomplished by thermal analog tests performed at Southern Research, and specially instrumented hot fire tests at the Marshall Space Flight Center. Infrared thermography was instrumental in defining nozzle hot wall surface temperatures. In-depth and outboard thermocouple data was used to correlate the kinetic decomposition routine used to predict char and pyrolysis depths. These depths were anchored with measured char and pyrolysis depths from cross-sectioned hot-fire nozzles. For the X-34 flight analysis, the model includes the ablative Thermal Protection System (TPS) material that protects the overwrap from the recirculating plume. Results from model correlation, hot-fire testing, and flight predictions will be discussed.

Davis, Darrell↗

Preliminary assessment of Termoskan observations of Mars

The limited set of high-resolution observations of the 8-12 micron thermal emission from Mars' equatorial regions by the Termoskan instrument onboard the Phobos '88 spacecraft in February and March of 1989 is considered. Observations were also simultaneously acquired in the 0.5 to 1.0 micron region. A combined U.S. and Soviet scientific team made a preliminary quantitative evaluation of about 25 percent of the entire data set. It is found that there is a close agreement with the Viking Infrared Thermal Mapper brightness temperatures, confirming the accuracy of the Termoskan system and calibration. A novel pattern of emission from particles was observed in the morning and assumed to be water or ice. Thermal emission from surface features is varied and distinct down to the limit of resolution. The presence of unusually insulating material has been detected in the uppermost fraction of a millimeter of the Martian surface in places where the shadow of Phobos briefly eclipsed by the surface.

Murray, B.↗

From Concept-to-Flight: An Active Active Fluid Loop Based Thermal Control System for Mars Science Laboratory Rover

The Mars Science Laboratory (MSL) rover, Curiosity, which was launched on November 26, 2011, incorporates a novel active thermal control system to keep the sensitive electronics and science instruments at safe operating and survival temperatures. While the diurnal temperature variations on the Mars surface range from -120 C to +30 C, the sensitive equipment are kept within -40 C to +50 C. The active thermal control system is based on a single-phase mechanically pumped fluid loop (MPFL) system which removes or recovers excess waste heat and manages it to maintain the sensitive equipment inside the rover at safe temperatures. This paper will describe the entire process of developing this active thermal control system for the MSL rover from concept to flight implementation. The development of the rover thermal control system during its architecture, design, fabrication, integration, testing, and launch is described.

heat rejection systems↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

Evaluation of VIIRS and MODIS Thermal Emissive Band Calibration Stability Using Ground Target

The S-NPP Visible Infrared Imaging Radiometer Suite (VIIRS) instrument, a polar orbiting Earth remote sensing instrument built using a strong MODIS background, employs a similarly designed on-board calibrating source - a V-grooved blackbody for the thermal emissive bands (TEB). The central wavelengths of most VIIRS TEBs are very close to those of MODIS with the exception of the 10.7 micron channel. To ensure the long term continuity of climate data records derived using VIIRS and MODIS TEB, it is necessary to assess any systematic differences between the two instruments, including scenes with temperatures significantly lower than blackbody operating temperatures at approximately 290 K. Previous work performed by the MODIS Characterization Support Team (MCST) at NASAGSFC used the frequent observations of the Dome Concordia site located in Antarctica to evaluate the calibration stability and consistency of Terra and Aqua MODIS over the mission lifetime. The near-surface temperature measurements from an automatic weather station (AWS) provide a direct reference useful for tracking the stability and determining the relative bias between the two MODIS instruments. In this study, the same technique is applied to the VIIRS TEB and the results are compared with those from the matched MODIS TEB. The results of this study show a small negative bias when comparing the matching VIIRS and Aqua MODIS TEB, implying a higher scene temperature retrieval for S-VIIRS at the cold end. Statistically no significant drift is observed for VIIRS TEB performance over the first 3.5 years of the mission.

Madhavan, Sriharsha↗

Thermal Conductivity and Specific Heat Measurements of Candidate Structural Materials for the JWST Optical Bench

The James Webb Space Telescope will include an optical bench known as the integrated science instrument module (ISIM). Candidate structural materials for the ISIM must have low density, high stiffness, high thermal conductivity, and low thermal expansion coefficient at the operating temperature of 30 Kelvin. The specific heat is also important in modeling the on-orbit cooldown. We built two different systems for measuring the thermal conductivity and specific heat of samples between 4 Kelvin and 290 Kelvin. Both experiments were carefully designed to minimize potential errors due to radiative heat transfer. We chose the cooling system and instrumentation to allow long-term unattended operation. Software was developed to automate each experiment. It used an algorithm designed to ensure that each system was in thermal equilibrium before a measurement was taken. We describe the two experiments and present the data.

Canavan, E. R.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Update on Integrated Optical Design Analyzer

Updated information on the Integrated Optical Design Analyzer (IODA) computer program has become available. IODA was described in Software for Multidisciplinary Concurrent Optical Design (MFS-31452), NASA Tech Briefs, Vol. 25, No. 10 (October 2001), page 8a. To recapitulate: IODA facilitates multidisciplinary concurrent engineering of highly precise optical instruments. The architecture of IODA was developed by reviewing design processes and software in an effort to automate design procedures. IODA significantly reduces design iteration cycle time and eliminates many potential sources of error. IODA integrates the modeling efforts of a team of experts in different disciplines (e.g., optics, structural analysis, and heat transfer) working at different locations and provides seamless fusion of data among thermal, structural, and optical models used to design an instrument. IODA is compatible with data files generated by the NASTRAN structural-analysis program and the Code V (Registered Trademark) optical-analysis program, and can be used to couple analyses performed by these two programs. IODA supports multiple-load-case analysis for quickly accomplishing trade studies. IODA can also model the transient response of an instrument under the influence of dynamic loads and disturbances.

Moore, James D., Jr.↗

Development and Implementation of a Generic Analysis Template for Structural-Thermal-Optical-Performance Modeling

Performance-related effects of system level temperature changes can be a key consideration in the design of many types of optical instruments. This is especially true for space-based imagers, which may require complex thermal control systems to maintain alignment of the optical components. Structural-Thermal-Optical-Performance (STOP) analysis is a multi-disciplinary process that can be used to assess the performance of these optical systems when subjected to the expected design environment. This type of analysis can be very time consuming, which makes it difficult to use as a trade study tool early in the project life cycle. In many cases, only one or two iterations can be performed over the course of a project. This limits the design space to best practices since it may be too difficult, or take too long, to test new concepts analytically. In order to overcome this challenge, automation, and a standard procedure for performing these studies is essential. A methodology was developed within the framework of the Comet software tool that captures the basic inputs, outputs, and processes used in most STOP analyses. This resulted in a generic, reusable analysis template that can be used for design trades for a variety of optical systems. The template captures much of the upfront setup such as meshing, boundary conditions, data transfer, naming conventions, and post-processing, and therefore saves time for each subsequent project. A description of the methodology and the analysis template is presented, and results are described for a simple telescope optical system.

Scola, Salvatore↗

Rigid lightweight optical bench for a spaceborne FUV spatial heterodyne interferometer

Requirements for spaceflight optical instruments usually dictate that for the structures be rigid, lightweight, and thermally stable. In addition, for interferometric far ultraviolet (FUV) spectrometers, the requirements for torsional deflection are more severe than with conventional spectrometers. To meet the challenge for rigid and lightweight optical instruments, this paper explores the design of a high-stiffness structure for the support of an FUV spatial heterodyne interferometer where the torsional deflection of the instrument is on the order of 10 arc seconds. The structure is based on use of a thin, hollow section beam with weight-relieving between optical elements. The design also uses a modular and self-contained positioning mechanism that is removed after final optical alignment. Several specific material properties are presented as criteria for material selection. The parameters which affect the particular design requirements are identified with respect to the desired material properties and physical design features. Although large thin sections are susceptible to thermal gradients, this could be minimized by a trade-off for weight, where adequate margin exists. This paper describes the preliminary design for the structure and presents an analysis to verify compliance with the requirements.

Tom, James L.↗

FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials

The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.

Mattson, C. B.↗

Mars 2020 Surface Mission Modeling Landing Site Thermal Environments

This paper presents work done by the Mars 2020 Mission Planning Team to characterize landing site thermal environments. A process was developed to take in ground temperature simulation data for each landing site and efficiently discretize it into six thermal environment bins. The Mars 2020 Thermal Team then performed detailed heater and energy modeling in each of those environments. The heater modeling results were implemented into a Monte Carlo based surface mission model to understand mission performance impacts. The Mars 2020 Instrument Teams used the results to inform their design and to better understand how the thermal conditions at each landing site affected their instruments.

Lange, Robert D.↗

Mars 2020 Surface Mission Modeling Landing Site Thermal Environments

This paper presents work done by the Mars 2020 Mission Planning Team to characterize landing site thermal environments. A process was developed to take in ground temperature simulation data for each landing site and efficiently discretize it into six thermal environment bins. The Mars 2020 Thermal Team then performed detailed heater and energy modeling in each of those environments. The heater modeling results were implemented into a Monte Carlo based surface mission model to understand mission performance impacts. The Mars 2020 Instrument Teams used the results to inform their design and to better understand how the thermal conditions at each landing site affected their instruments.

Lange, Robert D.↗

Mars 2020 Surface Mission Modeling: Landing Site Thermal Environments

This paper presents work done by the Mars 2020 Mission Planning Team to characterize landing site thermal environments. A process was developed to take in ground temperature simulation data for each landing site and efficiently discretize it into a handful of thermal bin environments. The Mars 2020 Thermal Team then performed detailed heater and energy modeling in each of those environments. The heater modeling results were implemented into a Monte Carlo based surface mission model to understand mission performance impacts. The Mars 2020 Instrument Teams used the results to inform their design and to better understand how the thermal conditions at each landing site affected their instruments.

Lange, Robert D.↗