Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots

The cultivation of sterile giant miscanthus (Miscanthus × giganteus, M × g) for bioenergy and bioproducts has expanded into grain-cropped land in the United States (US) as local markets developed for this high-yielding perennial grass (10–30 Mg DM ha −1 ). However, the magnitude of spatial and temporal variability in yield within US Corn Belt fields, along with impacts on economic return and sustainable land management, is poorly understood. This study established a diagnostic model relating remote sensing-derived vegetation indices to ground truth data from 105 hand-harvested stem biomass samples, which were strategically selected to represent the full range of vegetation index observations. The high-resolution satellite-sensed vegetation indices captured > 90% of the yield variation measured within fields. This model was then used to predict yield variability and assess economic performance across four of the first commercial M × g fields in the Corn Belt state of Iowa, US. Significant spatial variability in biomass dry matter (DM) yields (9.3–18.1 Mg DM ha −1 ) and net profits ($\$$83 to $\$$1211.5 ha −1 ) was observed. All fields were profitable in all site-years. When low profit occurred, it was explained by limited management experience of the crop in Iowa. The breakeven yield at a selling price of $\$$130 Mg −1 varied from 9.0–12.1 Mg ha −1 at 15% moisture content (7.6–10.3 Mg DM ha −1 ). Breakeven prices ranged from $\$$73 to $\$$122.4 Mg −1 , matching ranges used in the Department of Energy Billion Ton Report (US Department of Energy, 2023). Notably, M × g yield and profits were commensurate with grain crops particularly with favorable precipitation. This study provides insight on the M × g management “learning curve”, performance on marginal land and in drought conditions, and demonstrates that addressing yield gaps, reducing costs, and implementing precision agriculture strategies can enhance profitability. These findings emphasize the value of remote sensing technologies in guiding sustainable and competitive commercial-scale M × g production.

60 APPLIED LIFE SCIENCES↗

Vertical Wellbore Flow Monitoring for Assessing Spatial and Temporal Flow Relationships with a Dynamic River Boundary

A useful tool for identifying the temporal and spatial ambient wellbore flow relationships near a dynamic river boundary is to continuously monitor ambient vertical wellbore flow with an electromagnetic borehole flowmeter (EBF). This is important because the presence of the wellbore can result in significant mixing or exchange of groundwater vertically across the aquifer. Mixing or exchanging groundwater within the well-screen section can have significant impacts on the distribution of contaminants within the aquifer and adverse effects on the representativeness of groundwater samples collected from the monitoring well. EBF monitoring data collected from long, fully screened wells at Hanford’s 300-Area Integrated Field Research Challenge (IFRC) site, located ~260 to 290 m from the Columbia River, demonstrate that ambient vertical wellbore flow exhibits both a positive (direct) and inverse temporal relationship with periodic river-stage fluctuations over short distances. The ambient flow monitoring wells fully penetrate a highly transmissive unconfined aquifer that consists of unconsolidated coarse sediments of the Hanford formation. The spatial distribution of ambient vertical wellbore flows across the IFRC’s ~2,200 m2 well-field size indicates two general regions of inverse ambient wellbore flow behavior. The western region of the IFRC site is characterized by ambient vertical wellbore flows that are positively related to river-stage fluctuations. In contrast, the eastern region of the site exhibits ambient wellbore flows that are inversely related to river-stage fluctuations. The cause of this opposite relationship between ambient wellbore flows and river-stage changes is not completely understood; however, the positive relationships appear to be associated with high-energy Hanford formation flood deposits. These flood deposits have a well-defined northwest-southeast trend and are believed to coincide with a local paleochannel. This local paleochannel bisects the site and connects to larger, more regionally developed flood paleochannels that laterally connect to the north and south across the 300 Area and the Hanford Site. The inverse relationships are attributed to an erosional, subsurface high in the Hanford/Ringold formation contact between the IFRC site and the Columbia River. Under these complex hydrogeologic and hydrodynamic conditions, the behavior of ambient vertical wellbore flow in monitoring wells near a dynamic river boundary can have important implications for collecting groundwater-quality samples, for contributing to contaminant distribution and transport within an aquifer system, and for implementing effective remediation strategies.

54 ENVIRONMENTAL SCIENCES↗

Chapter 18: Learning and Tracking Ad Hoc Fiducial Markers in Spatial Augmented Reality

We describe a spatial augmented reality system with a tangible user interface used to control computer simulations of complex systems. In spatial augmented reality, the user’s physical space is augmented with projected imagery, blending real objects with projected information, and a tangible user interface enables users to manipulate physical objects as controllers for interactive visualizations. Our system learns ad hoc objects in the user’s environment as fiducial markers (i.e., objects that are visually recognized and tracked). When combined with simulation and visualization tools, these interfaces allow the user to control simulations or ensembles of simulations via physical objects using apt metaphors. While other research has leveraged the use of depth cameras, our system enables the use of standard cameras in readily available smartphones and webcams and has an implementation that runs completely in JavaScript in the web browser. We discuss the prerequisite object-recognition requirements for such tangible user interfaces and describe computer-vision and machine-learning algorithms meeting those requirements. We conclude by presenting example applications, which are also available online.

energy distribution↗

Spatial distribution of electrical properties for Al-doped ZnO films deposited by dc magnetron sputtering using various inert gases

Spatial distribution of electrical properties of Al-doped ZnO (AZO) films deposited by magnetron sputtering was investigated. To adjust the intensity of bombardment by high-energy particles, the AZO films were deposited using Ar, Kr, or Xe gas with varying plasma impedance. The spatial distribution of the electrical properties clearly depends on the sputtering gas. In the case of using Kr or Xe, the resistivity of the films in front of the target center and erosion areas was significantly enhanced, in contrast with Ar. This was attributed to an enhancement in bombardment damage due to the increased sputtering voltages required for Kr or Xe discharges. The increase in plasma impedance was due to the smaller coefficients for secondary-electron emission of the target surface by Kr or Xe impingements, which leads to the larger sputtering voltage.

36 MATERIALS SCIENCE↗

Comparison of theory with the experimental characterization of the spatial frequency response of interferometers using a binary pseudo-random array sample

Experimental evaluations of the surface height response of an interference microscope using a binary pseudo-random array test sample are compared with a theory based on a Fourier optics model. Measurements of key instrument characteristics, including the illumination, imaging, and obscuring apertures of three different Mirau objectives, support the theoretical calculations. Agreement between experimental and theoretical modeling confirms the predictability of the spatial frequency response for the purpose of specification and optimization of instrument configuration for specific metrology tasks. The results also provide confidence in methods of compensating for the decrease in instrument response with spatial frequency.

Calibration↗

The x-ray light valve: A low-cost, digital radiographic imaging system--Spatial resolution

An x-ray light valve (XLV) coupled with an optical scanner has the potential to meet the need for a low-cost, high quality digital imaging system for general radiography. The XLV/scanner concept combines three well-established, and hence, low-cost technologies: An amorphous selenium (a-Se) layer as an x-ray-to-charge transducer, a liquid crystal (LC) cell as an analog display, and an optical scanner for image digitization. The XLV consists of an a-Se layer and LC cell in a sandwich structure which produces an optical image in the LC layer upon x-ray exposure. The XLV/scanner system consists of an XLV in combination with an optical scanner for image readout. Here, the effect of each component on the spatial resolution of an XLV/scanner system is investigated. A theoretical model of spatial resolution of an XLV is presented based on calculations of the modulation transfer function (MTF) for a-Se and a LC cell. From these component MTFs, the theoretical MTF of the XLV is derived. The model was validated by experiments on a prototype XLV/scanner system. The MTF of the scanner alone was obtained by scanning an optical test target and the MTF of the XLV/scanner system was measured using x rays. From the measured MTF of the scanner, the theoretical MTF of the XLV/scanner system was established and compared with the experimental results. Good general agreement exists between experimental and theoretical results in the frequency range of interest for general radiography, although the theoretical curves slightly overstate the measured MTFs. The experimental MTF of the XLV was compared with the MTF of two clinical systems and was shown to have the capability to exceed the resolution of flat-panel detectors. From this, the authors can conclude that the XLV has an adequate resolution for general radiography. The XLV/scanner also has the potential to eliminate aliasing while maintaining a MTF that exceeds that of a flat-panel imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of XFCT imaging strategy for monitoring the spatial distribution of platinum-based chemodrugs: Instrumentation and phantom validation

Purpose: Developing an imaging method to directly monitor the spatial distribution of platinum-based (Pt) drugs at the tumor region is of critical importance for early assessment of treatment efficacy and personalized treatment. In this study, the authors investigated the feasibility of imaging platinum (Pt)-based drug distribution using x-ray fluorescence (XRF, a.k.a. characteristic x ray) CT (XFCT). Methods: A 5-mm-diameter pencil beam produced by a polychromatic x-ray source equipped with a tungsten anode was used to stimulate emission of XRF photons from Pt drug embedded within a water phantom. The phantom was translated and rotated relative to the stationary pencil beam in a first-generation CT geometry. The x-ray energy spectrum was collected for 18 s at each position using a cadmium telluride detector. The spectra were then used for the K-shell XRF peak isolation and sinogram generation for Pt. The distribution and concentration of Pt were reconstructed with an iterative maximum likelihood expectation maximization algorithm. The capability of XFCT to multiplexed imaging of Pt, gadolinium (Gd), and iodine (I) within a water phantom was also investigated. Results: Measured XRF spectrum showed a sharp peak characteristic of Pt with a narrow full-width at half-maximum (FWHM) (FWHM{sub K{alpha}1}= 1.138 keV, FWHM{sub K{alpha}2}= 1.052 keV). The distribution of Pt drug in the water phantom was clearly identifiable on the reconstructed XRF images. Our results showed a linear relationship between the XRF intensity of Pt and its concentrations (R{sup 2}= 0.995), suggesting that XFCT is capable of quantitative imaging. A transmission CT image was also obtained to show the potential of the approach for providing attenuation correction and morphological information. Finally, the distribution of Pt, Gd, and I in the water phantom was clearly identifiable in the reconstructed images from XFCT multiplexed imaging. Conclusions: XFCT is a promising modality for monitoring the spatial distribution of Pt drugs. The technique may be useful in tailoring tumor treatment regimen in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially resolved assessment of hepatic function using 99mTc-IDA SPECT

Purpose: 99mTc-iminodiacetic acid (IDA) hepatobiliary imaging is usually quantified for hepatic function on the entire liver or regions of interest (ROIs) in the liver. The authors presented a method to estimate the hepatic extraction fraction (HEF) voxel-by-voxel from single-photon emission computed tomography (SPECT)/CT with a 99mTc-labeled IDA agent of mebrofenin and evaluated the spatially resolved HEF measurements with an independent physiological measurement.Methods: Fourteen patients with intrahepatic cancers were treated with radiation therapy (RT) and imaged by 99mTc-mebrofenin SPECT before and 1 month after RT. The dynamic SPECT volumes were with a resolution of 3.9 × 3.9 × 2.5 mm{sup 3}. Throughout the whole liver with approximate 50 000 voxels, voxelwise HEF quantifications were estimated and compared between using arterial input function (AIF) from the heart and using vascular input function (VIF) from the spleen. The correlation between mean of the HEFs over the nontumor liver tissue and the overall liver function measured by Indocyanine green clearance half-time (T1/2) was assessed. Variation of the voxelwise estimation was evaluated in ROIs drawn in relatively homogeneous regions of the livers. The authors also examined effects of the time range parameter on the voxelwise HEF quantification.Results: Mean of the HEFs over the liver estimated using AIF significantly correlated with the physiological measurement T1/2 (r= 0.52, p= 0.0004), and the correlation was greatly improved by using VIF (r= 0.79, p < 0.0001). The parameter of time range for the retention phase did not lead to a significant difference in the means of the HEFs in the ROIs. Using VIF and a retention phase time range of 7–30 min, the relative variation of the voxelwise HEF in the ROIs was 10%± 6% of respective mean HEF.Conclusions: The voxelwise HEF derived from 99mTc-IDA SPECT by the deconvolution analysis is feasible to assess the spatial distribution of hepatic function in the liver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

SU-F-J-214: Dose Reduction by Spatially Optimized Image Quality Via Fluence Modulated Proton CT (FMpCT)

Purpose: Proton CT (pCT) is a promising imaging modality for reducing range uncertainty in image-guided proton therapy. Range uncertainties partially originate from X-ray CT number conversion to stopping power ratio (SPR) and are limiting the exploitation of the full potential of proton therapy. In this study we explore the concept of spatially dependent fluence modulated proton CT (FMpCT), for achieving optimal image quality in a clinical region of interest (ROI), while reducing significantly the imaging dose to the patient. Methods: The study was based on simulated ideal pCT using pencil beam (PB) scanning. A set of 250 MeV protons PBs was used to create 360 projections of a cylindrical water phantom and a head and neck cancer patient. The tomographic images were reconstructed using a filtered backprojection (FBP) as well as an iterative algorithm (ITR). Different fluence modulation levels were investigated and their impact on the image was quantified in terms of SPR accuracy as well as noise within and outside selected ROIs, as a function of imaging dose. The unmodulated image served as reference. Results: Both FBP reconstruction and ITR without total variation (TV) yielded image quality in the ROIs similar to the reference images, for modulation down to 0.1 of the full proton fluence. The average dose was reduced by 75% for the water phantom and by 40% for the patient. FMpCT does not improve the noise for ITR with TV and modulation 0.1. Conclusion: This is the first work proposing and investigating FMpCT for producing optimal image quality for treatment planning and image guidance, while simultaneously reducing imaging dose. Future work will address spatial resolution effects and the impact of FMpCT on the quality of proton treatment plans for a prototype pCT scanner capable of list mode data acquisition. Acknowledgement: DFG-MAP DFG - Munich-Centre for Advanced Photonics (MAP)

60 APPLIED LIFE SCIENCES↗

SU-F-T-315: Comparative Studies of Planar Dose with Different Spatial Resolution for Head and Neck IMRT QA

Purpose: To quantitatively investigate the planar dose difference and the γ value between the reference fluence map with the 1 mm detector-to-detector distance and the other fluence maps with less spatial resolution for head and neck intensity modulated radiation (IMRT) therapy. Methods: For ten head and neck cancer patients, the IMRT quality assurance (QA) beams were generated using by the commercial radiation treatment planning system, Pinnacle3 (ver. 8.0.d Philips Medical System, Madison, WI). For each beam, ten fluence maps (detector-to-detector distance: 1 mm to 10 mm by 1 mm) were generated. The fluence maps with larger than 1 mm detector-todetector distance were interpolated using MATLAB (R2014a, the Math Works,Natick, MA) by four different interpolation Methods: for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. These interpolated fluence maps were compared with the reference one using the γ value (criteria: 3%, 3 mm) and the relative dose difference. Results: As the detector-to-detector distance increases, the dose difference between the two maps increases. For the fluence map with the same resolution, the cubic spline interpolation and the bicubic interpolation are almost equally best interpolation methods while the nearest neighbor interpolation is the worst.For example, for 5 mm distance fluence maps, γ≤1 are 98.12±2.28%, 99.48±0.66%, 99.45±0.65% and 82.23±0.48% for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. For 7 mm distance fluence maps, γ≤1 are 90.87±5.91%, 90.22±6.95%, 91.79±5.97% and 71.93±4.92 for the bilinear, the cubic spline, the bicubic, and the nearest neighbor interpolation, respectively. Conclusion: We recommend that the 2-dimensional detector array with high spatial resolution should be used as an IMRT QA tool and that the measured fluence maps should be interpolated using by the cubic spline interpolation or the bicubic interpolation for head and neck IMRT delivery. This work was supported by Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

The possibility of identifying the spatial location of single dislocations by topo-tomography on laboratory setups

The spatial arrangement of single linear defects in a Si single crystal (input surface (111)) has been investigated by X-ray topo-tomography using laboratory X-ray sources. The experimental technique and the procedure of reconstructing a 3D image of dislocation half-loops near the Si crystal surface are described. The sizes of observed linear defects with a spatial resolution of about 10 μm are estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of the spatial profiles of all components of the quadratic susceptibility tensor {Chi}{sup 2} (z, 2{omega}; {omega}, {omega}) of a one-dimensionally inhomogeneous absorbing medium

For a one-dimensionally inhomogeneous plate whose linear dielectric properties are also inhomogeneous and are characterized by a diagonal permittivity tensor, it is proved that the spatial profiles of all components of the complex quadratic susceptibility tensor {Chi}{sup 2} (z, 2{omega}; {omega}, {omega}) responsible for the second harmonic generation can be uniquely determined, and an appropriate method is proposed. To implement this method, one should measure the complex coefficient of transformation of a fundamental plane wave incident on the plate into a reflected second-harmonic wave in a certain range of angles of incidence. By varying the plane of incidence of the wave and (or) its polarization and measuring the coefficients of transformation into s- and p-polarized waves of double frequency, one can uniquely determine the spatial profiles of all components of the quadratic susceptibility tensor. The method involves the measurement of the intensities of the second-harmonic waves generated under special conditions with the use of two auxiliary reference plates and thus allows one to avoid complicated phase measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental and theoretical studies of the spatial distribution of the ionization rate in a non-self-sustained discharge controlled by a fast electron beam

The spatial distribution of the current density of fast electrons and the ionization rate in a gap filled with atmospheric-pressure air under the conditions of a non-self-sustained discharge controlled by a fast electron beam were investigated. The experiments were carried out in a gas-discharge chamber with a grid electrode arranged in parallel to the exit window of the ionization source. Spatial variations in the current density of fast electrons resulting from the grid were measured. The propagation of the electron beam through the discharge system was simulated numerically by the Monte Carlo method in the so-called 'effective collision' approximation. The calculated results agree well with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonances of the Spatial Distribution of Dislocations upon Interaction with the Structural Order Parameter

The interaction of a structural subsystem with dislocations under the superposition of an elastic torsion strain and an additional uniaxial spatially nonuniform time-constant pressure is studied. The analysis is carried out within of Landau’s phenomenological theory with refusal of the approximation of constant magnitudes of irreducible vectors. The rise of spatial resonances of the dislocation density in these conditions is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data for Yield from Iowa’s first commercial miscanthus fields: implications of spatial variability for productivity and sustainability beyond research plots

This dataset contains biomass yield measurements and associated vegetation index data collected from commercial Miscanthus × giganteus fields in eastern Iowa during the 2022–2023 growing seasons. The data support the analyses presented in the article: “Yield From Iowa's First Commercial Miscanthus Fields: Implications of Spatial Variability for Productivity and Sustainability Beyond Research Plots.” We collected 105 ground-truth biomass samples from four mature commercial fields (>4 years old) covering 92.81 ha. Samples were taken from 3 m² quadrats that were hand-harvested in alignment with commercial harvest timing. Stem biomass (excluding leaves) was weighed, moisture-corrected, and converted to dry-matter yield expressed in Mg DM ha⁻¹. Sampling locations were selected to capture spatial variability visible in aerial imagery and were recorded using RTK GPS. Each biomass observation was paired with vegetation indices derived from high-resolution PlanetScope satellite imagery (3 m resolution). Images were acquired throughout the growing season, and indices were calculated to evaluate their ability to predict end-of-season biomass yield. Statistical and machine learning approaches were used to identify key predictors, and a linear regression model based on end-of-July Green Normalized Difference Vegetation Index (GNDVI) was developed and evaluated. This repository includes the data used in that modeling workflow. Management practices, economic data, full imagery time series, and additional methodological details are described in the associated publication and are not included here. The dataset consists of three comma-separated value (CSV) files: 1. Combine_Groundtruth_Yield_VI_22_23.csv This file contains ground-truth biomass yield measurements and associated key vegetation index values collected during the 2022 and 2023 growing seasons. Rows: 105 observations Columns: Year — Year of observation (2022 or 2023) Field — Field location identifier Sample_number — Unique sample identifier GNDVI_End_Jul — Green Normalized Difference Vegetation Index calculated at end of July GNDVI_End_Aug — Green Normalized Difference Vegetation Index calculated at end of August NDRE_End_Aug — Normalized Difference Red Edge index calculated at end of August Biomass_Stem_Yield_MgDM/ha — Measured stem biomass yield (megagrams dry matter per hectare) 2. trainData_GNDVI.csv This file contains the subset of observations used to train the predictive relationship between July GNDVI and biomass yield. Rows: 76 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Stem_Yield_MgDM/ha — Observed stem biomass yield (Mg DM ha⁻¹) 3. testData_GNDVI.csv This file contains the test dataset used to evaluate model performance. Rows: 29 observations Columns: Unnamed: 0 — Row index retained from the original data processing workflow GNDVI_End_Jul — GNDVI at end of July Predicted_Yield_MgDM/ha — Model-predicted stem biomass yield (Mg DM ha⁻¹) Observed_Yield_MgDM/ha — Measured stem biomass yield (Mg DM ha⁻¹)

Potential yield, yield gap, in-field management, y↗

Cumulative Spatial Impact Layers™

Cumulative Spatial Impact Layers™ (CSIL) is a GIS-based tool that summarizes spatio-temporal datasets based on overlapping features and attributes. Applying a recursive quadtree method and multiple additive frameworks, the CSIL tool allows users to analyze raster and vector datasets simultaneously by calculating data, record, or attribute density. The CSIL tool was designed based on the original approach (Bauer et al. 2015) and more information on the tool overall along with applications can be found in Romeo et al. 2019). Providing an efficient summary of disparate geospatial data, CSIL bridges the gap between understanding data and analysis. Bauer, J. R., Nelson, J., Romeo, L., Eynard, J., Sim, L., Halama, J., Rose, K., & Graham, J. (2015). A spatio-temporal approach to analyze broad risks and potential impacts associated with uncontrolled hydrocarbon release events in the offshore Gulf of Mexico (NETL-TRS-2-2015 EPAct Technical Report Series). U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV; p 60. Romeo, L., Nelson, J., Wingo, P., Bauer, J., Justman, D., & Rose, K. (2019). Cumulative spatial impact layers: A novel multivariate spatio-temporal analytical summarization tool. Transactions in GIS.

Multivariate Visualization↗

2020 Transportation Research Board Workshop: Infrastructure Spatial Sensing at Intersections: The Potential to Enhance Safety and Enable Automation

The sensing technology that is enabling vehicle automation also can revolutionize traffic intersection safety, control, and efficiency. Infrastructure spatial sensing technology refers to the deployment of sensors that can detect and track all objects in the field of view - for example, mounting lidar sensors, radar, and video imaging at an intersection and fusing the data to produce a three-dimensional dynamic operational awareness. Combining such sensing capability with fail-safe vehicle communications can facilitate applications such as eco-approach and departure, optimizing efficient vehicle-signal coordination, and reducing traffic accidents through increasing safety. Furthermore, evidence is mounting suggesting that infrastructure-based sensing is needed in order to safely deploy automated public mobility alongside the normal vehicle and pedestrian traffic in our cities. Six speakers were invited to present their work from various aspects (safety, efficiency, and automation) addressing infrastructure-based sensing at the workshop on Infrastructure Spatial Sensing hosted in Washington DC as part of the Transportation Research Board Annual Meeting in January 12, 2019. A summary of the presentation are included herein.

47 OTHER INSTRUMENTATION↗