Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A Simulation and Optimization Framework for Managing Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability as measured by both acceleration and deformation, focusing on the stability differences between positive and negative tilt angles.

fluid structure interaction↗

Characterization of a novel 2D array dosimeter for patient-specific quality assurance with volumetric arc therapy

Purpose: In this study, the authors are evaluating a new, commercially available 2D array that offers 3D dose reconstruction for patient specific intensity modulated radiation therapy quality assurance (IMRT QA).Methods: The OCTAVIUS 4D system and its accompanying software (VERISOFT) by PTW were evaluated for the accuracy of the dose reconstruction for patient specific pretreatment IMRT QA. OCTAVIUS 4D measures the dose plane at the linac isocenter as the phantom rotates synchronously with the gantry, maintaining perpendicularity with the beam, by means of an inclinometer and a motor. The measurements collected during a volumetric modulated arc therapy delivery (VMAT) are reconstructed into a 3D dose volume. The VERISOFT application is used to perform the analysis, by comparing the reconstructed dose against the 3D dose matrix from the treatment planning system (TPS) that is computed for the same geometry and beam arrangement as that of the measurement. In this study, the authors evaluated the 3D dose reconstruction algorithm of this new system using a series of tests. Using the Octavius 4D phantom as the patient, dose distributions for various field sizes, beam orientations, shapes, and combination of fields were calculated using the Pinnacle3, TPS, and the respective DICOMRT dose was exported to the VERISOFT analysis software. Measurements were obtained by delivering the test treatment plans and comparisons were made based on gamma index, dose profiles, and isodose distribution analysis. In addition, output factors were measured and the dose linearity of the array was assessed. Those measurements were compared against measurements in water using a single, calibrated ionization chamber as well as calculations from Pinnacle for the same delivery geometries.Results: The number of voxels that met the 3%/3 mm criteria for the volumetric 3D gamma index analysis ranged from 92.3% to 98.9% for all the patient plans that the authors evaluated. 2D gamma analysis in the axial, sagittal, and coronal planes produced similar results to those in the 3D gamma analysis. The new detector system does not require an angular dependence correction because it rotates in synchrony with the gantry and the detector array maintains a constant SAD while always perpendicular to the beam axis. Output factors were within 2% when compared to ionization chamber measurements and Pinnacle calculations. Similar agreement was observed when testing the MU linearity (for MU values above 2) as well as dose rate effect.Conclusions: The OCTAVIUS 4D system has some unique characteristics that can potentially improve the patient specific pretreatment IMRT QA data collection and analysis. The ability of the software to reconstruct from the measurements the true 3D dose distribution in the phantom, provides a unique perspective for the medical physicist that evaluates a patient's QA plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-AB-204-04: Connectathons and Testing

You’ve experienced the frustration: vendor A’s device claims to work with vendor B’s device, but the practice doesn’t match the promise. Getting devices working together is the hidden art that Radiology and Radiation Oncology staff have to master. To assist with that difficult process, the Integrating the Healthcare Enterprise (IHE) effort was established in 1998, with the coordination of the Radiological Society of North America. Integrating the Healthcare Enterprise (IHE) is a consortium of healthcare professionals and industry partners focused on improving the way computer systems interconnect and exchange information. This is done by coordinating the use of published standards like DICOM and HL7. Several clinical and operational IHE domains exist in the healthcare arena, including Radiology and Radiation Oncology. The ASTRO-sponsored IHE Radiation Oncology (IHE-RO) domain focuses on radiation oncology specific information exchange. This session will explore the IHE Radiology and IHE RO process for; IHE solicitation process for new profiles. Improving the way computer systems interconnect and exchange information in the healthcare enterprise Supporting interconnectivity descriptions and proof of adherence by vendors Testing and assuring the vendor solutions to connectivity problems. Including IHE profiles in RFPs for future software and hardware purchases. Learning Objectives: Understand IHE role in improving interoperability in health care. Understand process of profile development and implantation. Understand how vendors prove adherence to IHE RO profiles. S. Hadley, ASTRO Supported Activity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Continuous Test and Transition Infrastructure for Quantum Networking for Science Complex

We propose a network architecture with a separate quantum dataplane and a conventional control plane: (a) Quantum Data Plane: The Quantum Data plane consists of links of dark fibers connecting quantum switches and repeaters, which in turn, connect to quantum computers, memory and sensors. Since the current reach is limited to local areas, it will begin as a collection of site networks at laboratories, (b) Conventional Control Plane: The Control plane provides management access to quantum devices for configuration and provisioning via control nodes with firewall and encryption capabilities. Continuous Test and Transition Infrastructure: We propose an infrastructure with a control plane connecting multiple sites via encrypted tunnels over conventional networks consisting of the following: (a) Site Quantum Networks: Individual site networks supported by their fiber plants connect laboratories that house and connect to their quantum devices for testing and interoperability.(b) Site Control Planes: Sites are connected over individual control planes with control hosts with Software Defined Networking capabilities, which can be peered with other networks via ESnet.(c) Progressive Expansion: Initially, sites will develop individual data planes with their specific quantum devices and fiber connections, and mechanisms to interface with conventional networks. They progressively expand and interconnect, under a wide-area ecosystem of peered control planes for device testing, interoperability development and roll off into production environments.

Rao, Nageswara S.↗

MEASUR - Manufacturing Energy Assessment Software for Utility Reduction

MEASUR your energy savings with the free DOE MEASUR software The Department of Energy (DOE), with Oak Ridge National Laboratory (ORNL), released version 1.0 of their energy efficiency software tool MEASUR (Manufacturing Energy Assessment Software for Utility Reduction). MEASUR has been available for several years as a beta version, being tested by industry experts and real users, and will continue to be updated and improved in the coming years. It is an integrated suite of tools to aid manufacturers in improving the efficiency of energy systems and equipment within a plant, including motors, pumps, fans, process heating, steam, and compressed air. Additionally, there are modules for wastewater energy analysis and to help perform energy treasure hunts. Several calculators are also included, allowing users to independently perform smaller calculations and analyses (such as estimating pump head, performing a fan traverse analysis, estimating waste heat recovery potential, and cataloging compressed air leaks). The MEASUR modules are based on previous DOE software tools that have been used by industry since the early 2000s (such as MotorMaster, AirMaster+, PSAT, PHAST, and FSAT). The original tools only ran on Windows operating systems, and by Windows 10, most of them were inoperable. DOE started their energy efficiency software tool revitalization effort in 2016, first with PSAT (for pumps), then began to integrate the other tools and expand their functionality and utility. The new MEASUR suite provides an extensively more user-friendly, modern, and versatile set of tools. All the assessment modules and most of the calculators have several visual components and graphs and detailed help text for every user input. To help reach international users, the tool utilizes Google translate and users can easily change unit systems, even converting existing user inputs if desired. The assessment files can be organized within the internal file system and easily shared to other users, regardless of their operating system. The entire suite is free, open-source, and can be downloaded on Windows, Mac, or Linux operating systems.

Accawi, Gina [Oak Ridge National Lab. (ORNL), Oak ↗

Simulating Wind-Driven Loading on PV Systems

As PV modules continue to trend toward larger, thinner, and more flexible forms they grow more susceptible to damage from dynamic wind loading. As a result, understanding the impact of wind on PV systems, particularly when mounted on compliant solar-tracking hardware, and identifying robust, stable array layouts and stow strategies is becoming increasingly important for the PV community. We are developing an open-source software package, PVade (PV aerodynamic design engineering), to simulate the cascading fluid-structure interaction that occurs within single-axis, solar-tracking arrays to enable researchers to test hardware, layout, and tracker control changes, leading to enhanced stability and a reduction in wind-driven damage. We will give an overview of the PVade software and present the latest outcomes from our ongoing validation campaign in which we compare time series and statistical structural responses with field data. From there, we will present simulated results from a larger, multi-row array and highlight the effect of varying tracker angles on stability and the differences between positive and negative tilt angles.

fluid↗

Integrated surface/subsurface permafrost thermal hydrology: Model formulation and proof-of-concept simulations

The need to understand potential climate impacts and feedbacks in Arctic regions has prompted recent interest in modeling of permafrost dynamics in a warming climate. A new fine-scale integrated surface/subsurface thermal hydrology modeling capability is described and demonstrated in proof-of-concept simulations. The new modeling capability combines a surface energy balance model with recently developed three-dimensional subsurface thermal hydrology models and new models for nonisothermal surface water flows and snow distribution in the microtopography. Surface water flows are modeled using the diffusion wave equation extended to include energy transport and phase change of ponded water. Variation of snow depth in the microtopography, physically the result of wind scour, is also modeled heuristically with a diffusion wave equation. The multiple surface and subsurface processes are implemented by leveraging highly parallel community software. Fully integrated thermal hydrology simulations on the tilted open book catchment, an important test case for integrated surface/subsurface flow modeling, are presented. Fine-scale 100-year projections of the integrated permafrost thermal hydrological system on an ice wedge polygon at Barrow Alaska in a warming climate are also presented. Finally, these simulations demonstrate the feasibility of microtopography-resolving, process-rich simulations as a tool to help understand possible future evolution of the carbon-rich Arctic tundra in a warming climate.

54 ENVIRONMENTAL SCIENCES↗

Sequential Monte Carlo sampling in hidden Markov models of nonlinear dynamical systems

We investigate the issue of which state functionals can have their uncertainty estimated efficiently in dynamical systems with uncertainty. Because of the high dimensionality and complexity of the problem, sequential Monte Carlo (SMC) methods are used. We investigate SMC methods where the proposal distribution is computed by maximum likelihood or by a linearization approach. We prove that the variance of the SMC method is bounded linearly in the number of time steps when the proposal distribution is truncated normal distribution. We also show that for a moderate large number of steps the error produced by approximation of dynamical systems linearly accumulates on the condition that the logarithm of the density function of noise is Lipschitz continuous. This finding is significant because the uncertainty in many dynamical systems, in particular, in chemical engineering systems, can be assumed to have this nature. We demonstrate our findings for a simple test case from chemical engineering. The theoretical findings provide a foundation for the parallel software SISTOS.

97 MATHEMATICS AND COMPUTING↗

Model development for flash boiling spray and validations with isooctane, hexane, ethanol and their binary mixtures

The objective of this study is to develop a comprehensive model for spray atomization under the consideration of flash boiling, which includes nucleation, bubble growth, and droplet breakup. Although flash boiling has been previously studied, there is still no well-established analytical and numerical model of their mechanisms, or general guidelines on the implementation of this atomization strategy. In this study, detailed formulations are elaborated for the unified spray atomization model under both non-flash and flash boiling conditions. Next, the model was implemented into CFD software and 3-D simulations were performed for model validations. Two fuel blends are tested: ethanol-isooctane blends and hexane-isooctane blends. Simulation results were compared with the experimental measurements conducted using two methodologies, DBI (Diffuse Backlight Imaging) system for spray images captured by a high-speed camera, and a PDA (Phase Doppler Anemometry) system for droplet size measurement during the spray injection process. It was found that the current flash boiling model can accurately capture the spray characteristics under different environment conditions, such as the spray plume interactions and liquid penetration. The averaged Sauter mean diameter (SMD) calculations match the measurement sufficiently well. The spray structures for both single- and multi-component fuels during the injection process are well represented by current model.

42 ENGINEERING↗

A distillation column for hydrogen isotope removal from liquid lithium

Recovery of tritium from plasma-facing components in fusion devices will be vital to future full-scale operation. Liquid, low-Z materials have demonstrated many inherent advantages over solid first wall materials. To this end, a thermal treatment method in the form of a distillation column for extraction of hydrogen isotopes from liquid lithium has been designed, developed, and constructed at the Center for Plasma-Material Interactions at the University of Illinois at Urbana-Champaign. Use of induction heating and lithium condensation stages are the two qualities that set this design apart from other thermal treatment systems. Induction heating capabilities were modeled using the COMSOL Multiphysics software, which were validated when commissioning the physical heater module. Proof-of-concept tests were performed in the prototype column, which were undertaken as batch processes to investigate the efficacy with which the column could remove hydrogen gas from lithium-rich and lithium hydride-rich samples. All of the tests reported used lithium hydride as a surrogate for lithium deuteride and lithium tritide. The design process and results from the initial tests will be discussed, along with the envisioned placement of this treatment scheme in a fully-functional lithium loop.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact, portable, automatic sample changer stick for cryostats and closed-cycle refrigerators

Beamlines are facilities that produce and deliver highly focused and intense beams of radiation, typically x rays, synchrotron radiation, or neutrons, for scientific research purposes. Millions of dollars are spent annually to maintain and operate these scientific beamlines, oftentimes running continuously between cycles. To reduce human intervention and improve productivity, mechanical sample changers are often commissioned for use. Designing sample changers is difficult because mechanical parts can be bulky, expensive, and challenging to design for instruments with low volume access, high radiation, and cryogenic environments. We present a portable and inexpensive sample changer stick that can hold and manipulate up to four samples, specifically designed for use with cryogenic closed-cycle refrigerators. The sample changer stick enables rapid and efficient exchange of samples without manual intervention, and is compatible with standard sample mounts such as vanadium cans. The sample changer stick includes a motorized rotation and lancing mechanism, which enables the precise positioning of each sample in the neutron beam, while ensuring compatibility with the operating temperatures and vacuum conditions required for closed-cycle refrigerators. The design has been successfully tested at the VISION beamline at the Spallation Neutron Source. The mechanical action and software controls are detailed. Furthermore, the sample changer stick is a valuable tool for scientists working with cryogenic closed-cycle refrigerators.

36 MATERIALS SCIENCE↗

BISON: A Flexible Code for Advanced Simulation of the Performance of Multiple Nuclear Fuel Forms

BISON is a nuclear fuel performance application built using the Multiphysics Object-Oriented Simulation Environment (MOOSE) finite element library. One of its major goals is to have a great amount of flexibility in how it is used, including in the types of fuel it can analyze, the geometry of the fuel being modeled, the modeling approach employed, and the dimensionality and size of the models. Fuel forms that can be modeled include standard light water reactor fuel, emerging light water reactor fuels, tri-structural isotropic fuel particles, and metallic fuels. BISON is a platform for research in nuclear fuel performance modeling while simultaneously serving as a tool for the analysis of nuclear fuel designs. Recent research in BISON includes techniques such as the extended finite element method for fuel cracking, exploration of high-burnup light water reactor fuel behavior, swelling behavior of metallic fuels, and central void formation in mixed-oxide fuel. BISON includes integrated documentation for each of its capabilities, follows rigorous software quality assurance procedures, and has a growing set of rigorous verification and validation tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-J-102: Performance Variations Among Clinically Available Deformable Image Registration Tools in Adaptive Radiotherapy: How Should We Evaluate and Interpret the Result?

Purpose: To evaluate the performance variations in commercial deformable image registration (DIR) tools for adaptive radiation therapy. Methods: Representative plans from three different anatomical sites, prostate, head-and-neck (HN) and cranial spinal irradiation (CSI) with L-spine boost, were included. Computerized deformed CT images were first generated using virtual DIR QA software (ImSimQA) for each case. The corresponding transformations served as the “reference”. Three commercial software packages MIMVista v5.5 and MIMMaestro v6.0, VelocityAI v2.6.2, and OnQ rts v2.1.15 were tested. The warped contours and doses were compared with the “reference” and among each other. Results: The performance in transferring contours was comparable among all three tools with an average DICE coefficient of 0.81 for all the organs. However, the performance of dose warping accuracy appeared to rely on the evaluation end points. Volume based DVH comparisons were not sensitive enough to illustrate all the detailed variations while isodose assessment on a slice-by-slice basis could be tedious. Point-based evaluation was over-sensitive by having up to 30% hot/cold-spot differences. If adapting the 3mm/3% gamma analysis into the evaluation of dose warping, all three algorithms presented a reasonable level of equivalency. One algorithm had over 10% of the voxels not meeting this criterion for the HN case while another showed disagreement for the CSI case. Conclusion: Overall, our results demonstrated that evaluation based only on the performance of contour transformation could not guarantee the accuracy in dose warping. However, the performance of dose warping accuracy relied on the evaluation methodologies. Nevertheless, as more DIR tools are available for clinical use, the performance could vary at certain degrees. A standard quality assurance criterion with clinical meaning should be established for DIR QA, similar to the gamma index concept, in the near future.

60 APPLIED LIFE SCIENCES↗

A Systematic Review and Meta-Analysis of Tai Chi Training in Cardiorespiratory Fitness of Elderly People

Objectives. The purpose of this study was to investigate the influence of Tai Chi on cardiorespiratory fitness (CRF) in elderly people using meta-analysis. Methods. This study used seven electronic databases and data retrieved from randomized controlled trials (RCTs) investigating the role of Tai Chi on CRF in the elderly. All these 24 RCTs were screened and selected from 7 literature databases. The Stata 11.2 software (StataCorp, USA) was used for the meta-analysis, subgroup analysis, and bias test, while the Cochrane Collaboration’s tool was used for the assessment of the risk of bias (RoB). 4 researchers independently participated in sample selection, data extraction, and RoB assessment. Results. Following the inclusion criteria, 24 eligible studies were included in our analysis. The meta-analysis indicated that Tai Chi practice significantly increased the maximum rate of oxygen consumption (VO2 max) (weighted mean difference (WMD) = 3.76, 95% CI: 1.25 to 6.26, P < 0.1 ), leading to an overall reduction in the heart rate (HR) (WMD = −1.84, 95% CI: −2.04 to −1.63, P ≤ 0.001 ) and an increase in the O2 pulse (WMD = 0.94, 95% CI: 0.60 to 1.28, P ≤ 0.001 ) in individuals who practiced Tai Chi regularly compared with those who did not. The subgroup analysis suggested that overall in those who practiced Tai Chi, males (WMD = 1.48, 95% CI: 0.85 to 2.12, P ≤ 0.001 ) had higher O2 pulse than females (WMD = 0.73, 95% CI: 0.33 to 1.12, P ≤ 0.001 ). The subgroup analysis also showed an increase in the vital capacity (VC) (WMD = 316.05, 95% CI: 239.74 to 392.35, P ≤ 0.001 ) in individuals practicing Tai Chi. When the samples were further stratified by Tai Chi practicing time, the subgroup analysis suggested that individuals practicing Tai Chi over a period of 24 weeks showed no significant difference in VC (WMD = 82.95, 95% CI: -98.34 to 264.23, P = 0.370 ), while those practicing Tai Chi over a period of 48 weeks showed a significant increase (WMD = 416.62, 95% CI: 280.68 to 552.56, P ≤ 0.001 ). Furthermore, the subgroup analysis demonstrated that the increase in VC is significantly correlated with the Tai Chi practicing time (WMD = 344.97, 95% CI: 227.88 to 442.06, P ≤ 0.001 ). Conclusion. Regular Tai Chi practice could improve the CRF in the elderly, as indicated by significant improvement in indicators including VO2max, O2pulse, VC, and HR. However, gender and practice time might influence the overall beneficial outcomes.

Tan, Tianyang↗

RAJA Performance Suite

The RAJA Performance Suite is designed to evaluate performance of the RAJA performance portability library on a wide variety of important high performance computing (HPC) algorithmic lulmels. These kernels assess compiler optimizations and various parallel programming model backends accessible through RAJA, such as OpenMP, CUDA, etc. The Initial version of the suite contains 25 computational kernels, each of which appears in 6 variants: Baseline SequcntiaJ, RAJA SequentiaJ, Baseline OpenMP, RAJA OpenMP, Baseline CUDA, RAJA CUDA. All variants of each kernel perform essentially the same mathematical operations and the loop body code for each kernel is identical across all variants. There are a few kernels, such as those that contain reduction operations, that require CUDA-specific coding for their CUDA variants. ActuaJ computer instructions executed and how they run in parallel differs depending on the parallel programming model backend used and which optimizations are perfonned by the compiler used to build the Perfonnance Suite executable. The Suite will be used primarily by RAJA developers to perform regular assessments of RAJA performance across a range of hardware platforms and compilers as RAJA features are being developed. It will also be used by LLNL hardware and software vendor panners for new defining requirements for future computing platform procurements and acceptance testing. In particular, the RAJA Performance Suite will be used for compiler acceptance testing of the upcoming CORAUSierra machine {initial LLNL delivery expected in late-2017/early 2018) and the CORAL-2 procurement. The Suite will aJso be used to generate concise source code reproducers of compiler and runtime issues we uncover so that we may provide them to relevant vendors to be fixed.

Hornung, RichardD.↗

WeightedAFL

WeightedAFL (WAFL) is an improvement to open source fuzzer, American Fuzzy Lop (AFL). Fuzzers modify input to target programs in order to produce crashes and other unintended output in those target programs. WAFL integrates directly with AFL to determine offsets within a buffer that will improve performance metrics. WAFL uses various machine learning techniques to learn these offsets. WAFL also provides a novel software engineering solution to integrate with AFL and allows contributors to quickly write and test algorithms in python. SAND2020-12546 O Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-NA0003525.

Kincher-Winoto, Kina↗

Wrapper for the optimization of cross-section generation in OpenMC

The "Wrapper for the optimization of cross-section generation in OpenMC" is Python-based software that runs the open-source Monte Carlo code OpenMC (https://docs.openmc.org/en/stable/ ) to generate cross-sections for any reactor geometry. The wrapper then optimizes those cross sections. The optimization aims to choose an energy group structure and a scattering representation that maximize accuracy with respect to continuous-energy results while avoiding significant computational expense. It then outputs these cross-sections in an ISOXML format readable by the Idaho National Lab code suite MOOSE (Olin William Calvin, Mark D DeHart, “Architecture for the Performance of Nuclear Fuel Depletion Calculations”, Idaho National Laboratory report, November 2019). The expected use-cases of this software include: -finding the best group structure and scattering representation for a specific reactor -testing the appropriateness of energy group structures for different reactor types -comparing energy group structures and scattering representations to each other -generating cross sections for use in deterministic codes, including ones found in the MOOSE suite The example reactor geometry included in this release is a generic reactor design, not based on any reactor in existence or in development. It was fabricated for the sole purpose of being a “testbed-geometry” upon which to develop this tool. Since the tool is designed to be generic, the nature of the test geometry is not very important, however, it is valuable to include as an example for users who are unfamiliar with developing reactor geometries for OpenMC.

Kreher, Miriam↗