Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “software differences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Characteristics and Energy Use of Volume Servers in the United States

Servers’ field energy use remains poorly understood, given heterogeneous computing loads, configurable hardware and software, and operation over a wide range of management practices. This paper explores various characteristics of 1- and 2-socket volume servers that affect energy consumption, and quantifies the difference in power demand between higher-performing SPEC and ENERGY STAR servers and our best understanding of a typical server operating today. We first establish general characteristics of the U.S. installed base of volume servers from existing IDC data and the literature, before presenting information on server hardware configurations from data collection events at a major online retail website. We then compare cumulative distribution functions of server idle power across three separate datasets and explain the differences between them via examination of the hardware characteristics to which power draw is most sensitive. We find that idle server power demand is significantly higher than ENERGY STAR benchmarks and the industry-released energy use documented in SPEC, and that SPEC server configurations—and likely the associated power-scaling trends—are atypical of volume servers. Next, we examine recent trends in server power draw among high-performing servers across their full load range to consider how representative these trends are of all volume servers before inputting weighted average idle power load values into a recently published model of national server energy use. Finally, we present results from two surveys of IT managers (n=216) and IT vendors (n=178) that illustrate the prevalence of more-efficient equipment and operational practices in server rooms and closets; these findings highlight opportunities to improve the energy efficiency of the U.S. server stock.

97 MATHEMATICS AND COMPUTING↗

2021 Radionuclide Air Emissions Report for Los Alamos National Laboratory, Revised October 2022

Provided is a revision to the Calendar Year 2021 Radionuclide Air Emissions Report for the Los Alamos National Laboratory (LANL). This report is a regulatory compliance deliverable for LANL under the Radionuclide NESHAP, 40 CFR 61 Subpart H. The revised report is needed to correct an error identified regarding generation of wind data files. These wind data files are used for plume modeling as part of calculating off-sites doses from monitored radionuclide air emissions sources. The error resulted from a software update by LANL’s meteorology team after new towers were added to the tower network. As a result of this error, incorrect wind frequencies were assigned to the different stability classes. This slightly affected the plume model calculations and subsequent off-site dose determinations for analyses using these wind files.

2021 Radionuclide, Air Emissions↗

Aeroelastic Modeling for Distributed Wind Turbines: March 11, 2021 - November 10, 2021

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine whereby providing an understanding of the impact of design parameters on its loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the Distributed Wind Technology (DWT) sector is limited, especially within the less established manufacturers. This project represents an in-depth assessment of the status of AM and its role within the Standards for the DWT industry. The study gathered input and feedback from a large number of national and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed recent industry workshops' and meetings' minutes, collected publicly available AM templates, and provided an evaluation of the existing AM codes. The study achieved several goals including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation (V&V), which includes discussions of measurement requirements and a sample test-plan useful for future V&V campaigns and design standard development. This document summarizes the different tasks conducted in the course of the project and highlights the steps required to improve the AM adoption based on a multifaceted approach that encompasses: 1) augmenting AM software capabilities, 2) publishing AM best-practices and design-basis, 3) creating new model templates, 4) providing guidance for V&V of codes and specific turbine models leveraging field testing best-practice, and 5) addressing weaknesses in the current standards. Many of the future objectives identified in this study could leverage NREL's upcoming testing campaigns of three modern distributed wind turbines. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool resulting in a more efficient design process, an easier path to certification, and overall better and more distributed reliable wind turbine products.

17 WIND ENERGY↗

A Computer Design Tool for Ceramic Receivers

Gen3 solar receivers and other components will experience a combination of high temperatures and high stress caused by thermal stress and internal pressure. Under these conditions metallic components, even those manufactured from nickel-based superalloys, have poor reliability. Engineering ceramics could be a solution, as these materials have excellent high temperature strength. However, accurately assessing the reliability of a ceramic component operating in these conditions requires an entirely different approach compared to metallic materials. This paper describes the implementation of statistical models for evaluating the reliability of high temperature ceramic components in srlife – an open-source software package for estimating the life of high temperature concentrating solar power equipment. This new capability allows users to make fair comparisons between competing metallic and ceramic component designs and to accurately assess the plant efficiency and economics of ceramic solar receivers and other components.

Messner, Mark (ORCID:0000000200404385)↗

Leveraging Shore-Side, Building Energy Simulation Tools for Use in the Shipboard Environment

Within the confines of the Maritime Prescreening Assessment of Conservation Technologies program, the U.S. Department of Energy's National Renewable Energy Laboratory, in collaboration with the Naval Surface Warfare Center Carderock and Philadelphia Divisions, the U.S. Department of Transportation's Maritime Administration, and the Massachusetts Maritime Academy, recently developed a physics-based modeling engine to evaluate non-propulsive ship energy consumption under different operational scenarios and technology applications, in order to enhance the Navy's ability to optimize ship operational reach and tactical performance. To accomplish this, a mature thermophysical modeling software, EnergyPlus TM , was modified for ship-related applications. This software, originally developed for use in whole-building energy consumption studies, is a free and open-source simulation program that has been used for more than two decades. The team evaluated the accuracy of the modified version of EnergyPlus by comparing results to direct measurements taken over a 6-week underway period onboard the Maritime Administration's Training Ship Kennedy. The team developed an energy model of a prescribed area of the ship and compared its performance to measured results obtained from 235 sensor points. EnergyPlus behaved well with respect to solar loading and convective heat transfer to seawater while the ship was underway. However, results suggest that additional work remains to accurately simulate seawater heat transfer while the ship is stationary.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-sensor fusion for robust autonomous flight in indoor and outdoor environments with a rotorcraft micro-aerial vehicle (MAV)

The subject matter described herein includes a modular and extensible approach to integrate noisy measurements from multiple heterogeneous sensors that yield either absolute or relative observations at different and varying time intervals, and to provide smooth and globally consistent estimates of position in real time for autonomous flight. We describe the development of the algorithms and software architecture for a new 1.9 kg MAV platform equipped with an IMU, laser scanner, stereo cameras, pressure altimeter, magnetometer, and a GPS receiver, in which the state estimation and control are performed onboard on an Intel NUC 3rd generation i3 processor. We illustrate the robustness of our framework in large-scale, indoor-outdoor autonomous aerial navigation experiments involving traversals of over 440 meters at average speeds of 1.5 m/s with winds around 10 mph while entering and exiting buildings.

42 ENGINEERING↗

Finite element analysis of the PWR control rod absorber thermal evaluation

The RCCAs (Rod Cluster Control Assembly) are part of the reactor control systems and are designed to adjust the reactivity by neutron absorption. In PWR, a RCCA is composed of a spider holding 24 control rods. During operation, the absorber stacks are heated up by neutron and γ-ray radiation. This paper describes the PWR control rod absorber temperature analysis model in details, derives the theoretical equations, and presents a FEA model for control rod absorber thermal evaluation. The FEA model is based on finite element analysis and on 3 major assumptions: 1) steady-state condition, 2) the thermal conductivities of absorber, cladding and gas are assumed to be constant, and 3) thermal expansion and radiation are neglected. The control rod of an AFA 3G fuel assembly in Ningde NPP unit 1 and 2 in steady state on condition I operation was used as a case to qualify the FEA method. A special software named CRABE, designed and qualified by AREVA, was used to do the same analysis for comparison. Several conclusions can be drawn. First, compared with traditional methods, FEA is more convenient with higher accuracy and can greatly simplify the calculation process. In addition, the FEA software is always ease to use, with a friendly interface and a more intuitive display of results. Secondly, the FEA model was qualified though a practical case calculated in different ways. Thirdly, when it comes to a special structure such as an eccentric absorber or an oval cladding, the FEA model has a great applicability, while traditional methods are difficult to use.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Tale from the Trenches: Applying Metamorphic and Differential Testing to Bioinformatics Software

Metamorphic and differential testing have been proposed as best practices for testing software that is difficult to test, such as for programs in scientific domains. An assumption is that these approaches can be easily customized and applied to almost any domain. However, scientific software is often data-driven, and metamorphic relations may require significant domain knowledge to develop. In addition, tools are often written for ad-hoc experimentation by the scientists and often embed many assumptions about the importance and representation of different natural phenomena. In this paper, we present our experience applying both metamorphic and differential testing to a set of four computational biology tools that predict the growth of an organism. While our original goal was to evaluate these techniques to improve our system-level testing, we encountered multiple roadblocks along the way. Although we did find faults (some confirmed by developers), we also uncovered a set of challenges, including the considerable manual effort required for (a) defining domain-specific tests, (b) validating correctness, and (c) distinguishing between issues stemming from poor data and those arising from incorrect software.

Marsh, Alexis L [Iowa State University/Ames Labora↗

WE-AB-202-04: Statistical Evaluation of Lung Function Using 4DCT Ventilation Imaging: Proton Therapy VS IMRT

Purpose: Variation in function of different lung regions has been ignored so far for conventional lung cancer treatment planning, which may lead to higher risk of radiation induced lung disease. 4DCT based lung ventilation imaging provides a novel yet convenient approach for lung functional imaging as 4DCT is taken as routine for lung cancer treatment. Our work aims to evaluate the impact of accounting for spatial heterogeneity in lung function using 4DCT based lung ventilation imaging for proton and IMRT plans. Methods: Six patients with advanced stage lung cancer of various tumor locations were retrospectively evaluated for the study. Proton and IMRT plans were designed following identical planning objective and constrains for each patient. Ventilation images were calculated from patients’ 4DCT using deformable image registration implemented by Velocity AI software based on Jacobian-metrics. Lung was delineated into two function level regions based on ventilation (low and high functional area). High functional region was defined as lung ventilation greater than 30%. Dose distribution and statistics in different lung function area was calculated for patients. Results: Variation in dosimetric statistics of different function lung region was observed between proton and IMRT plans. In all proton plans, high function lung regions receive lower maximum dose (100.2%–108.9%), compared with IMRT plans (106.4%–119.7%). Interestingly, three out of six proton plans gave higher mean dose by up to 2.2% than IMRT to high function lung region. Lower mean dose (lower by up to 14.1%) and maximum dose (lower by up to 9%) were observed in low function lung for proton plans. Conclusion: A systematic approach was developed to generate function lung ventilation imaging and use it to evaluate plans. This method hold great promise in function analysis of lung during planning. We are currently studying more subjects to evaluate this tool.

60 APPLIED LIFE SCIENCES↗

SU-F-J-180: A Reference Data Set for Testing Two Dimension Registration Algorithms

Purpose: To create and characterize a reference data set for testing image registration algorithms that transform portal image (PI) to digitally reconstructed radiograph (DRR). Methods: Anterior-posterior (AP) and Lateral (LAT) projection and DRR image pairs from nine cases representing four different anatomical sites (head and neck, thoracic, abdominal, and pelvis) were selected for this study. Five experts will perform manual registration by placing landmarks points (LMPs) on the DRR and finding their corresponding points on the PI using computer assisted manual point selection tool (CAMPST), a custom-made MATLAB software tool developed in house. The landmark selection process will be repeated on both the PI and the DRR in order to characterize inter- and -intra observer variations associated with the point selection process. Inter and an intra observer variation in LMPs was done using Bland-Altman (B&A) analysis and one-way analysis of variance. We set our limit such that the absolute value of the mean difference between the readings should not exceed 3mm. Later on in this project we will test different two dimension (2D) image registration algorithms and quantify the uncertainty associated with their registration. Results: Using one-way analysis of variance (ANOVA) there was no variations within the readers. When Bland-Altman analysis was used the variation within the readers was acceptable. The variation was higher in the PI compared to the DRR.ConclusionThe variation seen for the PI is because although the PI has a much better spatial resolution the poor resolution on the DRR makes it difficult to locate the actual corresponding anatomical feature on the PI. We hope this becomes more evident when all the readers complete the point selection. The reason for quantifying inter- and -intra observer variation tells us to what degree of accuracy a manual registration can be done. Research supported by William Beaumont Hospital Research Start Up Fund.

60 APPLIED LIFE SCIENCES↗

SU-E-T-215: Interactive Dose Shaping: Proof of Concept Study for Six Prostate Patients

Purpose: To provide a proof of concept study for IMRT treatment planning through interactive dose shaping (IDS) by utilising the respective tools to create IMRT treatment plans for six prostate patients. Methods: The IDS planning paradigm aims to perform interactive local dose adaptations of an IMRT plan without compromising already established valuable dose features in real-time. Various IDS tools are available in our in-house treatment planning software Dynaplan and were utilised to create IMRT treatment plans for six patients with an adeno-carcinoma of the prostate. The sequenced IDS treatment plans were compared to conventionally optimised clinically approved plans (9 beams, co-planar). The starting point consisted of open fields. The IDS tools were utilised to sculpt dose out of the rectum and bladder. For each patient, several IDS plans were created, with different trade-offs between organ sparing and target coverage. The reference dose distributions were imported into Dynaplan. For each patient, the IDS treatment plan with a similar or better trade-off between target coverage and OAR sparing was selected for plan evaluation, guided by a physician. Pencil beam dose calculation was performed on a grid with a voxel size of 1.95×1.95×2.0 mm{sup 3}. D98%, D2%, mean dose and dose-volume indicators as specified by Quantec were calculated for plan evaluation. Results: It was possible to utilise the software prototype to generate treatment plans for prostate patient geometries in 15–45 minutes. Individual local dose adaptations could be performed in less than one second. The average differences compared to the reference plans were for the mean dose: 0.0 Gy (boost) and 1.2 Gy (CTV), for D98%: −1.1 Gy and for D2%: 1.1 Gy (both target volumes). The dose-volume quality indicators were well below the Quantec constraints. Conclusion: Real-time treatment planning utilising IDS is feasible and has the potential to be implemented clinically. Research at The Institute of Cancer Research is supported by Cancer Research UK under Programme C46/A10588.

60 APPLIED LIFE SCIENCES↗

SU-E-J-27: Appropriateness Criteria for Deformable Image Registration and Dose Propagation

Purpose: Several commercial software packages have been recently released that allow the user to apply deformable registration algorithms (DRA) for image fusion and dose propagation. Although the idea of anatomically tracking the daily patient dose in the context of adaptive radiotherapy or merely adding the dose from prior treatment to the current one is very intuitive, the accuracy and applicability of such algorithms needs to be investigated as it remains somewhat subjective. In our study, we used true anatomical data where we introduced changes in the density, volume and location of segmented structures to test the DRA for its sensitivity and accuracy. Methods: The CT scan of a prostate patient was selected for this study. The CT images were first segmented to define structure such as the PTV, bladder, rectum, intestines and pelvic bone anatomy. To perform our study, we introduced anatomical changes in the reference patient image set in three different ways: (i) we kept the segmented volumes constant and changed the density of rectum and bladder in increments of 5% (ii) we changed the volume of rectum and bladder in increments of 5% and (iii) we kept the segmented volumes constant but changed their location by moving their COM in increments of 3mm. Using the Velocity software, we evaluated the accuracy of the DRA for each incremental change in all three scenarios. Results: The DRA performs reasonably well when the differential density difference against the background is more than 5%. For the volume change study, the DRA results became unreliable for relative volume changes greater than 10%. Finally for the location study, the DRA performance was acceptable for shifts below 9mm. Conclusion: Site specific and patient specific QA for DRA is an important step to evaluate such algorithms prior to their use for dose propagation.

60 APPLIED LIFE SCIENCES↗

DEVELOPMENT AND TESTING OF FAULT-DIAGNOSIS ALGORITHMS FOR REACTOR PLANT SYSTEMS

Argonne National Laboratory is further developing fault diagnosis algorithms for use by the operator of a nuclear plant to aid in improved monitoring of overall plant condition and performance. The objective is better management of plant upsets through more timely, informed decisions on control actions with the ultimate goal of improved plant safety, production, and cost management. Integration of these algorithms with visual aids for operators is taking place through a collaboration under the concept of an operator advisory system. This is a software entity whose purpose is to manage and distill the enormous amount of information an operator must process to understand the plant state, particularly in off-normal situations, and how the state trajectory will unfold in time. The fault diagnosis algorithms were exhaustively tested using computer simulations of twenty different faults introduced into the chemical and volume control system (CVCS) of a pressurized water reactor (PWR). The algorithms are unique in that each new application to a facility requires providing only the piping and instrumentation diagram (PID) and no other plant-specific information; a subject-matter expert is not needed to install and maintain each instance of an application. The testing approach followed accepted procedures for verifying and validating software. It was shown that the code satisfies its functional requirement which is to accept sensor information, identify process variable trends based on this sensor information, and then to return an accurate diagnosis based on chains of rules related to these trends. The validation and verification exercise made use of GPASS, a one-dimensional systems code, for simulating CVCS operation. Plant components were failed and the code generated the resulting plant response. Parametric studies with respect to the severity of the fault, the richness of the plant sensor set, and the accuracy of sensors were performed as part of the validation exercise. The background and overview of the software will be presented to give an overview of the approach. Following, the verification and validation effort using the GPASS code for simulation of plant transients including a sensitivity study on important parameters will be presented

Fault Diagnosis Algorithm↗

Design and Operability of a Pressurized Oxy Combustion System

Fossil fuel powers more than two-thirds of the world’s electricity, a significant share of which is derived from coal power plants. Despite coal being an abundant and energy-rich fuel, the major halt to its progress is greenhouse gas emissions. Pressurized oxy-combustion cycles can achieve theoretically high thermal efficiencies along with a 90% carbon capture rate. Additionally, the high energy density allows smaller turbomachinery and save capital cost. Thus, the primary objective of this dissertation is to present the design and operability of a pressurized oxy-combustor system. The initial part of the dissertation investigates different thermodynamic cycles and presents a model that can be adapted for existing power plants. The thermodynamic model will be used in the later part to design the proposed combustor. The two cycles analyzed are ENEL and TIPS. This study focuses on qualitative analyses of the cycles using a commercially available software called Aspen Plus®. A detailed benchmark study has been performed to validate the modeling process. ENEL and TIPS cycles are designed in the software, adopting the same principles. Recirculation ratio and pressures are varied to find the efficiency range of the cycles. Power calculations are done to find overall and net efficiency for a fixed recirculation ratio. The efficiencies of the cycles are compared to select an optimum cycle. A recirculation ratio of 50% is selected for implementation. The comparison shows that ENEL is marginally efficient over TIPS, at the cost of a pressure difference of about 70bars. Technology Readiness Level analysis is performed to present the availability of the specialized equipment for the cycles. From the TRL analysis, it is seen that the cost and availability of high viii pressure equipment surmount the edge of TIPS over ENEL. Thus, ENEL is chosen as the better cycle for investigating a scaled experiment considering efficiency and viability. The later part of the dissertation focuses on developing the combustor's design for a pressurized oxy-combustion cycle. The proposed combustor is a powerhead-mounted design aimed to produce 1MW of thermal outputThe different aspects of the design of a down-fired pressurized swirl combustor are presented in this dissertation.

Chowdhury, Mehrin↗

A Verification and Validation Approach for COMSOL Multiphysics to Support High Flux Isotope Reactor (HFIR)

Over the last several decades, many reactors have successfully been converted from high enriched uranium (HEU) to low enriched uranium (LEU) fuels in United States in support of its global non-proliferation objectives. Of the reactors slated for conversion, five high-performance research reactors (HPRRs) remain. The high-flux isotope reactor (HFIR) at Oak Ridge National Laboratory (ORNL) is one of the five. Conversion of HFIR requires the qualification of a new fuel. To aid in the conversion process as well as improve safety margins, COMSOL Multiphysics was chosen to support and eventually supplement the steady-state heat-transfer code (SSHTC). In order to use COMSOL as a supplementary tool, i.e. one used for safety basis calculations, the code needs to undergo a verification and validation process. Verification and validation are important processes for the use of any software; however, physics-based solvers have a unique challenge, in that the validation is much more rigorous and its domain is only applicable to the general scope of the problem. This document details the verification and validation of COMOSL for analysis of HFIR. This report is intended for two different users: (1) current and future users of COMSOL for HFIR and (2) for individuals interested in assessing the scope of the validation of COMSOL for HFIR. This report is divided into six sections. The first of which details the process of verification and validation. Section one provides an overview of key concepts from ASME V&V 10, 20, and 40 and how these concepts are used to provide a validation of any multiphysics software. Section two covers the approach needed in order to validate multiphysics software for a given HFIR analysis. Parts three through five split up the key concepts highlighted in section two. The final section provides concluding remarks which demonstrate the scope and limitations of the validation study and how these may be expanded and improved.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

54 ENVIRONMENTAL SCIENCES↗

Aquifer Injection Modeling (AIM) Toolbox User Guide

The Aquifer Injection Modeling Toolbox (“AIM Toolbox”) software was developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Environmental Protection Agency’s (EPA) to provide a collection of analytical solutions suitable for evaluating the potential extent of the area impacted by subsurface injection operations. Subsurface injection operations are regulated under the EPA’s Underground Injection Control (UIC) program and are typically related to oil/gas development, waste disposal, or subsurface mining or storage. The analytical algorithms provided in the AIM Toolbox each have different approaches/assumptions/focus with respect to the nature and processes in subsurface and the nature of the injection operations. Collectively the set of analysis algorithms provides a broader evaluation of the area that can potentially be impacted by an injection operation. By providing estimates for the injectate plume extent, the software supports technical aspects of planning, evaluation, and overseeing injection activities. That is, the results help assess when further regulatory controls (e.g., monitoring, reporting) may be required and, in the case of disposal into an underground source of drinking water, the extent of the impacted area would require exemption from protection under the Safe Drinking Water Act. The AIM Toolbox software is available as a single-page web application, providing an interface to provide the necessary inputs, and both chart and map panes for visualizing the results. This User Guide describes the AIM Toolbox software, information required, user interactions, and the underlying basis of the calculations.

58 GEOSCIENCES↗

Search for a charged Higgs boson in pp collisions at √s = 8 TeV

Our search for a charged Higgs boson is performed with a data sample corresponding to an integrated luminosity of 19.7 ± 0.5 fb -1 collected with the CMS detector in proton-proton collisions at √s=8,TeV. The charged Higgs boson is searched for in top quark decays for m H± < m t - m b, and in the direct production pp → t(b)H ± for m H± > m t - m b. The H ± → τ ± ν τ and H ± → tb decay modes in the final states τ h +jets, μτ h , ℓ+jets, and ℓℓ’ (ℓ =e, μ) are considered in the search. No signal is observed and 95% confidence level upper limits are set on the charged Higgs boson production. Furthermore, a model-independent upper limit on the product branching fraction B(t→H±b)B(H±→τ±ντ)=1.2-0.15% is obtained in the mass range m H± = 80–160 GeV, while the upper limit on the cross section times branching fraction σ(pp→t(b)H±)B(H ± → τ ± ν τ )=0.38-0.025 pb is set in the mass range m H+ = 180–600 GeV. Here, σ(pp → t(b)H±) stands for the cross section sum σ(pp→t¯(b)H+)+σ(pp→t(b¯)H-). Assuming B(H ± →tb)=1, an upper limit on σ(pp → t(b)H±) of 2.0–0.13 pb is set for m H± = 180–600 GeV. The combination of all considered decay modes and final states is used to set exclusion limits in the m H ± -tan β parameter space in different MSSM benchmark scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗