Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Precise Linker Length and Dynamic Bond Exchange Control Penetrant Diffusion in Dense Vitrimers

Polymer networks with dynamic covalent bonds have been investigated for their self-healing ability, recyclability, and potential as more sustainable materials. Recent results have indicated that in some cases, bond exchange can enhance the transport of penetrants in dense networks, pointing to their potential for separations of membranes. Here, imine dynamic bonds in ethylene oxide (EO) networks with precise linker lengths were synthesized to investigate the transport of N,N′-bis(2,5-di-tert-butylphenyl)-3,4,9,10-perylenedicarboximide (BTBP), a large, anisotropic dye molecule. Networks with mesh sizes smaller than, comparable to, and greater than the size of the penetrant axes were investigated to probe the effects of bond exchange and network confinement on transport. Mesh sizes, which ranged from 0.5 to 1.62 nm, were determined from shear rheology, glass transitions by calorimetry, and probe diffusion coefficients by fluorescence recovery after photobleaching. Permanent networks with identical EO chain lengths were prepared as control samples, and up to a 3 orders of magnitude increase in diffusion coefficient is observed in the dynamic systems for short linkers containing 13 backbone atoms. The longest linkers with 71 backbone atoms show no difference between the permanent and dynamic networks. Linkers shorter than 11 backbone atoms, corresponding to a mesh size smaller than the penetrant small axis, diffusion is no longer observable on the experimental time scale, indicating a sharp cutoff attributed to the precise linkers and narrow mesh size distribution. The dynamic imine exchange time scales were compared to the diffusive hopping times of penetrants and indicate that exchange can occur during a diffusive displacement. Furthermore, these findings provide insights into the factors affecting penetrant transport in dense polymers and inspire the development of next-generation selective polymer membranes.

Diffusion↗

Evolution of the ATLAS analysis model for Run-3 and prospects for HL-LHC

With an increased dataset obtained during the Run-2 of the LHC at CERN, the even larger forthcoming Run-3 data and the expected increase of the dataset by more than one order of magnitude for the HL-LHC, the AT-LAS experiment is reaching the limits of the current data production model in terms of disk storage resources. The anticipated availability of an improved fast simulation will enable ATLAS to produce significantly larger Monte Carlo samples with the available CPU, which will then be limited by insufficient disk resources. The ATLAS Analysis Model Study Group for Run-3 was setup at the end of Run-2. Its tasks have been to analyse the efficiency and suitability of the current analysis model and to propose significant improvements. The group has considered options allowing ATLAS to save, for the same sample of data and simulated events, at least 30% disk space overall, and has given recommendations on how significantly larger savings could be realised for the HL-LHC. Furthermore, suggestions were made to harmonise the current stage of analysis across the collaboration. The group has now completed its work: key recommendations will be the new small sized analysis formats DAOD_PHYS and DAOD_PHYSLITE and the increased usage of a tape carousel mode in the centralised production of these formats. This proceeding reviews the recommended ATLAS analysis model for Run-3 and the status of its implementation. It also provides an outlook to the HL-LHC analysis.

97 MATHEMATICS AND COMPUTING↗

Quantification of the sensitivity range in neutron dark-field imaging

In neutron grating interferometry, the dark-field image visualizes the scattering properties of samples in the small-angle and ultra-small-angle scattering range. These angles correspond to correlation lengths from several hundred nanometers up to several tens of micrometers. In this article, we present an experimental study that demonstrates the potential of quantitative neutron dark-field imaging. The dark-field signal for scattering from different particle sizes and concentrations of mono-dispersive polystyrene particles in aqueous solution is compared to theoretical predictions and the good agreement between measurements and calculations underlines the quantitative nature of the measured values and reliability of the technique with neutrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structural studies of metastable and equilibrium vortex lattice domains in MgB 2

Abstract The vortex lattice (VL) in MgB 2 is characterized by the presence of long-lived metastable states (MSs), which arise from cooling or heating across the equilibrium phase boundaries. A return to the equilibrium configuration can be achieved by inducing vortex motion. Here we report on small-angle neutron scattering studies of MgB 2 , focusing on the structural properties of the VL as it is gradually driven from metastable to equilibrium states (ESs) by an AC magnetic field. Measurements were performed using initial MSs obtained either by cooling or heating across the equilibrium phase transition. In all cases, the longitudinal correlation length remains constant and comparable to the sample thickness. Correspondingly, the VL may be considered as a system of straight rods, where the formation and growth of ES domains only occurs in the two-dimensional plane perpendicular to the applied field direction. Spatially resolved raster scans of the sample were performed with apertures as small as 80 μ m, corresponding to only 1.2 × 10 6 vortices for an applied field of 0.5 T. These revealed spatial variations in the metastable and equilibrium VL populations, but individual domains were not directly resolved. A statistical analysis of the data indicates an upper limit on the average domain size of approximately 50 μ m.

Louden, E. R.↗

Evaluation of the Radioactive Material Released in the Harborview Research and Training Building and Some Implications for Emergency Response

On 2 May 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a mobile hot cell on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%, was released from the mobile hot cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy’s Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. Furthermore, the implications for emergency response are relevant to data quality and management. A Data Quality Objective guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and archiving of samples.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Evaluation of the Radioactive Material Release in the Harborview Research and Training Building and Implications for Emergency Response

On May 2, 2019, during the 137 Cs source recovery operation, a source capsule in a research irradiator containing approximately 77.1 TBq was breached. Based on a geometric reconstruction analysis of the damage to the capsule, approximately 46.3 GBq (0.04%) was impacted by the chop saw (grinder) inside a Mobile Hot Cell (MHC) on the loading dock at the University of Washington Harborview Research and Training (HRT) Building. A very small fraction of the material impacted, less than 1%) was released from the Mobile Hot Cell and then to the rest of the HRT Building. The objectives of this project were to assess the accidental release of 137 CsCl and its implications related to emergency response methods and the ramifications of 137 CsCl transport. The phenomenology of this event was also compared with past alkali halide dispersal events. The vast number of measurements and samples collected by the remediation contractors, the Department of Energy's Nuclear Emergency Support Team, and the small number of retrospective samples collected by the authors informed the analysis. The techniques included (1) autoradiography and electron microscopy of samples collected from the HRT Building and the irradiator, (2) 3D visualization of deposition on surfaces and within the ventilation system, and (3) a study of the damage to the source capsule to evaluate the Cs particle size and particle composition due to the grinding accident. Subsequently, the cesium contaminant transport through the numerous pathways in the building was reconstructed to assess the deposition on surfaces as a function of particle size. The implications for emergency response are relevant to data quality and management. A Data Quality Objective (DQO) guides data collection methods so that they have appropriate accuracy and precision for the intended application. Recommendations were made with respect to the sample collection protocols and sample archival.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sampling Microbial Dynamics in the Salish Sea Estuary: Evaluating Methods to Capture Cyanobacteria and Cyanophage

Introduction: Picocyanobacteria from the genera Prochlorococcus and Synechococcus thrive across the globe in aquatic environments, have relatively small genomes, and have growth dynamics regulated by both viral interactions and abiotic conditions, making them excellent model organisms for exploring host-pathogencoevolution. Methods: We developed and refined methods to sample and sequence cyanobacteria, cyanophages, and measured features of their abiotic environment. Results: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons. Our preferred final protocol from this exploratory effort included a combination of in-line and single vacuum flask filtrations, which reduced filtration processing time by over threefold in some cases compared to other tested methods, such as a fully in-line sequence or in-site filtrations. We successfully extracted an average of approximately 400–1200 ng for all filter fractions, with some variations between kits. Discussion: The protocol described herein can successfully discriminate large-cell eukaryotic organisms, but size fractionation of picocyanobacteria appears to be affected by the presence of free DNA, multicellular structures, and abundant tycheposons.

Salish Sea↗

Fine-scale motion in NGC 6514 and NGC 6523

Velocity maps of the inner regions of the bright H II regions NGC 6514 and NGC 6523 were made with unprecedented spatial and spectral resolution in the 5007 A line of forbidden O III. In addition to the advantages of an instrumental full width at half-maximum intensity of only 5.4 km/s, the small thermal width of the heavy oxygen ion also allows determination of accurate line widths and velocities. The CCD spectra were numerically fitted to Gaussian line profiles and revealed two separate velocity systems in NGC 6523. The data sets of radial velocities were used to derive the dependence of the most probable turbulent velocities upon the sample sizes, and the spatial dependence of the structure function. These relationships are the basic functions for comparison with the predictions of the models for turbulence in H II regions.

O'Dell, C. R.↗

Spectral imaging of the Orion Bar at 3.3, 8.4, and 11.3 microns: Comparison with a fluorescent polycyclic aromatic hydrocarbon model

Spectral images were obtained of the Orion Bar which sample polycyclic aromatic hydrocarbon (PAH) emission at 3.3, 8.4, and 11.3 micrometers. The images are strikingly different even though they all sample PAH emission. In particular, the 3.3 and 11.3 micrometers images sample PAH emission from C-H bonds, yet the 3.3 micrometers image contains many small bright knots while the 11.3 micrometers image is much more uniform. For comparison with a fluorescent PAH model, a data set was created from the measured intensities of 250 locations in each image. From the comparison, we conclude that: (1) the size distribution of PAHs varies within the Bar, with the bright 3.3 micrometers knots containing the largest proportion of small PAHs; (2) the points along the front of the Bar have emission cross sections characteristic of neutral PAHs while within the Bar, the emission cross sections are different, consistent with the PAHs being charged; (3) the PAHs along the front of the Bar are larger than average for the Bar; (4) emission along the back of the Bar is consistent with PAH emission in an attenuated UV radiation field; (5) there is no evidence for PAH dehydrogenation.

Bregman, Jesse↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (theta about 450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NO(sub y)) had also been removed, with layers of enhanced (sub y) at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (about 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 micron) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range of theta is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (0-450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NO(y)) had also been removed, with layers of enhanced NO(y) at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approximately 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 microns) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range of 0 is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (theta approximately 450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NO(y)) had also been removed, with layers of enhanced NO(y) at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approximately 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 micrometers) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range Transport of theta is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Dehydration and Denitrification in the Arctic Polar Vortex During the 1995-1996 Winter

Dehydration of more than 0.5 ppmv water was observed between 18 and 19 km (theta = 450-465 K) at the edge of the Arctic polar vortex on February 1, 1996. More than half the reactive nitrogen (NOy) had also been removed, with layers of enhanced NOy at lower altitudes. Back trajectory calculations show that air parcels sampled inside the vortex had experienced temperatures as low as 188 K within the previous 12 days, consistent with a small amount of dehydration. The depth of the dehydrated layer (approx. 1 km) and the fact that trajectories passed through the region of ice saturation in one day imply selective growth of a small fraction of particles to sizes large enough (>10 micrometers) to be irreversibly removed on this timescale. Over 25% of the Arctic vortex in a 20-30 K range of theta is estimated to have been dehydrated in this event.

Hintsa, E. J.↗

Blood Collection

The method that is used for the collection, storage and real-time analysis of blood and other bodily fluids has been licensed to DBCD, Inc. by NASA. The result of this patent licensing agreement has been the development of a commercial product that can provide serum or plasma from whole blood volumes of 20 microliters to 4 milliliters. The device has a fibrous filter with a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein. The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber. The method used by this product is useful to NASA for blood analysis on manned space missions.

Source record↗

ELM: Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and bright-field microscope designed to meet key objectives defined in the 2016 NASA Europa Lander Study Report, including the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In situ Research imager, designed and built at NASA Ames Research Center, for the autonomous study of microbial biology in low Earth orbit. For ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line 10, 1.0, and 0.2 μm pore-size filters to capture successively smaller particles for imaging. For bright-field imaging, ELM uses deep-ultraviolet, ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect biosignatures as small as 0.2 μm in size is achieved by imaging native fluorescence and using fluorescence microscopy stains to identify key structural and functional indicators of microbial life (proteins, lipids, nucleic acids). For fluorescence imaging, ELM uses 265, 370, 470, and 530 nm LEDs with five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging enables the detection of a wide range of molecular species and their rough classification. Excitation at 265 nm allows for the detection of smaller polycyclic aromatic hydrocarbons (PAH), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and separated from organic fluorescence, allowing the recognition and in some cases classification, of minerals and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Richard C Quinn↗

Assessment of the Mars Helicopter Thermal Design Sensitivities Using the Veritrek Software

The Mars Helicopter will be a technology demonstration conducted during the Mars 2020 mission. The primary mission objective is to achieve several 90-second flights and capture visible light images via forward and nadir mounted cameras. These flights could possibly provide reconnaissance data for sampling site selection for other Mars surface missions. The helicopter is powered by a solar array, which stores energy in secondary batteries for flight operations, imaging, communications, and survival heating. The helicopter thermal design is driven by minimizing survival heater energy while maintaining compliance with allowable flight temperatures in a variable thermal environment. Due to the small size of the helicopter and its complex geometries, along with the fact that it operates with very low power and small margins, additional care had to be paid while planning thermal tests and designing the thermal system. A Thermal Desktop® model has been developed to predict the thermal system’s performance. A reduced-order model (ROM) created with the Veritrek software has been utilized to explore the sensitivities of the thermal system’s drivers, such as electronics dissipations, gas gaps, heat transfer coefficients, etc., as well as to assess and verify the final thermal design. This paper presents the performance of the Veritrek software products and the details of the ROM creation process. The results produced by Veritrek were utilized to study the effect of the major thermal design drivers and Mars environment on the Mars Helicopter in as little as 10 days, an effort that would have taken over 4 months using traditional thermal analysis techniques.

Hengeveld, Derek W.↗

Microscopic Object Classification through Passive Motion Observations with Holographic Microscopy

Digital holographic microscopy provides the ability to observe throughout a volume that is large compared to its resolution element without the need to refocus through the volume. This capability enables simultaneous observations of large numbers of small objects within such a volume. We have constructed a microscope that can observe a volume 0.4 x 0.4 x 1.0 µm with submicrometer resolution for observation of microorganisms and minerals in liquid environments in earth and on potential planetary missions. Because environmental samples are likely to contain mixtures of inorganics and microorganisms that are of comparable sizes near the resolution limit of the instrument, discrimination of living and non-living objects may be difficult. The motion of motile organisms can be used to readily distinguish them from non-motile objects (live or inorganic), but additional methods are required to distinguish non-motile organisms and inorganic objects that are of comparable size, but different composition and structure. In this paper we evaluate the use of passive motion to make this discrimination by evaluating diffusion and buoyancy characteristics of objects in the field of view.

Lindensmith, Christian↗

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗