Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “situation awareness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Distributed, Intelligent Edge-Sensing for a Smarter Grid

The electric grid is undergoing major transformations and developments resulting in unprecedented levels of volatility, uncertainty, and stress on grid infrastructure. Smart sensors and methods aiding in advanced visibility and situational awareness are key for tackling these issues. In this work, a decentralized architecture is proposed, where sensing, local computation and control capability are embedded in the edge devices, communicating with a set of trusted 'data mules' in a 'delay-tolerant' manner, while functioning autonomously. This system has been designed and implemented as an overall platform – called Global Asset Monitoring, Management and Analytics (GAMMA) Platform intended to provide the backbone for a global array of sensors and actuators. Further, as a building block for advanced current sensing solutions, a smart, low-cost ‘clip-on’ current sensor based on PCB-embedded Rogowski coil has been developed. The sensor hosts a novel signal conditioning stage allowing an 'auto-tuning' feature, resulting in a universal current sensor design for measuring a wide range of currents, including faults for smart grid applications. Finally, the research proposes a method to instrument and monitor key parameters for the most common electric utility asset – the pole-top distribution transformer. The work done in this research enables scalable, edge-intelligent sensing solutions for monitoring grid infrastructure, allowing utility operators to gain advanced visibility in an economical way.

Kulkarni, Shreyas Bhalchandra↗

Data Mining and Machine Learning for Power System Monitoring, Understanding, and Impact Evaluation

This chapter presents results from the Big Data analysis framework to improve power system situational awareness and system reliability. For this purpose, a dataset with real-world phasor measurement unit data and historical transmission system outage data has been created and used to carry out the analysis. Several statistical analysis and machine learning methods have been developed and implemented for event and anomaly detection and modeling. Detection and analysis results for actual examples of power system events are presented. Finally, data-driven characterization and risk assessment methods for weather-related extremes in power systems are developed and demonstrated on the Bonneville Power Administration system. These applications demonstrate the capability of Machine Learning (ML) methods to monitor system abnormalities, to predict system events, and to characterize the impact of extreme events on power grid

data mining, power grid, machine learning, anomaly↗

Online Tracking of Two Dominant Inter-Area Modes of Oscillation in the Eastern Interconnection

Reliable power system operation requires that small-signal stability be maintained at all times. Mode meters are measurement-based tools that provide operators with situational awareness of the system's stability margin. They operate by continually tracking the inter-area modes of oscillation that govern small-signal stability. This paper reports on the deployment of mode meters for online monitoring of two dominant modes of oscillation in the United States' Eastern Interconnection (EI). The use of measurements from system operators across the interconnection to provide continuous tracking is novel in the EI. Results from over four months of analysis reveal diurnal patterns in the modes and demonstrate that they can be tracked through a variety of system conditions. The results from this study continue to build an understanding of the EI's modes that will inform future modeling and monitoring efforts.

Follum, James D.↗

An Experimental Investigation of Students? Learning Effects When Using a Simplified Nuclear Simulator

This study focuses on investigating students' learning effects and performance trends over a certain period using the Rancor Microworld Simulator. Specifically, it aims to determine the training required to collect HRA data from non-experts (i.e., students) using Rancor Microworld and the differences in human performance measures between students and professional operators. A longitudinal experiment is conducted with sixteen undergraduate students, using four Rancor Microworld scenarios in each of the four experiment trials. The study considers four human performance measurements workload, situation awareness, time, and error. Finally, the trend of students' performance is compared with operator data collected from the previous experiment. Overall, this research complements previous studies by providing insights into how much training is required to collect HRA data from non-experts and the differences in human performance measures between students and professional operators.

99 GENERAL AND MISCELLANEOUS↗

An Experimental Investigation of Students’ Learning Effects When Using a Simplified Nuclear Simulator

Securing enough data has been a main challenge in human reliability analysis (HRA). Many researchers and institutes have made a lot of efforts for collecting HRA data to produce reasonable human error probabilities (HEPs) as well as reduce the uncertainty of HRA quantification. Representatively, U.S. Nuclear Regulatory Commission (U.S. NRC), Korea Atomic Energy Research Institute (KAERI) and Idaho National Laboratory (INL) have led lots of empirical research regarding the HRA data collection. The U.S. NRC and KAERI have mainly carried out full-scope simulator research collecting HRA data through experiments using full-scope simulators with actual operators. In contrast, INL has experimentally collected the data using simplified simulators and student operators. INL has proposed the Simplified Human Error Experimental Program (SHEEP) framework to complement full-scope data collection efforts by suggesting a way to infer full-scope data based on experimental data collected from students operating simplified simulators, specifically the Rancor Microworld Simulator (Rancor) and the Compact Nuclear Simulator (CNS). The aim of the SHEEP framework is to lower the entry point for collecting useful HRA data by securing large sample sizes at a reasonable amount of cost and labor while also guaranteeing a high degree of freedom when designing experiments. The authors’ previous research investigated whether data collected from the SHEEP framework could support a representative full-scope study. Besides, human performance differences between professional and student operators when using Rancor and CNS have been analyzed to understand the lack of fidelity of the simplified simulators and student operators within the SHEEP study. As a follow up research, this study experimentally investigates students’ learning effects and the performance trends over a certain period when using Rancor. This study aims to find out 1) how much training or education is required to collect HRA data from non-experts (i.e., students) when using Rancor and 2) how much differences there are in human performance measures between students and professional operators. In this study, a longitudinal experiment is developed. The four experiment trials with two weeks interval are carried out for sixteen undergraduate students majoring nuclear engineering at Chosun University. Totally four scenarios randomly selected from ten Rancor scenarios are used in each experiment trial. Four human performance measurements (i.e., workload, situation awareness, time and error) are considered in the experiment. Lastly, the trend of students’ performance is compared with operator data having been collected from the previous experiment.

99 GENERAL AND MISCELLANEOUS↗

Comparison of Human Performance between Operators and Students Using Rancor Microworld Simulator: A Preliminary Result

This paper describes an experiment using the Rancor Microworld simulator to probe into differences in human performance between students and actual operators. Six human performance measures – 1) time, 2) error, 3) workload, 4) situational awareness, 5) attention patterns, and 6) number of manipulations – are measured from experiments. The experiment has been conducted for 11 operators and 20 students so far. More experiments and analyses will be continued. Further experimental studies using Rancor Microworld are expected to be able to collect additional data that may be missing from full-scope studies and contribute to items that can support human reliability data.

99 GENERAL AND MISCELLANEOUS↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced dynamic contingency analysis for power systems

The present disclosure describes systems and techniques that enhance effectiveness and efficiency of a contingency analysis tool that is used for studying the magnitude and likelihood of extreme contingencies and potential cascading events across a power system. The described systems and techniques include deploying the contingency analysis tool in a high-performance computing (HPC) environment and incorporating visual situational awareness approaches to allow power system engineers to quickly and efficiently evaluate multiple power system simulation models. Furthermore, the described systems and techniques include the power system contingency-analysis tool calculating and coordinating protection element settings, as well as assessing controls of the power system using small-signal nomograms, allowing power system engineers to more effectively comprehend, evaluate, and analyze causes and effects of cascading events against a topology of a power system.

Samaan, Nader A.↗

From Count Rates to Quantifying Isotopic Activities – Field Analysis of Radiation Monitoring Data

The Nevada National Security Site (NNSS) provides a comprehensive bicoastal radiological and nuclear emergency response to United States Department of Energy/National Nuclear Security Administration. A major part of the support is to provide systematic radiological search for lost or stolen sources, Radiological search is a core competency of the NNSS with its origin dating back to nuclear weapons test era. Search operations from multiple platforms is the common thread among the various NNSS assets, which include Aerial Measuring System (AMS), Maritime Support Team (MST), National Capitol Response (NCR), National Search Team (NST) and Radiological Assistance Program (RAP). Information collected and analyzed during search operations add to the actionable intelligence for the law enforcement agencies and provide valuable guidance for the tactical resolution of a nuclear or radiological crisis. Search is an intelligence and situational awareness driven operation and most often called upon during a radiological emergency, however it can be brought into play to thwart a potential threat by providing monitoring and surveillance support. The Office of Nuclear Incident Response (NA-84) serves as the technical leader in responding to and resolving nuclear and radiological threats worldwide and integrates its efforts with other NNSA stakeholders (e.g., NNSA office of Defense Nuclear Non-proliferation NA-22). The response includes expertise in the areas of radiological search, render safe, and consequence management. This article will discuss the methodologies, tools, procedures, and techniques to extract maximum radiological characterization information (isotopic composition, activities for individual isotopes, threat assessment etc.) from field monitoring or Search operation data.

61 RADIATION PROTECTION AND DOSIMETRY↗

AI-ENABLED MONITORING OPTIONS TOWARDS SECURE MICROREACTOR DEPLOYMENT AND OPERATIONS

Global nuclear energy deployment scenarios suggest favorable economics for smaller, more versatile, and self-contained reactor technologies. Recognizing their key features as integrated, autonomous and either semi-remotely operated or fully remotely operated systems, microreactors are expected to be deployed in large numbers servicing off/micro-grids, many in geographically remote locations. Integrated nature of these systems as well as ease of their transportation as complete units, simplified installation and relocation/decommissioning challenge traditional continuity-of-knowledge practices used for conventional light water reactors where refueling is done onsite at designated times only replacing portions of their cores and only after their full commissioning for operations including completion of their containment building with security and safeguards measures in place. This effort is exploring AI (artificial intelligence)-enabled monitoring options that would be design agnostic and would assure secure unit deployment and operations. The principle is to maintain situational awareness via real-time evaluations of simultaneous and remotely transmitted monitoring data capturing key safeguards attributes including such characteristics as temperature, radiation, vibrational signals (inter alia), and others. The key principle is to provide reliable and resilient security options while maintaining simplified and economical deployment. The paper will review feasible options for AI-enabled solutions for such evaluations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Anomaly Detection and Mitigation for Dynamic Frequency Regulation in Hydropower-Battery Systems: Preprint

Hydropower operators and energy storage providers are increasingly interested in participating in frequency regulation services, driven by the incentives offered by independent system operators, such as the Pennsylvania-New Jersey-Maryland Interconnection (PJM), in a competitive electricity market. This transition, however, unfolds against the backdrop of a modernizing and rapidly digitizing power grid, exposing the integrated legacy infrastructure and vulnerable communication networks to a multitude of cybersecurity threats. These evolving threats not only endanger grid operations but also have the potential to trigger cascading disruptions across the broader grid network and influence regulation markets. This work presents an approach for developing an anomaly detection and mitigation system to address cybersecurity challenges during the participation of a hydropower-integrated battery energy storage system (BESS) in a frequency regulation market. The applied anomaly detector utilizes machine learning algorithms to provide detailed classification of cyber-physical events and provide a comprehensive situation awareness to grid operators. Later, the applied mitigation system triggers predefined corrective actions to minimize the impact of data integrity attacks on the regulation market and system stability. We evaluated the proposed approach on a fully active BESS topology using the slow regulation signal (Reg A) coming from the PJM market. Our simulation results reveal that the proposed approach performs well in detecting data integrity attacks within the allocated time frame and also minimizes the system's instability and economic loss during the participation of hydropower and BESS in the regulation market.

battery energy storage system↗

A Real-Time ANPC Inverter Digital Twin with Integrated Design-For-Trust

The demand for renewable energy has increased over the last few years, and so has the demand for greater expectations within the energy market. This increasing trend has been accompanied by more significant usage of internet-connected devices (IoT), leading to critical electrical infrastructure being connected to the internet. Implementing internet connectivity with such devices and systems provides benefits such as improving the system's performance, facilitating irregularity and anomaly mitigation, and providing additional situational awareness for enhanced decision-making. However, enhancing the connected system with IoT introduces a drawback – a greater vulnerability to cyber-attacks. Cyber-attacks targeting critical infrastructure in the electrical sector have occurred in the United States and Ukraine. These cyber-attacks highlight and expose vulnerabilities that a system inherits when connecting to the internet. These attacks left thousands of customers without electricity for hours until operators could regain control of the electric utility grid. Therefore, to address the vulnerabilities of an internet-connected power electronic device, this work focused on the hardware layer of the system. Implementing a cyber-control system inside the hardware layer can significantly reduce the possibility of an attacker patching malicious controller firmware into a photovoltaic grid-connected inverter, thus mitigating the likelihood that the inverter becomes inactive a cyber-attack scenario. With this mitigation technique, if a cyberattack is successful and an attacker gains control of the network, a cyber-defense technique is in place to mitigate the impact of the cyber-attack. This additional protection layer was developed based on an innovative concept known as Digital Twin (DT). A DT, in this case, replicates an Active-Neutral Point Clamped (ANPC) inverter and was designed using a hardware language known as VHDL (Very High-Speed Integrated Circuit Hardware Description Language) and applied to Field-Programmable-GateArray (FPGA). The DT is embedded within the FPGA and contained in a controller board, the UCB (Unified Controller Board), developed by the University of Arkansas electrical engineering team. This UCB also contains two Digital Signal Processors (DSPs) responsible for generating associated signals to control an authentic physical inverter. These DSP signals are received and processed by the FPGA that implements the DT of an ANPC; in other words, it simulates in realtime the expected output of an actual ANPC inverter using the signals from the DSP. When a new firmware is ready to be patched, the DT provides output signals simulating behavior that a real ANPC inverter would generate with the new firmware. The new firmware is tested to check if it meets all the operational requirements established using a Design-For-Trust technique (DFTr). If the new firmware fails in at least one of the DFT tests, it is considered malicious and must be rejected. This work is divided into sections, such as Background, which explains the pieces that were used and the strategy behind this work; Process and Procedure, which explains the methodology that was adopted to prove the reliability and effectiveness of this work; Results and Discussion, where the simulations and results are described and explained; followed by Conclusion and Future work section, which concludes this work and adds possible future projects to continue this work further.

do Amaral Custodio, Paulo Vitor↗

Development of a Multi Sensor Data Science System for Monitoring a Solvent Extraction Process

Idaho National Laboratory is designing and constructing a solvent extraction test bed, Beartooth, as part of a nuclear fuel cycle stewardship initiative. The test bed will provide facilities and equipment for testing novel extraction processes and give early career scientists opportunities to gain skills in performing separations chemistry. The test bed is being uniquely designed to enable machine learning capabilities for the characterization of chemical process operations. One of the intentions of incorporating machine learning methods is to provide process operators with enhanced situational awareness for the optimization of separations techniques and possible detection of a diversion event. As a result, the objective of this Laboratory Directed Research and Development project is to develop a multi-sensor data collections system and implement machine learning techniques on signals from an existing centrifugal contactor cascade to identify equipment usage and process events. This presentation will provide an overview of sensors used and experiments conducted to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer-Based Procedures Among Older Adults: Findings from the Rancor Microworld Simulator

As with many industries worldwide, nuclear energy is experiencing an aging workforce; older than other energy sources and the national average. For example, while almost one in three nuclear industry professionals are 55+ years, for oil and gas that number is one in five. The challenges brought about by an aging workforce are one of the industry’s top concerns. However, the industry lacks for empirical research that examines the effects of developmental aging in older workers, as well as the interactions between aging and new digital technologies. We present the results of an experiment that tested three different computer-based procedures in a sample of 30 older adults (55+ years). While the industry has traditionally relied on paper-based procedures, these are being modernized by digital technology. Participants were randomly assigned to one of three procedure-types that varied by the level of digitalization, based on the IEEE Standard-1786. Type 1 essentially represents a digital representation of a paper-based procedure, Type 2 adds embedded indicators, and Type 3 adds soft controls. Participants performed two different operational scenarios (startup and loss of feedwater) on a simplified nuclear power plant simulator. Results revealed a weak signal that Type 2 may produce lower workload and lower completion times in some instances. However, there were no significant effects of procedure-type across any other outcomes, including simulator log data, situation awareness, and preference ratings. We discuss our findings in terms of optimal levels of digitalization/automation for an aging nuclear workforce and suggest pathways for future directions.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Power System Feature-Based Event Classification by Means of Multiple PMU Data

Abstract—Phasor Measurement Units (PMUs) provide time synchronized measurements across the power grid, enabling data driven event detection and classification for enhanced system monitoring and situational awareness. However, variations in event duration, spatial extent, and severity, along with coincident events, pose challenges for conventional classification models that require fixed-size inputs. This paper presents a feature-based framework that aggregates diverse attributes from all available PMUs for each event into a fixed-length vector, facilitating the application of standard machine learning classifiers, including Random Forest, XGBoost, and Multilayer Perceptron. A probabilistic post-processing scheme is further introduced to enable multi-label classification in the presence of overlapping events. Experiments using real-world PMU data demonstrate that the Random Forest model achieves 95% accuracy, while the proposed post-processing method yields an additional 3% improvement.

Nematirad, Reza↗

Analysis of Pilot Feedback Regarding the Use of State Awareness Technologies During Complex Situations

A flight simulation study was conducted at NASA Langley Research Center to evaluate flight deck systems that (1) predict aircraft energy state and/or autoflight configuration, (2) present the current state and expected future state of automated systems, and/or (3) show the state of flight-critical data systems in use by automated systems and primary flight instruments. Four new technology concepts were evaluated vis-à-vis current state-of-the-art flight deck systems and indicators. This human-in-the-loop study was conducted using commercial airline crews. Scenarios spanned a range of complex conditions and several emulated causal factors and complexity in recent accidents involving loss of state awareness by pilots (e.g. energy state, automation state, and/or system state). Data were collected via questionnaires administered after each flight, audio/video recordings, physiological data, head and eye tracking data, pilot control inputs, and researcher observations. This paper strictly focuses on findings derived from the questionnaire responses. It includes analysis of pilot subjective measures of complexity, decision making, workload, situation awareness, usability, and acceptability.

Evans, Emory↗

The effect of communications and traffic situation displays on pilots awareness of traffic in the terminal area

The Air Traffic Control (ATC) system is evolving under a general plan specified by the Federal Aviation Administration. Among the developments being considered is the Discrete Address Beacon System (DABS). The use of this system, although relieving congestion on the communications frequencies, would eliminate information about other aircraft because the party line communications now in use would be lost. One alternative to restore this lost information is an Airborne Traffic Situation Display (TSD). Experienced airline and military pilots participated in a factorial design to evaluate two types of communication (discrete address, party line) and two types of displays (TSD, no TSD). A stop-action quiz was used to evaluate their knowledge of other aircrafts' position, altitude, speed, heading, rate of climb, identity, and landing sequence number. Significant differences between conditions were detected, primarily in the position variables. Workload, as measured by a spare capacity side-task, showed a main effect of displays and a significant interaction between displays and communications. The data are summarized by plotting each display/communication condition configuration in the plane defined by information and workload index. A limited number of blunders by other aircraft were included in the simulations with a significant, but not entirely satisfactory, improvement in blunder detection attributed to the TSD.

Melanson, D.↗

Latest developments in cryogenic safety

The Cryogenic Safety Manual, sponsored by the British Cryogenics Council, was published over 10 years ago. A new updated version is now available. Some general aspects of cryogenic safety are highlighted, and attention is drawn to some of the more unusual hazardous situations. An awareness of the physical properties of the cryogenic fluids being dealt with is important in directing attention to hazardous situations which may arise. Because of this, the more important properties of the cryogenic fluids are given, such as molecular weight, boiling point and freezing point. From these properties, hazardous situations can be deduced. There are hidden dangers that are not always easy to spot. Some of the unexpected hazards, most of which have led to deaths, are: asphyxiation (anoxia), frost bites and hypothermia, explosions, and combustion. The aim of this publication is to help bring about increased safety in the production and use of cryogenic products through a deeper appreciation of the scientific, technological and administrative steps which must be made if accidents, some fatal, are to be voided in the future.

Webster, T. J.↗