Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Hard X-ray astrophysics

Past hard X-ray and lower energy satellite instruments are reviewed and it is shown that observation above 20 keV and up to hundreds of keV can provide much valuable information on the astrophysics of cosmic sources. To calculate possible sensitivities of future arrays, the efficiencies of a one-atmosphere inch gas counter (the HEAO-1 A-2 xenon filled HED3) and a 3 mm phoswich scintillator (the HEAO-1 A-4 Na1 LED1) were compared. Above 15 keV, the scintillator was more efficient. In a similar comparison, the sensitivity of germanium detectors did not differ much from that of the scintillators, except at high energies where the sensitivity would remain flat and not rise with loss of efficiency. Questions to be addressed concerning the physics of active galaxies and the diffuse radiation background, black holes, radio pulsars, X-ray pulsars, and galactic clusters are examined.

Rothschild, R. E.↗

Starprobe - Coronal plasma turbulence effects on tracking and telemetry

The telemetry and tracking problems expected for Starprobe, a solar flyby with a perihelion of 4 solar radii, are discussed. The Starprobe is intended to obtain measurements of the solar quadrupole moment within an accuracy of 1/100,000,000, allowing more accurate modelling of the solar interior. Obstacles are perceived for Doppler velocity measurements due to RF signal amplitude and phase scintillations created by the solar corona. Model calculations are presented for the propagation effects in the maximum disturbance area, and an open loop two-way Doppler system is described. The system comprises X-band and S-band uplinks and downlinks to eliminate the plasma-induced phase scintillations, means of correcting unfolding errors caused by S-band amplitude scintillations, and a new method of estimating the Doppler frequency.

Armstrong, J. W.↗

Small-scale turbulence in the atmosphere of Venus

Pioneer Venus data on the morphology of the 45 and 65 km altitude scintillation regions were analyzed. A poleward decrease in the 65 km scintillations was detected, together with a peak at 60-70 deg latitude. Poleward increases in refractive index fluctuations and temperature fluctuations from previous observations displayed a peak near 70 deg latitude, with greater turbulence near the pole. The same fluctuations were an order of magnitude lower at 45 km altitude, with turbulence considerably lower than at 60 km. The favorable comparison of the scintillation measurements with the in-situ velocity and temperature measurements validates the radio measurement technique as a probe of small scale turbulence in a planetary atmosphere. Particular success is noted in identification of small scale temperature fluctuations as a result of shear generated turbulence.

Woo, R.↗

Propagation effects on satellite systems at frequencies below 10 GHz, a handbook for satellite systems design, 1st edition

Satellite communications below about 6 GHz may need to contend with ionospheric effects, including Faraday rotation and ionospheric scintillation, which become increasingly significant with decreasing frequency. Scintillation is most serious in equatorial, auroral, and polar latitudes; even the 4 to 6 GHz frequency range turns out to be subject to scintillation to a significant degree of equatorial latitudes. Faraday rotation, excess range or time delay, phase advance, Doppler frequency fluctuations, and dispersion are proportional to total electron content (TEC) or its variation along the path. Tropospheric refraction and fading affects low angle satellite transmissions as well as terrestrial paths. Attenuation and depolarization due to rain become less important with decreasing frequency but need consideration for frequencies of about 4 GHz and higher. Empirically derived relations are useful for estimating the attenuation expected due to rain for particular percentages of time. Aeronautical, maritime, and land mobile satellite services are subject to fading due to multipath propagation.

Flock, W. L.↗

Magnetic field orientations in Saturn's upper ionosphere inferred from Voyager radio occultations

The radio scintillations observed during occultations of Voyagers 1 and 2 by Saturn are analyzed to determine the morphology of plasma irregularities and hence the magnetic field orientation in Saturn's upper atmosphere. The measurement techniques, the weak scattering theory, and the method used to relate the observed radio scintillations to physical properties of the ionospheric irregularities are briefly described. Results on the spatial characteristics of the irregularities are presented, and the magnetic field orientation in Saturn's ionosphere is inferred. Although the occultation measurements generally confirm the accuracy of the Saturnian magnetic field model of Connerney et al. (1982), it is found that a small adjustment of the coefficients in that model's zonal harmonic expansion would remove the discrepancy between the model predictions and the measurements. A strategy for obtaining improved measurements of Saturn's magnetic field from radio occultation observations of scintillations and Faraday rotation using an orbiting spacecraft is briefly discussed.

Hinson, D. P.↗

Ariel 6 measurements of ultra-heavy cosmic ray fluxes in the region 34 or = Z or = 48

The Ariel VI satellite was launched by NASA on a Scout rocket on 3rd June 1979 from Wallops Island, Virginia, USA, into a near circular 625 km orbit inclined at 55 deg. It carried a spherical cosmic ray detector designed by a group from Bristol University. A spherical aluminum vessel of diameter 75 cm contains a gas scintillation mixture and a thin spherical shell of Pilot 425 plastic, and forms a single optical cavity viewed by 16 photomultipliers. Particle tracks through the detector may be characterized by their impact parameter p and by whether or not they pass through the cup of plastic scintillator placed between the sphere and the spacecraft body (referred to below as the Anti-Coincidence Detector or ACD). Individual particle charges are determined by separately measuring the gas scintillation and the Cerenkov emission from the plastic shell. This is possible because of the quite different distribution in time of these emissions.

Fowler, P. H.↗

SONTRAC: A solar neutron track chamber detector

The recent detection on the solar maximum mission (SMM) satellite of high energy neutrons emitted during large solar flares has provided renewed incentive to design a neutron detector which has the sensitivity, energy resolution, and time resolution to measure the neutron time and energy spectra with sufficient precision to improve our understanding of the basic flare processes. Over the past two decades a variety of neutron detectors has been flown to measure the atmospheric neutron intensity above 10 MeV and to search for solar neutrons. The SONTRAC (Solar Neutron Track Chamber) detector, a new type of neutron detector which utilizes n-p scattering and has a sensitivity 1-3 orders of magnitude greater than previous instruments in the 20-200 MeV range is described. The energy resolution is 1% for neutron kinetic energy, T sub n 50 MeV. When used with a coded aperture mask at 50 m (as would be possible on the space station) an angular resolution of approx. 4 arc sec could be achieved, thereby locating the sites of high energy nuclear interactions with an angular precision comparable to the existing x-ray experiments on SMM. The scintillation chamber is investigated as a track chamber for high energy physics, either by using arrays of scintillating optical fibers or by optical imaging of particle trajectories in a block of scintillator.

Frye, G. M., Jr.↗

Application of photodiodes to the detection of electromagnetic bursts

A new type of photodiode + scintillator (1 m2 x 1 cm) detector is developed to detect the large electro-magnetic burst under an EX-chamber. The threshold burst size is found to be 4.3 x 10 the 5 particles at the center of the scintillator. Therefore a gamma-ray family of 10 TeV is detectable by it, when it is set under 14 r.1. of iron. In addition, a very fast (2.4 nsec width) and very bright (correspond to 10 to the 6 particles) scintillation pulse has become avarable for this study.

Fukushima, Y.↗

EGRET - The high energy gamma ray telescope for NASA's Gamma Ray Observatory

The EGRET high energy gamma-ray telescope under development for NASA's Gamma Ray Observatory will have an energy range of approximately 12 to 30,000 MeV, energy resolution of about 15 percent FWHM over most of that range, an effective area of about 2000 sq cm at high energies, and single photon angular accuracy of approximately 2 deg at 100 MeV, less than 0.1 deg above 5 GeV. This instrument can locate strong sources to an accuracy of about 5 arc min. The instrument utilizes a set of digital spark chambers interleaved with tantalum foils for detection and identification of gamma-ray events, and a large NaI(Tl) scintillator for energy determination. The system is triggered by a coincidence matrix using two arrays of plastic scintillation counters and a large plastic scintillator anticoincidence dome that rejects incident charged particles.

Fichtel, C. E.↗

1985 Nuclear Science Symposium, 32nd, and 1985 Symposium on Nuclear Power Systems, 17th, San Francisco, CA, October 23-25, 1985, Proceedings

The present conference ranges over topics in high energy physics instrumentation, detectors, nuclear medical applications, health physics and environmental monitoring, reactor instrumentation, nuclear spacecraft instrumentation, the 'Fastbus' data acquisition system, circuits and systems for nuclear research facilities, and the development status of nuclear power systems. Specific attention is given to CCD high precision detectors, a drift chamber preamplifier, a Cerenkov ring imaging detector, novel scintillation glasses and scintillating fibers, a modular multidrift vertex detector, radial wire drift chambers, liquid argon polarimeters, a multianode photomultiplier, the reliability of planar silicon detectors, the design and manufacture of wedge and strip anodes, ultrafast triode photodetectors, photomultiplier tubes, a barium fluoride plastic scintillator, a fine grained neutron hodoscope, the stability of low leakage silicon photodiodes for crystal calorimeters, and X-ray proportional counters. Also considered are positron emission tomography, single photon emission computed tomography, nuclear magnetic resonance imaging, Geiger-Muller detectors, nuclear plant safeguards, a 32-bit Fastbus computer, an advanced light water reactor, and nuclear plant maintenance.

Source record↗

Hard X-ray and low-energy gamma-ray spectrometers

Basic principles of operation and characteristics of scintillation and semi-conductor detectors used for solar hard X-ray and gamma-ray spectrometers are presented. Scintillation materials such as NaI offer high stopping power for incident gamma rays, modest energy resolution, and relatively simple operation. They are, to date, the most often used detector in solar gamma-ray spectroscopy. The scintillator BGO has higher stopping power than NaI, but poorer energy resolution. The primary advantage of semi-conductor materials such as Ge is their high-energy resolution. Monte-Carlo simulations of the response of NaI and Ge detectors to model solar flare inputs show the benefit of high resoluton for studying spectral lines. No semi-conductor material besides Ge is currently available with adequate combined size and purity to make general-use hard X-ray and gamma-ray detectors for solar studies.

Gehrels, N.↗

SIGHT - A balloon borne hard X-ray telescope

The authors report on progress toward developing a large-area, high-pressure xenon gas scintillator for use in hard X-ray astrophysics. Proof test results for a low-mass pressure vessel are presented. The design of a high-voltage multiplier board operating inside the scintillation chamber is discussed. The development of tetrakis-dimethylamine-thylene (TMAE)-based proportional tubes for detecting primary scintillation in the xenon is described. Finally, Monte Carlo tests of a scheme to use conventional photomultiplier tubes are discussed.

Wilkerson, J.↗

The UCSD high energy X-ray timing experiment cosmic ray particle anticoincidence detector

The HEXTE, part of the X-Ray Timing Explorer (XTE), is designed to make high sensitivity temporal and spectral measurements of X-rays with energies between 15 and 250 keV using NaI/CsI phoswich scintillation counters. To achieve the required sensitivity it is necessary to provide anticoincidence of charged cosmic ray particles incident upon the instrument, some of which interact to produce background X-rays. The proposed cosmic ray particle anticoincidence shield detector for HEXTE uses a novel design based on plastic scintillators and wavelength-shifter bars. It consists of five segments, each with a 7 mm thick plastic scintillator, roughly 50 cm x 50 cm in size, coupled to two wavelength-shifter bars viewed by 1/2 inch photomultiplier tubes. These segments are configured into a five-sided, box-like structure around the main detector system. Results of laboratory testing of a model segment, and calculations of the expected performance of the flight segments and particle anticoincidence detector system are presented to demonstrate that the above anticoincidence detector system satisfies its scientific requirements.

Hink, P. L.↗

X-ray spectroscopy with silicon pin and avalanche photo diodes

Results of an evaluation of silicon P-Intrinsic-N (PIN) photodiodes and Avalanche Photodiodes (APD) for the direct detection of soft x rays from 1 to 20 keV and for the detection of scintillation light output from CsI(TI) for higher x ray energies (30 to 1000 keV) are presented. About one keV resolution was achieved at room temperature for both the PIN and APD detectors for soft x rays (1 to 20 keV). Commercially available, low power (18 mV), low noise, hybrid preamplifiers, were used. These photodiodes were also coupled to CsI(TI) scintillator and obtained about 6 resolution at 662 keV. The photodiode frequency response matches well with the emission spectrum of the CsI(TI) scintillator providing good spectral resolution and a higher signal than NaI(TI) when viewed by conventional photomultipliers. A PIN-CsI(TI) combination provides a low energy threshold of around 60 keV while for the APD-CsI(TI) it is 15 keV.

Desai, U. D.↗

X-ray remote sensing and in-situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in-situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. A calibration facility is being constructed at Schlumberger-Doll Research for gamma and x ray detectors. With this facility the detector response can be determined in an invariant and reproducible fashion. Initial use of the facility is expected for the MARS94 detectors. Work is continuing to better understand the rare earth oxyorthosilicates and to define their characteristics. This will allow a better use of these scintillators for planetary missions. In a survey of scintillating materials two scintillators were identified as promising candidates besides GSO, LSO, and YSO. These are CdWO4 and CsI(Tl). It will be investigated if a detector with a better overall performance can be assembled with various photon converters. Considerable progress was achieved in photomultiplier design. The length of an 1 inch diameter PMT could be reduced from 4.2 to 2.5 inches without performance degradation. This technology is being employed in the gamma ray detector for the NEAR project. A further weight and size reduction of the detector package can be achieved with miniaturized integrated power supplies.

Mahdavi, M.↗

Radio interferometer observations of solar wind turbulence from the orbit of Helios to the solar corona

We report observations of Very Long Baseline Interferometer (VLBI) phase scintillations due to turbulence in the solar wind. The observations were made at 5.00 and 8.42 GHz with the Very Long Baseline Array (VLBA) on three dates in 1991 July and August. We observed the sources 0851 + 202 and 0735 + 178 at solar elongations ranging from 2.66 deg to 13.29 deg; the closest approach of the line of sight to the Sun ranged from 10 to 49.8 solar radii. We have also included previously unpublished 5 GHz VLBI phase scintillation measurements from 1989. These measurements probe solar wind density fluctuations on spatial scales from about 200 km to 2000 km. Our measurements are in quite good agreement with the Coles & Harmon model for the radio phase structure function, which was largely determined from observations on both shorter and larger spatial scales. Departures from the Coles & Harmon functions are attributable to day-to-day variations in the solar wind conditions. Phase scintillations at the greatest solar elongations are in very good agreement with extrapolated estimates from direct measurements made with the Helios spacecraft at slightly larger heliocentric distances. Thus there is a consistency between the in-situ spacecraft and radio sensing measurements of density turbulence. All of the VLBI data are consistent with a Kolmogorov spectrum for the density fluctuations, although at the closest elongations there may be excess power at small spatial scales. An advantage of interferometric techniques over other radio propagation measurements is that they provide a measure of the anisotropy of the irregularities. Our observations at closest approach (10 solar radii) show weak evidence for anisotropic, field-aligned density irregularities with an axial ratio of order 2. This degree of anisotropy would appear to be less than that measured at similar solar elongations but on smaller spatial scales by Armstrong and colleagues. Finally, a combination of the radio propagation data and in situ Helios measurements is used to determine the heliocentric distance dependence of the normalization coefficient of the density power spectrum, C(sup 2)(sub N). Modeling C(sup2)(sub N) varies as (R/solar radii)(sup -Kappa), we find Kappa = 3.72 +/- 0.30. Subject to a number of assumptions, this result is consistent with the conclusion of D. A. Roberts that turbulence within 0.28 astronomical units adheres to a WKB formula for turbulence amplitude as a function of heliocentric distance.

Spangler, Steven R.↗

Fine-Scale Filamentary Structure in Coronal Streamers

Doppler scintillation measurements of a coronal streamer lasting several solar rotations have been conducted by Ulysses in 1991 over a heliocentric distance range of 14-77 R(sub 0). By showing that the solar corona is filamentary, and that Doppler frequency is the radio counterpart of white-light eclipse pictures processed to enhance spatial gradients, it is demonstrated that Doppler scintillation measurements provide the high spatial resolution that has long eluded white-light coronagraph measurements. The region of enhanced scintillation, spanning an angular extent of 1.8 deg in heliographic longitude, coincides with the radially expanding streamer stalk and represents filamentary structure with scale sizes at least as small as 340 km (0.5 sec) when extrapolated to the Sun. Within the stalk of the streamer, the fine-scale structure corresponding to scale sizes in the range of 20-340 km at the Sun and associated with closed magnetic fields amounts to a few percent of the mean density, while outside the stalk, the fine-scale structure associated with open fields is an order of magnitude lower. Clustering of filamentary structure that takes place within the stalk of the streamer is suggestive of multiple current sheets. Comparison with ISEE 3 in situ plasma measurements shows that significant evolution resulting from dynamic interaction with increasing heliocentric distance takes place by the time streamers reach Earth orbit.

Woo, Richard↗

Data Acquisition and Prompt Analysis System for High Altitude Balloon Experiments

An inexpensive and simple data acquisition system has been developed for balloon borne experiments and has been tested with a gamma ray detector in a balloon flight launched from Palestine, Texas. The detector used for the test consisted of an NaI(T1) scintillation crystal encased in a 1/8 in. plastic scintillator-charged particle shield. The combination was viewed by a single photomultiplier and charged particle gating was accomplished by a conventional phoswich discriminator. The pulse height analysis of the NaI events, not associated with prompt charged particle interactions, is accomplished by converting to a time spectrum using an airborne height to time converter. A range of pulse widths from 5 microseconds to 250 microseconds corresponds to energy losses in NaI from 100 to 1000 keV. The time spectrum information, along with charged particle events and barometric pressure, is fed to a mixer which modulates a 252.4 Mc FM transmitter. The original scintillator spectrum is recovered on the ground utilizing conversion circuitry at the receiver video output and a 128 channel commercial pulse height analyzer. The charged particle events of standard time width are stored with the spectrum at a fixed channel position and are therefore represented by a sharp line riding on the lower part of the NaI energy loss spectrum. An energy loss greater than 1000 keV is presented by the maximum pulse width of the converter and stored in the last analyzer channel. Barometric pressure data is transmitted by low frequency modulation of the sme FM carrier. In flight operation, the receiver video output can be recorded on a wide band tape recorder and simultaneously analyzed by the 128 channel analyzer, or the telemetered data can be analyzed later. The flight system features high pulse resolution, essentially instantaneous time response, high data rate, and flexibility; and is of modest cost. A detailed description of the system and operating performance is discussed.

Sarkady, A. A.↗