At least 1,045 records · Page 58

Nanometer-Scale Carrier Imaging of Potential-Induced Degradation in c-Si Solar Cells

We report on nm-resolution imaging of chargecarrier distribution around local potential-induced degradation (PID) defects using scanning capacitance microscopy. We imaged cross sections of heavily field-degraded module areas as cored out and selected by mm-scale photoluminescence imaging. Localized areas with abnormal carrier behavior or junction damage were found: the apparent n-type carrier extends vertically into the absorber to ~1-2 um from the cell surface, and laterally in similar lengths; in defect-free areas, the n-type carrier extends ~0.5 um, which is consistent with the junction depth. For comparison, we also investigated areas of the same module exhibiting less PID stress, and did not find any such heavily damaged junction area. Instead, we found slightly abnormal carrier behavior, where the carrier-type inversion in the absorber did not occur, but the p-type carrier concentration changed slightly in a much smaller lateral length of ~300 nm. These nanoelectrical findings suggest that the existing extended defects, which may not be significantly harmful to cell performance, were changed by PID to heavily damaged junction areas.

14 SOLAR ENERGY↗

Workload and transmission data for the installation of a digital breast tomosynthesis system

Purpose: Digital breast tomosynthesis (DBT) differs from conventional mammography in target/filter, kVp range, and imaging geometry. The aim of this study was to assess the breast input exposure of a DBT system by completing a workload survey of DBT installations, and to determine the parameters {alpha}, {beta}, and {gamma} in the Archer equation for the primary radiation generated by the clinical workload distributions. Methods: The authors conducted a retrospective survey of the x-ray breast imaging performed between September 2011 and September 2012 in three clinical DBT rooms equipped with Selenia Dimensions systems (Hologic Inc., Bedford, MA). A total of 343 examinations were analyzed to calculate the workload (mA-minute) and the primary air kerma at 1 m from the source (K{sup 1}). Transmission curves were calculated for the primary radiation generated by the workload distributions of the DBT rooms, and were fitted to the Archer equation. Results: There were large variations in patient volume and workload in the three examination rooms. In all these rooms, the average tube voltage (kVp) was about 31, the average K{sup 1} per patient was 16-21 mGy, and the average mA-minute per patient was 1.4-2.2 times higher than that of the mammography room described in NCRP Report No. 147. Most DBT screening examinations consisted of four two-dimensional mammographic views plus four tomosynthesis scans; the numbers of views acquired in diagnostic examinations varied widely. Tomosynthesis scans contributed about 30% of total mA-minute and about 50% of K{sup 1}. For the primary radiation generated by the clinical workload distributions, {alpha} was similar to that of 40-45 kVp W/Al (target/filter), and {alpha}+{beta} was similar to that of 30 kVp W/Al. Conclusions: The workload (mA-minute and K{sup 1}) distributions of mammographic examinations with DBT differ from conventional mammography. A field survey of patient volume and x-ray tube usage is important for the shielding design of DBT facilities. The clinical workloads and transmission data presented in this paper may be useful for clinical medical physicists.

61 RADIATION PROTECTION AND DOSIMETRY↗

Examination of Intergranular Crack on SC0234

The microstructure of the SC0234 weld was evaluated per DA-SPEC-01067, ''General Purpose Heat Source (GPHS) Plutonium-238 Dioxide Fueled Clad Product Specification'' and it was determined that the weld microstructure conformed to the quality requirements. During the examination of weld cross section, the metallographic analysis revealed the presence of a surface crack. Prior visual examination per RPS-TA55-303 had not revealed the crack, nor did the surface photography performed per RPS-TA55-302. The presence of the crack does not violate any of the product specifications called out on DA-SPEC-01067. Although there is a well-documented history of weld hot crack susceptibility in the early development of the DOP-26 iridium alloy, a surface crack such as this had not been documented during welding at Los Alamos. In the interest of better understanding the cause; the product engineer/program recommended further examination of the crack. This report discusses the examination of the crack found in the weld cross section of simulant clad SC0234. Metallography, Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy techniques (EDS) where used in the analysis of the crack and the surrounding weld microstructure.

36 MATERIALS SCIENCE↗

Plan Position Indicator Hydrometeor Field Statistics (PPIHYD) Evaluation Data Product Version 1.0

The PPIHYD evaluation data product provides distinct hydrometeor field statistics calculated from U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility scanning radar plan position indicator (PPI) scans. These statistics include the equivalent reflectivity factor and Doppler spectral width percentiles, min/max values, and first four moments (mean, standard deviation, skewness, and kurtosis) of distinct hydrometeor features (clustered hydrometeor fields). Statistics also include morphological properties, water content and precipitation rate parameterization-based estimates, and thermodynamic properties interpolated using the Interpolated Sonde value-added product (INTERPSONDE VAP). The data set is organized in tabular form and is accompanied by mask arrays with corresponding indices. This straightforward file structure simplifies scanning radar data processing and renders this data set useful for process understanding and model evaluation studies. This report describes the data set and its processing algorithm and provides some examples.

54 ENVIRONMENTAL SCIENCES↗

ELECTROCHEMICAL CORROSION TESTS FOR TANK 241-AY-101 CORE 325 SEGMENTS 16R1 & 16R2

The interstitial liquid in the double-shell tank 241-AY-101 settled solids layer is below the hydroxide chemistry control limit required by HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Administrative Control 5.16, 'Corrosion Mitigation Controls'. Operating tanks outside of the specification may increase the propensity corrosion of the carbon steel wall. This report is concerned with generalized electrochemical corrosion mechanism that may occur at specific loci. All cyclic potentiodynamic polarization scans exhibited a negative hysteresis, scan reversing at lower current density, indicating that there was no pitting propensity. The general electrochemical corrosion rates ranged from 4.4E-02 to 1.5E-03 mpy with the first round of coupons, while the second round yielded corrosion rates of 2.5E-03 to 2.9E-02 mpy.

36 MATERIALS SCIENCE↗

Femtosecond Laser Additive Manufacturing of Multi-Material Layered Structures

Laser additive manufacturing (LAM) of a multi-material multi-layer structure was investigated using femtosecond fiber lasers. A thin layer of yttria-stabilized zirconia (YSZ) and a Ni–YSZ layer were additively manufactured to form the electrolyte and anode support of a solid oxide fuel cell (SOFC). A lanthanum strontium manganite (LSM) layer was then added to form a basic three layer cell. This single step process eliminates the need for binders and post treatment. Parameters including laser power, scan speed, scan pattern, and hatching space were systematically evaluated to obtain optimal density and porosity. This is the first report to build a complete and functional fuel cell by using the LAM approach.

36 MATERIALS SCIENCE↗

A search with Copernicus for interstellar N2 in diffuse clouds

Multiple Copernicus scans of two N2 band regions (near 958.5 and 960.2A) of Delta Sco and Epsilon Per are reported. The observations indicate upper limits for the number of N2 molecules equal to 1.0-3.8 times 10 to the -12th/sq cm and 1.2-4.4 times 10 to the -12th/sq cm, respectively; the limits depend on the cloud temperature. It is suggested that the limits are consistent with the column densities predicted by chemical models for diffuse interstellar clouds, and the predicted relative abundances are presented in terms of the ratio of N(N2)/(2N(H2) + N(Hl)).

Lutz, B. L.↗

Auroral X-ray detection from rocket overflights

Remote sensing of auroral X-rays from the topside can provide both local and global information concerning X-ray and energetic particle deposition within the middle atmosphere. Usually, contamination of X-ray detectors by corpuscular radiation can severely affect the scope and accuracy of the measurement. Preliminary results obtained with a rocket-borne instrument designed to operate cleanly in a precipitating particle environment are reported. Two dimensional images of the atmospheric bremsstrahlung X-ray sources were also constructed from the detector scan produced by payload translation and coning.

Goldberg, A.↗

Observations of the giant radio lobes region of Centaurus A with SAS 3

Observations of the X-ray flux from the extended radio lobes of the galaxy Centaurus A obtained with the SAS 3 observatory are reported. The 15 x 15 deg region that includes the lobes was mapped by superposing data from raster scans with the horizontal tubular collimator detectors, which have a 1.7 deg FWHM circular field of view. Data obtained is consistent with the presence of superposed emission from the point sources NGC 5128 and MX 1312-42, a previously unreported source detected by the Einstein Observatory IPC. Fluxes of 4.63 + or - 0.14 x 10 to the -10th and 4.6 + or - 0.6 x 10 to the -11th ergs/sq cm per sec were measured for NGC 5128 and MX 1312-42, respectively, with best fit power law spectra of indices 0.83 + or - 0.04 and 0.62 + or - 0.10 and hydrogen column densities of 1.23 + or - 0.10 x 10 to the 23rd and 9.7 + or - 15.0 x 10 to the 21st atoms/sq cm. Results imply an upper limit of 2.9 x 10 to the 11th for the X-ray emission from the extended radio lobes of Cen A between 2 and 10 keV, which indicates a lower limit to the magnetic field in the lobes of 1.6 x 10 to the -6th gauss.

Marshall, F. J.↗

Data-Base Software For Tracking Technological Developments

Technology Tracking System (TechTracS) computer program developed for use in storing and retrieving information on technology and related patent information developed under auspices of NASA Headquarters and NASA's field centers. Contents of data base include multiple scanned still images and quick-time movies as well as text. TechTracS includes word-processing, report-editing, chart-and-graph-editing, and search-editing subprograms. Extensive keyword searching capabilities enable rapid location of technologies, innovators, and companies. System performs routine functions automatically and serves multiple users.

Aliberti, James A.↗

Utricular otoconia of some amphibians have calcitic morphology

This report concerns the morphological features of otoconia removed from the inner ear of four amphibian species. Results from scanning electron microscopic examination are compared based on the site of origin. These results show that utricular otoconia have a mineral structure that mimics calcite, rather than the widely accepted idea that they are mineralized by calcium carbonate of the aragonite polymorph.

NASA Program Space Physiology and Countermeasures↗

STS-114: Post Launch MMT Briefing

Bill Parsons, Space Shuttle Program Manager, and Wayne Hill, Deputy Manager of the Space Shuttle Program, and Chair of the Mission Management Team talks about the flight day 2 of the Discovery. Bill noted that flight operations are extremely going on well. He also explained an unexpected debris event on a power ramp little ways down where LH2 ramp begins. Before flight and based from technical data, slight modifications were done on the power ramp to ensure safety of return to flight. Bill also noted that STS-114 is a test flight; all data collected and brought back by the crew will be analyzed to ensure that all information needed is sufficient to work on faults and defects and to make appropriate repairs. Wayne discussed on flight safety. He emphasized the need to thoroughly inspect the thermal protection system of the Orbiter to ensure safe entry. Inspection of still photographs from the ISS and the boom sensor system scan are the primary means to understand engineering data in terms of the immediate flight safety. He also reported accomplishments for the day such as survey of the Orbiter boom system, all the wing leading edge, RCC panels and the nose cap, to make sure these are in good shape and working well, and re-emphasized that these are primary methods to clear the thermal protection system of the Orbiter to prove that it is safe to come home on this flight.

Source record↗

Thorough characterization of a EUV mask

We reported that we were successful in our 45nm technology node device demonstration in February 2008 and 22nm node technology node device patterning in February 2009 using ASML's Alpha Demo Tool (ADT). In order to insert extreme ultraviolet (EUV) lithography at the 15nm technology node and beyond, we have thoroughly characterized one EUV mask, a so-called NOVACD mask. In this paper, we report on three topics, The first topic is an analysis of line edge roughness (LER) using a mask Scanning Electron Microscope (SEM), an Atomic Force Microscope (AFM) and the Actinic Inspection Tool (AIT) to compare resist images printed with the ASML ADT. The results of the analysis show a good correlation between the mask AFM and the mask SEM measurements, However, the resist printing results for the isolated space patterns are slightly different. The cause ofthis discrepancy may be resist blur, image log slope and SEM image quality and so on. The second topic is an analysis of mask topography using an AFM and relative reflectivity of mirror and absorber surface using the AIT, The AFM data show 6 and 7 angstrom rms roughness for mirror and absorber, respectively. The reflectivity measurements show that the mirror reflects EUV light about 20 times higher than absorber. The last topic is an analysis of a 32nm technology node SRAM cell which includes a comparison of mask SEM image, AIT image, resist image and simulation results. The ADT images of the SRAM pattern were of high quality even though the mask patters were not corrected for OPC or any EUV-specific effects. Image simulation results were in good agreement with the printing results.

36 MATERIALS SCIENCE↗

Morphological classification of bioaerosols from composting using scanning electron microscopy

Highlights: • Bioaerosols were captured using the filter method. • Bioaerosols were analysed using scanning electron microscope. • Bioaerosols were classified on the basis of morphology. • Single small cells were found more frequently than aggregates and larger cells. • Smaller cells may disperse further than heavier aggregate structures. - Abstract: This research classifies the physical morphology (form and structure) of bioaerosols emitted from open windrow composting. Aggregation state, shape and size of the particles captured are reported alongside the implications for bioaerosol dispersal after release. Bioaerosol sampling took place at a composting facility using personal air filter samplers. Samples were analysed using scanning electron microscopy. Particles were released mainly as small (<1 μm) single, spherical cells, followed by larger (>1 μm) single cells, with aggregates occurring in smaller proportions. Most aggregates consisted of clusters of 2–3 particles as opposed to chains, and were <10 μm in size. No cells were attached to soil debris or wood particles. These small single cells or small aggregates are more likely to disperse further downwind from source, and cell viability may be reduced due to increased exposure to environmental factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of Beam Intensity Effects in Fermilab Booster Synchrotron. Part I: Introduction, Tune and Chromaticity Scans of Beam Losses

Detrimental beam dynamics effects limit performance of high intensity rapid cycling synchrotrons (RCS) such as the 8 GeV Fermilab Booster. Here we report the results of comprehensive studies of various beam intensity dependent effects in the Booster. Part I covers the dependencies of the Booster beam intensity losses on the total number of protons per pulse and on key operational parameters such as the machine tunes and chromaticities. In Part II we cross-check two methods of the beam emittance measurements (the multi-wires proportional chambers and the ionization profile monitors), analyze the intensity dependent emittance growth effects and discuss the ultimate performance of the machine now and after foreseen and proposed upgrades.

43 PARTICLE ACCELERATORS↗

Energy Delivery Systems with Verifiable Trustworthiness (Final Report)

Energy Delivery Systems (EDS) must be verified to be free from intrusive and malicious software. One way of verifying this software is to perform device scans to detect malicious code. Because it is possible to have “fileless” malware that exists only in device (volatile) memory, offline scanning and even many forms of online scanning is insufficient for detection. This project (“Verify”) addresses this need by performing direct sampling of memory during device operation to detect unexpected or modified software while not interfering with device operation. The Verify project provides a proof-of-concept of detection by random sampling combined with remote software- and timing-based attestation methods for robust detection of in-memory threats. An external review of Verify was performed by our partner, General Electric (GE), and a summary of their findings is provided.

97 MATHEMATICS AND COMPUTING↗

Serial Scanning and Registration of High Resolution Quantitative Computed Tomography Volume Scans for the Determination of Local Bone Density Changes

Progress in development of the methods required to study bone remodeling as a function of time is reported. The following topics are presented: 'A New Methodology for Registration Accuracy Evaluation', 'Registration of Serial Skeletal Images for Accurately Measuring Changes in Bone Density', and 'Precise and Accurate Gold Standard for Multimodality and Serial Registration Method Evaluations.'

Whalen, Robert T.↗