Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample integrity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Towards a novel stellar opacity measurement scheme using stability properties of double ablation front structures

A novel method for bringing sample elements to hydrodynamic conditions relevant to the base of the solar convection zone is investigated. The method is designed in the framework of opacity measurements and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures. The physics of symmetric DAF structures is first studied in 1D geometries to assess the influence of tracer layers in the target. These results are used to propose an experimental design compatible with the OMEGA [Boehly et al., Opt. Commun. 133(1-6), 495–506 (1997)] laser. Radiative-hydrodynamic simulations conducted using the Chic code [Breil et al., Comput. Fluids 46, 161–167 (2011).] in 2D-axisymmetric geometries suggest that a Fe sample can be brought to an electron temperature of ∼160 eV and electron number density of ∼1.35 × 1023 cm−3. These parameters are reached during a 500 ps window with temporal variations of the order of 10 eV and 1022 cm−3, respectively. This allows for potential time-integrated spectral measurements. During that time, the sample is almost at local thermal equilibrium and 2D spatial gradients in the sample are less than 5% in a 360 μm diameter cylindrical volume, including the potential effects of Hot Electrons (HE) and typical uncertainties related to target fabrication and laser performances. The effects of HEs are assessed using an inline model in Chic. The HEs are found to deposit most of their energy in the cold and dense ablator between the two fronts, leading to a small efficiency loss on the DAF parameters. The calculations also suggest that negligible amounts of unabsorbed HEs are present in the probed volume, thus not affecting the atomic properties of the sample. Potential extensions of the current design to higher sample temperatures within the OMEGA capabilities are briefly discussed.

Colaïtis, A.↗

Release path temperatures of shock-compressed tin from dynamic reflectance and radiance measurements

Dynamic reflectance and radiance measurements were conducted for tin samples shock compressed to 35 GPa and released to 15 GPa using high explosives. We determined the reflectance of the tin samples glued to lithium fluoride windows using an integrating sphere with an internal xenon flashlamp as an illumination source. The dynamic reflectance (R) was determined at near normal incidence in four spectral bands with coverage in visible and near-infrared spectra. Uncertainties in R/R{sub 0} are <2%, and uncertainties in absolute reflectance are <5%. In complementary experiments, thermal radiance from the tin/glue/lithium fluoride interface was recorded with similar shock stress and spectral coverage as the reflectance measurements. The two sets of experiments were combined to obtain the temperature history of the tin surface with an uncertainty of <2%. The stress at the interface was determined from photonic Doppler velocimetry and combined with the temperatures to obtain temperature-stress release paths for tin. We discuss the relationship between the experimental release paths and release isentropes that begin on the principal shock Hugoniot.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

LAB4D: A low power, multi-GSa/s, transient digitizer with sampling timebase trimming capabilities

The LAB4D is a new application-specific integrated circuit (ASIC) of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) family, for use in direct wideband radio frequency digitization such as is used in ultrahigh energy neutrino and cosmic ray astrophysics. The LAB4D is a single channel switched-capacitor array (SCA) 12-bit sampler with integrated analog-to-digital converters (ADC), developed in the TSMC 0.25um process. The LAB4D, operating at 3.2GSa/s, contains 4096 total samples arranged in 32 windows, for a total record length of 1280ns. The 3dB bandwidth is approximately 1.3GHz, with a directly-coupled 50ohm input. This represents a factor of 16 increase in the sample depth and an increase in analog bandwidth and sampling depth in comparison to the previous generation LAB3 digitizer. Individually addressable windows allow for sampling and digitization to occur simultaneously, leading to nearly deadtime-free readout for kHz readout rates. All biases and current references are generated via internal digital-to-analog converters (DACs), resulting in a stand-alone digitizer with no additional support circuitry. In addition, the LAB4D contains sample cell timebase trimming capabilities, reducing the intrinsic sample-to-sample time variance to less than 5ps; an improvement of about 80%. This allows the LAB4D to be used in precision timing applications with minimal post-hoc calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Direct CP Violating Asymmetries in Charmless Decays of Strange Bottom Mesons and Bottom Baryons

We report measurements of direct CP--violating asymmetries in charmless decays of neutral bottom hadrons to pairs of charged hadrons with the upgraded Collider Detector at the Fermilab Tevatron. Using a data sample corresponding to 1 fb{sup -1} of integrated luminosity, we obtain the first measurements of direct CP violation in bottom strange mesons, A{sub CP}(B{sub s}{sup 0}{yields}K{sup -}{pi}{sup +})=+0.39{+-}0.15(stat){+-}0.08(syst), and bottom baryons, A{sub CP}({Lambda}{sub b}{sup 0}{yields}p{pi}{sup -})=+0.03{+-}0.17(stat){+-}0.05(syst) and A{sub CP}({Lambda}{sub b}{sup 0}{yields}pK{sup -})=+0.37{+-}0.17(stat){+-}0.03(syst). In addition, we measure CP violation in B{sup 0}{yields}K{sup +}{pi}{sup -} decays with 3.5{sigma} significance, A{sub CP}(B{sup 0}{yields}K{sup +}{pi}{sup -})=-0.086{+-}0.023(stat){+-}0.009(syst), in agreement with the current world average. Measurements of branching fractions of B{sub s}{sup 0}{yields}K{sup +}K{sup -} and B{sup 0}{yields}{pi}{sup +}{pi}{sup -} decays are also updated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Protein Solvation from Theory and Simulation: Exact Treatment of Coulomb Interactions in Three-Dimensional Theories

Solvation forces dominate protein structure and dynamics. Integral equation theories allow a rapid and accurate evaluation of the effect of solvent around a complex solute, without the sampling issues associated with simulations of explicit solvent molecules. Advances in integral equation theories make it possible to calculate the angle dependent average solvent structure around an irregular molecular solution. We consider two methodological problems here: the treatment of long-ranged forces without the use of artificial periodicity or truncations and the effect of closures. We derive a method for calculating the long-ranged Coulomb interaction contributions to three-dimensional distribution functions involving only a rewriting of the system of integral equations and introducing no new formal approximations. We show the comparison of the exact forms with those implied by the supercell method. The supercell method is shown to be a good approximation for neutral solutes whereas the new method does not exhibit the known problems of the supercell method for charged solutes. Our method appears more numerically stable with respect to thermodynamic starting state. We also compare closures including the Kovalenko–Hirata closure, the hypernetted-chain _HNC_ and an approximate three-dimensional bridge fu nction combined with the HNC closure. Comparisons to molecular dynamics results are made for water as well as for the protein solute bovine pancreatic trypsin inhibitor. The proposed equations have less severe approximations and often provide results which compare favorably to molecular dynamics simulation where other methods fail.

59 BASIC BIOLOGICAL SCIENCES↗

A simple molecular mechanics integrator in mixed rigid body and dihedral angle space

We propose a numerical scheme to integrate equations of motion in a mixed space of rigid-body and dihedral angle coordinates. The focus of the presentation is biomolecular systems and the framework is applicable to polymers with tree-like topology. By approximating the effective mass matrix as diagonal and lumping all bias torques into the time dependencies of the diagonal elements, we take advantage of the formal decoupling of individual equations of motion. We impose energy conservation independently for every degree of freedom and this is used to derive a numerical integration scheme. The cost of all auxiliary operations is linear in the number of atoms. By coupling the scheme to one of two popular thermostats, we extend the method to sample constant temperature ensembles. We demonstrate that the integrator of choice yields satisfactory stability and is free of mass-metric tensor artifacts, which is expected by construction of the algorithm. Two fundamentally different systems, viz., liquid water and an α-helical peptide in a continuum solvent are used to establish the applicability of our method to a wide range of problems. The resultant constant temperature ensembles are shown to be thermodynamically accurate. The latter relies on detailed, quantitative comparisons to data from reference sampling schemes operating on exactly the same sets of degrees of freedom.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linking Associations of Rare Low-Abundance Species to Their Environments by Association Networks

Studies of microbial communities by targeted sequencing of rRNA genes lead to recovering numerous rare low-abundance taxa with unknown biological roles. We propose to study associations of such rare organisms with their environments by a computational framework based on transformation of the data into qualitative variables. Namely, we analyze the sparse table of putative species or OTUs (operational taxonomic units) and samples generated in such studies, also known as an OTU table, by collecting statistics on co-occurrences of the species and on shared species richness across samples. Based on the statistics we built two association networks, of the rare putative species and of the samples respectively, using a known computational technique, Association networks (Anets) developed for analysis of qualitative data. Clusters of samples and clusters of OTUs are then integrated and combined with metadata of the study to produce a map of associated putative species in their environments. We tested and validated the framework on two types of microbiomes, of human body sites and that of the Populus tree root systems. We show that in both studies the associations of OTUs can separate samples according to environmental or physiological characteristics of the studied systems.

54 ENVIRONMENTAL SCIENCES↗

Precise measurement of the tt¯ production cross-section and lepton differential distributions in eμ dilepton events from s=13TeVpp collisions with the ATLAS detector

The inclusive top quark pair (tt¯$$t\bar{t}$$) cross-section σtt¯$$\sigma _{t\bar{t}}$$ has been measured in proton–proton collisions at s=13TeV$$\sqrt{s}=13\,\text {TeV}$$, using 140fb-1$$140\,{\text {fb}^{-1}} $$ of data collected by the ATLAS experiment at the Large Hadron Collider. Using events with an opposite-charge eμ$$e\mu $$ pair and b-tagged jets, the cross-section is measured to be: σtt¯=829.3±1.3(stat)±8.0(syst)±7.3(lumi)±1.9(beam)pb,$$\begin{aligned} \sigma _{t\bar{t}} & = 829.3\pm 1.3\,\mathrm {(stat)}\ \pm 8.0\,\mathrm {(syst)}\ \pm 7.3\,\mathrm {(lumi)}\ \\ & \quad \pm 1.9\,\mathrm {(beam)}\,\textrm{pb}, \end{aligned}$$where the uncertainties reflect the limited size of the data sample, experimental and theoretical systematic effects, the integrated luminosity, and the proton beam energy, giving a total uncertainty of 1.3%. The result is used to determine the top quark pole mass via the dependence of the predicted cross-section on mtpole$${m_{t}^\textrm{pole}}$$, giving mtpole=172.8-1.7+1.5$${m_{t}^\textrm{pole}}=172.8^{+1.5}_{-1.7}$$ GeV$$\text {GeV}$$. The same event sample is used to measure absolute and normalised differential cross-sections for the tt¯→eμνν¯bb¯$$t\bar{t} \rightarrow e\mu u \bar{ u }b\bar{b} $$ process as a function of single-lepton and dilepton kinematic variables. Complementary measurements of eμbb¯$$e\mu b\bar{b} $$ production, treating both tt¯$$t\bar{t}$$ and Wt events as signal, are also provided. Both sets of differential cross-sections are compared to the predictions of various Monte Carlo event generators, demonstrating that the state-of-the-art generators Powheg MiNNLO and Powhegbb4l describe the data better than Powheghvq.

Aad, G↗

Results of Routine Strip Effluent Hold Tank and Decontaminated Salt Solution Hold Tank Samples from Modular Caustic-Side Solvent Extraction Unit during Macrobatch 5 Operations

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the "microbatches" of Integrated Salt Disposition Project (ISDP) Salt Batch ("Macrobatch") 5 have been analyzed for 238 Pu, 90 Sr, 137 Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and the previous set of results for Macrobatch 4 samples indicate generally consistent operations. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in the Actinide Removal process (ARP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechatronic Design and Control of a Waste Paper Sorting System for Efficient Recycling

Sorting of paper into compatible grades is a necessary step prior to recycling. Current method of manually sorting is tedious, slow, and expensive. Hence, significant part of the waste paper stream is sent to the landfill. High speed automation of the sorting process will improve the cost efficiency and increase the amount of paper recycled significantly. There have been recent developments in automation of this process. Mechanisms for the distribution of the papers from a bale onto a moving conveyor and the pneumatic actuation to deflect papers into different streams are well established. Correct identification of the sample in real-time before the sample reaches the actuation station still remains a challenge since different types of paper and board samples are mixed in a waste stream, and has a lot of variation in terms of color, chemical composition, coating, and prints in black and white and color to different degrees. This is primarily due to the lack of satisfactory sensors and sensor fusion algorithms for sample identification in real-time. In this report, we identify key parameters that must be measured (lignin, stiffness, color gloss), sensor design, and integration of the output from sensors to interpret the type of sample using a fuzzy inference system. Results show that the sensor system proposed is capable of identifying the samples at 90% accuracy. The sensor system can be integrated onto a conveyor and actuation system for automated sorting.

36 MATERIALS SCIENCE↗

Conversions between gas-phase metallicities in MaNGA

ABSTRACT We present polynomial conversions between each of 11 different strong line gas-phase metallicity calibrations, each based on ∼1.1 million star-forming spaxels in the public Sloan Digital Sky Survey (SDSS) Data Release 15 (DR15) Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. For this sample, which is ∼20 times larger than previous works, we present fifth-order polynomial fits for each of 110 possible calibration conversions, for both Small Magellanic Cloud-type and Milky Way-type dust corrections. The typical 2σ scatter around our polynomial fits is 0.1 dex; we present the range over which the metallicities are valid. Conversions between metallicities which rely on the same set of line ratios, or a heavily shared set of emission lines, have reduced scatter in their conversions relative to those conversions with little overlap in required emission lines. Calibration conversions with less consistent sets of emission lines also have increased galaxy-to-galaxy variability, and this variability can account for up to 35 per cent of the total scatter. We also compare our conversions to previous work with the single fibre SDSS DR7 spectra along with higher spatial resolution data from the TYPHOON Integral Field Spectroscopy survey, resulting in comparison samples with spatial resolutions from several kpc down to ∼100 pc. Our metallicity conversions, obtained with the large sample of MaNGA, are robust against the influence of diffuse ionized gas, redshift, effective radius, and spatial blurring, and are therefore consistent across both integrated spectra and the high-resolution integral field spectroscopy data.

79 ASTRONOMY AND ASTROPHYSICS↗

RESULTS OF ROUTINE STRIP EFFLUENT HOLD TANK AND DECONTAMINATED SALT SOLUTION HOLD TANK SAMPLES FROM MODULAR CAUSTIC-SIDE SOLVENT EXTRACTION UNIT DURING MACROBATCH 3 OPERATIONS

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the 'microbatches' of Integrated Salt Disposition Project (ISDP) Salt Batch ('Macrobatch') 3 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by Inductively Coupled Plasma Emission Spectroscopy (ICPES). The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and the previous set of results for Macrobatch 3 samples indicate consistent operations. However, the Decontamination Factors for plutonium and strontium removal have declined in Macrobatch 3, compared to Macrobatch 2. This may be due to the differences in the Pu concentration or the bulk chemical concentrations in the feed material. SRNL is considering the possible reasons for this decline. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in ARP. During operation of the ISDP, quantities of salt waste are processed through the Actinide Removal Process (ARP) and MCU in batches of {approx}3800 gallons. Monosodium titanate (MST) is used in ARP to adsorb actinides and strontium from the salt waste and the waste slurry is then filtered prior to sending the clarified salt solution to MCU. The MCU uses solvent extraction technology to extract cesium from salt waste and concentrate cesium in an acidic aqueous stream (Strip Effluent - SE), leaving a decontaminated caustic salt aqueous stream (Decontaminated Salt Solution - DSS). Sampling occurs in the Decontaminated Salt Solution Hold Tank (DSSHT) and Strip Effluent Hold Tank (SEHT) in the MCU process. The MCU sample plan requires that batches be sampled and analyzed for plutonium and strontium content by Savannah River National Lab (SRNL) to determine MST effectiveness. The cesium measurement is used to monitor cesium removal effectiveness and the inductively coupled plasma emission spectroscopy (ICPES) is used to monitor inorganic carryover.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparing optical four-flux model results with experimental data obtained by integrating sphere measurements

Four-flux theory is a way to model scattering through multiple layers of a system based on diffuse and collimated properties. When compared with measurement results obtained using an integrating sphere or a goniophotometer, an approximation is often made as the physical instrument cannot separate the collimated component from the diffuse light scattered in the forward direction. This paper tries to clarify the meaning of the word diffuse for the different cases and outlines simple corrections to improve the accuracy when comparing four-flux models and measured data based on sample haze and the geometry of the integrating sphere.

Bilokur, Maryna (ORCID:0000000191839650)↗

Measurement of top quark polarisation in t-channel single top quark production

Our first measurement of the top quark spin asymmetry, sensitive to the top quark polarisation, in t-channel single top quark production is presented. It is based on a sample of pp collisions at a centre-of-mass energy of 8 TeV corresponding to an integrated luminosity of 19.7 fb -1 . A high-purity sample of t-channel single top quark events with an isolated muon is selected. Signal and background components are estimated using a fit to data. Furthermore, a differential cross section measurement, corrected for detector effects, of an angular observable sensitive to the top quark polarisation is performed. The differential distribution is used to extract a top quark spin asymmetry of 0.26 ± 0.03 (stat) ± 0.10 (syst), which is compatible with a p-value of 4.6% with the standard model prediction of 0.44.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the centrality and pseudorapidity dependence of the integrated elliptic flow in lead–lead collisions at $\sqrt{s_{\mathrm {NN}}}=2.76$ TeV with the ATLAS detector

The integrated elliptic flow of charged particles produced in Pb+Pb collisions at $\sqrt{s_{\mathrm {NN}}} TeV has been measured with the ATLAS detector using data collected at the Large Hadron Collider. The anisotropy parameter, v 2 , was measured in the pseudorapidity range |η| ≤ 2.5 with the event-plane method. In order to include tracks with very low transverse momentum p T , thus reducing the uncertainty in v 2 integrated over p T , a 1 μ b -1 data sample recorded without a magnetic field in the tracking detectors is used. The centrality dependence of the integrated v 2 is compared to other measurements obtained with higher p T thresholds. The integrated elliptic flow is weakly decreasing with |η|. The integrated v 2 transformed to the rest frame of one of the colliding nuclei is compared to the lower-energy RHIC data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗