Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample identifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Aluminum Clad Spent Nuclear Fuel Task 4: Performance of Aluminum SNF in Dry Storage Experiment Test Plan

This document presents the activities to be performed in support of understanding the performance of aluminum spent nuclear fuel (ASNF) in dry storage. These activities will visually examine and acquire baseline samples of as-irradiated ATR fuel assembly components to determine fuel condition and the morphology of the aluminum oxyhydroxides present on the fuel external surfaces. Because the boehmite phase of oxyhydroxide is projected to be a significant contributor to radiolytic hydrogen production and general corrosion, being able to quantify its presence is of major importance to long term storage of aluminum spent nuclear fuel. Baseline samples will be taken from irradiated end adapters, removed from ATR SNF elements, stored in the ATR Canal. These will be transferred to Idaho National Laboratory (INL) Materials and Fuels Complex (MFC) to perform non-destructive and destructive testing to determine the degree of hydration of the wet-stored aluminum components prior to drying and air storage. Examination of the dry stored SNF at Idaho Nuclear Technology and Engineering Center (INTEC) in CPP-603 Irradiated Fuel Storage Facility (IFSF) will allow the opportunity to identify gross degradation and as conditions permit, sample the surface oxide on fueled and un-fueled portions of the stored assemblies. The information resulting from analysis of the ATR Canal samples will be used to support validation of surrogate samples prepared under Task 6, sample surrogate preparation, and used in Task 1, oxyhydroxide layer behavior and chemistry, Task 2, oxide layer radiolytic gas generation, and Task 5, oxide layer response to drying. Surface oxide samples collected from SNF in IFSF dry storage will SNF dry storage prediction modeling from Task 3, sealed and vented system episodic breathing and gas generation prediction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a new approach based on midwave infrared spectroscopy for post-consumer black plastic waste sorting in the recycling industry

Highlights: • MWIR reflectance contact measurements were performed on post-consumer waste. • MWIR absorptions are found to be potentially suitable for black plastic resin classification. • MWIR is also potentially suitable for separation of coloured plastic and wood based products. • Atmospheric transmittance simulations suggest feasibility of stand-off measurements. - Abstract: Waste sorting is key to the process of waste recycling. Exact identification of plastic resin and wood products using Near Infrared (NIR, 1–1.7 µm) sensing is currently in use. Yet, dark targets characterized by low reflectance, such as black plastics, are hard to identify by this method. Following the recent success of Midwave Infrared (MWIR, 3–12 µm) measurements to identify coloured plastic polymers, the aim of this study was to assess whether this technique is applicable to sorting black plastic polymers and wood products. We performed infrared reflectance contact measurements of 234 plastic samples and 29 samples of wood and paper products. Plastic samples included black, coloured and transparent Polyethylene Terephthalate (PET), Polyethylene (PE), Polyvinyl Chloride (PVC), Polypropylene (PP), Polylactic acid (PLA) and Polystyrene (PS). The spectral signatures of the black and coloured plastic samples were compared with clear plastic samples and signatures documented in the literature to identify the polymer spectral features in the presence of coloured material. This information was used to determine the spectral bands that best suit the sorting of black plastic polymers. The main NIR-MWIR absorption features of wood, cardboard and paper were identified as well according to the spectral measurements. Good agreement was found between our measurements and the absorption features documented in the literature. The new approach using MWIR spectral features appears to be useful for black plastics as it overcomes some of the limitations in the NIR region to identify them. The main limitation of this technique for industrial applications is the trade-off between the signal-to-noise ratio of the sensor operating in standoff mode and the speed at which waste is moved under the sensor. This limitation can be resolved by reducing the system’s spectral resolution to 16 cm{sup −1}, which allows for faster spectra acquisition while maintaining a reasonable signal-to-noise ratio.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface Water Disinfection Byproducts and Organic Matter Characterization Data Associated with: “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream”

This dataset is associated with the publication “Disinfection byproducts formed during drinking water treatment reveal an export control point for dissolved organic matter in a subalpine headwater stream” published in Water Research X (Leonard et al. 2022; https://doi.org/10.1016/j.wroa.2022.100144). The associated study analyzed temporal trends from the Town of Crested Butte water treatment facility and synoptic sampling at Coal Creek in Crested Butte, Colorado, US. This work demonstrates how drinking water quality archives combined with synoptic sampling and targeted analyses can be used to identify and understand export control points for dissolved organic matter. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) metadata and international geo-sample number (IGSN) mapping file; (4) dissolved organic carbon (DOC), ultraviolet absorbance at 254 nanometers (UV254), total nitrogen (TN), and specific ultraviolet absorbance (SUVA) data; (5) disinfection bioproduct formation potential (DBP-FP) data; (6) readme; (7) methods codes; (8) water collection protocol; (9) folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory); and (10) folder of excitation emissions matrix (EEM) spectra. The FTICR folder contains a file of DOC (measured as non-purgeable organic carbon; NPOC) used for FTICR sample preparation. The FTICR folder also contains three subfolders: one subfolder containing the raw .xml data files, one containing the processed data, and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .dat, .R, .ref, or .xml

54 ENVIRONMENTAL SCIENCES↗

Evaluating various composite sampling modes for detecting pathogenic SARS-CoV-2 virus in raw sewage

Inadequate sampling approaches to wastewater analyses can introduce biases, leading to inaccurate results such as false negatives and significant over- or underestimation of average daily viral concentrations, due to the sporadic nature of viral input. To address this challenge, we conducted a field trial within the University of Tennessee residence halls, employing different composite sampling modes that encompassed different time intervals (1 h, 2 h, 4 h, 6 h, and 24 h) across various time windows (morning, afternoon, evening, and late-night). Our primary objective was to identify the optimal approach for generating representative composite samples of SARS-CoV-2 from raw wastewater. Utilizing reverse transcription-quantitative polymerase chain reaction, we quantified the levels of SARS-CoV-2 RNA and pepper mild mottle virus (PMMoV) RNA in raw sewage. Our findings consistently demonstrated that PMMoV RNA, an indicator virus of human fecal contamination in water environment, exhibited higher abundance and lower variability compared to pathogenic SARS-CoV-2 RNA. Significantly, both SARS-CoV-2 and PMMoV RNA exhibited greater variability in 1 h individual composite samples throughout the entire sampling period, contrasting with the stability observed in other time-based composite samples. Through a comprehensive analysis of various composite sampling modes using the Quade Nonparametric ANCOVA test with date, PMMoV concentration and site as covariates, we concluded that employing a composite sampler during a focused 6 h morning window for pathogenic SARS-CoV-2 RNA is a pragmatic and cost-effective strategy for achieving representative composite samples within a single day in wastewater-based epidemiology applications. This method has the potential to significantly enhance the accuracy and reliability of data collected at the community level, thereby contributing to more informed public health decision-making during a pandemic.

sampling timing↗

MolDiscovery: learning mass spectrometry fragmentation of small molecules

Identification of small molecules is a critical task in various areas of life science. Recent advances in mass spectrometry have enabled the collection of tandem mass spectra of small molecules from hundreds of thousands of environments. To identify which molecules are present in a sample, one can search mass spectra collected from the sample against millions of molecular structures in small molecule databases. The existing approaches are based on chemistry domain knowledge, and they fail to explain many of the peaks in mass spectra of small molecules. Here, we present molDiscovery, a mass spectral database search method that improves both efficiency and accuracy of small molecule identification by learning a probabilistic model to match small molecules with their mass spectra. A search of over 8 million spectra from the Global Natural Product Social molecular networking infrastructure shows that molDiscovery correctly identify six times more unique small molecules than previous methods.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SCA Tools - SCRM Value Add or Lossy Noise Machines

Software supply chain risk management (SCRM) depends upon accurate information regarding the software components that comprise any given software system. The collection of components included in a software package can be organized within a software bill of materials, or SBOM. SBOMs are ideally generated when the software components are put together, such as at compile time, but for many reasons that has not and is not always possible. For example, legacy or proprietary software packages often do not have SBOMs available to downstream consumers of that software. It’s not just end users that are affected, manufacturers themselves also must deal with this problem. To answer these questions, the market has seen the rise of several commercial software composition analysis (SCA) tools. These tools aim to peer into completed software systems, automatically identifying hidden software dependencies and looking up known vulnerabilities associated with those dependencies to enable end-users to enhance their cyber supply chain risk management processes. These tools are potentially a huge boon to end users of legacy and proprietary software – and a potential bane, depending on how accurate they are. This research asks that question – how accurate are currently available binary SCA tools – and provides answers to several other questions: What does it mean to be “accurate”? What limitations do the tools have in identifying common edge cases that take place in modern software development? Can they help you avoid a devastating supply chain attack, or is it all just noise? After researching SCA tools on the market, we identified three vendors that fit our use case and would provide analysis on compiled binaries. Using these tools, we submitted firmware for critical infrastructure devices for analysis and SBOM generation. The SBOM outputs were then cross referenced with SBOMs generated through manual analysis for comparison. In addition to the firmware samples, we also submitted edge case samples based off a popular open-source library that were specifically crafted to evaluate each tools’ ability to accurately identify components. These samples were customized to be consistent with modifications we have seen in modern software development as well as a couple that are representative of supply chain attacks.

97 MATHEMATICS AND COMPUTING↗

DESI z ≳ 5 Quasar Survey. I. A First Sample of 400 New Quasars at z ~ 4.7–6.6

We report the first results of a high-redshift (z ≳ 5) quasar survey using the Dark Energy Spectroscopic Instrument (DESI). As a DESI secondary target program, this survey is designed to carry out a systematic search and investigation of quasars at 4.8 < z < 6.8. The target selection is based on the DESI Legacy Imaging Surveys (the Legacy Surveys) DR9 photometry, combined with the Pan-STARRS1 data and J-band photometry from public surveys. A first quasar sample has been constructed from the DESI Survey Validation 3 (SV3) and first-year observations until 2022 May. This sample includes more than 400 new quasars at redshift 4.7 ≤ z < 6.6, down to 21.5 magnitude (AB) in the z band, discovered from 35% of the entire target sample. Remarkably, there are 220 new quasars identified at z ≥ 5, more than one-third of existing quasars previously published at this redshift. The observations so far result in an average success rate of 23% at z > 4.7. The current spectral data set has already allowed analysis of interesting individual objects (e.g., quasars with damped Lyα absorbers and broad absorption line features), and statistical analysis will follow the survey's completion. A set of science projects will be carried out leveraging this program, including quasar luminosity function, quasar clustering, intergalactic medium, quasar spectral properties, intervening absorbers, and properties of early supermassive black holes. Additionally, a sample of 38 new quasars at z ~ 3.8–5.7 discovered from a pilot survey in the DESI SV1 is also published in this paper.

79 ASTRONOMY AND ASTROPHYSICS↗

Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Identification of blind geothermal resources in Surprise Valley, CA, using publicly available groundwater well water quality data

Geothermal resource exploration is generally limited to areas with surface expressions of thermal activity (fumaroles and hot springs), or relies on expensive geophysical exploration techniques. The hidden subsurface distribution of geothermal fluids has been identified using a free and publicly available water quality dataset from agricultural and domestic water wells in Surprise Valley, northeastern California. Thermally evolved waters in Surprise Valley have element ratios that vary in response to Ca carbonate and Mg silicate mineral precipitation, and have elevated total dissolved solids (TDS). The arid climate in Surprise Valley leads to surface water evaporation in a closed basin, producing high TDS Na-Cl-CO 3 -SO 4 brines in three ephemeral alkali lakes and in shallow groundwater under elevated soil CO 2 conditions. Evaporated fluids in Surprise Valley follow a chemical divide that leads to Ca carbonate and Mg silicate mineral precipitation. Plots of dissolved element ratios can be used to distinguish groundwater affected by evaporation from water affected by thermal water-rock interaction, however it is challenging to select components for plotting that best illustrate different fluid evolution mechanisms. Here, we use a principal component analysis of centered log-ratio transformed data, coupled with geochemical models of fluid evaporation and thermal mixing pathways, to identify components to plot that distinguish between groundwater samples influenced by evaporation from those influenced by thermal processes. We find that groundwater samples with a thermal signature come from wells that define a coherent, linear geographical distribution that closely matches the location of known and inferred faults. Finally, modification of the general approach employed here provides promise for identifying blind geothermal resources in other locations, by applying low-cost geochemical modeling and statistical techniques to areas where large groundwater quality geochemical datasets are available.

15 GEOTHERMAL ENERGY↗

Accelerating Nature: Induced Atomic Order in Equiatomic FeNi

Abstract The production of locally atomically ordered FeNi (known by its meteoric mineral name, tetrataenite) is confirmed in bulk samples by simultaneous conversion X‐ray and backscattered γ‐ray 57 Fe Mössbauer spectroscopy. Up to 22 volume percent of the tetragonal tetrataenite phase is quantified in samples thermally treated under simultaneous magnetic‐ and stress‐field conditions for a period of 6 weeks, with the remainder identified as the cubic FeNi alloy. In contrast, all precursor samples consist only of the cubic FeNi alloy. Data from the processed alloys are validated using Mössbauer parameters derived from natural meteoritic tetrataenite. The meteoritic tetrataenite exhibits a substantially higher degree of atomic order than do the processed samples, consistent with their low uniaxial magnetocrystalline anisotropy energy of ≈1 kJ·m −3 . These results suggest that targeted refinements to the processing conditions of FeNi will foster greater atomic order and increased magnetocrystalline anisotropy, leading to an enhanced magnetic energy product. These outcomes also suggest that deductions concerning paleomagnetic conditions of the solar system, as derived from meteoritic data, may warrant re‐examination and re‐evaluation. Additionally, this work strengthens the argument that tetrataenite may indeed become a member of the advanced permanent magnet portfolio, helping to meet rapidly escalating green energy imperatives.

36 MATERIALS SCIENCE↗

Characterization of the VVV Survey RR Lyrae Population across the Southern Galactic Plane

Deep near-IR images from the VISTA Variables in the Vía Láctea (VVV) Survey were used to search for RR Lyrae stars in the Southern Galactic plane. A sizable sample of 404 RR Lyrae of type ab stars was identified across a thin slice of the fourth Galactic quadrant (295° < ℓ < 350°, −2.°24 < b < −1.°05). The sample’s distance distribution exhibits a maximum density that occurs at the bulge tangent point, which implies that this primarily Oosterhoff type I population of RRab stars does not trace the bar delineated by their red clump counterparts. The bulge RR Lyrae population does not extend beyond ℓ ∼ 340°, and the sample’s spatial distribution presents evidence of density enhancements and substructure that warrants further investigation. Indeed, the sample may be employed to evaluate Galactic evolution models, and is particularly lucrative since half of the discovered RR Lyrae are within reach of Gaia astrometric observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Host-specific and tissue-dependent orchestration of microbiome community structure in traditional rice paddy ecosystems

Abstract Background and aim Rice and duckweed are two monocotyledonous plants that naturally coexist in paddy fields. While the presence of duckweed in paddy fields significantly improves rice productivity, the interplay between soil microbes and the two plant hosts in this agroecosystem remains unexplored. Methods We compared the bacterial community structure between duckweed, rice and soil from multiple rice paddies. We also isolated bacteria from these communities and characterized their modes of bacterial colonization and plant growth-promotion using model plants. Results Our data indicate that host-specific and tissue-dependent factors reproducibly orchestrate the bacterial community structure associated with their plant hosts. This is corroborated by results from culture-dependent approaches in which the dominant genus Pantoea isolated from rice aerial tissues can strongly attach and colonize gnotobiotic duckweed in spite of the low representation of this bacterial genus in the natural duckweed microbiome. Our study identified a core of 254 bacterial taxa that are consistently found in all rice and duckweed tissue samples from rice paddy fields. Furthermore, characterizing auxin-producing bacteria isolates from both plant species identified potential plant growth-promoting bacteria that may improve growth for both duckweed and rice in paddy fields. Conclusions Results from this work provide evidence for the importance of the host tissue and species context in determining plant colonization by microbes in the paddy field system. The resources generated in this study could facilitate the agronomic deployment of microbes for more sustainable rice production.

Agriculture↗

A PIXE Study of Trace Elements in Sediments of Toledo River, Parana, Brazil

In this work we characterize sediment samples from several points in the River Toledo--PR, using the PIXE (Particle Induced X-Ray Emission) spectroscopy technique, in order to quantify trace elements in these samples aiming to provide information about pollution levels for trace elements. The samples were collected in six points of river, during a period of twelve months (12/2001 to 11/2002). The collected material was air-dried at room temperature and then pressed in pellets. The samples were irradiated under vacuum using a H beam of 2,39 MeV in the LAMFI (Laboratorio de Analises de Materials por Feixe Ionico). Produced x-rays were detected using a Si(Li) detector and a standard electronics. Using the Axil program to analyze PIXE spectra it was possible to identify and quantify some elements present in the samples. A multi-elemental referenced material (Buffalo River sediment--RM 8704) was used to validate the PIXE analysis with thick targets. Twelve months of monitoring of six river points were analyzed and these allowed us to identify 18 elements such as Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr e Pb. The following elements were monitored: V, Cr, Mn, Co, Ni, Cu, Zn e Pb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

DIFFUSE Ly{alpha} EMITTING HALOS: A GENERIC PROPERTY OF HIGH-REDSHIFT STAR-FORMING GALAXIES

Using a sample of 92 UV continuum-selected, spectroscopically identified galaxies with (z) = 2.65, all of which have been imaged in the Ly{alpha} line with extremely deep narrow-band imaging, we examine galaxy Ly{alpha} emission profiles to very faint surface brightness limits. The galaxy sample is representative of spectroscopic samples of Lyman break galaxies (LBGs) at similar redshifts in terms of apparent magnitude, UV luminosity, inferred extinction, and star formation rate and was assembled without regard to Ly{alpha} emission properties. Approximately 45% (55%) of the galaxy spectra have Ly{alpha} appearing in net absorption (emission), with {approx_equal} 20% satisfying commonly used criteria for the identification of 'Ly{alpha} emitters' (LAEs; W{sub 0}(Ly{alpha}) {>=} 20 A). We use extremely deep stacks of rest-UV continuum and continuum-subtracted Ly{alpha} images to show that all sub-samples exhibit diffuse Ly{alpha} emission to radii of at least 10'' ({approx}80 physical kpc). The characteristic exponential scale lengths for Ly{alpha} line emission exceed that of the {lambda}{sub 0} = 1220 A UV continuum light by factors of {approx}5-10. The surface brightness profiles of Ly{alpha} emission are strongly suppressed relative to the UV continuum light in the inner few kpc, by amounts that are tightly correlated with the galaxies' observed spectral morphology; however, all galaxy sub-subsamples, including that of galaxies for which Ly{alpha} appears in net absorption in the spectra, exhibit qualitatively similar diffuse Ly{alpha} emission halos. Accounting for the extended Ly{alpha} emission halos, which generally would not be detected in the slit spectra of individual objects or with typical narrow-band Ly{alpha} imaging, increases the total Ly{alpha} flux (and rest equivalent width W{sub 0}(Ly{alpha})) by an average factor of {approx}5, and by a much larger factor for the 80% of LBGs not classified as LAEs. We argue that most, if not all, of the observed Ly{alpha} emission in the diffuse halos originates in the galaxy H II regions but is scattered in our direction by H I gas in the galaxy's circum-galactic medium. The overall intensity of Ly{alpha} halos, but not the surface brightness distribution, is strongly correlated with the emission observed in the central {approx}1''-more luminous halos are observed for galaxies with stronger central Ly{alpha} emission. We show that whether or not a galaxy is classified as a giant 'Ly{alpha} blob' (LAB) depends sensitively on the Ly{alpha} surface brightness threshold reached by an observation. Accounting for diffuse Ly{alpha} halos, all LBGs would be LABs if surveys were sensitive to 10 times lower Ly{alpha} surface brightness thresholds; similarly, essentially all LBGs would qualify as LAEs.

79 ASTRONOMY AND ASTROPHYSICS↗

A comparison of cosmological models using time delay lenses

The use of time-delay gravitational lenses to examine the cosmological expansion introduces a new standard ruler with which to test theoretical models. The sample suitable for this kind of work now includes 12 lens systems, which have thus far been used solely for optimizing the parameters of ΛCDM. In this paper, we broaden the base of support for this new, important cosmic probe by using these observations to carry out a one-on-one comparison between competing models. The currently available sample indicates a likelihood of ∼70%-80% that the R {sub h} = ct universe is the correct cosmology versus ∼20%-30% for the standard model. This possibly interesting result reinforces the need to greatly expand the sample of time-delay lenses, e.g., with the successful implementation of the Dark Energy Survey, the VST ATLAS survey, and the Large Synoptic Survey Telescope. In anticipation of a greatly expanded catalog of time-delay lenses identified with these surveys, we have produced synthetic samples to estimate how large they would have to be in order to rule out either model at a ∼99.7% confidence level. We find that if the real cosmology is ΛCDM, a sample of ∼150 time-delay lenses would be sufficient to rule out R {sub h} = ct at this level of accuracy, while ∼1000 time-delay lenses would be required to rule out ΛCDM if the real universe is instead R {sub h} = ct. This difference in required sample size reflects the greater number of free parameters available to fit the data with ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-Scale Characterization of Porosity and Cracks in Silicon Carbide Cladding after Transient Reactor Test Facility Irradiation

Silicon carbide (SiC) ceramic matrix composite (CMC) cladding is currently being pursued as one of the leading candidates for accident-tolerant fuel (ATF) cladding for light water reactor applications. The morphology of fabrication defects, including the size and shape of voids, is one of the key challenges that impacts cladding performance and guarantees reactor safety. Therefore, quantification of defects’ size, location, distribution, and leak paths is critical to determining SiC CMC in-core performance. This research aims to provide quantitative insight into the defect’s distribution under multi-scale characterization at different length scales before and after different Transient Reactor Test Facility (TREAT) irradiation tests. A non-destructive multi-scale evaluation of irradiated SiC will help to assess critical microstructural defects from production and/or experimental testing to better understand and predict overall cladding performance. X-ray computed tomography (XCT), a non-destructive, data-rich characterization technique, is combined with lower length scale electronic microscopic characterization, which provides microscale morphology and structural characterization. This paper discusses a fully automatic workflow to detect and analyze SiC-SiC defects using image processing techniques on 3D X-ray images. Following the XCT data analysis, advanced characterizations from focused ion beam (FIB) and transmission electron microscopy (TEM) were conducted to verify the findings from the XCT data, especially quantitative results from local nano-scale TEM 3D tomography data, which were utilized to complement the 3D XCT results. In this work, three SiC samples (two irradiated and one unirradiated) provided by General Atomics are investigated. The irradiated samples were irradiated in a way that was expected to induce cracking, and indeed, the automated workflow developed in this work was able to successfully identify and characterize the defects formation in the irradiated samples while detecting no observed cracking in the unirradiated sample. These results demonstrate the value of automated XCT tools to better understand the damage and damage propagation in SiC-SiC structures for nuclear applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Forensic Inferences Using Iterative Multidimensional Statistics

Nuclear forensics involves the analysis of interdicted nuclear material for specific material characteristics (referred to as 'signatures') that imply specific geographical locations, production processes, culprit intentions, etc. Predictive signatures rely on expert knowledge of physics, chemistry, and engineering to develop inferences from these material characteristics. Comparative signatures, on the other hand, rely on comparison of the material characteristics of the interdicted sample (the 'questioned sample' in FBI parlance) with those of a set of known samples. In the ideal case, the set of known samples would be a comprehensive nuclear forensics database, a database which does not currently exist. In fact, our ability to analyze interdicted samples and produce an extensive list of precise materials characteristics far exceeds our ability to interpret the results. Therefore, as we seek to develop the extensive databases necessary for nuclear forensics, we must also develop the methods necessary to produce the necessary inferences from comparison of our analytical results with these large, multidimensional sets of data. In the work reported here, we used a large, multidimensional dataset of results from quality control analyses of uranium ore concentrate (UOC, sometimes called 'yellowcake'). We have found that traditional multidimensional techniques, such as principal components analysis (PCA), are especially useful for understanding such datasets and drawing relevant conclusions. In particular, we have developed an iterative partial least squares-discriminant analysis (PLS-DA) procedure that has proven especially adept at identifying the production location of unknown UOC samples. By removing classes which fell far outside the initial decision boundary, and then rebuilding the PLS-DA model, we have consistently produced better and more definitive attributions than with a single pass classification approach. Performance of the iterative PLS-DA method compared favorably to that of classification and regression tree (CART) and k nearest neighbor (KNN) algorithms, with the best combination of accuracy and robustness, as tested by classifying samples measured independently in our laboratories against the vendor QC based reference set.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration and Uncertainty Estimation Using the Ensemble Kalman Filter with a Large Subsurface Flow and Transport Model - 20321

At routinely monitored groundwater contamination sites, periodically measured environmental conditions such as groundwater levels and contaminant concentrations are used to inform and confirm a conceptual site model (CSM) and guide the development and calibration of a numerical groundwater flow and transport model. The calibration of groundwater flow and transport models after each measurement (sampling) event can illuminate deficiencies in a CSM, identify areas where additional monitoring is warranted, and predict the behavior of the system to guide decision making. However, manual and automated (e.g. PEST) model calibration tools can be time-consuming and computationally expensive to implement after each sampling event. Perhaps as a result, such calibration tools generally utilize all available monitoring data simultaneously rather than sequentially assimilating monitoring data one sampling event at a time as the results from sampling become available. A more real-time data assimilation approach may reduce parameter uncertainty, quantify the value of additional monitoring data, and produce a usable model more quickly and with less effort. To mitigate the potential time-consuming aspects of manual and widely applied automated calibration techniques, a data assimilation algorithm called the ensemble Kalman filter (EnKF) was evaluated as a relatively efficient method of model calibration and uncertainty assessment via the sequential integration of monitoring data into a model. The EnKF was able to successfully and efficiently assimilate monitoring and modeling data to calibrate a complex flow and transport model at a real-world site with significant subsurface heterogeneity, uncertainty, and 12 years of monitoring data (over 4,000 individual measurements of groundwater levels and over 2,500 measurements of contaminant concentrations). Starting with an uncalibrated model data from annual sampling events were sequentially assimilated, and the resultant predication errors and estimated parameter uncertainties were tracked. After all monitoring data were assimilated, both flow and transport residuals at the end of the EnKF process were comparable to those produced via a concurrent PEST calibration effort but required fewer model simulations. Both uncertainty and prediction errors decreased over time. In a real-time application, the adequacy of the model could be assessed after each sampling event. The benefits of such a real-time approach to utilizing monitoring data include reduced costs (in the form of model updates or site characterization efforts), early flagging of possible errors in the CSM, and a reduced risk of overfitting and corresponding increased confidence in model predictions. This tool may be particularly useful compared to other calibration techniques (e.g. manual, PEST) when model runtimes are long, calibration parameters are many, or parameter uncertainty is large. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗