Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Radiation-induced negative optical nonlinearities in fused silica, sapphire, and borosilicate glass

Here, negative nonlinear absorption is reported in neutron- and gamma-irradiated high-OH content fused silica, low-OH content fused silica, sapphire, borosilicate glass, and radiation-resistant borosilicate glass irradiated to total neutron fluences of 3.4 × 10 16 n ∙ cm –2 (42 Mrad γ), 1.7 × 10 17 n ∙ cm –2 (211 Mrad γ), and 3.6 × 10 17 n ∙ cm –2 (433 Mrad γ). Nonlinear absorption coefficients were measured via Z-scan and are on the order of – (10 –14 –10 –10 ) m∙W –1 . The Z-scan also reveals a negative nonlinear index of refraction in neutron- and gamma-irradiated radiation-resistant borosilicate glass on the order of –10 –19 m 2 ∙ W –1 . Thermal annealing at temperatures up to 800 °C is shown to restore these nonlinearities to their positive unirradiated values in all four materials. All Z-scan measurements were performed at 532 nm with a nanosecond pulsed laser. The occurrence of negative nonlinearities may be attributed to the presence of metallic impurities and the resulting saturable absorption. A limited effect of photobleaching is observed in measurements and is quantified in multiple Z-scans.

36 MATERIALS SCIENCE↗

Origins of radiation-induced optical attenuation in neutron-irradiated single-crystal sapphire at elevated temperatures

Sapphire (α-Al 2 O 3 ) is a candidate fiber-optic sensor material for extreme temperature environments, potentially including those of nuclear reactors. However, its optical transmission under high-dose neutron irradiation is not well understood compared with that of conventional fused silica. This study examined dimensional changes, optical transmission, and irradiation-induced defects in neutron-irradiated α-Al 2 O 3 at temperatures of 298 °C to 688 °C and doses of 3.2 to 12 dpa. Although previous studies attributed radiation-induced attenuation (RIA) at the highest irradiation temperatures to increased optical scattering from radiation-induced voids, our findings indicate that scattering from neither voids nor dislocation loops can explain the measured attenuation. Instead, absorption due to aluminum vacancy centers appears more likely based on a comparison of the spectral features of the measured optical attenuation with previous literature. Significant c-axis swelling (5.51 % ± 0.83 %) was observed in the 12 dpa, 592 °C irradiated sample, much higher than earlier measurements, suggesting temperature sensor drift of 543 °C to 1,140 °C. Void patterning was predominantly observed along the a-axis, differing from previous studies on polycrystalline samples, which showed c-axis patterning. Dislocation loops evolved into network dislocations with increasing temperature and dose; voids formed within these structures, showing no size or density changes, indicating an atypical growth mechanism.

Neutron irradiation↗

The diurnally-averaged aerosol direct radiative effect and the use of the daytime-mean and insolation-weighted-mean solar zenith angles

Here, this study examines the application of the daytime-mean and insolation-weighted-mean solar zenith angles to calculate the diurnally-averaged aerosol direct radiative effect (DRE), DRE DA , for observed clear-sky conditions at the Atmospheric Radiation Measurement Program (ARM) Southern Great Plains (SGP) and Tropical Western Pacific (TWP) sites. As compared with the reference calculation, the DRE DA are too strong (i.e., more negative) using daytime-mean solar zenith angles (DTMSZA) and are too weak (i.e., less negative) using insolation-weighted-mean solar zenith angles (IWMSZA). The biases in the DRE DA for DTMSZA (IWMSZA) are about -0.8 (0.7) W m -2 at the TOA and about -1.5 (0.9) W m -2 at the surface. Noting the mean TOA DRE DA of -2.85 W m -2 and the surface DRE DA of -7.09 W m -2 at SGP, the relative biases for DTMSZA (IWMSZA) are 26% (-24%) for the TOA DRE DA , and 17% (-11%) for the surface DRE DA . At TWP, the mean TOA DRE DA is -2.81 W m -2 and the surface DRE DA is -11.84 W m -2 which corresponds to relative biases for DTMSZA (IWMSZA) of 29% (-27%) for the TOA DRE DA and 15% (-9%) for the surface DRE DA . By introducing an adjusted insolation-weighted-mean solar zenith angle, the mean biases in the DRE DA at the TOA becomes -0.09 W m -2 and the biases in the DRE DA at the surface are about -0.41 W m -2 . Also presented are the effects of using the mean solar zenith angles on the shortwave (SW) upward fluxes at the TOA and SW downward fluxes at the surface in both clear-sky and pristine-clear-sky (i.e., gases only) conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Copper-nickel electroplating of 3D-printed acrylonitrile butadiene styrene for interference and radiation shielding applications

Here, in this study, electromagnetic and radiation shielding structures were fabricated by 3D printing acrylonitrile butadiene styrene (ABS) structures via fused filament fabrication and electroplating with copper (Cu) and nickel (Ni) metals. Prior to electroplating, the printed ABS materials were made conductive by surface electrodeposition of polypyrrole (PPy). ABS adsorbs the pyrrole monomer, which subsequently polymerizes via oxidation forming conductive PPy layer on the printed structures. The successful anchoring of PPy layer can be attributed to its hydrogen bonding and electrostatic interactions with ABS. Thermal analysis, optical, and electron microscopy equipped with energy dispersive X-ray were employed to characterize the printed shielding structures, while the interference and radiation shielding effectiveness were evaluated using a spectrum analyzer and dosimeter, respectively. The interference shielding was found to be effective at 60 ± 5 dB over relatively small frequency range. Shielding was also apparent against gamma and X-ray ionizing rays, but more significantly effective against beta rays. Furthermore, the Cu/Ni coating was able to reduce any heat-induced dimensional changes for the 3D printed ABS substrate without compromising the mechanical integrity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical spectroscopy of molten fluorides: Methods, electronic and vibrational data, structural interpretation, and relevance to radiative heat transfer

In this study, to help address the need for predicting radiative heat transfer (RHT) behavior of molten salts, we conducted a comprehensive review of methods and data from optical spectroscopic measurements on molten fluoride salts. Transmittance, reflectance, and trans-reflectance experimental methods are discussed, along with the corresponding data reduction methodology and the limitations of each technique. Optical spectroscopy is a convenient indirect probe for changes in structural parameters with temperature and composition. Electronic and vibrational absorption data for transition-metal, lanthanide, and actinide solutes and vibrational absorption data for alkali and alkaline earth fluoride solvents are compiled, and the corresponding structural interpretation is discussed and compared with other experimental and theoretical work. We find that solvent and solute vibrational absorption can be significant in the mid-infrared, resulting in near-infrared edges of significance to RHT. Extrapolation and averaging of existing edge data leads to estimated gray absorption coefficient values at 700 °C of 546 m —1 for FLiBe and 276 m —1 for FLiNaK, both within the range of 1 – 6000 m —1 identified to be of engineering relevance for radiative heat transfer analysis.

36 MATERIALS SCIENCE↗

Radiation shielding analysis of the concrete hutch of a long beamline of the Advanced Photon Source Upgrade project

The radiation shielding analysis of the external concrete enclosure of a feature long beamline of the Advanced Photon Source Upgrade project is described in this work. The beamline has 2 undulators that can operate in two different configurations and the source terms are estimated for the worst configuration using the SRW code in the OASYS package as well as the STAC8 code. The shielding analysis is carried out using the STAC8 code, and for the case of pink beam, with the FLUKA code also. Effective dose rates on contact with the outside surface of the concrete walls for pink, reflected full spectrum and monochromatic beams are calculated. For the monochromatic beams, 2 sets of discrete bandwidths (BW) from the Double Crystal Monochromator (DCM) and the full reflectance of the Double Multilayer Monochromator (DMM) are used. Further, due to the size of the direct beam and the energy domain of interest in the direct and scattered fields, the importance of the equivalent dose to the lens of the eye is discussed with respect to the shielding calculations of such facilities. The dose rates outside the concrete hutch in the lateral directions calculated using STAC8 is about 50% higher than the FLUKA results for the case of pink beam but may be considered as a reasonable agreement due to the differences in the calculational methodologies. Those dose rates in the lateral and forward directions are higher for the pink beam to allow full occupancy from the radiation protection point of view. For the full spectrum after 3 reflections, the effective dose rates are less than 0.5 Sv/h in the lateral direction but is higher in the forward region below about 22° with respect to the beam direction. For the DCM beams, except for the scenario with one mirror and 0.1%BW, all dose rates are less than 0.5 Sv/h outside the concrete hutch in the lateral directions. Here, the higher harmonics are what contributes to the dose outside the shield and the bandwidths assumed to derive the photon flux thus becomes important. The dose rates with the DMM are generally lower compared to the 0.1% BW DCM beam but are higher than the results obtained with XOP calculated bandwidths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of natural gamma background radiation on portal monitor radioisotope unmixing

It is well known that national security relies on several layers of protection. One of the most important is the traffic control at borders and ports that exploits Radiation Portal Monitors (RPMs) to detect and deter potential smuggling attempts. Most portal monitors rely on plastic scintillators to detect gamma rays. Despite their poor energy resolution, their cost effectiveness and the possibility of growing them in large sizes make them the gamma-ray detector of choice in RPMs. Unmixing algorithms applied to organic scintillator spectra can be used to reliably identify the bare and unshielded radionuclides that triggered an alarm, even with fewer than 1000 detected counts and in the presence of two or three nuclides at the same time. In this work, we experimentally studied the robustness of a state-of-the-art unmixing algorithm to different radiation background spectra, due to varying atmospheric conditions, in the 16 °C to 28 °C temperature range. In the presence of background, the algorithm is able to identify the nuclides present in unknown radionuclide mixtures of three nuclides, when at least 1000 counts from the sources are detected. With fewer counts available, we found larger differences of approximately 35.9% between estimated nuclide fractions and actual ones. In these low count rate regimes, the uncertainty associated by our algorithm with the identified fractions could be an additional valuable tool to determine whether the identification is reliable or a longer measurement to increase the signal-to-noise ratio is needed. Moreover, the algorithm identification performances are consistent throughout different data sets, with negligible differences in the presence of background types of different intensity and spectral shape.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Demonstrating the β-Ga 2 O 3 Schottky diodes for alpha radiation detection

Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A machine learning framework for accurate and robust analysis of radiation detector pulses

The microscopic properties of atomic nuclei are used to study various scientific questions. They are essential for understanding the fundamental forces of nature and the chemical evolution of the universe. Detecting decay radiation from radioactive nuclei makes it possible to probe these fundamental nuclear properties. Detector waveform traces may contain additional information about the radiation. Generally, advanced signal processing techniques are needed to extract this additional information, often involving fitting the waveform with model response functions using non-linear least-squares optimization with second-order gradient methods. While this is a powerful technique, it is also computationally expensive, leading to slow processing time, which scales with the volume of data. To address this problem, we have developed a machine learning (ML) approach that infers the characteristics of traces from a model detector response function. In particular, we are interested in classifying whether a single recorded trace consists of one or two pulse constituents and estimating the pulse parameters. Furthermore, our proposed ML method can precisely extract the pulses’ parameters, such as energy and timing information, and accurately classify the pulse multiplicity of a trace. Unlike non-learning-based approaches, our ML approach uses neural networks that are significantly faster at inference, as they do not require any optimization during this stage.

Curve fitting↗

Bound states and electromagnetic radiation of relativistically rotating cylindrical wells

Here, we compute the effect of rigid rotation on the non-relativistic bound states. The energy levels of the bound states increase with the angular velocity of rotation until at certain value of the angular velocity they are completely pushed out into the continuum which corresponds to dissociation of the bound states. When the angular velocity exceeds the critical value at which the ground state disappears into the continuum, no bound state is possible. This effect should have important consequences for the phenomenology of the quark-gluon plasma. One of the ways to study it experimentally is to observe the electromagnetic radiation emitted by a rotating bound state. We compute the corresponding intensity of electromagnetic radiation and show that it strongly depends on the angular velocity of rotation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stopping to reflect: Asymptotic static moving mirrors as quantum analogs of classical radiation

Radiation from an accelerating charge is a basic process that can serve as an intersection between classical and quantum physics. We present two exactly soluble electron trajectories that permit analysis of the radiation emitted, exploring its time evolution and spectrum by analogy with the moving mirror model of the dynamic Casimir effect. These classical solutions are finite energy, rectilinear (nonperiodic), asymptotically zero velocity worldlines with corresponding quantum analog beta Bogolyubov coefficients. One of them has an interesting connection to uniform acceleration and Leonardo da Vinci's water pitcher experiment.

79 ASTRONOMY AND ASTROPHYSICS↗

Nitrogen effects on radiation response in 12Cr ferritic/martensitic alloys

Ferritic/martensitic steels are one of the best candidates for structural materials for high dose applications in next generation nuclear reactors. The composition of structural materials must be optimized for reliable service during irradiation. This study reports the effect of interstitial nitrogen on radiation response in 12Cr ferritic/martensitic HT9 steels having a controlled nitrogen concentration. Results show that a high amount of ‘free’ nitrogen in the matrix stabilizes the interstitial clusters which leads to (i) larger loop sizes (ii) lower loop density and (iii) slightly reduced radiation induced hardening. It also affects diffusion mechanism of Ni and formation of Ni/Si-rich precipitates.

36 MATERIALS SCIENCE↗

Application of multi-method-multi-model inference to radiation related solid cancer excess risks models for astronaut risk assessment

The impact of including model-averaged excess radiation risks (ER) into a measure of radiation attributed decrease of survival (RADS) for the outcome all solid cancer incidence and the impact on the uncertainties is demonstrated. It is shown that RADS applying weighted model averaged ER based on AIC weights result in smaller risk estimates with narrower 95% CI than RADS using ER based on BIC weights. Further a multi-method-multi-model inference approach is introduced that allows calculating one general RADS estimate providing a weighted average risk estimate for a lunar and a Mars mission. For males the general RADS estimate is found to be 0.42% (95% CI: 0.38%; 0.45%) and for females 0.67% (95% CI: 0.59%; 0.75%) for a lunar mission and 2.45% (95% CI: 2.23%; 2.67%) for males and 3.91% (95% CI: 3.44%; 4.39%) for females for a Mars mission considering an age at exposure of 40 years and an attained age of 65 years. It is recommended to include these types of uncertainties and to include model-averaged excess risks in astronaut risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Bayesian framework to investigate radiation reaction in strong fields

Recent experiments aiming to measure phenomena predicted by strong-field quantum electrodynamics (SFQED) have done so by colliding relativistic electron beams and high-power lasers. In such experiments, measurements of collision parameters are not always feasible. However, precise knowledge of these parameters is required to accurately test SFQED. Here, we present a novel Bayesian inference procedure that infers collision parameters that could not be measured on-shot. This procedure is applicable to all-optical non-linear Compton scattering experiments investigating radiation reaction. The framework allows multiple diagnostics to be combined self-consistently and facilitates the inclusion of known information pertaining to the collision parameters. Using this Bayesian analysis, the relative validity of the classical, quantum-continuous and quantum-stochastic models of radiation reaction was compared for several test cases, which demonstrates the accuracy and model selection capability of the framework and highlight its robustness if the experimental values of fixed parameters differ from their values in the models.

47 OTHER INSTRUMENTATION↗

Radiation Effects on the Performance of Advanced Sulfur Monochloride Chlorination Processes

Advanced sulfur chloride-based chlorination technologies are being developed to enable efficient recycling of aluminum and zirconium-based materials used in the nuclear industry. However, the impacts of ionizing radiation on the performance of these sulfur chloride compounds are not well established, despite this being critical knowledge for assessing their feasibility and longevity under envisioned process conditions. Here, in the present article, we report on the effects of cobalt-60 gamma irradiation (≤ 5 MGy) on the aluminum alloy 6061 (AA6061-T6) chlorination yield in sulfur monochloride (S 2 Cl 2 ). Our findings indicate that, compared to nonirradiated solvent, radiation-induced changes in the chemical composition of S 2 Cl 2 —identified using Raman spectroscopy—afford an additional, dose-dependent exothermic process prior to the chlorination reaction’s typical thermodynamic behavior. We attribute this new process to reactions involving aluminum species (metal, oxide, or [oxy]hydroxides) and sulfur dichloride (SCl 2 ), an S 2 Cl 2 radiolysis product that accumulates with absorbed gamma dose, but is absent following an AA6061-T6 chlorination study. Despite the exothermicity of this new process, the overall yield of chlorination decreased with increasing preirradiation dose. Consequently, the chemical reactivity, specificity (aluminum metal vs aluminum passivation and corrosion layer constituents), and byproducts of SCl 2 must be more thoroughly evaluated to support the continued development of advanced S 2 Cl 2 chlorination technologies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Chemical Kinetics for the Oxidation of Californium(III) Ions with Select Radiation-Induced Inorganic Radicals (Cl 2 •– and SO 4 •– )

Despite the availability of transuranic elements increasing in recent years, our understanding of their most basic and inherent radiation chemistry is limited and yet essential for accurate interpretation of their physical and chemical properties. Here, in this work, we explore the transient interactions between trivalent californium ions (Cf 3+ ) and select inorganic radicals arising from the radiolytic decomposition of common anions and functional group constituents, specifically the dichlorine (Cl 2 •- ) and sulfate (SO 4 •- ) radical anions. Chemical kinetics, as measured by integrated electron pulse radiolysis and transient absorption spectroscopy techniques, are presented for the reactions of these two oxidizing radicals with Cf 3+ ions. The derived and ionic strength corrected second-order rate coefficients (k) for these radiation-induced processes are k(Cf 3+ + Cl 2 •- ) = (8.28 ± 0.61) × 10 5 M -1 s -1 and k(Cf 3+ + SO 4 •- ) = (9.50 ± 0.43) × 10 8 M -1 s -1 under ambient temperature conditions (22 ± 1 °C).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamics of Radiation Damage Buildup in Ultrathin Hexagonal Boron Nitride Films under Ion Bombardment

Two-dimensional hexagonal boron nitride (hBN) is attractive for several emerging applications. Ion bombardment can be used to modify the hBN properties. However, the understanding of radiation damage buildup in hBN remains limited. Here, we investigate the effects of the dose rate and ion mass on radiation damage buildup by studying 40 nm-thick hBN films bombarded at room temperature with 500 keV 4 He, 15 N, 40 Ar, and 129 Xe ions and comparing with results for ion bombardment of polycrystalline hBN ceramics. Raman spectroscopy is used to quantify damage buildup, and transmission electron microscopy is used for microstructural analysis. Experiments are complemented by molecular dynamics simulations of the formation and evolution of point defects. Lighter ions are found to be more efficient at disordering hBN than heavier ions. This observation points to a critical role of intracascade defect processes. In contrast, a negligible dose rate effect observed suggests limited intercascade defect dynamic annealing processes for these irradiation conditions. These findings provide a fundamental basis for hBN defect engineering.

2D materials↗

Clouds and Convective Self-Aggregation in a Multimodel Ensemble of Radiative-Convective Equilibrium Simulations

The Radiative-Convective Equilibrium Model Intercomparison Project (RCEMIP) is an intercomparison of multiple types of numerical models configured in radiative-convective equilibrium (RCE). RCE is an idealization of the tropical atmosphere that has long been used to study basic questions in climate science. Here, we employ RCE to investigate the role that clouds and convective activity play in determining cloud feedbacks, climate sensitivity, the state of convective aggregation, and the equilibrium climate. RCEMIP is unique among intercomparisons in its inclusion of a wide range of model types, including atmospheric general circulation models (GCMs), single column models (SCMs), cloud-resolving models (CRMs), large eddy simulations (LES), and global cloud-resolving models (GCRMs). The first results are presented from the RCEMIP ensemble of more than 30 models. While there are large differences across the RCEMIP ensemble in the representation of mean profiles of temperature, humidity, and cloudiness, in a majority of models anvil clouds rise, warm, and decrease in area coverage in response to an increase in sea surface temperature (SST). Nearly all models exhibit self-aggregation in large domains and agree that self-aggregation acts to dry and warm the troposphere, reduce high cloudiness, and increase cooling to space. The degree of self-aggregation exhibits no clear tendency with warming. There is a wide range of climate sensitivities, but models with parameterized convection tend to have lower climate sensitivities than models with explicit convection. In models with parameterized convection, aggregated simulations have lower climate sensitivities than unaggregated simulations.

54 ENVIRONMENTAL SCIENCES↗