Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A tilted pulse-front setup for femtosecond transient grating spectroscopy in highly non-collinear geometries

We demonstrate a tilted pulse-front transient grating (TG) technique that allows to optimally utilize time resolution as well as TG line density while probing under grazing incidence as typically done in extreme ultraviolet (EUV) or soft x-ray (SXR) experiments. Our optical setup adapts the pulse front tilt of the two pulses that create the TG to the grazing incident pulse. Here, we demonstrate the technique using all 800 nm femtosecond laser pulses for TG generation on a vanadium dioxide film. We probe that grating via diffraction of a third 800 nm pulse. The time resolution of 90 fs is an improvement by a factor of 30 compared to our previous experiments on the same system. Lastly, the scheme paves the way for EUV and SXR probing of optically induced TGs on any material.

36 MATERIALS SCIENCE↗

Shaping attosecond pulses by controlling the minima in high-order harmonic generation through alignment of CO 2 molecules

In this paper, we report a simple method for generating shaped attosecond pulses by using a CO 2 molecule. Unlike most other molecules, owing to its unique energy and angle dependence and the presence of deep minima in the photoionization transition dipole moment, the shape of harmonic spectra, especially the position and depth of minima, can be readily controlled by tuning the degree of alignment. The sensitive alignment dependence of the minima is due to the coherent interference of a laser-induced dipole from each molecule when CO 2 molecules are moderately aligned, but not when they are well aligned or when they are isotropically distributed. Such a sensitivity offers a simple way of controlling the spectral amplitude and phase of the generated harmonics and thus shaping the generated attosecond pulses, for example, producing structured attosecond pulses by splitting a single burst into two. We illustrate how such pulses are generated and how to characterize them. This method offers a simple way to shape attosecond pulses at the generation step. It can be easily implemented experimentally to generate attosecond pulses with strong phase variations for unique applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Pathways to excitation of atoms with bicircular laser pulses

We study the excitation of the hydrogen atom by bichromatic circularly polarized laser pulses using numerical solutions of the time-dependent Schrödinger equation. The results are in agreement with the selection rules for multiphoton processes in such fields, namely, excited states are populated in which orbital angular momentum and magnetic quantum numbers are either both odd or both even, independent of the relative helicity, peak intensity, and pulse duration of the pulses. For co-rotating pulses the results show that excitation predominantly proceeds to states with magnetic quantum number of the same helicity as the laser pulses. Besides pathways via direct photon absorption from the ground state our results indicate that a transfer of population among the Rydberg states occurs via Λ-type transitions. In the case of counter-rotating pulses the largest excitation probability is found for Rydberg states that differ in magnetic quantum number by Δm=±3. This pattern allows us to estimate how many photons from each of the two bichromatic fields have been absorbed. Finally, we confirm that a population in Rydberg states beyond a maximum orbital angular quantum number is unlikely.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of attosecond electron dynamics in the photoelectron momentum distribution of atoms using few-cycle laser pulses

The method of time-resolved measurement with ultrashort laser pulses is vital to the development of attosecond science. Pump-probe measurements using a train of attosecond pulses in combination with a near-infrared (NIR) multicycle driving laser have been successful in capturing the intercycle electron dynamics which repeats every optical cycle and leads to above-threshold ionization (ATI) spectra in the frequency domain. Here in this work, we study the effect of a carrier-envelope phase (CEP) in a few-cycle (< 6 fs) NIR laser pulse on the photoelectron momentum distribution (PMD) of a hydrogen atom and show that interference patterns in a PMD change dramatically with CEPs in the few-cycle regime. When the few-cycle driving laser pulse has a sine shape, the double-slit interference with characteristic modulation of ATI peaks dominates the PMD. On the other hand, when the driving pulse has a cosine shape, the holographical interference featured by a spider-like pattern is isolated. Our results suggest that the CEP-stable few-cycle laser pulses can be used to identify different types of intracycle interference structures in a PMD which reveal the underlying subcycle electron dynamics on an attosecond timescale.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser pulse-length dependent ablation and shock generation in silicon at 5 × 10 14 W/ cm 2 intensities

The effect of laser pulse duration on energy coupling into a planar silicon target is investigated in experiments at the OMEGA-EP facility by varying the laser pulse length τ —spanning 3 orders of magnitude from 100 ps to 10 ns—while maintaining a constant peak laser intensity, I 0 = 5 × 10 14 W/ cm 2 . In theoretical models, the ablation pressure primarily scales for a given material with laser intensity and wavelength, which are all fixed variables here, allowing us to explore the specific role of laser pulse duration. Two-dimensional radiation-hydrodynamics simulations benchmarked with optical probing of the expanding plasma show that the pulse duration is critical for the ablation pressure to reach a steady state. Moreover, the pulse duration impacts shock decay and multiple wave effects, which strongly dictate the evolving shock profile that propagates within the laser-shocked target as ultimately measured by rear-surface diagnostics. The shock velocities inferred from the theoretical model, after considering shock decay, impedance matching, and shock Hugoniot, are found to be in good agreement with velocimetry measurements. However, discrepancies are observed with simulations for the shorter (0.1 ns) and longer (10 ns) pulse durations, which are respectively attributed to unaccounted contributions of kinetic absorption mechanisms and instabilities in simulations. Published by the American Physical Society 2024

Bailly-Grandvaux, M. (ORCID:0000000175294013)↗

Pulse Duration of Seeded Free-Electron Lasers

The pulse duration, and, more generally, the temporal intensity profile of free-electron laser (FEL) pulses, is of utmost importance for exploring the new perspectives offered by FELs; it is a nontrivial experimental parameter that needs to be characterized. We measured the pulse shape of an extreme ultraviolet externally seeded FEL operating in high-gain harmonic generation mode. Two different methods based on the cross-correlation of the FEL pulses with an external optical laser were used. The two methods, one capable of single-shot performance, may both be implemented as online diagnostics in FEL facilities. The measurements were carried out at the seeded FEL facility FERMI. The FEL temporal pulse characteristics were measured and studied in a range of FEL wavelengths and machine settings, and they were compared to the predictions of a theoretical model. Finally, the measurements allowed a direct observation of the pulse lengthening and splitting at saturation, in agreement with the proposed theory.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectral splitting of optical pulses inside a dispersive medium at a temporal boundary

We show numerically that the spectrum of an optical pulse splits into multiple, widely separated, spectral bands when it arrives at a temporal boundary across which refractive index changes suddenly. At the same time, the pulse breaks into several temporally separated pulses traveling at different speeds. The number of such pulses depends on the dispersive properties of the medium. We study the effect of second- and third-order dispersion in detail but also consider briefly the impact of other higher-order terms. As a result, a temporal waveguide formed with two temporal boundaries can reflect the temporally separated pulses again and again, increasing the number of pulses trapped within the temporal waveguide.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulse-Shape Analysis of Neutron-Induced Scintillation Light in Ni-doped 6LiF/ZnS

Abstract–Alternatives to 3He are being investigated for gamma-ray insensitive neutron detection applications, including plutonium assay. One promising material is lithium-6 fluoride with silver activated zinc sulfide 6LiF/ZnS(Ag) in conjunction with a wavelength shifting plastic. Doping the 6LiF/ZnS(Ag) with nickel (Ni) has been proposed as a means of reducing the decay time of neutron signal pulses. This research performed a pulse shape comparison between Ni-doped and non-doped 6LiF/ZnS(Ag) neutron pulses. The Ni-doped 6LiF/ZnS(Ag) had a 32.7% ± 0.3 increase in neutron pulse height and a 32.4% ± 0.3 decrease in neutron pulse time compared to the non-doped 6LiF/ZnS(Ag). Doping 6LiF/ZnS(Ag) with nickel may allow neutron detector operation with improved signal to noise ratios, and reduced pulse pileup affects, increasing the accuracy and range of source activities with which such a detector could operate.

Cowles, Christian C.↗

Accelerating protons to therapeutic energies with ultraintense, ultraclean, and ultrashort laser pulses

Proton acceleration by high-intensity laser pulses from ultrathin foils for hadron therapy is discussed. With the improvement of the laser intensity contrast ratio to 10{sup -11} achieved on the Hercules laser at the University of Michigan, it became possible to attain laser-solid interactions at intensities up to 10{sup 22} W/cm{sup 2} that allows an efficient regime of laser-driven ion acceleration from submicron foils. Particle-in-cell (PIC) computer simulations of proton acceleration in the directed Coulomb explosion regime from ultrathin double-layer (heavy ions/light ions) foils of different thicknesses were performed under the anticipated experimental conditions for the Hercules laser with pulse energies from 3 to 15 J, pulse duration of 30 fs at full width half maximum (FWHM), focused to a spot size of 0.8 {mu}m (FWHM). In this regime heavy ions expand predominantly in the direction of laser pulse propagation enhancing the longitudinal charge separation electric field that accelerates light ions. The dependence of the maximum proton energy on the foil thickness has been found and the laser pulse characteristics have been matched with the thickness of the target to ensure the most efficient acceleration. Moreover, the proton spectrum demonstrates a peaked structure at high energies, which is required for radiation therapy. Two-dimensional PIC simulations show that a 150-500 TW laser pulse is able to accelerate protons up to 100-220 MeV energies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-112: Clinical Feasibility Test of An RF Pulse-Based MRI Method for the Quantitative Fat-Water Segmentation

Purpose: Quantitative fat-water segmentation is important not only because of the clinical utility of fat-suppressed MRI images in better detecting lesions of clinical significance (in the midst of bright fat signal) but also because of the possible physical need, in which CT-like images based on the materials’ photon attenuation properties may have to be generated from MR images; particularly, as in the case of MR-only radiation oncology environment to obtain radiation dose calculation or as in the case of hybrid PET/MR modality to obtain attenuation correction map for the quantitative PET reconstruction. The majority of such fat-water quantitative segmentations have been performed by utilizing the Dixon’s method and its variations, which have to enforce the proper settings (often predefined) of echo time (TE) in the pulse sequences. Therefore, such methods have been unable to be directly combined with those ultrashort TE (UTE) sequences that, taking the advantage of very low TE values (∼ 10’s microsecond), might be beneficial to directly detect bones. Recently, an RF pulse-based method (http://dx.doi.org/10.1016/j.mri.2015.11.006), termed as PROD pulse method, was introduced as a method of quantitative fat-water segmentation that does not have to depend on predefined TE settings. Here, the clinical feasibility of this method is verified in brain tumor patients by combining the PROD pulse with several sequences. Methods: In a clinical 3T MRI, the PROD pulse was combined with turbo spin echo (e.g. TR=1500, TE=16 or 60, ETL=15) or turbo field echo (e.g. TR=5.6, TE=2.8, ETL=12) sequences without specifying TE values. Results: The fat-water segmentation was possible without having to set specific TE values. Conclusion: The PROD pulse method is clinically feasible. Although not yet combined with UTE sequences in our laboratory, the method is potentially compatible with UTE sequences, and thus, might be useful to directly segment fat, water, bone and air.

60 APPLIED LIFE SCIENCES↗

Impact of the optical parametric amplification phase on laser pulse compression

Optical parametric chirped-pulse amplification (OPCPA) is an effective way to generate ultrashort pulses that has been used extensively for a variety of applications requiring high peak intensities. Precise control and measurement of a system’s spectral and spatial phases are required for Fourier transform–limited pulse compression and diffraction-limited focusing. Phase accumulated during optical parametric amplification (OPA) can degrade the compressibility and focusability of the pulse, reducing peak intensity. We used analytic and numerical analysis of OPA to study the influence of crystal parameters, wavefront of the pump and signal, and their relative optical alignment on the accumulated phase. Here, we show that the accumulated signal phase is largely independent of amplifier saturation and, with significant local wavefront gradients in the signal or pump beam, the quality of the compressed pulses can be degraded. We use first-order expressions for the pump- and signal-angle sensitivity to evaluate an OPCPA system consisting of a highly deuterated potassium dihydrogen phosphate (DKDP) amplifier designed to support bandwidth for 15 fs pulses centered at 920 nm.

47 OTHER INSTRUMENTATION↗

High-Dynamic-Range Single-Shot Cross-Correlator Based on an Optical Pulse Replicator

The operation of a single-shot cross-correlator based on a pulse replicator is described. The correlator uses a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test. The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm. A dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps.

ultrafast measurements↗

Interaction of short x-ray pulses with low-Z x-ray optics materials at the LCLS free-electron laser

Materials used for hard x-ray-free-electron laser (XFEL) optics must withstand high-intensity x-ray pulses. The advent of the Linac Coherent Light Source has enabled us to expose candidate optical materials, such as bulk B 4 C and SiC films, to 0.83 keV XFEL pulses with pulse energies between 1 μJ and 2 mJ to determine short-pulse hard x-ray damage thresholds. The fluence required for the onset of damage for single pulses is around the melt fluence and slightly lower for multiple pulses. We observed strong mechanical cracking in the materials, which may be due to the larger penetration depths of the hard x-rays.

36 MATERIALS SCIENCE↗

The role of defects in laser-induced modifications of silica coatings and fused silica using picosecond pulses at 1053 nm: I Damage morphology

Laser-induced damage with ps pulse widths straddles the transition from intrinsic, multi-photon ionization and avalanche ionization-based ablation with fs pulses to defect-dominated, thermal-based damage with ns pulses. We investigated the morphology of damage for fused silica and silica coatings between 1 ps and 60 ps at 1053 nm. Using calibrated laser-induced damage experiments, in situ imaging, and high-resolution optical microscopy, atomic force microscopy, and scanning electron microscopy, we show that defects play an important role in laser-induced damage down to 1 ps. Three types of damage are observed: ablation craters, ultra-high density pits, and smooth, circular depressions with central pits. For 10 ps and longer, the smooth, circular depressions limit the damage performance of fused silica and silica coatings. The observed high-density pits and material removal down to 3 ps indicate that variations in surface properties limit the laser-induced damage onset to a greater extent than expected below 60 ps. Below 3 ps, damage craters are smoother although there is still evidence as seen by AFM of inhomogeneous laser-induced damage response very near the damage onset. These results show that modeling the damage onset only as a function of pulse width does not capture the convoluted processes leading to laser induced damage with ps pulses. It is necessary to account for the effects of defects on the processes leading to laser-induced damage. In conclusion, the effects of isolated defects or inhomogeneities are most pronounced above 3 ps but are still discernible and possibly important down to the shortest pulse width investigated here.

42 ENGINEERING↗

Octave-spanning mid-infrared femtosecond OPA in a ZnGeP 2 pumped by a 2.4 μm Cr:ZnSe chirped-pulse amplifier

We report on the highly efficient, octave-spanning mid-infrared (mid-IR) optical parametric amplification (OPA) in a ZnGeP 2 (ZGP) crystal, pumped by a 1 kHz, 2.4 μm, 250 fs Cr:ZnSe chirped-pulse amplifier. The full spectral coverage of 3−10 μm with the amplified signal and idler beams is demonstrated. The signal beam in the range of ∼3 − 5 μm is produced by either white light generation (WLG) in YAG or optical parametric generation (OPG) in ZGP using the common 2.4 μm pump laser. We demonstrate the pump to signal and idler combined conversion efficiency of 23% and the pulse energy of up to 130 μJ with ∼2 μJ OPG seeding, while we obtain the efficiency of 10% and the pulse energy of 55 μJ with ∼0.2 μJ WLG seeding. The OPA output energy is limited by the available pump pulse energy (0.55 mJ at ZGP crystal) and therefore further energy scaling is feasible with multi-stage OPA and higher pump pulse energy. The autocorrelation measurements based on random quasi-phase matching show that the signal pulse durations are ∼318 fs and ∼330 fs with WLG and OPG seeding, respectively. In addition, we show the spectrally filtered 30 μJ OPA output at 4.15 μm suitable for seeding a Fe:ZnSe amplifier. Our ultrabroadband femtosecond mid-IR source is attractive for various applications, such as strong-field interactions, dielectric laser electron acceleration, molecular spectroscopy, and medical surgery.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optics-on-a-chip for ultrafast manipulation of 350-MHz hard x-ray pulses

Microelectromechanical systems (MEMS) are miniature devices integrated into a vast range of industrial and consumer applications. Optical MEMS are developed for dynamic spatiotemporal control in lightwave manipulation and communication as modulators, switches, multiplexers, spectrometer, etc. However, they have not been shown to function similarly in sub-nm wavelength regimes, namely, with hard x-rays, as high-brilliance pulsed x-rays have proven powerful for addressing challenges in time-domain science, from energy conversion to neurobiological control. While desirable temporal properties of x-ray pulses can be enhanced by optics, conventional x-ray optics are inherently massive in size, hence, never dynamic. We demonstrate highly ultrafast x-ray optics-on-a-chip based on MEMS capable of modulating hard x-ray pulses exceeding 350 MHz, 10 3 × higher than any other mechanical modulator, with a pulse purity >10 6 without compromising the spectral brilliance. Moreover, the timing characteristics of the devices can be tuned on-the-fly to deliver optimal pulse properties to create a host of dynamic x-ray instruments and applications, impossible with traditional optics of 10 9 × bulkier and more massive. The advent of the ultrafast optics-on-a-chip heralds a new paradigm of x-ray photonics, time-domain science, and accelerator diagnostics, especially at not only the future-generation light sources that offer coherent and high-frequency pulses but also lab-based facilities that normally do not offer timing structures.

42 ENGINEERING↗

Spectral and temporal shaping of spectrally incoherent pulses in the infrared and ultraviolet

Laser–plasma instabilities (LPIs) hinder the interaction of high-energy laser pulses with targets. Simulations show that broadband spectrally incoherent pulses can mitigate these instabilities. Optimizing laser operation and target interaction requires controlling the properties of these optical pulses. We demonstrate closed-loop control of the spectral density and pulse shape of nanosecond spectrally incoherent pulses after optical parametric amplification in the infrared (∼1053 nm) and sum–frequency generation to the ultraviolet (∼351 nm) using spectral and temporal modulation in the fiber front end. The high versatility of the demonstrated approaches can support the generation of high-energy, spectrally incoherent pulses by future laser facilities for improved LPI mitigation.

47 OTHER INSTRUMENTATION↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗