Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “progressive precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Two-Nucleon Short-Range Correlations in Light Nuclei

Understanding the nucleon-nucleon interaction is a fundamental task in nuclear physics, as NN interaction models are a crucial input to modern nuclear structure calculations. While great progress has been made toward understanding this interaction, the available state-of-the-art models predict significantly different behaviors at short distances and high momenta (scale-and-scheme dependence), where two-nucleon Short-Range Correlations (SRCs) dominate the nuclear wave function. Thus, SRCs are a unique tool to constrain the NN interaction and vice versa. SRCs are naturallyoccurring high-local-density NN pairs that, as a result of their short-distance (approx. 0.1 fm) repulsive interaction, fly apart with high momenta, hence populating momentum states above the Fermi level. The study of SRCs also has significant implications for other fields, such as the astrophysics of neutron stars and the behavior of cold atomic gasses. This thesis describes experimental and phenomenological studies of the short-distance / high-momentum structure of the NN interaction through the study of SRCs and vice versa. Experimentally, I report the first measurement of the 3He and 3H(e,e'p) reactions in Hall A of the Thomas Jefferson National Accelerator Facility in kinematics in which the measured cross sections should be sensitive to the underlying nucleon momentum distributions in the range 40 to 500 MeV/c. The resulting cross-section ratios and absolute cross sections were compared to momentum-distribution ratios and precise cross-section calculations respectively. Phenomenologically, I report the generalization of the Contact Formalism (GCF) to nuclear systems, which exploits scale separation and universality to describe nucleons at short distances and high momenta.

Cruz Torres, Reynier↗

Kubernetes for the Deep Underground Neutrino Experiment Data Acquisition

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino experiment based in the USA which is expected to start taking data in 2029. DUNE aims to precisely measure neutrino oscillation parameters by detecting neutrinos from the LBNF beamline (Fermilab) at the Far Detector, 1,300 kilometres away, in South Dakota at the Sanford Underground Research Facility. The Far Detector will consist of four cryogenic Liquid Argon Time Projection Chamber detectors of 17 kT, each producing more than 1 TB/sec of data. The main requirements for the data acquisition system are the ability to run continuously for extended periods of time, with a 99% up-time requirement, and the functionality to record both beam neutrinos and low energy neutrinos from the explosion of a neighbouring supernova, should one occur during the lifetime of the experiment. The key challenges are the high data rates that the detectors generate and the deep underground environment, which places constraints on power and space. To overcome these challenges, DUNE plans to use a highly optimised C++ software suite and a server farm of about 110 nodes continuously running about two hundred multicore processes located close to the detector, 1.5 kilometres underground. Thirty nodes will be at the surface and will run around two hundred processes simultaneously. DUNE is studying the use of the Kubernetes framework to manage containerised workloads and take advantage of its resource definitions and high up-time services to run the DAQ system. Progress in deploying these systems at the CERN neutrino platform on the prototype DUNE experiments is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEAT: A Microarcsec Astrometric Telescope

NEAT, Nearby Exo-Earth Astrometric Telescope is a medium-small telescope ~ 1m in diameter that is designed to make ultra precise < 1 uas (microarcsec) astrometric measurements of nearby stars in a ~ 1hr observation. Four major error sources prevent normal space telescopes from obtaining accuracies close to 1 uas. Even with a small 1m telescope, photon noise is usually not a problem for the bright nearby target stars. But in general, the reference stars are much fainter. Typically a field of view of ~0.5 deg dia is needed to obtain enough bright reference stars. The NEAT concept uses a very simple but unusual design to avoid optically induced astrometric errors. The third source of error is the accuracy and stability of the focal plane. A 1uas error over a ~2000 arcsec field of view implies the focal plane is accurate or at least stable to 5 parts in 1010 over the lifetime of the mission (~5yrs). The 4th class of error has to do with our knowledge of the PSF and how that PSF is sampled by an imperfect detector. A Nyquist sampled focal plane would have > 2 pixels per ?/D, and centroiding to 1uas means centroiding to 10-5 pixels. This paper describes the mission concept, and an overview of the technology needed to perform 1uas astrometry with a small telescope, and how we overcome problems 1 and 2. A companion paper will describe the technical progress we've made in solving problems 3 and 4.

interferometry↗

The limits and challenges of error field correction for ITER

Significant progress has been made in interpreting the effects of non-axisymmetric 'error' fields on a plasma through ideal MHD stability and a dominant 'least stable' ideal mode through which the fields couple to the tearing resonant surface. However, in contrast to expectations from such theories, experiments have found limited success in correcting error fields, with single correction coil arrays giving benefits of between 0% and {approx}50% correction (in terms of improvement to a low density locked mode limit), dependent on the structure of the error and correcting fields. With additional coils up to {approx}70% is possible. It was unclear whether this represented an intrinsic stability or control limit, or higher order toroidal or poloidal harmonic effects. Thus, studies on the DIII-D tokamak explored correction of a proxy error field, using two differently structured coil arrays. This enabled the principles of error correction to be tested at high amplitudes and operational densities, with known pure n=1 fields. Results showed substantial residual effects from the corrected n=1 field, with improvements of only {approx}50% in the low density locked mode limit. This suggests that n=1 error fields must couple to more than one surface in the plasma, and this is conjectured to be through more than one ideal mode, thereby requiring precise correction. For ITER, updated predictions of field error have been obtained and compared with revised scalings for tearing mode thresholds, indicating 50% or better error field correction will be needed. This will likely require more than one well coupled correction coil array and sets a challenge for theory to model the behavior, in order to clarify the plasma response and braking mechanisms, and so the effectiveness of ITER's correction coils and the possible need for support from its edge localized mode control coils.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring system for the quality assessment in additive manufacturing

Additive Manufacturing (AM) refers to a process by which a set of digital data -representing a certain complex 3dim design - is used to grow the respective 3dim real structure equal to the corresponding design. For the powder-based EOS manufacturing process a variety of plastic and metal materials can be used. Thereby, AM is in many aspects a very powerful tool as it can help to overcome particular limitations in conventional manufacturing. AM enables more freedom of design, complex, hollow and/or lightweight structures as well as product individualisation and functional integration. As such it is a promising approach with respect to the future design and manufacturing of complex 3dim structures. On the other hand, it certainly calls for new methods and standards in view of quality assessment. In particular, when utilizing AM for the design of complex parts used in aviation and aerospace technologies, appropriate monitoring systems are mandatory. In this respect, recently, sustainable progress has been accomplished by joining the common efforts and concerns of a manufacturer Additive Manufacturing systems and respective materials (EOS), along with those of an operator of such systems (MTU Aero Engines) and experienced application engineers (Carl Metrology), using decent know how in the field of optical and infrared methods regarding non-destructive-examination (NDE). The newly developed technology is best described by a high-resolution layer by layer inspection technique, which allows for a 3D tomography-analysis of the complex part at any time during the manufacturing process. Thereby, inspection costs are kept rather low by using smart image-processing methods as well as CMOS sensors instead of infrared detectors. Moreover, results from conventional physical metallurgy may easily be correlated with the predictive results of the monitoring system which not only allows for improvements of the AM monitoring system, but finally leads to an optimisation of the quality and insurance of material security of the complex structure being manufactured. Both, our poster and our oral presentation will explain the data flow between the above mentioned parties involved. A suitable monitoring system for Additive Manufacturing will be introduced, along with a presentation of the respective high resolution data acquisition, as well as the image processing and the data analysis allowing for a precise control of the 3dim growth-process.

36 MATERIALS SCIENCE↗

Time-of-Flight Estimation for Nondestructive Evaluation

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the classical approaches to the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detectionof apart under investigation. A primary ingredient in UT besides the required precision robotic hardware for theacquisition of high-qualitymeasurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report,we discuss the basic steps in UT signal processing along with current capabilities that must be achieved in order to satisfy the criticaldemands of the various LLNL programs.In itsbasic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques toextract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonicexcitation from a physics-based perspective. Once developed, we briefly discussthe various choices of excitation signals and their tradeoffs.Next,we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.”The underlying pre-and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data.Finally, we present some results for processing “weld” data when the ultrasonic excitation signal is not directly available.

42 ENGINEERING↗

Micro-sensors for in-situ meteorological measurements

Improved in-situ meteorological measurements are needed for monitoring the weather and climate of the terrestrial and Martian atmospheres. We have initiated a program to assess the feasibility and utility of micro-sensors for precise in-situ meteorological measurements in these environments. Sensors are being developed for measuring pressure, temperature, wind velocity, humidity, and aerosol amounts. Silicon micro-machining and large scale integration technologies are being used to make sensors that are small, rugged, lightweight, and require very little power. Our long-term goal is to develop very accurate miniaturized sensors that can be incorporated into complete instrument packages or 'micro weather stations,' and deployed on a variety of platforms. If conventional commercially available silicon production techniques can be used to fabricate these sensor packages, it will eventually be possible to mass-produce them at low cost. For studies of the Earth's troposphere and stratosphere, they could be deployed on aircraft, dropsondes, radiosondes, or autonomous surface stations at remote sites. Improved sensor accuracy and reduced sensor cost are the primary challenges for these applications. For studies of the Martian atmosphere, these sensor packages could be incorporated into the small entry probes and surface landers that are being planned for the Mars Environmental SURvey (MESUR) Mission. That decade-long program will deploy a global network of small stations on the Martian surface for monitoring meteorological and geological processes. Low mass, low power, durability, large dynamic range and calibration stability are the principal challenges for this application. Our progress on each of these sensor types is presented.

Crisp, David↗

MAML1 regulates cell viability via the NF-{kappa}B pathway in cervical cancer cell lines

The Notch signaling pathway plays important roles in tumorigenesis in a context-dependent manner. In human cervical cancer, alterations in Notch signaling have been reported, and both tumor-suppressing and tumor-promoting roles of Notch signaling have been proposed; however, the precise molecular mechanisms governing these roles in cervical cancer remain controversial. MAML is a transcriptional co-activator originally identified by its role in Notch signaling. Recent evidence suggests that it also plays a role in other signaling pathways, such as the p53 and {beta}-catenin pathways. MAML is required for stable formation of Notch transcriptional complexes at the promoters of Notch target genes. Chromosomal translocations affecting MAML have been shown to promote tumorigenesis. In this study, we used a truncated dominant-negative MAML1 (DN-MAML) to investigate the role of MAML in HPV-positive cervical cancer cell lines. Three human cervical cancer cell lines (HeLa, SiHa and CaSki) expressed all Notch receptors and the Notch target genes Hes1 and MAML1. Among these 3 cell lines, constitutive appearance of cleaved Notch1 was found only in CaSki cells, which suggests that Notch1 is constitutively activated in this cell line. Gamma secretase inhibitor (GSI) treatment, which suppresses Notch receptor activation, completely abrogated this form of Notch1 but had no effect on cell viability. Overexpression of DN-MAML by retroviral transduction in CaSki cells resulted in significant decreases in the mRNA levels of Hes1 and Notch1 but had no effects on the levels of MAML1, p53 or HPV E6/E7. DN-MAML expression induced increased viability of CaSki cells without any effect on cell cycle progression or cell proliferation. In addition, clonogenic assay experiments revealed that overexpression of DN-MAML resulted in increased colony formation compared to the overexpression of the control vector. When the status of the NF-{kappa}B pathway was investigated, CaSki cells overexpressing DN-MAML exhibited loss of phospho-I{kappa}B{alpha}, decreased total I{kappa}B{alpha} and nuclear localization of NF-{kappa}B p65, which suggests that the NF-{kappa}B pathway is hyperactivated. Furthermore, increased level of cleaved Notch1 was detected when DN-MAML was expressed. When DN-MAML-overexpressing cells were treated with GSI, significantly decreased cell viability was observed, indicating that inhibition of Notch signaling using GSI treatment and DN-MAML expression negatively affects cell viability. Taken together, targeting Notch signaling using DN-MAML and GSI treatment may present a novel method to control cell viability in cervical cancer cells.

60 APPLIED LIFE SCIENCES↗

Model-Based Ultrasonic SignalProcessing for the Nondestructive Evaluation of Additive Manufacturing Components

Ultrasonic testing (UT) for nondestructive evaluation (NDE) is a critical entity necessary to resolve both the quality and precision questions of complex parts evolving from the innovative additive manufacturing (AM) process. This modality provides the essential quantitative information for acceptance and potential flaw detection of the part under investigation. A primary ingredient in UT besides the required precision robotic hardware for the acquisition of high quality measurement data is the underlying signal processing. It is here that much of the system performance capability resides. In this report, we discuss the basic steps in UT signal processing along with current and future capabilities that must be achieved in order to satisfy the critical demands created by the AM process. In its basic foundations, signal processing is essentially the “extraction of critical information (signals) from noisy, uncertain data.” Clearly, in a perfect world the best signal processing is none---just make a reliable, noise-free, uncertainty-free, measurement. Unfortunately, even the best of systems is still straddled within the confines and limitations of physical instrumentation. With this in mind, we discuss the development of signal processing techniques to extract the desired UT information from noisy measurement data. We start with a discussion of a simple homogeneous representation of a “part” under investigation and its insonification by an ultrasonic excitation from a physics-based perspective. Once developed, we briefly discuss the various choices of excitation signals and their tradeoffs. Next we discuss a simulation approach employing simple models from the signal processing perspective and then move on to the development of the basic signal processing approach to ultrasonic signal processing all based on estimating the pulse arrival estimation. Starting with simple peak detection techniques, progressing to the processing workhorse so-called “matched-filter” and finally to the more sophisticated “model-based matched filter.” The underlying pre- and post-processing of noisy measurement data along with the application of these techniques are subsequently demonstrated on experimental ultrasonic data. Finally, we discuss some open problems in UT and suggest a much more sophisticated model-based approach expanding these revolutionary ideas and encompassing more realistic signal models that incorporate noise, jitter and other pertinent uncertainties into the processor.

36 MATERIALS SCIENCE↗

Size Exclusion Chromatography Studies of the Initial Self-Association Steps of Chicken Egg White Lysozyme Nucleation

Nucleation is one of the least understood aspects of crystallogenesis. In the case of macromolecule nucleation, this understanding is further hampered by uncertainty over what precisely is being discussed. We define the process of solute self-association (aggregation, oligomerization, interaction, clustering, etc.) whereby n-mers (n > or = 2) having a crystallographic or nascent crystallographic arrangement leading to the critical nucleus reversibly form in the solution, to be part of the nucleation process. This reversible self-association process is a fundamental part of the nucleation process, and occurs as a function of the solute concentration. In the case of chicken egg white lysozyme, a considerable body of experimental evidence leads us to the conclusion that it also forms the crystal growth units. Size exclusion chromatography is a simple and direct method for determining the equilibrium constants for the self-association process. A Pharmacia FPLC system was used to provide accurate solution flow rates. The column, injection valve, and sample loop were all mounted within a temperature-controlled chamber. Chromatographically re-purified lysozyme was first dialyzed against the column equilibration buffer, with injection onto the column after several hours pre-incubation at the running temperature. Preliminary experiments, were carried out using a Toyopearl HW-50F column (1 x 50cm), equilibrated with 0.1 M sodium acetate, 5% sodium chloride, pH 4.6, at 15C. Protein concentrations from 0.1 to 4 mg/ml were employed (C(sub sat) = 1.2 mg/ml). The data from several different protein preparations consistently shows a progressively decreasing elution volume with increasing protein concentration, indicating that reversible self-association is occurring. The dotted line indicates the monomeric lysozyme elution volume. However, lysozyme interacts with the column matrix in these experiments, which complicates data analysis.Accordingly, we are testing silica-based HPLC columns in an effort to eliminate this problem and substantially reduce the column volume and experimental run time. The results and data analysis from these and subsequent experiments will be presented.

Ewing, Felecia↗

A COMPARISON OF STELLAR ELEMENTAL ABUNDANCE TECHNIQUES AND MEASUREMENTS

Stellar elemental abundances are important for understanding the fundamental properties of a star or stellar group, such as age and evolutionary history, as well as the composition of an orbiting planet. However, as abundance measurement techniques have progressed, there has been little standardization between individual methods and their comparisons. As a result, different stellar abundance procedures determine measurements that vary beyond the quoted error for the same elements within the same stars. The purpose of this paper is to better understand the systematic variations between methods and offer recommendations for producing more accurate results in the future. We invited a number of participants from around the world (Australia, Portugal, Sweden, Switzerland, and the United States) to calculate 10 element abundances (C, O, Na, Mg, Al, Si, Fe, Ni, Ba, and Eu) using the same stellar spectra for four stars (HD 361, HD 10700, HD 121504, and HD 202206). Each group produced measurements for each star using (1) their own autonomous techniques, (2) standardized stellar parameters, (3) a standardized line list, and (4) both standardized parameters and a line list. We present the resulting stellar parameters, absolute abundances, and a metric of data similarity that quantifies the homogeneity of the data. We conclude that standardization of some kind, particularly stellar parameters, improves the consistency between methods. However, because results did not converge as more free parameters were standardized, it is clear there are inherent issues within the techniques that need to be reconciled. Therefore, we encourage more conversation and transparency within the community such that stellar abundance determinations can be reproducible as well as accurate and precise.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAT: A Microarcsec Astrometric Telescope

NEAT, Nearby Exo-Earth Astrometric Telescope is a medium-small telescope (is) approximately 1m in diameter that is designed to make ultra precise (is) less than 1 uas (microarcsec) astrometric measurements of nearby stars in a (is) approximately 1hr observation. Four major error sources prevent normal space telescopes from obtaining accuracies close to 1 uas. Even with a small 1m telescope, photon noise is usually not a problem for the bright nearby target stars. But in general, the reference stars are much fainter. Typically a field of view of (is) approximately 0.5 deg dia is needed to obtain enough bright reference stars. The NEAT concept uses a very simple but unusual design to avoid optically induced astrometric errors. The third source of error is the accuracy and stability of the focal plane. A 1uas error over a (is) approximately 2000 arcsec field of view implies the focal plane is accurate or at least stable to 5 parts in 10(exp 10) over the lifetime of the mission ( (is) approximately 5yrs). The 4th class of error has to do with our knowledge of the PSF and how that PSF is sampled by an imperfect detector. A Nyquist sampled focal plane would have (is) greater than 2 pixels per lambda/D, and centroiding to 1uas means centroiding to 10-5 pixels. This paper describes the mission concept, and an overview of the technology needed to perform 1uas astrometry with a small telescope, and how we overcome problems 1 and 2. A companion paper will describe the technical progress we've made in solving problems 3 and 4.

Earth like planets↗

Fecal microbiota transplantation ameliorates type 2 diabetes via metabolic remodeling of the gut microbiota in db/db mice

Gut microbiome (GM) deregulation has been implicated in major conditions such as obesity and type 2 diabetes (T2DM). Our previous prospective study indicated that fecal microbiota transplantation (FMT) successfully improved patients with T2DM. We hypothesized that FMT may be a potential therapeutic method for T2DM, but its precise mechanisms in T2DM remains to be elucidated. Eight db/m mice were FMT donors and control mice, and 16 genetically diabetic db/db mice were equally divided into two groups (db/db+phosphate-buffered saline (PBS) group, db/db+FMT group). The db/db+FMT group was administered fresh fecal suspension (0.2 mL/mice) daily for 4 weeks. Analysis of the GM and serum metabolome was carried out by 16S ribosomal RNA sequencing and liquid chromatogram-mass spectrometry, respectively. Effects of FMT on the gut barrier and pancreas were assessed using protein assays, messenger RNA, immunohistology and clinical indicators testing. Our results showed that FMT treatment of db/db mice relieves a series of clinical indicators, including fasting plasma glucose, serum insulin and oral glucose tolerance test among others. Compared with non-diabetic control mice, db/db+PBS mice exhibited decreased abundance of Ruminococaceae, Porphyromonadaceae and increased abundance of Rikenellaceae and Lactobacillaceae. FMT treatment reversed this effect on the microbiome. Eleven metabolites were changed between the db/db+PBS and db/db+FMT groups. Correlation analysis showed that the structural changes of the GM were correlated with host metabolite levels. We further showed that FMT treatment of db/db mice improved intestinal barrier function, reduced inflammation and caused an alteration in the number of circulating immune cells. FMT-mediated changes in the GM, serum metabolites, intestinal epithelial barrier, inflammation and circulating immune cells play an important role in the efficacy of FMT on T2DM disease progression.

60 APPLIED LIFE SCIENCES↗

The Zwicky Transient Facility: Data Processing, Products, and Archive

The Zwicky Transient Facility (ZTF) is a new robotic time-domain survey currently in progress using the Palomar 48-inch Schmidt Telescope. ZTF uses a 47 square degree field with a 600 megapixel camera to scan the entire northern visible sky at rates of ∼3760 square degrees/hour to median depths of g ~ 20.8 and r ~ 20.6 mag (AB, 5σ in 30 sec). We describe the Science Data System that is housed at IPAC, Caltech. This comprises the data-processing pipelines, alert production system, data archive, and user interfaces for accessing and analyzing the products. The real-time pipeline employs a novel image-differencing algorithm, optimized for the detection of point-source transient events. These events are vetted for reliability using a machine-learned classifier and combined with contextual information to generate data-rich alert packets. The packets become available for distribution typically within 13 minutes (95th percentile) of observation. Detected events are also linked to generate candidate moving-object tracks using a novel algorithm. Objects that move fast enough to streak in the individual exposures are also extracted and vetted. We present some preliminary results of the calibration performance delivered by the real-time pipeline. The reconstructed astrometric accuracy per science image with respect to Gaia DR1 is typically 45 to 85 milliarcsec. This is the RMS per-axis on the sky for sources extracted with photometric S/N ≥10 and hence corresponds to the typical astrometric uncertainty down to this limit. The derived photometric precision (repeatability) at bright unsaturated fluxes varies between 8 and 25 millimag. The high end of these ranges corresponds to an airmass approaching ∼2—the limit of the public survey. Photometric calibration accuracy with respect to Pan-STARRS1 is generally better than 2%. The products support a broad range of scientific applications: fast and young supernovae; rare flux transients; variable stars; eclipsing binaries; variability from active galactic nuclei; counterparts to gravitational wave sources; a more complete census of Type Ia supernovae; and solar-system objects.

Frank J. Masci↗

Process Cost Modeling for Multi-Disciplinary Design Optimization

For early design concepts, the conventional approach to cost is normally some kind of parametric weight-based cost model. There is now ample evidence that this approach can be misleading and inaccurate. By the nature of its development, a parametric cost model requires historical data and is valid only if the new design is analogous to those for which the model was derived. Advanced aerospace vehicles have no historical production data and are nowhere near the vehicles of the past. Using an existing weight-based cost model would only lead to errors and distortions of the true production cost. This report outlines the development of a process-based cost model in which the physical elements of the vehicle are costed according to a first-order dynamics model. This theoretical cost model, first advocated by early work at MIT, has been expanded to cover the basic structures of an advanced aerospace vehicle. Elemental costs based on the geometry of the design can be summed up to provide an overall estimation of the total production cost for a design configuration. This capability to directly link any design configuration to realistic cost estimation is a key requirement for high payoff MDO problems. Another important consideration in this report is the handling of part or product complexity. Here the concept of cost modulus is introduced to take into account variability due to different materials, sizes, shapes, precision of fabrication, and equipment requirements. The most important implication of the development of the proposed process-based cost model is that different design configurations can now be quickly related to their cost estimates in a seamless calculation process easily implemented on any spreadsheet tool. In successive sections, the report addresses the issues of cost modeling as follows. First, an introduction is presented to provide the background for the research work. Next, a quick review of cost estimation techniques is made with the intention to highlight their inappropriateness for what is really needed at the conceptual phase of the design process. The First-Order Process Velocity Cost Model (FOPV) is discussed at length in the next section. This is followed by an application of the FOPV cost model to a generic wing. For designs that have no precedence as far as acquisition costs are concerned, cost data derived from the FOPV cost model may not be accurate enough because of new requirements for shape complexity, material, equipment and precision/tolerance. The concept of Cost Modulus is introduced at this point to compensate for these new burdens on the basic processes. This is treated in section 5. The cost of a design must be conveniently linked to its CAD representation. The interfacing of CAD models and spreadsheets containing the cost equations is the subject of the next section, section 6. The last section of the report is a summary of the progress made so far, and the anticipated research work to be achieved in the future.

Bao, Han P.↗

Closeout Report of BNL LDRD 23-050 A Second EIC Detector: Physics Case and Conceptual Design

This document is the closeout report for LDRD 23-050, a type-A LDRD project awarded in FY2022 under the title “ A Second EIC Detector: Physics Case and Conceptual Design ”. The project was motivated by the strong interest within the EIC community in a second general-purpose detector and interaction region, and by the recognition that such a detector is essential to fully exploit the scientific potential of the EIC over its multi-decade lifetime. The key goals of the LDRD were to (i) strengthen the case for a second EIC detector, building on the arguments already articulated in the community Yellow Report, (ii) provide a realistic detector concept that is complementary to the current project detector, ePIC, in terms of physics reach, precision, and control of systematics, and (iii) broaden the overall physics program of the EIC facility. Since a possible second detector is expected to be realized with a delay of several years relative to the first detector, the project explicitly aimed at identifying technologies that are not yet sufficiently mature for ePIC but could be deployed on the later timescale of a second detector, thereby providing genuine complementarity and room for innovation. LDRD 23-050 provided support for two postdoctoral researchers and partial support for several BNL staff members, and the effort ramped up in mid-2023. Work was carried out in close collaboration with colleagues from the EIC project, the Cold QCD and STAR groups at BNL, and with substantial input from members of the EIC User Group and the ePIC Collaboration as reflected in the author list. Over the period from October 2022 through September 2025, this team developed and refined a physics program tailored to a second detector, translated the resulting physics requirements into detector-level performance targets, and explored multiple conceptual detector layouts capable of meeting these targets within the constraints of the second interaction region. The expected outcome, as stated in the original proposal, was a document detailing the physics potential and requirements of a second EIC detector, accompanied by a comprehensive conceptual detector design and an outline of the remaining R&D needed to bring the relevant technologies to maturity. The present report summarizes the progress that has been achieved toward these goals. It consolidates the physics studies, detector concepts, and technology assessments developed under this LDRD and places them in the broader context of worldwide detector R&D. While the evolving priorities of the EIC project and the substantial community effort required to design and construct ePIC naturally limited the scope of EIC-wide activities toward a second detector during this period, the work documented here is intended to provide a foundation and a point of reference for future efforts. Whatever form a second EIC detector may ultimately take, we hope that this report will serve as a useful guide for colleagues who continue to advance this program in the near- and mid-term future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗

High-resolution microcalorimeter detectors as a tool in the future of nuclear safeguards

New measurements are presented from the LANL-NIST microcalorimeter array for two standard plutonium sources. The results demonstrate substantially smaller error bars obtained from the spectral analysis program FRAM. Some areas of improvement to the analysis technique have been identified, indicating that the micro calorimeter results can be improved upon. These results support the viability of a device for performing real nuclear safeguards measurements in the near future. The challenge of providing reliably accurate and precise data is a critical component of any safeguards initiative. In the realm of nuclear safeguards, this is an especially daunting task since inaccurate and/or imprecise data could have very serious international consequences. As such, there is a constant drive within the community to establish better measurement and analysis techniques in order to further reduce the associated errors and uncertainties. Even with todays state of the art equipment, measurement uncertainties can extend to several significant quantities worth of material over a relatively modest period of time. Furthermore, there is a strong desire for improved nondestructive analysis techniques in order to reduce both the cost, turnover rate, and inconvenience of destructive analyses. One promising new technology that may help to realize these goals is that of gamma-ray microcalorimeter detectors. The hallmark quality of this new technique is the ability to achieve energy resolution nearly an order of magnitude better than typical planar high-purity germanium (HPGe) detectors. Such an improvement may help reduce uncertainties associated with, for instance, plutonium isotopics or uranium enrichment measurements. This may, in turn, help to reduce uncertainties in total plutonium and/or uranium content in a given sample without the need for destructive analysis. In this paper, we will describe this new detector technology as well as some recent measurements carried out with the LANL-NIST gamma-ray microcalorimeter ({micro}cal) array. Discussion will focus on the capabilities of this technology as well as the progress toward a practical measurement device.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗