Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power switching”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Spin-Correlated Radical Pairs as Magnetic Switches for Controlling Emissive Triplet States via Triplet–Triplet Energy Transfer

Magnetic fields offer a powerful means to control molecular emission, enabling quantum sensing and spin-level control of chemical reactions. Here, we demonstrate a strategy to magnetically control red to near-infrared phosphorescence via triplet–triplet energy transfer (TTET) from donor–chiral bridge–acceptor (D−χ–A) molecules that generate spin-correlated radical pairs (SCRPs) upon photoexcitation. These SCRPs yield non-emissive triplet excited states whose formation is sensitive to magnetic fields. Here, by transferring this energy to emissive Pt- and Pd-based π-extended porphyrins, we enable magnetic control over phosphorescence that would otherwise be unresponsive to weak magnetic fields (<1 T). This approach establishes a platform for quantifying magnetic field effects on silent triplet states while extending magnetically responsive emission into the near-infrared. Coupling SCRP-based molecular magnetic switches to long-wavelength emissive acceptors offers a new way for probing and modulating spin-dependent processes and triplet-state populations in molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Description of a 20 Kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution link; mulitphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗

Description of a 20 kilohertz power distribution system

A single phase, 440 VRMS, 20 kHz power distribution system with a regulated sinusoidal wave form is discussed. A single phase power system minimizes the wiring, sensing, and control complexities required in a multi-sourced redundantly distributed power system. The single phase addresses only the distribution links multiphase lower frequency inputs and outputs accommodation techniques are described. While the 440 V operating potential was initially selected for aircraft operating below 50,000 ft, this potential also appears suitable for space power systems. This voltage choice recognizes a reasonable upper limit for semiconductor ratings, yet will direct synthesis of 220 V, 3 power. A 20 kHz operating frequency was selected to be above the range of audibility, minimize the weight of reactive components, yet allow the construction of single power stages of 25 to 30 kW. The regulated sinusoidal distribution system has several advantages. With a regulated voltage, most ac/dc conversions involve rather simple transformer rectifier applications. A sinusoidal distribution system, when used in conjunction with zero crossing switching, represents a minimal source of EMI. The present state of 20 kHz power technology includes computer controls of voltage and/or frequency, low inductance cable, current limiting circuit protection, bi-directional power flow, and motor/generator operating using standard induction machines. A status update and description of each of these items and their significance is presented.

Hansen, I. G.↗

A 20-kW DC Oak Ridge Converter with Integrated AC & DC Sources for Grid Services and Energy Storage Systems

This paper proposes a wireless power transfer (WPT) platform with integrated energy conversion that has the capability for 1) recharging the energy storage systems (ESSs) from the grid systems, including renewable energy sources such as wind, solar, etc., 2) off grid systems recharging the ESSs from dc grid systems, 3) grid recharging of electric vehicles (EVs), and 4) off grid recharging of EVs from ESSs. The unique aspect of the method is the use of multi-interface power electronic converter for the grid and ESSs and EVs that can support a range of applications with ac / dc and dc / dc energy conversion ability in a single converter system. The key enabling technology to achieve these functionalities is Oak Ridge Converter (ORC) with polyphase coupler coil system both developed at ORNL. This new technology enables higher power density WPT systems while allowing the coils to interface from ac grid at 60 Hz frequency or dc source directly merging with 85 kHz operating frequency of switching component. The experimental results of the proposed system are presented for 20 kW output power with the system overall efficiency around 95.4% from dc source and 93% overall efficiency from ac grid achieving 9-10% current total harmonic distortion (THD) and 0.98-0.99 power factor (PF).

Asa, Erdem↗

In-Package Common-Mode Filter for GaN Power Module with Improved Radiated EMI Performance

This paper discusses the impact of parasitic inductances on the electromagnetic interference (EMI) performance at radiated frequency and provides a new concept for high-frequency wide bandgap (WBG) power module package design with integrated π-type common mode filter (π-CMF). The connection parasitic-inductances of a π-type CMF model are analyzed, and the parasitic inductances from the CMF to the CM noise source and to the heatsink are minimized to improve the CMF's EMI performance in the radiated frequency range. Therefore, placing the π-CMF closer to the power module (i.e. in-package CMF) provides a larger noise attenuation compared to placing it outside the module (i.e. external CMF). To verify the theoretical analysis, a half-bridge GaN power module with an in-package π-CMF is designed, and experiments are conducted by comparing the attenuated noise spectrums of a 70-V/1.75-A hard-switching buck converter built by the designed module with an external CMF and the power-module integrated CMF. According to the experiment results, up to 10 dBμV more attenuation is achieved by the in-package CMF than the external CMF, validating the analytical conclusion.

Xue, Lincoln↗

Switched low-dropout voltage regulator

High-resolution switched digital regulators are disclosed having fast cross corner and variable temperature response, with constrained ripple. The strength of the power transistors utilized by the regulator are adjusted to control the current delivered to the load. The regulators utilize a slow control loop in parallel with a primary fast switching loop. The slow loop uses the switching signal of the primary loop to estimate the load current and set the power transistor size accordingly.

Kudva, Sudhir Shrikantha↗

Understanding Transient Combustion Phenomena in Low-NO x Gas Turbines

The goal of this work was to understand, quantify, and eventually predict combustion instability during operational transients in low-NO x gas turbine combustors. Transient operation is defined as a mode where one or more key operating parameters, including equivalence ratio, fuel composition, or fuel splitting between nozzles in a combustor, are varying in time. The timescale over which this variation occurs will be referred to as the transient timescale, the magnitude of the change in the transient parameter will be referred to as the transient amplitude, and the direction of the variation will be referred to as the transient direction. Transients occur regularly in power generation gas turbine operation. For example, load-following gas turbines vary load to meet power demands while accounting for variation in unsteady grid contributors like wind and solar power. Operators achieve this by varying equivalence ratio and fuel splitting inside the combustors to produce more or less power. Another example of transient operation is during fuel-switching operations, a particular issue for turbines operating with syngas fuels in a co-generation facility. In this case, the composition of the fuel stream may vary in time either as a result of fluctuations in the pipeline, or in the case of a co-generation plant, variations in feedstock or gasification processes. This fluctuation in fuel composition can have significant implications for combustion processes, particularly with high-hydrogen fuels. A small number of studies have investigated transient behavior in gas turbine combustors, particularly in the context of flame blow-off; here, investigators have typically focused on issues of transient amplitude, though without the depth and physics-based experimental design that is proposed in this program. To our knowledge, there have been no studies that have quantified the impact of the transient timescale on combustion. The work helped us understand the impact of several types of transients on combustion stability. Both static and dynamic combustion stability will be considered. The transients will be quantified using their amplitude, direction, and timescale, and we will consider transients in equivalence ratio, fuel composition, and fuel splitting. There were two main objectives of this work: 1. Provide a fundamental understanding of combustion stability during transient operation using data obtained from a number of high-speed diagnostic techniques on experimental configurations that capture important gas turbine combustor features and operating conditions. This goal was met in conjunction with our industrial partner, GE Global Research, with whom we worked closely throughout the program. 2. Develop a stability prediction framework that will allow for the prediction, and possible control, of instabilities as a function of the transient amplitude, direction, and timescale. This input/output model should be physics-based and allow for screening of operating conditions and prediction of unstable behavior at the end of a transient by monitoring combustor health and precursor signals during operation.

03 NATURAL GAS↗

A nonsaturating dc-to-dc parallel power converter

Device is conventional circuit modified with pair of diode rectifiers coupled to switching transistors via feedback winding. Transient-causing collector-current overlap between transistors is eliminated. Technique may be used with nonsaturating parallel-transistor converters operating from voltage source which remains fixed or varies over small range.

Lavigna, T.↗

PWM Switching Frequency Effects on Eddy Current Sensors for Magnetically Suspended Flywheel Systems

A flywheel magnetic bearing (MB) pulse width modulated power amplifier (PWM) configuration is selected to minimize noise generated by the PWMs in the flywheel position sensor system. Two types of noise are addressed: beat frequency noise caused by variations in PWM switching frequencies, and demodulation noise caused by demodulation of high order harmonics of the switching voltage into the MB control band. Beat frequency noise is eliminated by synchronizing the PWM switch frequencies, and demodulation noise is minimized by selection of a switching frequency which does not have harmonics at the carrier frequency of the sensor. The recommended MB PWM system has five synchronized PWMs switching at a non-integer harmonic of the sensor carrier.

Jansen, Ralph↗

Power conversion in electrical networks

Aspects of dc to dc conversion were studied in terms of a class of switching voltage regulators from a stability viewpoint. Background concepts of nonlinear system theory were considered, including the problem of obtaining suitable realizations for a class of positive operators. It is shown that the state evolution equations for a power conversion network are in general of bilinear form, and that the theory of lie groups and lie algebras is useful in analyzing such systems. The feedback stabilization of a class of bilinear systems whose state space is a manifold is also discussed.

Wood, J. R.↗

Ring-Down Spectroscopy for Characterizing a CW Raman Laser

.A relatively simple technique for characterizing an all-resonant intracavity continuous-wave (CW) solid-state Raman laser involves the use of ring-down spectroscopy. As used here, characterizing signifies determining such parameters as threshold pump power, Raman gain, conversion efficiency, and quality factors (Q values) of the pump and Stokes cavity modes. Heretofore, in order to characterize resonant-cavity-based Raman lasers, it has usually been necessary to manipulate the frequencies and power levels of pump lasers and, in each case, to take several sets of measurements. In cases involving ultra-high-Q resonators, it also has been desirable to lock pump lasers to resonator modes to ensure the quality of measurement data. Simpler techniques could be useful. In the present ring-down spectroscopic technique, one infers the parameters of interest from the decay of the laser out of its steady state. This technique does not require changing the power or frequency of the pump laser or locking the pump laser to the resonator mode. The technique is based on a theoretical analysis of what happens when the pump laser is abruptly switched off after the Raman generation reaches the steady state. The analysis starts with differential equations for the evolution of the amplitudes of the pump and Stokes electric fields, leading to solutions for the power levels of the pump and Stokes fields as functions of time and of the aforementioned parameters. Among other things, these solutions show how the ring-down time depends, to some extent, on the electromagnetic energy accumulated in the cavity. The solutions are readily converted to relatively simple equations for the parameters as functions of quantities that can be determined from measurements of the time-dependent power levels. For example, the steady-state intracavity conversion efficiency is given by G1/G2 1 and the threshold power is given by Pin(G2/G1)2, where Pin is the steady-state input pump power immediately prior to abrupt switch-off, G1 is the initial rate of decay of the pump field, and G2 is the final rate of decay of the pump field. Hence, it is possible to determine all the parameters from a single ring-down scan, provided that the measurements taken in that scan are sufficiently accurate and complete.

Matsko, Andrey↗

The performance and efficiency of four motor/controller/battery systems for the simpler electric vehicles

A test and analysis program performed on four complete propulsion systems for an urban electric vehicle (EV) is described and results given. A dc series motor and a permanent magnet (PM) motor were tested, each powered by an EV battery pack and controlled by (1) a series/parallel voltage-switching (V-switch) system; and (2) a system using a pulse width modulation, 400 Hz transistorized chopper. Dynamometer tests were first performed, followed by eV performance predictions and data correlating road tests. During dynamometer tests using chopper control; current, voltage, and power were measured on both the battery and motor sides of the chopper, using three types of instrumentation. Conventional dc instruments provided adequate accuracy for eV power and energy measurements, when used on the battery side of the controller. When using the chopper controller, the addition of a small choke inductor improved system efficiency in the lower duty cycle range (some 8% increase at 50% duty cycle) with both types of motors. Overall system efficiency rankings during road tests were: (1) series motor with V-switch; (2) PM motor with V-switch; (3) series motor with chopper; and (4) PM motor with chopper. Chopper control of the eV was smoother and required less driver skill than V-switch control.

Shipps, P. R.↗

Acceptance Testing of a Satellite SCADA Photovoltaic-Diesel Hybrid System

Savannah State University (SSU) and the Florida Solar Energy Center (FSEC) have been participating in the NASA Advanced Communications Technology Satellite (ACTS) program for the last five years. This program was designed by NASA to help maintain U.S. leadership in commercial space communications by funding high-risk research, and to flight-test next-generation digital satellite components. Launched in 1993, ACTS is an U.S. government funded technology test-bed that incorporates high power Ka-band transponders, small spot beams, and on-board digital storage and switching technology. Associated with the spacecraft, is a prototype satellite control center that supports various application experiments. The SSU/FSEC application experiment is to developing a Photovoltaic-Diesel Hybrid Power system complete with satellite Supervisory Control and Data Acquisition (SCADA). The hybrid system was design to demonstrate the feasibility of using SCADA to maintain and operate remote village power systems. This configuration would enable experts at a central location to provide technical assistance to local technicians while they acquire a measure of proficiency with the hybrid system operation and maintenance. Upon full mastery of the technology, similar SCADA arrangement are planned to remotely monitor and control constellation of hybrid systems scattered overlarge rural areas. Two Orion Energy APEX-1000 hybrid systems were delivered in 1998, one was installed at SSU in eastern Georgia and the other was installed at FSEC in Central Florida. The project was designed to: (1) evaluate the performance of ACTS in a SCADA arrangement, (2) monitor the health and performance of all major hybrid subsystems, (3) investigate load control and battery charging strategies to maximize battery capacity and lifetime, and (4) develop satellite communication protocol. Preliminary results indicate that the hybrid design is suitable for satellite Supervisory Control and Data Acquisition. A modification to the controller software has produced a robust communication link capable of real time control and long term data collection.

Kalu, Alex↗

Cost-effective optical switch matrix for microwave phased-array

An all-fiber (6x6) optical shutter switch matrix with the control system for microwave phased array has been demonstrated. The device offers the advantages of integrated configuration, low cost, low power consumption, small size, and light weight. The maximum extinction ratio (among 36 individual pixel) of this switch matrix at 840 nm is 24.2 dB, and the switching time is less than 120 microsec. In addition to phased array application, this low cost switch matrix is extremely attractive for fiber optic switching networks.

Pan, J. J.↗

Design and Testing of a Breadboard Electrical Power Control Unit for the Fluid Combustion Facility Experiment

The Fluid Combustion Facility (FCF) Project and the Power Technology Division at the NASA Glenn Research Center (GRC) at Lewis Field in Cleveland, OH along with the Sundstrand Corporation in Rockford, IL are jointly developing an Electrical Power Converter Unit (EPCU) for the Fluid Combustion Facility to be flown on the International Space Station (ISS). The FCF facility experiment contains three racks: A core rack, a combustion rack, and a fluids rack. The EPCU will be used as the power interface to the ISS 120V(sub dc) power distribution system by each FCF experiment rack which requires 28V(sub dc). The EPCU is a modular design which contains three 120V(sub dc)-to-28V(sub dc) full-bridge, power converters rated at 1 kW(sub e) each bus transferring input relays and solid-state, current-limiting input switches, 48 current-limiting, solid-state, output switches; and control and telemetry hardware. The EPCU has all controls required to autonomously share load demand between the power feeds and--if absolutely necessary--shed loads. The EPCU, which maximizes the usage of allocated ISS power and minimizes loss of power to loads, can be paralleled with other EPCUs. This paper overviews the electrical design and operating characteristics of the EPCU and presents test data from the breadboard design.

Kimnach, Greg L.↗

A Regime-Switching Spatio-Temporal GARCH Method for Short-Term Wind Forecasting

The growth of wind energy poses challenges to the integration of wind energy into the power grid. Within a wind farm, the conditions of local wind exhibit sizeable variations in very short term period and temporal wind speed patterns vary from turbine to turbine. Hence, short-term wind forecasting has been adopted to assist power system operations. In this work, we propose a wind plant-level short term wind speed and power forecasting methodology considering turbine contributions. The proposed model utilizes spatio-temporal dependencies and nonstationarity to accommodate the characteristics of wind farm data by using a novel regime-switching spatiotemporal generalized autoregressive conditional heteroscedasticity (RS-stGARCH) model. Case studies based on 2 years of data from a wind farm shows that the proposed RS-stGARCH method outperforms benchmark models by up to 21.10% for wind speed forecasting and up to 58.62% for the wind power forecasting.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Local structure effects of carbon-doping on the phase change material Ge 2 Sb 2 Te 5

Ge 2 Sb 2 Te 5 is used in phase change memory, a nonvolatile memory technology, due to its phase change properties. The primary advantage of phase change memory over the state-of-the-art (flash memory) is its simple and small device geometry, which allows for denser nodes and lower power consumption. In phase change memory, resistive heating induces fast switching between the high resistance amorphous and low resistance crystalline phases, corresponding to storage of low and high digital states, respectively. However, the instability of the amorphous phase of Ge 2 Sb 2 Te 5 presents issues with processing and long-term data storage; such issues can be resolved by C doping, which stabilizes the amorphous phase and raises the crystallization temperature. To better understand the local structural effects of C doping on Ge 2 Sb 2 Te 5 , in situ Ge K-edge X-ray absorption spectroscopy measurements were taken during heating of films with various C doping concentrations. Here, the range of structural transformation temperatures derived from X-ray absorption near-edge structure analysis across the C doping series proved narrower than crystallization temperatures reported in similar in situ X-ray diffraction experiments, which may reflect changes in local structure that precede long-range ordering during crystallization. In addition, rigorous extended X-ray absorption fine structure fitting across and between temperature series revealed effects of C doping on the rigidity of Ge–Te bonds at low (2 at% and 4 at%) C concentrations.

Langhout, John D.↗