Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “portable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Absolute Neutron Rate Measurement and Non-Thermal/Thermonuclear Fusion Differentiation

The goal of fusion energy is to produce significantly more energy from fusion reactions than is input into the device. One of the products of fusion reactions is neutrons, which, due to their lack of charge, provide a unique view into the parameters of the device. Lawrence Livermore National Laboratory (LLNL) in collaboration with the University of California, Berkeley (UCB) have designed, assembled, and fielded a robust and portable neutron detection system known as PANDA (Portable and Adaptable Neutron Diagnostics for ARPA-E). This detector suite consists of three LaBr activation detectors that are calibrated to give a total neutron yield on shot, and twenty-four scintillators coupled to photo-multiplier tubes (SPMT). The SPMTs can be configured to attain spatial, temporal and/or energy information from fusion neutrons. The system was designed to be portable and is compartmentalized so that individual components can be used at different fusion facilities. During the duration of this work, part of the system was installed at the FuZE facility, a part of Zap Energy. Another component was installed that the CESZAR facility at the University of California, San Diego (UCSD) to support experiments by Magneto-Inertial Fusion Technologies, Inc. (MIFTI). The diagnostics were successful at both locations and the LLNL/UCB team supported the data analysis by creating and running analysis scripts and Monte-Carlo calculations. At Zap Energy the diagnostics demonstrated that the fusion from the FuZE device is thermonuclear in nature, a result that resulted in an invited talk at the American Physical Society Division of Plasma Physics and an invited paper. Additionally, temporal and spatial data was taken using the SPMTs to understand the duration and length of fusion production. At UCSD the neutron yield from the diagnostics was used to show improvements to fusion yields on their gas puff Z-pinch when using a gas shell surrounding the fuel. The success in this diagnostic has led to continued work at both Zap Energy and MIFTI, as well as follow on funding and interest at other fusion energy companies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Efficient Sparse Computations using Linear Algebra Aware Compilers

This project developed the LAPIS compiler framework, built on the Multilevel Intermediate Representation (MLIR), to optimize sparse linear algebra operations and support performance portability across diverse architectures. The main innovation of LAPIS is the Kokkos dialect, which allows for lowering codes from a high productivity language to different architectures in an elegant way. The dialect also allows the conversion of lower-level MLIR code to C++ Kokkos code, facilitating the integration of scientific machine learning (SciML) models into applications. To extend LAPIS for distributed memory architectures, a new partition dialect was created to manage the distribution of sparse tensors and express communication patterns for sparse linear algebra operations. This dialect also supports the distributed execution of operators and includes algorithmic optimizations to minimize communication to improve performance. The project also demonstrates that MLIR can enable effective linear algebra-level optimizations, improving performance on different GPUs for both sparse and dense linear algebra kernels. Key applications of LAPIS include sparse linear algebra and graph kernels, TenSQL, a relational database management solution built on GraphBLAS, and the development of subgraph isomorphism and monomorphism kernels, showcasing performance portability. In summary, the LAPIS framework supports productivity, performance, portability, and distributed memory execution, while also enabling linear algebra-level optimizations that are challenging in traditional programming languages, with successful applications ranging from simple sparse linear algebra to complex graph kernels.

97 MATHEMATICS AND COMPUTING↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lifecycle Assessment and Techno-Economic Analysis of Biochar Pellet Production from Forest Residues and Field Application

Biochar produced from low-value forest biomass can provide substantial benefits to ecosystems and mitigate climate change-induced risks such as forest fires. Forest residues from restoration activities and timber harvest and biochar itself are bulky and thus incur high logistic costs, so are considered major bottlenecks for the commercialization of the biochar industry. The objectives of this study were to assess the environmental footprints and techno-economic feasibility of converting forest residues in Pacific Northwest United States into biochar pellets using portable systems followed by delivery of the final product to end-users for land application (dispersion). Two portable systems (Biochar Solutions Incorporated (BSI) and Air Curtain Burner (ACB)) were considered for biochar production. A cradle-to-grave lifecycle assessment (LCA) and a discounted cash flow analysis method were used to quantify the environmental impacts and minimum selling price (MSP) of biochar. The global warming (GW) impact of biochar production through BSI and ACB was estimated to be 306–444, and 750–1016 kgCO₂eq/tonne biochar applied to the field, respectively. The MSP of biochar produced through BSI and ACB was 1674–1909 and 528–1051 USD/tonne biochar applied to the field, respectively. Pelletizing of biochar reduced GW impacts during outbound logistics (~8–20%) but increased emissions during pelletizing (~1–9%). Results show the BSI system was a more viable option in terms of GW impact, whereas the ACB system can produce biochar with lower MSP. The results of the study conclude that the production of biochar pellets through the two portable systems and applied to fields can be both an environmentally beneficial and economically viable option.

09 BIOMASS FUELS↗

Lunar surface magnetometers

Discussion of the properties of both the stationary and portable magnetometers used in the Apollo program to measure static and dynamic fields on the lunar surface. A stationary magnetometer is described in which the three orthogonal vector components of the magnetic field are measured by three fluxgate sensors which are located at the ends of three orthogonal booms and contain ferromagnetic cores driven to saturation by means of a periodic current. In the Apollo 16 magnetometer special high-stability ring-core sensors were used which provided an output voltage to the analog-to-digital converter which is proportional to the magnetic field. A portable magnetometer is described which consists of a set of three orthogonal fluxgate sensors mounted on top of a tripod connected to an electronics box by a ribbon cable. The above-mentioned stationary magnetometer simultaneously measured the time-varying components of the field which were later subtracted from the portable magnetometer measurements to give the desired resultant steady field values caused by the magnetized crustal material.

Dyal, P.↗

Design principles of the PORT library

The design of PORT stemmed from the basic principles of portability and ease of use. The attributes and mechanisms used in the library to support this philosophy include the use of a portable subset of FORTRAN, and the use of (machine-dependent) functions to supply the necessary environment parameters. Abbreviated calling sequences are mede possible by a simplified error-handling technique, and by the use of a portable stack allocator for temporary workspace. Experiences to date with these approaches, and plans for the future are reviewed.

Fox, P.↗

Develop real-time dosimetry concepts and instrumentation for long term missions

The development of a rugged portable instrument to evaluate dose and dose equivalent is described. A tissue-equivalent proportional counter simulating a 2 micrometer spherical tissue volume was operated satisfactorily for over a year. The basic elements of the electronic system were designed and tested. And finally, the most suitable mathematical technique for evaluating dose equivalent with a portable instrument was selected. Design and fabrication of a portable prototype, based on the previously tested circuits, is underway.

Braby, L. A.↗

Evaluation of methods for rapid determination of freezing point of aviation fuels

Methods for identification of the more promising concepts for the development of a portable instrument to rapidly determine the freezing point of aviation fuels are described. The evaluation process consisted of: (1) collection of information on techniques previously used for the determination of the freezing point, (2) screening and selection of these techniques for further evaluation of their suitability in a portable unit for rapid measurement, and (3) an extensive experimental evaluation of the selected techniques and a final selection of the most promising technique. Test apparatuses employing differential thermal analysis and the change in optical transparency during phase change were evaluated and tested. A technique similar to differential thermal analysis using no reference fuel was investigated. In this method, the freezing point was obtained by digitizing the data and locating the point of inflection. Results obtained using this technique compare well with those obtained elsewhere using different techniques. A conceptual design of a portable instrument incorporating this technique is presented.

Mathiprakasam, B.↗

Field Utilization and Analysis of AIS 128-channel Imagery Using Microcomputers: Application to Yerington, Nevada Field Area

Geologists in exploration need to be able to determine the mineral composition of a given outcrop, and then proceed to another in order to carry out the process of geologic mapping. Since April 1984 researchers have been developing a portable microcomputer-based imaging system (with a grey-scale of 16 shades of amber), which were demonstrated during the November 1984 GSA field trip in the field at Yerington, NV. A color-version of the same technology was recently demonstrated. The portable computer selected is a COLBY 10-Megabyte, hard disk-equipped repackaged-IBM/XT, which operates on either 110/220 VAC or on 12VDC from the cigarette lighter in a field vehicle. A COMPAQ PLUS or an IBM Portable will also work on modified software. The underlying concept is that the atmospheric transmission and surface albedo/slope terms are multiplicative, relating the spectral irradiance to the spectral color of the surface materials. Thus, the spectral color of a pixel remains after averaged log-albedo and log-irradiance have been estimated. All these steps can be carried out on the COLBY microcomputer, using 80 image lines of the 128-channel, 12-bit imagery. Results are shown for such an 80-line segment, showing the identification of an O-H bearing mineral group (of slightly varying specific characters) on the flight line.

Lyon, R. J. P.↗

Water quality monitor (EMPAX instrument)

The impetus of the Viking Mission to Mars led to the first miniaturization of a X-ray Fluorescence Spectrometer (XRFS). Two units were flown on the Viking Mission and successfully operated for two years analyzing the elemental composition of the Martian soil. Under a Bureau of Mines/NASA Technology Utilization project, this XRFS design was utilized to produce a battery powered, portable unit for elemental analysis of geological samples. This paper will detail design improvements and additional sampling capabilities that were incorporated into a second generation portable XRFS that was funded by the EPA/NASA Technology Utilization project. The unit, Environment Monitoring with Portable Analysis by X-ray (EMPAX), was developed specifically for quantitative determination of the need of EPA and and any industry affected by environmental concerns, the EMPAX fulfills a critical need to provide on-site, real-time analysis of toxic metal contamination. A patent was issued on EMPAX, but a commercial manufacturer is still being sought.

Kelliher, Warren C.↗

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.↗

The df: A proposed data format standard

A standard is proposed describing a portable format for electronic exchange of data in the physical sciences. Writing scientific data in a standard format has three basic advantages: portability; the ability to use metadata to aid in interpretation of the data (understandability); and reusability. An improperly formulated standard format tends towards four disadvantages: (1) it can be inflexible and fail to allow the user to express his data as needed; (2) reading and writing such datasets can involve high overhead in computing time and storage space; (3) the format may be accessible only on certain machines using certain languages; and (4) under some circumstances it may be uncertain whether a given dataset actually conforms to the standard. A format was designed which enhances these advantages and lessens the disadvantages. The fundamental approach is to allow the user to make her own choices regarding strategic tradeoffs to achieve the performance desired in her local environment. The choices made are encoded in a specific and portable way in a set of records. A fully detailed description and specification of the format is given, and examples are used to illustrate various concepts. Implementation is discussed.

Lait, Leslie R.↗

Next generation optical instruments and space experiment based on the LDEF thermal control surfaces experiment (S0069)

The Thermal Control Surfaces Experiment (TCSE) was a successful experiment to study the effects of the space environment on thermal control surfaces using in-space optical properties measurements combined with post-flight analyses. The TCSE reflectometer performed well on the LDEF mission demonstrating that a portable compact integrating sphere spectroreflectometer can be built that is rugged and space rated. Since the retrieval of the TCSE package from space, several other instruments have evolved from its pioneering technologies. These are the Optical Properties Monitor (OPM), the Laboratory Portable SpectroReflectometer (LPSR), and the Space Portable SpectroReflectometer (SPSR). These instruments and experiment packages are described.

Wilkes, Donald R.↗

Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.↗

Monolithically interconnected GaAs solar cells: A new interconnection technology for high voltage solar cell output

Photovoltaic linear concentrator arrays can benefit from high performance solar cell technologies being developed at AstroPower. Specifically, these are the integration of thin GaAs solar cell and epitaxial lateral overgrowth technologies with the application of monolithically interconnected solar cell (MISC) techniques. This MISC array has several advantages which make it ideal for space concentrator systems. These are high system voltage, reliable low cost monolithically formed interconnections, design flexibility, costs that are independent of array voltage, and low power loss from shorts, opens, and impact damage. This concentrator solar cell will incorporate the benefits of light trapping by growing the device active layers over a low-cost, simple, PECVD deposited silicon/silicon dioxide Bragg reflector. The high voltage-low current output results in minimal 12R losses while properly designing the device allows for minimal shading and resistance losses. It is possible to obtain open circuit voltages as high as 67 volts/cm of solar cell length with existing technology. The projected power density for the high performance device is 5 kW/m for an AMO efficiency of 26% at 1 5X. Concentrator solar cell arrays are necessary to meet the power requirements of specific mission platforms and can supply high voltage power for electric propulsion systems. It is anticipated that the high efficiency, GaAs monolithically interconnected linear concentrator solar cell array will enjoy widespread application for space based solar power needs. Additional applications include remote man-portable or ultra-light unmanned air vehicle (UAV) power supplies where high power per area, high radiation hardness and a high bus voltage or low bus current are important. The monolithic approach has a number of inherent advantages, including reduced cost per interconnect and increased reliability of array connections. There is also a high potential for a large number of consumer products. Dual-use applications can include battery chargers and remote power supplies for consumer electronics products such as portable telephones/beepers, portable radios, CD players, dashboard radar detectors, remote walkway lighting, etc.

Dinetta, L. C.↗

Low profile antennas for MSAT applications

For MSAT applications, a number of different antennas have been designed and investigated. They include low gain omnidirectional antennas and medium gain to high gain directional antennas. The latter include both portable and vehicular antennas. While portable units are desirable to be low profile and low cost, the vehicular antennas have proved to be the most challenging antenna types for the mobile satellite application. The results of our efforts in design of such antennas are described briefly. Low profile designs are emphasized in most cases, and microstrip type radiators are therefore selected. The single radiator provides low gain omnidirectional patterns and is optimized for low cost applications. It provides low gains around 2-6 dBic and is useful mostly for the data transmission. Medium to high gain antennas are developed as arrays of omnidirectional elements. Again, different designs are optimized to meet the needs of different applications. For portable units, the array configuration can be flexible and is optimized for maximum broadside gains. For vehicular units, however the configurations are desirable to be low profile, or compact, and have means for scanning the antenna beam. For simplicity, fixed beam antennas with mechanical beam scan are selected. For these antennas, as well, different designs, having low profile or compact size, are selected and optimized to meet the MSAT gain and G/T requirements.

Shafai, L.↗

DITDOS: A set of design specifications for distributed data inventories

The analysis of space science data often requires researchers to work with many different types of data. For instance, correlative analysis can require data from multiple instruments on a single spacecraft, multiple spacecraft, and ground-based data. Typically, data from each source are available in a different format and have been written on a different type of computer, and so much effort must be spent to read the data and convert it to the computer and format that the researchers use in their analysis. The large and ever-growing amount of data and the large investment by the scientific community in software that require a specific data format make using standard data formats impractical. A format-independent approach to accessing and analyzing disparate data is key to being able to deliver data to a diverse community in a timely fashion. The system in use at the Planetary Plasma Interactions (PPI) node of the NASA Planetary Data System (PDS) is based on the object-oriented Distributed Inventory Tracking and Data Ordering Specification (DITDOS), which describes data inventories in a storage independent way. The specifications have been designed to make it possible to build DITDOS compliant inventories that can exist on portable media such as CD-ROM's. The portable media can be moved within a system, or from system to system, and still be used without modification. Several applications have been developed to work with DITDOS compliant data holdings. One is a windows-based client/server application, which helps guide the user in the selection of data. A user can select a data base, then a data set, then a specific data file, and then either order the data and receive it immediately if it is online or request that it be brought online if it is not. A user can also view data by any of the supported methods. DITDOS makes it possible to use already existing applications for data-specific actions, and this is done whenever possible. Another application is a stand-alone tool to assist in the extraction of data from portable media, such as CD-ROM's. In addition to the applications, there is a set of libraries that can facilitate building new DITDOS compliant applications.

King, T. A.↗