Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module degradation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Qualitative and quantitative profiles of jejunal oligosaccharides and cecal short–chain fatty acids in broiler chickens receiving different dietary levels of fiber, protein and exogenous enzymes

Dietary supplemental carbohydrases are able to degrade non-starch polysaccharides and generate oligosaccharides in the gastrointestinal tract. This study was conducted to investigate the influence of dietary fiber and protein levels on growth performance, nutrient utilization, digesta oligosaccharides profile and cecal short-chain fatty acid (SCFA) profile in broilers receiving diets supplemented with xylanase or protease individually or in combination. Enzyme supplementation had no effect on growth performance. There was significant (P < 0.05) fiber × protein × xylanase interaction for ileal nitrogen digestibility and significant (P < 0.01) protein × xylanase × protease interaction for nitrogen-corrected apparent metabolizable energy. Birds fed high-fiber diets had higher (P < 0.05) jejunal oligosaccharides and cecal SCFA concentrations. Xylanase and protease combination produced the greatest pentose (Pent) levels in low fiber–adequate protein diets but lowest levels in highfiber–low protein diets. There was significant (P < 0.05) fiber × xylanase × protease interaction explained by the digesta concentrations of (Pent) 3 , (Pent) 4 and (Pent) 5 being greatest (P < 0.5) in protease-only supplemented high-fiber diets but lowest in protease-only supplemented low-fiber diets. Furthermore, these results suggest that, of all the factors investigated, dietary fiber level had the greatest effect on modulating digesta concentration of oligosaccharides and cecal SCFA. Evidence points to the fact that there is considerable capacity for generating pentose oligosaccharides in the digestive tract of broilers receiving diets rich in fibrous feedstuffs, and that this may have a beneficial effect on microbial profile in the digestive tract.

59 BASIC BIOLOGICAL SCIENCES↗

Macromolecular Crowding Affects Voltage-Dependent Alamethicin Pore Formation in Lipid Bilayer Membranes

Macromolecular crowding is known to modulate chemical equilibria, reaction rates, and molecular binding events, both in aqueous solutions and at lipid bilayer membranes, natural barriers that enclose the crowded environments of cells and their subcellular compartments. Previous studies on the effects of macromolecular crowding in aqueous compartments on conduction through membranes have focused on single-channel ionic conduction through previously formed pores at thermodynamic equilibrium. Furthermore, the effects of macromolecular crowding on the mechanism of pore formation itself were studied using the droplet interface bilayer (DIB) technique with the voltage-dependent pore-forming peptide alamethicin (alm). Macromolecular crowding was varied using 8 kDa molecular weight polyethylene glycol (PEG8k) or 500 kDa dextran (DEX500k) in two aqueous droplets on both sides of the bilayer membrane. In general, voltage thresholds for pore formation in the presence of crowders in the droplets decreased compared to their values in the absence of crowders, due to excluded volume effects, water binding by PEG, and changes in the ordering of water molecules and hydrogen-bonding interactions involving the polar lipid headgroups. In addition, asymmetric crowder loading (e.g., PEG8k–DEX500k on either side of the membrane) resulted in transmembrane osmotic pressure gradients that either enhanced or degraded the ionic conduction through the pores.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accumulation of Dissolved DMSP by Marine Bacteria and its Degradation Via Bacterivory

Several bacterial isolates enriched from seawater using complex media were able to accumulate dimethylsulfoniopropionate (DMSP) from media into cells over several hours without degrading it. Uptake only occurred in metabolically active cells, and was repressed in some strains by the presence of additional carbon sources. Accumulation was also more rapid in osmotically-stressed cells, suggesting DMSP is used as an osmotic solute. Uptake could be blocked by inhibitors of active transport systems (2,4-dinitrophenol, azide, arsenate) and of protein synthesis (chloramphenicol). Some structural analogs such as glycine betaine and S-methyl methionine also blocked DMSP uptake, suggesting that the availability of alternate organic osmolytes may influence DMSP uptake. Stresses such as freezing, heating, or osmotic down shock resulted in partial release of DMSP back to the medium. One strain which contained a DMSP-lyase was also able to accumulate DMSP, and DMS was only produced in the absence of alternate carbon sources. Bacteria containing DMSP were prepared as prey for bacterivorous ciliates and flagellates, to examine the fate of the DMSP during grazing. In all cases, predators metabolized the DMSP in bacteria. In some cases, DMS was produced, but it is not clear if this was due to the predators or to associated bacteria in the non-axenic grazer cultures. Bacterivores may influence DMSP cycling by either modulating populations of DMSP-metabolizing bacteria, or by metabolizing DMSP accumulated by bacterial prey.

Wolfe, Gordon V.↗

The Exometabolome of Xylella fastidiosa in Contact with Paraburkholderia phytofirmans Supernatant Reveals Changes in Nicotinamide, Amino Acids, Biotin, and Plant Hormones

Microbial competition within plant tissues affects invading pathogens’ fitness. Metabolomics is a great tool for studying their biochemical interactions by identifying accumulated metabolites. Xylella fastidiosa, a Gram-negative bacterium causing Pierce’s disease (PD) in grapevines, secretes various virulence factors including cell wall-degrading enzymes, adhesion proteins, and quorum-sensing molecules. These factors, along with outer membrane vesicles, contribute to its pathogenicity. Previous studies demonstrated that co-inoculating X. fastidiosa with the Paraburkholderia phytofirmans strain PsJN suppressed PD symptoms. Here, we further investigated the interaction between the phytopathogen and the endophyte by analyzing the exometabolome of wild-type X. fastidiosa and a diffusible signaling factor (DSF) mutant lacking quorum sensing, cultivated with 20% P. phytofirmans spent media. Liquid chromatography–mass spectrometry (LC-MS) and the Method for Metabolite Annotation and Gene Integration (MAGI) were used to detect and map metabolites to genomes, revealing a total of 121 metabolites, of which 25 were further investigated. These metabolites potentially relate to host adaptation, virulence, and pathogenicity. Notably, this study presents the first comprehensive profile of X. fastidiosa in the presence of a P. phytofirmans spent media. The results highlight that P. phytofirmans and the absence of functional quorum sensing affect the ratios of glutamine to glutamate (Gln:Glu) in X. fastidiosa. Additionally, two compounds with plant metabolism and growth properties, 2-aminoisobutyric acid and gibberellic acid, were downregulated when X. fastidiosa interacted with P. phytofirmans. These findings suggest that P. phytofirmans-mediated disease suppression involves modulation of the exometabolome of X. fastidiosa, impacting plant immunity.

60 APPLIED LIFE SCIENCES↗

Nitrogen-doped graphene nanomaterials for electrochemical catalysis/reactions: A review on chemical structures and stability

The electronic structure of the carbon-based nanomaterials can be modulated by doping heteroatoms into them. When nitrogen is doped into the graphene structure with different bonding configurations, it changes the material's electronic properties in a variety of ways. Because of the tuned electronic properties, nitrogen-doped graphene (N-G) is applicable in electrochemical systems as catalyst. Despite having tremendous prospects, a holistic view of the structural and functional properties of N-G is still unclear. Moreover, to our knowledge, significant findings on the properties of N-G are not well documented yet, which creates an obstacle to the further improvement of this nanomaterial. Keeping our focus on the catalytic activities, in this paper, we presented an in-detailed review of the overall chemical structure and functional properties of N-G nanomaterials. Starting from the structural properties of major precursor materials for N-G synthesis, we reviewed the physical features and its dependence on the synthesis parameters. Also, a detailed study has been conducted on the key nitrogen functional groups' structural properties, favorable formation environment, influence on the electronic structure of N-G, and role in the catalytic activity. Finally, current progress on the stability of N-G nanocatalysts is reported with an insight into the degradation mechanism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Microbiologically Influenced Corrosion Potential in the International Space Station Internal Active Thermal Control System Heat Exchanger Materials: A 6-Momths Study

The fluid in the Internal Active Thermal Control System (IATCS) of the International Space Station (ISS) is water based. The fluid in the ISS Laboratory Module and Node 1 initially contained a mix of water, phosphate (corrosion control), borate (pH buffer), and silver sulfate (Ag2SO4) (microbial control) at a pH of 9.5+/-0.5. Over time, the chemistry of the fluid changed. Fluid changes included a pH drop from 9.5 to 8.3 due to diffusion of carbon dioxide (CO2) through Teflon(reistered Trademark) (DuPont) hoses, increases in dissolved nickel (Ni) levels, deposition of silver (Ag) to metal surfaces, and precipitation of the phosphate (PO4) as nickel phosphate (NiPO4). The drop in pH and unavailability of a antimicrobial has provided an environment conducive to microbial growth. Microbial levels in the fluid have increased from >10 colony-forming units (CFUs)/100 ml to 10(exp 6) CFUs/100 ml. The heat exchangers in the IATCS loops are considered the weakest point in the loop because of the material thickness (=7 mil). It is made of a Ni-based braze filler/CRES 347. Results of a preliminary test performed at Hamilton Sundstrand indicated the possibility of pitting on this material at locations where Ag deposits were found. Later, tests have confirmed that chemical corrosion of the materials is a concern for this system. Accumulation of micro-organisms on surfaces (biofilm) can also result in material degradation and can amplify the damage caused by the chemical corrosion, known as microbiologically influenced corrosion (MIC). This paper will discuss the results of a 6-mo test performed to characterize and quantify the damage from microbial accumulation on the surface of the ISS/ATCS heat exchanger materials. The test was designed to quantify the damage to the materials under worst-case conditions with and without micro-organisms present at pH 8.3 and 9.5.

Roman, Monsi C.↗

Performance Comparison of Wireless Sensor Network Standard Protocols in an Aerospace Environment: ISA100.11a and ZigBee

Wireless Sensor Networks (WSNs) can provide a substantial benefit in spacecraft systems, reducing launch weight and providing unprecedented flexibility by allowing instrumentation capabilities to grow and change over time. Achieving data transport reliability on par with that of wired systems, however, can prove extremely challenging in practice. Fortunately, much progress has been made in developing standard WSN radio protocols for applications from non-critical home automation to mission-critical industrial process control. The relative performances of candidate protocols must be compared in representative aerospace environments, however, to determine their suitability for spaceflight applications. In this paper, we will present the results of a rigorous laboratory analysis of the performance of two standards-based, low power, low data rate WSN protocols: ZigBee Pro and ISA100.11a. Both are based on IEEE 802.15.4 and augment that standard's specifications to build complete, multi-hop networking stacks. ZigBee Pro targets primarily the home and office automation markets, providing an ad-hoc protocol that is computationally lightweight and easy to implement in inexpensive system-on-a-chip components. As a result of this simplicity, however, ZigBee Pro can be susceptible to radio frequency (RF) interference. ISA100.11a, on the other hand, targets the industrial process control market, providing a robust, centrally-managed protocol capable of tolerating a significant amount of RF interference. To achieve these gains, a coordinated channel hopping mechanism is employed, which entails a greater computational complexity than ZigBee and requires more sophisticated and costly hardware. To guide future aerospace deployments, we must understand how well these standards relatively perform in analog environments under expected operating conditions. Specifically, we are interested in evaluating goodput -- application level throughput -- in a representative crewed environment in the presence of varying levels of 802.11g Wi-Fi traffic. To do so, we use the NASA Johnson Space Center Wireless Habitat Testbed (WHT), a metallic, habitation-sized module designed for co-existence testing of wireless systems. In its quiescent state, the sealed WHT provides an RF-quiet environment to which we can selectively add interfering systems; it also provides a realistic level of multi-path self-interference for systems under investigation. In our test, we deploy two representative five node networks, configured in a star topology with all nodes reporting directly to a WSN gateway. Each ZigBee network WSN node is built using a Texas Instruments (TI) CC2530 system-on-a-chip radio running TI's ZigBee Pro Z-stack. Each ISA100.11a network node is built using a Nivis VersaNode 210 system-on-a-chip radio. In both cases, radios interface with TI MSP430-F5438 microcontroller implementing a common test application. Interference is provided by a D-link 802.11g Wi-Fi router transporting traffic generated using the Iperf network testing tool. For the single-channel ZigBee network, effects of both direct and indirect Wi-Fi interference are evaluated. For the channel-hopping ISA100.11a network, effects of interference from multiple Wi-Fi routers configured in non-overlapping 802.11g channels are evaluated. Our results show that, in general, the more lightweight ZigBee network performs well at low interference levels, but performance degrades as interference increases. Conversely, the more complex and costly ISA100.11a network continues to perform well as Wi-Fi interference levels increase.

Wagner, Raymond S.↗

Thermobifida fusca Cel6B moves bidirectionally while processively degrading cellulose

Abstract Background Cellulose, an abundant biopolymer, has great potential to be utilized as a renewable fuel feedstock through its enzymatic degradation into soluble sugars followed by sugar fermentation into liquid biofuels. However, crystalline cellulose is highly resistant to hydrolysis, thus industrial-scale production of cellulosic biofuels has been cost-prohibitive to date. Mechanistic studies of enzymes that break down cellulose, called cellulases, are necessary to improve and adapt such biocatalysts for implementation in biofuel production processes. Thermobifida fusca Cel6B ( Tf Cel6B) is a promising candidate for industrial use due to its thermostability and insensitivity to pH changes. However, mechanistic studies probing Tf Cel6B hydrolytic activity have been limited to ensemble-scale measurements. Results We utilized optical tweezers to perform single-molecule, nanometer-scale measurements of enzyme displacement during cellulose hydrolysis by Tf Cel6B. Records featured forward motility on the order of 0.17 nm s −1 interrupted by backward motions and long pauses. Processive run lengths were on the order of 5 nm in both forward and backward directions. Motility records also showed rapid bidirectional displacements greater than 5 nm. Single-enzyme velocity and bulk ensemble activity were assayed on multiple crystalline cellulose allomorphs revealing that the degree of crystallinity and hydrogen bonding have disparate effects on the single-molecule level compared to the bulk scale. Additionally, we isolated and monitored the catalytic domain of Tf Cel6B and observed a reduction in velocity compared to the full-length enzyme that includes the carbohydrate-binding module. Applied force has little impact on enzyme velocity yet it readily facilitates dissociation from cellulose. Preliminary measurements at elevated temperatures indicated enzyme velocity strongly increases with temperature. Conclusions The unexpected motility patterns of Tf Cel6B are likely due to previously unknown mechanisms of processive cellulase motility implicating irregularities in cellulose substrate ultrastructure. While Tf Cel6B is processive, it has low motility at room temperature. Factors that most dramatically impact enzyme velocity are temperature and the presence of its native carbohydrate-binding module and linker. In contrast, substrate ultrastructure and applied force did not greatly impact velocity. These findings motivate further study of Tf Cel6B for its engineering and potential implementation in industrial processes.

Johnson, Madeline M. (ORCID:000000029518293X)↗

Corrosion of novel reactive silver ink and commercial silver-based metallizations in diluted acetic acid

Silver-based metallizations in photovoltaic modules are susceptible to corrosion by acetic acid generated in ethylene vinyl acetate encapsulated modules, resulting in power losses over time. Here, three silver-based metallizations are exposed to diluted acetic acid, in concentrations representative of that found in field-exposed modules. Compositional, morphological, and structural changes of the metallizations are studied over 3000 h of exposure to diluted acetic acid using Raman spectroscopy mapping, X-ray diffraction, and scanning electron microscopy. The three metallizations studied are: 1) a commercial high-temperature fire-through Ag paste, commonly used for Si diffused junction solar cells; 2) a commercial low-temperature paste normally used for silicon heterojunction cells; and 3) a novel low-temperature reactive silver ink shown to be suitable for photovoltaic applications. We find distinct corrosion rates for the high-temperature silver paste and reactive silver ink in the presence of diluted acetic acid. However, the low-temperature silver paste appears to be more corrosion resistant, likely due to a polymer layer that protects the silver particles.

36 MATERIALS SCIENCE↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Rapid Characterization and Statistical Analysis of High-Volume Field-Harvested Photovoltaic Connectors

Photovoltaic (PV) installations heavily depend on connectors for efficient module and string interconnections without requiring skilled labor. Yet this seemingly innocuous component of PV systems is a leading cause of module failures, multiple high-profile fires, and lawsuits in the PV industry. This work aims to answer critical questions regarding why connectors fail and the contributing factors to their failure. The study involves collecting and analyzing more than 17,000 field-harvested connectors from various solar installations across the United States. The vast dataset, which includes connector metadata, visual inspections, and resistance measurements, provides unprecedented insight into the state of health of PV connectors across the US, including the geographic locations, connector types, and installation practices most prone to failures. The work presented here describes a novel rapid characterization method for processing large numbers of connectors and is supported by parallel forensic analysis to discern the root causes of failures as well as a levelized cost of lifetime model to determine the economic ramifications of connector failure. Ultimately, the findings may inform PV developers about the best practices to extend connector longevity and lead to more resilient and reliable PV systems.

connectors↗

Effects of Heating Configuration and Operating Parameters on Heat Transfer and Interfacial Physics of Microgravity Flow Boiling With Subcooled Inlet Conditions –Experiments Onboard the International Space Station

This study is part of the Flow Boiling and Condensation Experiment (FBCE), a collaborative effort between the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center. The FBCE fitted with the Flow Boiling Module (FBM) was launched to the International Space Station (ISS) in August 2021 and experiments were successfully performed from February to July 2022 to amass a large microgravity-flow-boiling database. This study is focused on heat transfer and flow visualization of microgravity flow boiling of n-Perfluorohexane in a rectangular channel of 5.0 mm height, 2.5 mm width (heated), and 114.6 mm length, with subcooled inlet conditions. High-speed-video photography is utilized to present flow patterns and temporal interfacial behavior. Heat transfer results are presented in the form of flow boiling curves and both parametric curves and streamwise profiles of wall temperature and heat transfer coefficient. Firstly, the parametric effects of mass velocity (199.4 – 3200.0 kg/m 2 s), inlet subcooling (0.2 – 46.0°C), and inlet pressure (124.2 – 176.7 kPa), on the aforementioned aspects are assessed for double-sided heating to establish them for a microgravity environment. Of these three parameters, mass velocity and inlet subcooling mostly determine the microgravity flow boiling behavior, while inlet pressure plays an insignificant role. Flow patterns for double-sided heating are more complex than those for single-sided heating due to interaction between the two vapor layers. Vapor interaction is minimized at high subcoolings and high mass velocities due to strong condensation offered by the subcooled bulk liquid layer separating them. Despite the different flow patterns, both single- and double-sided heating generally result in similar parametric trends and local heat transfer coefficients for similar operating conditions. Flow instabilities manifest as temporal flow anomalies and temperature oscillations, and their severity increases with increasing boiling number. Secondly, the effects of heating configuration are analyzed by comparing and contrasting several aspects of single- and double-sided heating data. The heat fluxes at which onset of nucleate boiling degradation (ONBD) and critical heat flux (CHF) occur are distinctly different for single- and double-sided heating. There exists a threshold inlet subcooling demarcating the dominance of flow acceleration and condensation effects in vapor removal from the near-wall region and replenishment of fresh liquid for boiling. Above the threshold, condensation from the near-wall region is dominant and single-sided heating yields higher heat fluxes, and below it, acceleration is dominant and double-sided yields higher heat fluxes. At mass velocity in the range of 200 – 2400 kg/m 2 s, the threshold inlet subcooling lies in the approximate range of 20 – 30°C (corresponding inlet quality of roughly -0.40 – -0.20).

Microgravity↗

SIW21-95: Hybridizing Synchronous Condensers with Grid-Forming Battery Energy Storage Systems

One of the main challenges associated with deployment of high shares of inverter-based resources (IBRs) in power grid is not only reduced system inertia but also degrading system strength that may cause severe stability impacts. A minimum level of system strength is needed for the power system to remain stable under normal conditions and to return to a steady state condition following a system disturbance. Significant system strength reduction is expected in almost all planned areas for solar and wind generation deployment. Synchronous condensers (SC) have been considered as one main technology to address the system strength issues for the areas with high levels of IBRs. SCs can help improving reliability and resiliency of power system but they do not provide the full range of services needed by power systems for reliable and economic integration of high shares of inverter-coupled variable generation such as PV generation. Services related to active power controls cannot be provided by SCs due to lack of prime mover. Even for provision of reactive power SCs have certain constraints based on their thermal and stability limits. NREL has been conducting research on a hybridized concept that combines SCs with grid forming (GFM) battery energy storage systems (BESS). This super flexible AC transmission system (SuperFACTS) that combines these two technologies in a single plant under the same controller offers a unique scalable set of services to the power system at all levels (transmission, sub-transmission, distribution, islands and isolated microgrids). Depending on use cases, SuperFACTS can be controlled to provide fully dispatchable and flexible operation using energy storage component, provide a full range of existing and future ancillary and reliability services to the grid (similar or better than conventional sources), maintain adequate levels of grid strength and inertia, and provide fault current for proper operation of protection systems. Therefore, this economic and easy to commercialize solution has potential for significant impacts on certain segments of global energy sector. All types of gird services (market based, reliability and resiliency) can be provided by SuperFACTS plants. GFM BESS can act as a self-black start source for each SuperFACTS module, which in turn can act a black start resource for co-located PV and wind power plants, segments of transmission and distribution networks, for conventional power plants, etc. The issue of in-rush currents during black start is addressed by overcurrent capability of SCs. In this paper we describe the results of modeling for SuperFACTS concept.

grid forming↗

Jitter Controller Software

Sinusoidal jitter is produced by simply modulating a clock frequency sinusoidally with a given frequency and amplitude. But this can be expressed as phase jitter, frequency jitter, or cycle-to-cycle jitter, rms or peak, absolute units, or normalized to the base clock frequency. Jitter using other waveforms requires calculating and downloading these waveforms to an arbitrary waveform generator, and helping the user manage relationships among phase jitter crest factor, frequency jitter crest factor, and cycle-to-cycle jitter (CCJ) crest factor. Software was developed for managing these relationships, automatically configuring the generator, and saving test results documentation. Tighter management of clock jitter and jitter sensitivity is required by new codes that further extend the already high performance of space communication links, completely correcting symbol error rates higher than 10 percent, and therefore typically requiring demodulation and symbol synchronization hardware to operating at signal-to-noise ratios of less than one. To accomplish this, greater demands are also made on transmitter performance, and measurement techniques are needed to confirm performance. It was discovered early that sinusoidal jitter can be stepped on a grid such that one can connect points by constant phase jitter, constant frequency jitter, or constant cycle-cycle jitter. The tool automates adherence to a grid while also allowing adjustments off-grid. Also, the jitter can be set by the user on any dimension and the others are calculated. The calculations are all recorded, allowing the data to be rapidly plotted or re-plotted against different interpretations just by changing pointers to columns. A key advantage is taking data on a carefully controlled grid, which allowed a single data set to be post-analyzed many different ways. Another innovation was building a software tool to provide very tight coupling between the generator and the recorded data product, and the operator's worksheet. Together, these allowed the operator to sweep the jitter stimulus quickly along any of three dimensions and focus on the response of the system under test (response was jitter transfer ratio, or performance degradation to the symbol or codeword error rate). Additionally, managing multi-tone and noise waveforms automated a tedious manual process, and provided almost instantaneous decision- making control over test flow. The code was written in LabVIEW, and calls Agilent instrument drivers to write to the generator hardware.

Lansdowne, Chatwin↗

Microgravity Flow Boiling Experiments With Liquid-Vapor Mixture Inlet Onboard the International Space Station

This article is part of a series of studies culminating from the multi-objective Flow Boiling and Condensation Experiment (FBCE) onboard the International Space Station, which utilized the Flow Boiling Module (FBM) for experiments between February and July 2022. This study investigates microgravity flow boiling of n-Perfluorohexane with liquid-vapor mixture (two-phase) inlet conditions to the FBM with either one or two opposite walls heated. The FBM’s channel has a rectangular cross-sectional area of 5.0 × 2.5 mm 2 and a heated length of 114.6 mm. Key parameters of interest include mass velocity (180 – 2400 kg/m 2 s), inlet quality (-0.01 – 0.87), inlet pressure (120 – 200 kPa), and heat flux (1.8 W/cm 2 to critical heat flux), and a large database is amassed. The flow is visualized via a high-speed video camera and photographs are recorded at each heating increment to assess the periodic flow patterns within the channel and the near-wall interfacial behavior. Flow patterns are complex and mainly characterized by high- and low-density fronts alternately traversing the channel to yield high- and low-density-dominant periods of boiling. At all operating conditions, high-density fronts are faster during high-density-dominant periods. At low inlet qualities, the flow is annular near the channel inlet with a central vapor core surrounded by an annular liquid layer. Each high-density front having a high liquid fraction leaves a thin liquid layer sheared onto the heated walls. Boiling occurs within the liquid layer and a vapor layer is formed next to the heated wall. Inlet quality and mass velocity most dictate the overall flow patterns followed by heating configuration, and to a much lesser extent, heat flux and inlet pressure. Heat transfer characteristics are assessed via averaged boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric curves of local and averaged heat transfer coefficients. Inlet pressure has an insignificant effect on heat transfer. At similar operating conditions, both the heating configurations yield similar trends and values of heat transfer coefficient and critical heat flux (CHF, slightly higher for single-sided) even though double-sided heating adds twice the heat to the fluid and doubly raises local quality. The heat fluxes required for both onset of nucleate boiling degradation and CHF are larger at high mass velocities and low inlet qualities. For a fixed inlet quality, high mass velocities yield higher average heat transfer coefficients at both lower and higher heat fluxes, while the nucleate boiling regime at intermediate heat fluxes is unaffected. For a fixed mass velocity, higher inlet qualities yield higher and lower average heat transfer coefficients at lower and higher heat fluxes, respectively.

Microgravity↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Ultraviolet Fluorescence Imaging for Photovoltaic Module Metrology: Best Practices and Survey of Features Observed in Fielded Modules

As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.

14 SOLAR ENERGY↗