Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

End-wall boundary layer measurements in a two-stage fan

Detailed flow measurements made in the casing boundary layer of a two-stage transonic fan are summarized. These measurements were taken at stations upstream of the fan, between all blade rows, and downstream of the last blade row. At the design tip speed of 429 m/sec the fan achieved a peak efficiency of 0.846 at a pressure ratio of 2.471. The boundary layer data were obtained at three weight flows at the design speed: one near choke flow, one near peak efficiency, and one near stall. Conventional boundary layer parameters were calculated from the data measured at each measuring station for each of the three flows. A classical two dimensional casing boundary layer was measured at the fan inlet and extended inward to approximately 15 percent of span. A highly three dimensional boundary layer was measured at the exit of each blade row and extended inward to approximately 10 percent of span. The steep radial gradient of axial velocity noted at the exit of the rotors was reduced substantially as the flow passed through the stators. This reduced gradient is attributed to flow mixing. The amount of flow mixing was reflected in the radial redistribution of total temperature as the flow passed through the stators. The data also show overturning of the tip flow at the stator exits that is consistent with the expected effect of the secondary flow field. The blockage factors calculated from the measured data show an increase in blockage across the rotors and a decrease across the stators.

Ball, C. L.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub e calculated from measured plasma conductivity. Additional measurements of n sub e as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Measurement of high temperature strain by the laser-speckle strain gauge

By using the laser-speckle strain gauge, the strain of metal at the temperature lower than 250 C is measured. The principle of the gauge is to measure the expansion or contraction of the fine structures of surface by detecting the resultant speckle displacement in an optoelectronic way, whereby the effect of rigid-body motion is automatically cancelled out with the aid of a differential detection system. A transportable apparatus was built and a comparison experiment performed with a resistance strain gauge at room temperature. It has a strain sensitivity of .00002, a gauge length smaller than 1 mm, and no upper limit in a range of strain measurement. In the measurement of high-temperature strain it is free from the need for a dummy gauge and insensitive to an electric drift effect. As examples of strain measurement at high-temperature, thermal expansion and contraction of a top of a soldering iron are measured. The interval of the measurement can be made at shortest 1.6 sec. and the change in the strain is clearly followed until the ultimate stationary temperature is reached.

Yamaguchi, I.↗

Measurement of the Vertical Gradient of the Semidiurnal Tidal Wind Phase in Winter at the 95 Km Level

When supplemented by absolute reflection height measurements, low frequency wind measurements in the 90-100 km height range become truly competitive in comparison with the more widely used radar meteor wind observations. For example, height profiles of the wind parameters in the so-called meteor zone can be obtained due to the considerable interdiurnal variability of the average nighttime reflection heights controlled by geomagnetic activity. The phase of the semidiurnal tidal wind is particularly height-dependent. The measured vertical gradient of 1/4 h/km in winter corresponds to a vertical wavelength of about 50 km. Wind measurements in the upper atmosphere, at heights between 90 and 100 km, were carried out at the Collm Geophysical Observatory of Karl Marx University Leipzig for a number of years. These measurements use the closely-spaced receiver method and three measuring paths, on 179, 227, and 272 kHz. They take place every day between sunset and sunrise, i.e., nightly. A night in this sense may last as long as 18 hours in winter. Both the measurements and their evaluation are completely automatic, and the prevailing winds and tides are separated.

Schminder, R.↗

Measured microwave emission and scattering in vegetation canopies

Reflecting metal screens were placed beneath vegetation of three types to allow measurement of the brightness temperature of the vegetation cover alone. A two-frequency radiometer (wavelengths: 11.1 and 5.88 cm) was used to measure the emission from the vegetation, and a theoretical model involving a loss term and a scattering albedo was fitted to the measured temperatures. Passive and active microwave measurements were also made on fields immediately adjacent to the 'screened' fields. Emission and backscattering were measured for these fields under two conditions: with full vegetation cover, and with vegetation removed. Using the same theoretical model and the calculated values for absorption and scattering derived from the screened fields, the effect of the vegetation cover on the soil emission was predicted. The predicted full-canopy temperatures were then compared to those measured. The values for loss and scattering in the vegetation canopy were used in another model to predict the effect of vegetation on backscattering from the soil surface. Again, the predicted backscattering from the vegetation canopy was compared with the measured values of the backscattering coefficient.

Brunfeldt, D. R.↗

On the measurement of pilot perceptual workload - A comparison of assessment techniques addressing sensitivity and intrusion issues

A flight simulator-based study was conducted to examine fourteen distinct mental workload estimation measures, including opinion, secondary task, physiological, and primary task measures. Both the relative sensitivity of the measures to changes in mental workload and the differential intrusion of the changes on primary task performance were assessed. The flight task was varied in difficulty by manipulation of the presentation rate and complexity of a hazard-perception task that required each of 48 licensed pilots to rely heavily on their perceptual abilities. Three rating scales (Modified Cooper-Harper, Multi-descriptor, and Workload-Compensation-Interference/Technical Effectiveness), two secondary task measures (time estimation and tapping regularity), one physiological measure (respiration frequency), and one primary task measure (danger-condition response time) were reliable indicants of workload changes. Recommendations for applying the workload measures are presented.

Casali, J. G.↗

Far-field patterns of spaceborne antennas from plane-polar near-field measurements

Certain unique features of a recently constructed plane-polar near-field measurement facility for determining the far-field patterns of large and fragile spaceborne antennas are described. In this facility, the horizontally positioned antenna rotates about its axis while the measuring probe is advanced incrementally in a fixed radial direction. The near-field measured data is then processed using a Jacobi-Bessel expansion to obtain the antenna far fields. A summary of the measurement and computational steps is given. Comparisons between the outdoor far-field measurements and the constructed far-field patterns from the near-field measured data are provided for different antenna sizes and frequencies. Application of the substitution method for the absolute gain measurement is discussed. In particular, results are shown for the 4.8-m mesh-deployable high-gain antenna of the Galileo spacecraft which has the mission of orbiting Jupiter in 1988.

Rahmat-Samii, Y.↗

Mobile VLBI and GPS measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, P. M.↗

Measurements of Siple transmitter signals on the DE 1 satellite - Wave normal direction and antenna effective length

A new experimental technique is developed to simultaneously measure the wave propagation direction and the effective length of a small (L value much smaller than wavelength) electric dipole antenna on a spin-stabilized satellite in the magnetosphere. The technique relies on the near simultaneous measurement of single components of the electric and magnetic fields of a coherent VLF signal injected into the medium from a ground-based source. The spin fading characteristics of the signal received by the electric dipole and the magnetic loop antenna permit the measurement of the wave normal direction assuming whistler-mode propagation. In-situ and remote measurements of the local cold plasma density are used to determine the refractive index. The wave electric field is then inferred from the wave magnetic field as measured on the loop antenna, the refractive index and the direction of propagation. Comparing this electric field with the measured voltage across the dipole antenna leads to the determination of the effective length of the receiving electric dipole. The technique is applied to data from the Dynamics Explorer 1 satellite observations of whistler mode signals injected into the magnetosphere from the Siple, Antarctica, VLF transmitter. In one case, with the measured background cold plasma density being 15 el/cu cm, the effective length of the 200 m-long electric dipole antenna is found to be 222 + or - 56 m, i.e., about twice the conventional value.

Sonwalker, V. S.↗

Evaluation of 16 measures of mental workload using a simulated flight task emphasizing mediational activity

As aircraft and other systems become more automated, a shift is occurring in human operator participation in these systems. This shift is away from manual control and toward activities that tap the higher mental functioning of human operators. Therefore, an experiment was performed in a moving-base flight simulator to assess mediational (cognitive) workload measurement. Specifically, 16 workload estimation techniques were evaluated as to their sensitivity and intrusion in a flight task emphasizing mediational behavior. Task loading, using navigation problems presented on a display, was treated as an independent variable, and workload-measure values were treated as dependent variables. Results indicate that two mediational task measures, two rating scale measures, time estimation, and two eye behavior measures were reliably sensitive to mediational loading. The time estimation measure did, however, intrude on mediational task performance. Several of the remaining measures were completely insensitive to mediational load.

Wierwille, W. W.↗

An information measure for class discrimination

This article describes a separability measure for class discrimination. This measure is based on the Fisher information measure for estimating the mixing proportion of two classes. The Fisher information measure not only provides a means to assess quantitatively the information content in the features for separating classes, but also gives the lower bound for the variance of any unbiased estimate of the mixing proportion based on observations of the features. Unlike most commonly used separability measures, this measure is not dependent on the form of the probability distribution of the features and does not imply a specific estimation procedure. This is important because the probability distribution function that describes the data for a given class does not have simple analytic forms, such as a Gaussian. Results of applying this measure to compare the information content provided by three Landsat-derived feature vectors for the purpose of separating small grains from other crops are presented.

Shen, S. S.↗

Field experiment for measurement of the radiative characteristics of a hazy atmosphere

Theoretical two-dimensional and three-dimensional solutions to the radiative-transfer equation have been applied to the earth-atmosphere system. A field experiment was conducted to test this theory. In the experiment the upward radiance was measured above and below a haze layer during simultaneous measurements of the haze characteristics. The measurements were conducted at a narrow near-IR channel (773 + or - 22 nm) which represents the visible and near-IR spectral region. The aerosol vertical optical thickness at eight wavelengths, as well as the vertical and horizontal profiles of the scattering coefficient, the temperature, and dew point were measured at several locations. These measurements quantified the vertical and spatial structure of the atmospheric haze and the atmospheric radiation. The result was a well-defined radiative-transfer experiment. The experimental data set is used to quantify the haze effect on upward radiance, including the adjacency effect (the effect of a bright area on the upward radiance measured above a dark adjacent area), and to test radiative-transfer models for a plane-parallel atmosphere above a nonuniform surface. A comparison is given between the theoretical prediction of upward radiance above the haze and the measurement. Agreement between theory and the experiment is discussed.

Kaufman, Y. J.↗

Improved solution of the lidar equation utilizing particle counter measurements

The extraction of particle backscattering from incoherent lidar measurements poses some problems. In the case of measurements of the stratospheric aerosol layer the solution of the lidar equation is based on two assumptions which are necessary to normalize the measured signal and to correct it with the two-way transmission of the laser pulse. Normalization and transmission are tackled by adding the information contained in aerosol particle counter measurements of the University of Wyoming to the ruby lidar measurements at Garmisch-Partenkirchen. Calculated backscattering from height levels above 25 km for the El Chichon period will be compared with lidar measurements and necessary corrections. The calculated backscatter-to-extinction ratios are compared to those, which were derived from a comparison of published extinction values to measured lidar backscattering at Garmisch. These ratios were used to calculate the Garmisch lidar returns. For the period 4 to 12 months after the El Chichon eruption a backscater-to-extinction ratio of 0.026 1/sr was applied with smaller values before and after that time.

Jaeger, H.↗

Combustion noise from gas turbine aircraft engines measurement of far-field levels

Combustion noise can be a significant contributor to total aircraft noise. Measurement of combustion noise is made difficult by the fact that both jet noise and combustion noise exhibit broadband spectra and peak in the same frequency range. Since in-flight reduction of jet noise is greater than that of combustion noise, the latter can be a major contributor to the in-flight noise of an aircraft but will be less evident, and more difficult to measure, under static conditions. Several methods for measuring the far-field combustion noise of aircraft engines are discussed in this paper. These methods make it possible to measure combustion noise levels even in situations where other noise sources, such as jet noise, dominate. Measured far-field combustion noise levels for several turbofan engines are presented. These levels were obtained using a method referred to as three-signal coherence, requiring that fluctuating pressures be measured at two locations within the engine core in addition to the far-field noise measurement. Cross-spectra are used to separate the far-field combustion noise from far-field noise due to other sources. Spectra and directivities are presented. Comparisons with existing combustion noise predictions are made.

Krejsa, Eugene A.↗

Containerless high temperature property measurements by atomic fluorescence

Containerless high temperature processing and material property measurements are discussed. Researchers developed methods for non-contact suspension, heating, and property measurement for materials at temperatures up to 3,680K, the melting point of tungsten. New, scientifically interesting results were obtained in Earth-based research. These results and the demonstration of new methods and techniques form a basis for further advances under the low gravity environment of space where containerless conditions are more easily achieved. Containerless high temperature material property investigations that have been completed in this and our earlier projects include measurements of fluorine LaB sub 6 reaction kinetics at 1,000 to 1,500K; optical property measurements on sapphire (Al2O3) at temperatures up to the melting point (2,327K); and vapor pressure measurements for LaB sub 6 at 2,000 to 2,500K, for molybdenum up to 2,890K and for tungsten up to 3,680K. Gas jet levitation which is applicable to any solid material, and electromagnetic levitation of electrical conductors were used to suspend the materials of interest. Non-contact heating and property measurements were achieved by optical techniques, i.e., laser heating, laser induced fluorescence measurements of vapor concentrations, and optical pyrometry for specimen temperatures.

Nordine, Paul C.↗

The split-cross-bridge resistor for measuring the sheet resistance, linewidth, and line spacing of conducting layers

A new test structure was developed for evaluating the line spacing between conductors on the same layer using an electrical measurement technique. This compact structure can also be used to measure the sheet resistance, linewidth, and line pitch of the conducting layer. Using an integrated-circuit fabrication process, this structure was fabricated in diffused polycrystalline silicon and metal layers and measured optically and electrically. For the techniques used, the optical measurements were typically one-quarter micron greater than the electrical measurements. Most electrically measured line pitch values were within 2 percent of the designed value. A small difference between the measured and designed line pitch is used to validate sheet resistance, linewidth, and line spacing values.

Buehler, M. G.↗

Mobile very long baseline interferometry and Global Positioning System measurement of vertical crustal motion

Mobile Very Long Base Interferometry (VLBI) and Global Positioning System (GPS) geodetic measurements have many error sources in common. Calibration of the effects of water vapor on signal transmission through the atmosphere, however, remains the primary limitation to the accuracy of vertical crustal motion measurements made by either technique. The two primary methods of water vapor calibration currently in use for mobile VLBI baseline measurements were evaluated: radiometric measurements of the sky brightness near the 22 GHz emission line of free water molecules and surface meteorological measurements used as input to an atmospheric model. Based upon a limited set of 9 baselines, it is shown that calibrating VLBI data with water vapor radiometer measurements provides a significantly better fit to the theoretical decay model than calibrating the same data with surface meteorological measurements. The effect of estimating a systematic error in the surface meteorological calibration is shown to improve the consistency of the vertical baseline components obtained by the two calibration methods. A detailed error model for the vertical baseline components obtained indicates current mobile VLBI technology should allow accuracies of order 3 cm with WVR calibration and 10 cm when surface meteorological calibration is used.

Kroger, Peter M.↗