Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “maximize”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Conversion of Coal Wastes and Coal Plus Other Opportunity Fuel Mixtures, Such as Coal Plus Municipal Solids, to Produce Electricity and/or Liquid Fuels

For the foreseeable future, the Nation’s energy demand will continue to come largely from indigenous fossil energy resources and hydrocarbon fuels. Specifically waste coal plus other opportunity fuels need to be utilized as a feedstock to eliminate a waste stream and optimized to maximize energy yield and cleanly minimize pollutant emissions. Modular equipment is needed for installation in coal preparation locations, military installations, and research park facilities. Thermal decomposition of coal, biomass, and mixed solid waste (MSW) have been shown to reduce a waste stream while providing liquid and gaseous fuel products with low pollutant emissions. However, thermal decomposition processes have several challenges associated with preprocessing biomass and MSW, feeding and conveying material into the reactor, and post processing of syngas to remove undesirable products while upgrading to increase yield of high value products. Increasing total energy output from power plants by utilizing biomass and mixed wastes ultimately lowers energy costs, harmful environmental impacts of emissions, and has significant impacts on the energy security and sustainability of the U.S. economy. Entrained flow gasifiers (EFGs) produce very little CH4 and a wide range of H2/CO ratios (0.5–2.0) but are limited in their ability to effectively feed large biomass or MSW particles into the reactor. A solution to the feeding problems is to use pyrolysis torrefaction (PT) for conversion of waste materials to create a feedstock similar to coal and capable of grinding down and mixing with the coal feed. Mainstream experimentally explored reaction pathways for the conversion of coal waste plus municipal solids (CWPMS) and demonstrated a bench-scale reactor used for torrefaction of the municipal solid waste (MSW) to create a coal-like feed for blending with the coal waste. The material was processed in a pilot-scale EFG to determine product yield and emissions with CWPMS fuels, as well as the ash content and slagging properties of these feedstocks. The PT-EFG system was experimentally validated, where emissions and yield data were used to develop a high-fidelity process model and economic analysis. The following was accomplished in the Phase I: Determined optimal torrefaction process conditions for MSW and biomass through TGA; maximized heating value of fuel while maximizing final mass of torrefied product Demonstrated torrefaction of MSW and biomass feedstocks at 334°C, pulverized to uniform 74 µm particle size, and processed into coal-like feedstocks Demonstrated 8 lb/h pilot-scale EFG using MSW and biomass blends with waste coal; demonstrated 100% biomass in EFG Determined major effects of MSW torrefaction and co-gasifying high-ash coal waste-MSW blends have on pilot-scale EFG Demonstrated blending low-ash, low-sulfur torrefied biomass with high-ash waste bituminous and anthracite refuse coals generates a higher quality syngas compared to syngas from high-ash waste coals Demonstrated a high carbon conversion (> 99.5%) and syngas with 29.47% H2 content, and 0% CH4 content; greater water–gas shift occurs in EFG than predicted by equilibrium ASPEN Plus model Blended lower-ash, high-alkali biomass MSW to lower slag viscosities of the high-ash coal refuse sufficiently for better slag flow compared to feeding the high-ash coal Used low-sulfur biomass to greatly reduce the EFG syngas H2S concentrations and produce non-leachable slag and quench water with very little organic and trace metal contamination Developed a process model and TEA showing the modular PT EFG is cost competitive to existing power plants with the advantage of using low- or negative-value feedstocks such as waste coal stockpiles and non-landfilled MSW; providing a large incentive to implement an economical PT-EFG process

30 DIRECT ENERGY CONVERSION↗

Catalytic Upgrading of Thermochemical Intermediates to Hydrocarbons (Final Report)

A lot of activity in catalytic pyrolysis and hydroprocessing occurred in the past 10-15 years with notable successes and failures; however, very little technical information is available in the open literature from pilot-scale studies such as those performed in this project. Besides, the next step along the technology commercialization pathway is to scale-up the catalytic biomass pyrolysis process, integrate this technology with a hydroprocessing unit, and demonstrate the long-term operation and performance of the integrated process; notably, these were achieved in this project. RTI International has developed a single-step catalytic biomass pyrolysis process to produce a hydrocarbon-rich bio-crude intermediate. This bio-crude is more thermally stable and has lower oxygen content than conventional biomass fast pyrolysis oil, so it can be effectively and efficiently upgraded with traditional hydroprocessing technology to produce gasoline and diesel. Our partner, Haldor Topsøe, has developed a strategy for hydroprocessing bio-crude intermediates based on extensive catalyst and process development in support of converting vegetable oils and waste greases into high-quality diesel fuel. The goal of the originally proposed project was to demonstrate an advanced biofuels technology that integrates a catalytic biomass pyrolysis step and a hydroprocessing step to produce infrastructure-compatible biofuels. The specific technical goals of this project were 1) to optimize the catalytic biomass pyrolysis process to achieve high degree of deoxygenation, while maximizing the bio-crude production, 2) improve bio-crude thermal stability, 3) evaluate the impact of bio-crude quality in the hydroprocessing step, 4) minimize hydrogen demand of the integrated process, and 5) maximize biofuels yields. This project showed that it is technically feasible to use non-zeolitic solid acid catalyst to consistently generate bio-crude with 20% oxygen content and that these liquids can be effectively hydrotreated into low oxygen fuel blendstocks. The reproducibility of the small-scale pyrolysis yields at the 1 tonne/day scale is an achievement worth noting and the effect of pyrolysis temperature on biocrude yields and quality was investigated at the pilot scale. Additionally, advanced analytical techniques were used to analyze bio-crude to investigate the effect of process conditions and feedstock on the concentration and speciation of oxygen-containing compounds. Insights into the impact of oxygen content and oxygen speciation on bio-crdue upgrading were also sought. Clearly, more successful upgrading correlated with bio-crudes with lower oxygen content. This was most evident when partially upgraded bio-crude with 55-90% less oxygen compared to the starting bio-crude was blended with straight run diesel and hydrotreated without any noticeable increase in pressure drop across the reactor or any measurable loss of hydrodenitrification (HDN) activity. Minimizing hydrogen demand while maximizing biofuels yield are the desired outcomes for the integrated process. In summary, several technical challenges remain before catalytic biomass pyrolysis becomes a commercial reality, most notably bio-crude yields and quality still need to be improved. The integrated catalytic biomass pyrolysis hydroprocessing scheme being developed produces intermediates that can be refined for use as drop-in hydrocarbon replacement fuels. From a technology perspective, this advanced biofuel technology produces liquid transportation fuels that can leverage capital expenditures in the existing petroleum refining and distribution infrastructure. From a business perspective, this technology does not face potential market limitations as other nonhydrocarbon biofuels caused by oxygenated blending limitations and fuel certification for light-duty vehicle applications.

09 BIOMASS FUELS↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Demonstration of Scaled-Production of Rare Earth Oxides and Critical Materials from U. S. Coal-Based Sources (Final Report)

The project objective was to demonstrate scaled production of high purity rare earth oxides (REO), nominally exceeding 90% grade, from coal refuse sources using innovative technologies that reduce cost and improve environmental outcomes relative to traditional rare earth processing technologies. The project utilized a critical material pilot plant constructed and tested as part of a previous U.S. Department of Energy project. Target performance criteria was a 50% reduction in production cost based on previous optimum values, 150% increase in recovery and greater than 2% concentrates of rare earth oxides, cobalt and manganese. Concentrate production goals were to produce a rare earth mix oxide product at a rate of 200 grams per day having a minimum purity of 50% as well as products of cobalt and manganese having a minimum purity of 2%. A previous pilot plant investigation identified acid cost as the major contributor to an operating cost that made the recovery of rare earth and other critical metals from bituminous coal sources economically challenging. As such, acid cost reduction was a major target using bio-oxidation reactors to produce sulfuric acid from naturally occurring coal pyrite. Based on laboratory data, a bio-oxidation circuit was designed for the pilot plant to produce 7.5 l/min of acid using two 11-m3 (3000 gallon) reactors equipped with 40 hp aerators for air dispersion. The pilot-scale tests revealed that acid concentration equivalent to as high as 1.0 M sulfuric acid could be continuously produced. However, the bio-acid contained exceptionally high iron concentrations, which complicated downstream processing of the pregnant leach solution (PLS). A TEA of the bio-oxidation circuit showed that production cost was approximately $0.13 per kg acid equivalent if produced using a four-day retention time in the reactors. This value represents a 48% reduction from that of purchased bulk sulfuric acid. Calcination (or roasting) studies were conducted on coarse refuse from West Kentucky No. 13 and Fire Clay coal seam sources. The test results revealed the potential to increase recovery by nearly 100% using temperatures between 500°C to 700°C with light REE recovery value being the most improved. Acid baking of the calcined products using sulfuric acid at 250°C increased heavy rare earth recovery from around 40% to 80% while decreasing the acid requirements by over 50%. The existing pilot plant was upgraded for the pilot scale demonstration of REE and CM recovery. The primary feedstocks were West Kentucky No.13 and heap leach pregnant leach solution (PLS) while a secondary feedstock was a lignite waste material from a construction sand operation. The pilot scale operation started with PLS generation through leaching followed by iron and aluminum removal, nominally at 3.3 and 4.5 pH, respectively. Leaching lixiviants used for the test were industrial grade sulfuric acid or bio-acid generated at the pilot scale facility. For most of the tests, the solid feed rate was 200 lb/hr whereas lixiviant was added at 2 gpm to provide an optimal residence time of 45 minutes. Following the contaminant removal step, several different process schematics were tested with the goal of maximizing REE recovery and purity. In the first test, direct processing of aluminum precipitation raffinate for REE recovery using oxalic acid at pH 1.5 was investigated. Overall REE recovery was approximately 45%. Unfortunately, elevated calcium content in the PLS significantly impacted the RE-Oxide product grade. Similarly, high calcium content decreased both the product purity and grades of CM products. As such, a new flowsheet was tested with the same initial process schematic but different precipitation stages for REEs and CMs at pH 6.0 and 9.0, respectively. It was noted that the overlapping precipitation behavior of Co, Ni and Zn with REEs limited the applicability of this process schematic. While this change increased the RE-Oxide grade from 36% in the first test to 87%, the loss of critical metals to the REE cake and bypass of the REEs to the CM cake significantly impacted the recovery of both REEs and CMs. Therefore, the modified process flowsheet combined oxalic acid precipitation stage raffinate and redissolved CM cake filtrate to maximize both the recovery and purity of the products. Consequently, a RE-Oxide product with 85% purity and CM cakes with over 19% Co, 38% Ni, 14% Zn and 9% Mn content were generated with significantly higher recoveries. While the modified process flowsheet improved recoveries and grades, elemental losses observed in separate precipitation and redissolution losses inspired the adaptation of a single precipitation stage at pH 9.0 for both REEs and CMs. This change was anticipated to maximize the REE recovery while minimizing the costs associated with separated redissolution and processing stages. As expected, REE recovery in this new circuit arrangement was over 56% with a product grade of over 87% RE-Oxide content. Similarly, Co, Ni, Mn, and Zn recoveries of 54%, 40%, 67%, and 66%, respectively, were achieved. Unfortunately, the elevated calcium content present in the solution due to its precipitation at pH 9.0 caused a decrease in the CM cake quality. Therefore, the final process flowsheet involved the addition of calcium oxalate precipitation following the oxalic acid precipitation stage, which effectively eliminated calcium contamination of the CM products. Finally, the pilot scale experiments conducted using bio-acid achieved comparable REE leaching recoveries to the conventional sulfuric acid leaching. Elevated iron concentration in the solution caused the co-precipitation of REEs with the iron and aluminum cake, resulting in the REE losses. Furthermore, elevated iron content bypassing the iron and aluminum precipitation stages contaminated the metal sulfide and manganese cake, respectively. A techno-economic analysis was performed based on a commercial facility capable of treating 500 tph of coal-based material. The production cost for West Kentucky No. 13 coarse refuse material ranged from approximately $500-$700/kg of total rare earth oxide whereas the lignite source had significantly lower production cost of $100-$300/kg. The significant difference in cost was due to the easier leaching characteristics of the lignite material and the higher feed concentrations. All process scenarios resulted in a negative net present value (NPV). For the lignite feedstock, laboratory REE leach recovery values were about 30% higher than the pilot plant data. Using the lab leach results, a positive net present value was achieved and the production cost decreased from $100-$300 $/kg to less than $150/kg of total REO.

01 COAL, LIGNITE, AND PEAT↗

Application of Partial Least Squares Approaches to Pyroprocessing ER Data

Multivariate approaches show promise for application to process monitoring for safeguards of pyroprocessing. Past MPACT work explored the application of Principal Component Analysis (PCA) to detect off-normal conditions in pyroprocessing electrorefiner (ER) data from in the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL) known as the Scalable Pyrochemical Recycling testbed (SPyRe) ER. PCA, however, does not consider the output variables. In FY24, multivariate analysis was extended from PCA to Partial Least Squares (PLS) analysis. PLS maximizes the variance between both the input signals and output variables. In the case of this work, PLS was applied in two different manners: Predictive PLS and Discriminant PLS. Predictive PLS maximizes the covariance between the process variables of the ER and the measured U concentration from in-situ voltammetry. Discriminant PLS maximizes the covariance between the process variables and a set of training process “states” such as known off-normal conditions. By projecting into the latent variable space in PLS, the process variables can be regressed onto the outputs and predictions can be made for new data sets. In this work, by applying predictive PLS, a penalized non-linear PLS approach was able to make predictions of concentration based on test and training data and detect when operations were off-normal. However, the predictive PLS does not classify the signals to which off-normal operations are attributable. Discriminant PLS can be used to classify off-normal operations but is inadequate to properly classify specific off-normal classes like power supply faults when the Discriminant PLS model is only specifically trained to detect that off-normal class. When all faults are trained against the observation data, all three operational classes are accurately classified and distinguished. Thus, future application of latent variable techniques should not select any given method, but should use a mixture of PCA, Predictive PLS, and Discriminant PLS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LAND AND WATER USE CHARACTERISTICS AND HUMAN HEALTH INPUT PARAMETERS FOR USE IN ENVIRONMENTAL DOSIMETRY AND RISK ASSESSMENTS AT THE SAVANNAH RIVER SITE

Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations at SRS are documented. Based on comparisons to the 2009 SRS environmental compliance doses, the following effects are expected in future SRS compliance dose calculations: (1) Aquatic all-pathway maximally exposed individual doses may go up about 10 percent due to changes in the aquatic bioaccumulation factors; (2) Aquatic all-pathway collective doses may go up about 5 percent due to changes in the aquatic bioaccumulation factors that offset the reduction in average individual water consumption rates; (3) Irrigation pathway doses to the maximally exposed individual may go up about 40 percent due to increases in the element-specific transfer factors; (4) Irrigation pathway collective doses may go down about 50 percent due to changes in food productivity and production within the 50-mile radius of SRS; (5) Air pathway doses to the maximally exposed individual may go down about 10 percent due to the changes in food productivity in the SRS area and to the changes in element-specific transfer factors; and (6) Air pathway collective doses may go down about 30 percent mainly due to the decrease in the inhalation rate assumed for the average individual.

61 RADIATION PROTECTION AND DOSIMETRY↗

Systems and Photosystems: Cellular Limits of Autotrophic Productivity in Cyanobacteria

Recent advances in the modeling of microbial growth and metabolism have shown that growth rate critically depends upon the optimal allocation of finite proteomic resources among different cellular functions and that modeling growth rates becomes more realistic with the explicit accounting for the costs of macromolecular synthesis, most importantly, protein expression. The “proteomic constraint” is considered together with its application to understanding photosynthetic microbial growth. The central hypothesis is that physical limits of cellular space (and corresponding solvation capacity) in conjunction with cell surface-to-volume ratios represent the underlying constraints on the maximal rate of autotrophic microbial growth. The limitation of cellular space thus constrains the size the total complement of macromolecules, dissolved ions, and metabolites. To a first approximation, the upper limit in the cellular amount of the total proteome is bounded this space limit. This predicts that adaptation to osmotic stress will result in lower maximal growth rates due to decreased cellular concentrations of core metabolic proteins necessary for cell growth owing the accumulation of compatible osmolytes, as surmised previously. The finite capacity of membrane and cytoplasmic space also leads to the hypothesis that the species-specific differences in maximal growth rates likely reflect differences in the allocation of space to niche-specific proteins with the corresponding diminution of space devoted to other functions including proteins of core autotrophic metabolism, which drive cell reproduction. An optimization model for autotrophic microbial growth, the autotrophic replicator model, was developed based upon previous work investigating heterotrophic growth. The present model describes autotrophic growth in terms of the allocation protein resources among core functional groups including the photosynthetic electron transport chain, light-harvesting antennae, and the ribosome groups.

59 BASIC BIOLOGICAL SCIENCES↗

Basic Economic Principles

An economic approach to design efficient transportation systems involves maximizing an objective function that reflects both goals and costs. A demand curve can be derived by finding the quantities of a good that solve the maximization problem as one varies the price of that commodity, holding income and the prices of all other goods constant. A supply curve is derived by applying the idea of profit maximization of firms. The production function determines the relationship between input and output.

Tideman, T. N.↗

A counter example in linear feature selection theory

The linear feature selection problem in multi-class pattern recognition is described as that of linearly transforming statistical information from n-dimensional (real Euclidean) space into k-dimensional space, while requiring that average interclass divergence in the transformed space decrease as little as possible. Divergence is the expected interclass divergence derived from Hajek two-class divergence; it is known that there always exists a k x n matrix B such that the transformation determined by B maximizes the divergence in k-dimensional space. It is known that, if Q is any k x k invertible matrix, and B is as defined above, then QB again maximizes the divergence in k-space. It is shown that the converse of this result is false: two matrices exist, B sub 1 and B sub 2, each of which maximizes transformed divergence, which are not related in the fashion B sub 2 = QB sub 1 for any k x k matrix Q.

Brown, D. R.↗

Frequency and duration of interval training programs and changes in aerobic power

The present study was designed to ascertain whether a training frequency of 2 days/wk for a 7- and 13-wk interval training program would produce improvement in maximal aerobic power comparable to that obtained from 7- and 13-wk programs of the same intensity consisting of 4 training days/wk. After training, there was a significant increase in maximal aerobic power that was independent of both training frequency and duration. Maximal heart rate was significantly decreased following training. Submaximal aerobic power did not change with training, but submaximal heart rate decreased significantly with greater decreases the more frequent and the longer the training.

Fox, E. L.↗

On signal design by the R sub 0 criterion for non-white Gaussian noise channels

The use of the R sub 0 criterion for modulation system design is investigated for channels with non-white Gaussian noise. A signal space representation of the waveform channel is developed, and the cut-off rate R sub 0 for vector channels with additive nonwhite Gaussian noise and unquantized demodulation is derived. When the signal unput to the channel is a continuous random vector, maximization of R sub 0 with constrained average signal energy leads to a water-filling interpretation of optimal energy distribution in signal space. The necessary condition for a finite signal set to maximize R sub 0 with constrained energy and an equally likely probability assignment of signal vectors is presented, and an algorithm is outlined for numerically computing the optimum signal set. A necessary condition on a constrained energy, finite signal set is found which maximizes a Taylor series approximation of R sub 0. This signal set is compared with the finite signal set which has the water-filling average energy distribution.

Bordelon, D. L.↗

Tailcone on orbiter altitude attainable at the maximum ALT interface airspeed

A preflight analysis performed for verification of the ALT mated vehicle incidence angle which maximizes the post separation altitude attainment by the orbiter at the maximum approach and landing test (ALT) interface airspeed (300 KEAS) is discussed. In the analysis, altitude versus airspeed profiles are generated for each of the three incidence angles that include and bound the recommended incidence angle for both the forward and the aft cg tailcone on orbiter configurations. Results show that the recommended incidence angles maximize the orbiter post separation altitude attainable within an acceptable tradeoff between separation clearance capability and orbiter structural constraints. Within constraints, the incidence angle that maximizes the orbiter altitude at the maximum ALT interface airspeed for both the forward and aft cg orbiter tailcone on configurations is 6.0 deg. The requirement for a parametric analysis of orbiter altitude attainable at the maximum ALT interface airspeed is stated along with the specifications, assumptions, and analytical approach used to determine orbiter altitude attainable at the maximum ALT interface airspeed.

Glenn, G. M.↗

Plasma /Na+/, /Ca++/, and volume shifts and thermoregulation during exercise in man

Graded-exercise experiments are conducted on six trained male runners (19-23 yr) subjected to ergometer exercise in a program consisting of 30-min resting control period, 60 min of rest or exercise at work loads that resulted in a maximal oxygen uptake equivalent to 6% (resting), 23%, 43%, and 62% of maximal oxygen uptake, followed by 30 min of recovery. The parameters measured and discussed are rectal temperature (T-re), skin temperatures at different spots, maximal oxygen uptake, plasma volume (PV), and various plasma electrolyte and protein concentrations. The objectives are to determine whether the increased T-re during progressively greater work loads are related to plasma sodium ion and calcium ion concentrations, as well as to evaluate the influence of PV shifts on the electrolyte and osmotic concentrations. The results suggest that the shift (loss) in PV accounts for the increases in the plasma constituent concentrations that result in significant correlations with T-re.

Greenleaf, J. E.↗

Induced venous pooling and cardiorespiratory responses to exercise after bed rest

Venous pooling induced by a specially constructed garment is investigated as a possible means for reversing the reduction in maximal oxygen uptake regularly observed following bed rest. Experiments involved a 15-day period of bed rest during which four healthy male subjects, while remaining recumbent in bed, received daily 210-min venous pooling treatments from a reverse gradient garment supplying counterpressure to the torso. Results of exercise testing indicate that while maximal oxygen uptake endurance time and plasma volume were reduced and maximal heart rate increased after bed rest in the control group, those parameters remained essentially unchanged for the group undergoing venous pooling treatment. Results demonstrate the importance of fluid shifts and venous pooling within the cardiovascular system in addition to physical activity to the maintenance of cardiovascular conditioning.

Convertino, V. A.↗

A fuel-efficient cruise performance model for general aviation piston engine airplanes

A fuel-efficient cruise performance model which facilitates maximizing the specific range of General Aviation airplanes powered by spark-ignition piston engines and propellers is presented. Airplanes of fixed design only are considered. The uses and limitations of typical Pilot Operating Handbook cruise performance data, for constructing cruise performance models suitable for maximizing specific range, are first examined. These data are found to be inadequate for constructing such models. A new model of General Aviation piston-prop airplane cruise performance is then developed. This model consists of two subsystem models: the airframe-propeller-atmosphere subsystem model; and the engine-atmosphere subsystem model. The new model facilitates maximizing specific range; and by virtue of its implicity and low volume data storge requirements, appears suitable for airborne microprocessor implementation.

Parkinson, R. C. H.↗

A Study of Accretion in Compact Sources: Disk Precession and Jet Helicity

The effect of adiabatic expansion on the propagation and growth of helical twisting on a supersonic jet is investigated. Cooling of the jet material increases the jet's Mach number and increases the jet's density relative to that of the external medium. This has the effect of decreasing the maximum rate of growth and increasing the maximally unstable wavelength relative to the jet's radius. Propagation effects cause the wavelength of helical waves to change at a rate different from that of the maximally unstable wavelength with the result that the characteristic wavelength of helical twisting is not equal to this wavelength. The most rapidly growing helical wave will have a wavelength as much as a factor of 2 different from the instantaneous maximally unstable wavelength.

Hardee, P. E.↗

Approaches to optimization of SS/TDMA time slot assignment

Reduction techniques for traffic matrices are explored in some detail. These matrices arise in satellite switched time-division multiple access (SS/TDMA) techniques whereby switching of uplink and downlink beams is required to facilitate interconnectivity of beam zones. A traffic matrix is given to represent that traffic to be transmitted from n uplink beams to n downlink beams within a TDMA frame typically of 1 ms duration. The frame is divided into segments of time and during each segment a portion of the traffic is represented by a switching mode. This time slot assignment is characterized by a mode matrix in which there is not more than a single non-zero entry on each line (row or column) of the matrix. Investigation is confined to decomposition of an n x n traffic matrix by mode matrices with a requirement that the decomposition be 100 percent efficient or, equivalently, that the line(s) in the original traffic matrix whose sum is maximal (called critical line(s)) remain maximal as mode matrices are subtracted throughout the decomposition process. A method of decomposition of an n x n traffic matrix by mode matrices results in a number of steps that is bounded by n(2) - 2n + 2. It is shown that this upper bound exists for an n x n matrix wherein all the lines are maximal (called a quasi doubly stochastic (QDS) matrix) or for an n x n matrix that is completely arbitrary. That is, the fact that no method can exist with a lower upper bound is shown for both QDS and arbitrary matrices, in an elementary and straightforward manner.

Wade, T. O.↗

The optimal polarizations for achieving maximum contrast in radar images

There is considerable interest in determining the optimal polarizations that maximize contrast between two scattering classes in polarimetric radar images. A systematic approach is presented for obtaining the optimal polarimetric matched filter, i.e., that filter which produces maximum contrast between two scattering classes. The maximization procedure involves solving an eigenvalue problem where the eigenvector corresponding to the maximum contrast ratio is an optimal polarimetric matched filter. To exhibit the physical significance of this filter, it is transformed into its associated transmitting and receiving polarization states, written in terms of horizontal and vertical vector components. For the special case where the transmitting polarization is fixed, the receiving polarization which maximizes the contrast ratio is also obtained. Polarimetric filtering is then applies to synthetic aperture radar images obtained from the Jet Propulsion Laboratory. It is shown, both numerically and through the use of radar imagery, that maximum image contrast can be realized when data is processed with the optimal polarimeter matched filter.

Swartz, A. A.↗