Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intervals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Submillimeter and millimeter observations of Uranus and Neptune

Neptune and Uranus were studied at submillimeter and millimeter wavelengths for 2 yr using the UK IR telescope and the NASA IR telescope at Mauna Kea and the 12 dish at Kitt Peak, AZ. The brightness temperatures of both planets are provided at various wavelengths over the 0.35-3.3 mm interval scanned in the study. The present data, in combination with data from the 17 microns-3 mm interval scanned in the study. The present data, in combination with data from the 17 microns-3 mm interval taken during previous campaigns, are employed to model the temperature structures in the atmospheres of the two planets over the vertical range 100 mbar-8 bar. The data support the presence of active convection processes at the 1 bar level and deeper in both atmospheres. A static equilibrium however, exists between para-H2 and ortho-H2, along with a constant CH4 fraction of 2 percent. Deficiencies in the current database are detailed.

Orton, G. S.↗

Effect of posture on arterial baroreflex control of heart rate in humans

The effects of blood-volume redistribution induced by postural changes on baroreflex activity are investigated. The central blood volume and baroreceptor functions of ten males between 23-51 years old were examined while they were in the head-up tilt (HUT), head-down tilt (HDT), and supine positions. It is observed that during HDT at 15 deg the pulse interval over the first five cardiac cycles following neck suction onset is 51 + or - 18 ms longer, at 30 deg it is 61 + or - 20 ms longer, and at 45 deg it is 74 + or - 35 ms longer than at supine; during HUT at 15 deg the pulse interval is 25 + or - 9 ms shorter than when supine, but for the 30 and 45 deg there is no significant difference in pulse interval detected. The data reveal that posture does modify arterial baroreflex control of heart rate.

Harrison, M. H.↗

Approximate Cartesian state transition matrix

Based on a Taylor series expansion, an easily-computed approximation to the Cartesian state transition matrix is presented for a general velocity-independent force field. Suitable for the short time intervals encountered in onboard navigation applications of the extended Kalman filter, it provides approximately five decimal digits of accuracy for earth orbiting spacecraft with update intervals of one minute, and better accuracy for shorter intervals.

Markley, F. L.↗

Dynamic modelling and estimation of the error due to asynchronism in a redundant asynchronous multiprocessor system

The use of Redundant Asynchronous Multiprocessor System to achieve ultrareliable Fault Tolerant Control Systems shows great promise. The development has been hampered by the inability to determine whether differences in the outputs of redundant CPU's are due to failures or to accrued error built up by slight differences in CPU clock intervals. This study derives an analytical dynamic model of the difference between redundant CPU's due to differences in their clock intervals and uses this model with on-line parameter identification to idenitify the differences in the clock intervals. The ability of this methodology to accurately track errors due to asynchronisity generate an error signal with the effect of asynchronisity removed and this signal may be used to detect and isolate actual system failures.

Huynh, Loc C.↗

Method for Veterbi decoding of large constraint length convolutional codes

A new method of Viterbi decoding of convolutional codes lends itself to a pipline VLSI architecture using a single sequential processor to compute the path metrics in the Viterbi trellis. An array method is used to store the path information for NK intervals where N is a number, and K is constraint length. The selected path at the end of each NK interval is then selected from the last entry in the array. A trace-back method is used for returning to the beginning of the selected path back, i.e., to the first time unit of the interval NK to read out the stored branch metrics of the selected path which correspond to the message bits. The decoding decision made in this way is no longer maximum likelihood, but can be almost as good, provided that constraint length K in not too small. The advantage is that for a long message, it is not necessary to provide a large memory to store the trellis derived information until the end of the message to select the path that is to be decoded; the selection is made at the end of every NK time unit, thus decoding a long message in successive blocks.

Hsu, In-Shek↗

Chip Advancer For GPS Receiver

Instrument errors made negligible. For each integration interval, both delay and rate of change of delay initialized to small fraction of chip - for example, to order of 10 to the negative 7th power - thereby making feedback control and extraction of delay highly accurate and flexible. With appropriate selection of sampling rate relative to chip rate, commensurability errors reduced to extremely small levels. In Global Positioning System (GPS) receiver, pseudorandom code sequence generated by simple digital logic incorporating effects of time, delay, and rate of change of delay. Flexibility in starting time and sum interval very useful in aligning correlation interval with beginnings and endings of data bits.

Meehan, Thomas K.↗

An extended Cretaceous-Tertiary (K/T) stable isotope record. Implications for paleoclimate and the nature of the K/T boundary event

In order to obtain a detailed single site record of marine productivity and temperature across the Cretaceous-Tertiary (K/T) boundary, both delta C-13 and delta O-18 values were measured in paired surface and deep water microfossil and nannofossil samples of mid-latitude South Atlantic Deep Sea Drilling Project (DSDP) Site 528. Additionally, the percent sedimentary carbonate content of the rock samples from which the analyzed fossil samples were taken, were determined. The analyzed interval spanned the last approximately 1 million years of the Cretaceous (the Abathomphalus mayaroensis foraminiferal zone) and the first approximately 9 million years of the Tertiary (the Paleocene). Paired samples were analyzed every 150 cm of the entire 165 m sampled interval (1 sample per recovered DSDP section), every 20 cm for 2.0 m below and 2.5 m above the K/T boundary, and every 0.25 cm immediately below, at, and above the K/T boundary clay. The Cretaceous-Tertiary boundary and earliest Paleocene record of DSDP Site 528 is marked by at least two strong decreases in the surface-to-deep delta C-13 gradient (one at the K/T boundary (66.4 mybp1) and one approximately 150,000 to 200,000 years later). Both of these decreases co-occur with radical decreases in percent carbonate content and appear to indicate not one, but two, strong decreases in marine primary productivity during the analyzed interval.

Dhondt, Steven↗

Stratospheric ozone and temperature responses to short-term solar ultraviolet variations - Reproducibility of low-latitude response measurements

Two independent 22-month time intervals of NIMBUS 7 solar backscattered UV (SBUV) ozone and stratospheric and mesospheric sounder (SAMS) temperature measurements for the upper stratosphere at low latitudes are analyzed to calculate mean responses to observed changes in solar ultraviolet spectral irradiance occurring on the time scale of the solar rotation period. Average cross-correlation functions of both SBUV ozone and SAMS temperature versus the solar 205 nm flux are in substantial agreement for these two intervals. Linear regression methods are applied to estimate response amplitudes or sensitivities. The derived sensitivities and phase lags relative to the 205 nm flux are also in approximate agreement for the two separate intervals although the temperature response measurements exhibit larger deviations. These results support the validity of previously reported measurements on the 27-day time scale, and impose firmer constraints on proposed theoretical models for the response of the stratosphere to solar UV forcing on both short and long time scales.

Hood, L. L.↗

Large-scale fluctuations in the solar wind at 1 AU - 1978-1982

The large-scale fluctuations in the strength of the magnetic field B and the bulk speed V at 1 AU were investigated on the basis of hourly averages of IMP 8 and ISEE 3 data compiled by Couzens and King (1986). The power spectra of the intermediate frequency fluctuations in B at 1 AU had the form of a power law with exponent 1.92 + or - 0.06 during the 1978-1982 interval. The contributions of jumps to the spectra of the large-scale fluctuations in B and V were studied for the interval from days 226 to 365, 1978, which is representative of other such intervals. Of the jumps in B, 22 percent have the signature of a forward or reverse shock.

Burlaga, L. F.↗

Active Control of the Forced and Transient Response of a Finite Beam

When studying structural vibrations resulting from a concentrated source, many structures may be modelled as a finite beam excited by a point source. The theoretical limit on cancelling the resulting beam vibrations by utilizing another point source as an active controller is explored. Three different types of excitation are considered, harmonic, random, and transient. In each case, a cost function is defined and minimized for numerous parameter variations. For the case of harmonic excitation, the cost function is obtained by integrating the mean squared displacement over a region of the beam in which control is desired. A controller is then found to minimize this cost function in the control interval. The control interval and controller location are continuously varied for several frequencies of excitation. The results show that control over the entire beam length is possible only when the excitation frequency is near a resonant frequency of the beam, but control over a subregion may be obtained even between resonant frequencies at the cost of increasing the vibration outside of the control region. For random excitation, the cost function is realized by integrating the expected value of the displacement squared over the interval of the beam in which control is desired. This is shown to yield the identical cost function as obtained by integrating the cost function for harmonic excitation over all excitation frequencies. As a result, it is always possible to reduce the cost function for random excitation whether controlling the entire beam or just a subregion, without ever increasing the vibration outside the region in which control is desired. The last type of excitation considered is a single, transient pulse. A cost function representative of the beam vibration is obtained by integrating the transient displacement squared over a region of the beam and over all time. The form of the controller is chosen a priori as either one or two delayed pulses. Delays constrain the controller to be causal. The best possible control is then examined while varying the region of control and the controller location. It is found that control is always possible using either one or two control pulses. The two pulse controller gives better performance than a single pulse controller, but finding the optimal delay time for the additional controllers increases as the square of the number of control pulses.

Post, John Theodore↗

Factor analytic reduction of the carotid-cardiac baroreflex parameters

An accepted method for measuring the responsiveness of the carotid-cardiac baroreflex to arterial pressure changes is to artificially stimulate the baroreceptors in the neck. This is accomplished by using a pressurized neck cuff which constricts and distends the carotid artery and subsequently stimulates the baroreceptors. Nine physiological responses to this type of stimulation are quantified and used as indicators of the baroreflex. Thirty male humans between the ages 27 and 46 underwent the carotid-cardiac baroreflex test. The data for the nine response parameters were analyzed by principle component factor analysis. The results of this analysis indicated that 93 percent of the total variance across all nine parameters could be explained in four dimensions. Examination of the factor loadings following an orthogonal rotation of the principle components indicated four well defined dimensions. The first two dimensions reflected location points for R-R interval and carotid distending pressure respectively. The third dimension was composed of measures reflecting the gain of the reflex. The fourth dimension was the ratio of the resting R-R interval to R-R interval during simulated hypertension. The data suggests that the analysis of all nine baroreflex parameters is redundant.

Ludwig, David A.↗

Multiple symbol differential detection of uncoded and trellis coded MPSK

A differential detection for MPSK, which uses a multiple symbol observation interval, is presented and its performance analyzed and simulated. The technique makes use of maximum-likelihood sequence estimation of the transmitted phases rather than symbol-by-symbol detection as in conventional differential detection. As such the performance of this multiple symbol detection scheme fills the gap between conventional (two-symbol observation) differentially coherent detection of MPSK and ideal coherent of MPSK with differential encoding. The amount of improvement gained over conventional differential detection depends on the number of phases, M, and the number of additional symbol intervals added to the observation. What is particularly interesting is that substantial performance improvement can be obtained for only one or two additional symbol intervals of observation. The analysis and simulation results presented are for uncoded and trellis coded MPSK.

Divsalar, Dariush↗

Balloon borne in-situ detection of OH in the stratosphere from 37 to 23 km

The OH number density in the stratosphere has been measured over the altitude interval of 37 to 23 km at midday via a balloon-borne gondola launched from Palestine, Texas on July 6, 1988. OH radicals are detected with a laser-induced fluorescence instrument employing a 17-kHz-repetition-rate copper vapor laser-pumped dye laser optically coupled to an enclosed flow, in-situ sampling chamber. OH abundances ranged from 88 + or - 3l pptv in the 36 to 35 km interval to 0.9 + or - 0.8 pptv in the 24 to 23 km interval. The stated uncertainty includes that from both measurement precision and accuracy. Simultaneous detection of ozone and water vapor densities was carried out with separate on-board instruments.

Stimpfle, R. M.↗

Multiple-symbol differential detection of MPSK

A differential detection technique for MPSK (multiple-phase shift keying), which uses a multiple-symbol observation interval, is presented, and its performance is analyzed and simulated. The technique makes use of maximum-likelihood sequence estimation of the transmitted phases rather than symbol-by-symbol detection as in conventional differential detection. Thus, the performance of this multiple-symbol detection scheme fills the gap between conventional (two-symbol observation) differentially coherent detection of MPSK and ideal coherent of MPSK with differential encoding. The amount of improvement gained over conventional differential detection depends on the number of phases M and the number of additional symbol intervals added to the observation. What is particularly interesting is that substantial performance improvement can be obtained for only one or two additional symbol intervals of observation. The analysis and simulation results presented are for uncoded MPSK.

Divsalar, Dariush↗

Analysis of pressure-broadened ozone spectra in the 3 micron region

The Molecular Spectroscopy Lab at NASA-Langley has been involved in a long term effort to carefully characterize the infrared spectra of small molecules of atmospheric interest, including methane, water vapor, ozone, and their isotopic counterparts. High resolution gas phase infrared spectra are obtained using both a tunable diode laser system, and the McMath Fourier transform spectrometer at the Kitt Peak Solar Observatory. Spectra are obtained at various pressures and temperatures for pure gas samples, and for samples containing mixtures of the species of interest in nitrogen, oxygen, or air. From these spectra, using a nonlinear least squares fitting technique, spectral parameters of position, intensity, and half-width were determined for varying laboratory conditions that approximate atmospheric conditions experienced in remote sensing situations. These parameters are of interest in theoretical studies of these species, as well as in allowing more accurate interpretation of remote sensing data. The current work involves the analysis of a series of McMath FTIR spectra of ozone broadened by mixing with air, nitrogen, or oxygen. Each spectrum covers the region from 2396 to 4057/cm. Each vibrational band is analyzed by first diving its region into small intervals containing a few well isolated absorption lines of reasonable intensity. Each of these small intervals is fit by multiple iterations of the nonlinear least square program until residuals are minimized to a reasonable value which corresponds to the noise level of the measured spectrum. Intervals for the 3 nu(sub 3) ozone band in the region from 3000 to 3060 wavenumbers are being examined.

Prochaska, Eleanor S.↗

Doppler-corrected differential detection system

Doppler in a communication system operating with a multiple differential phase-shift-keyed format (MDPSK) creates an adverse phase shift in an incoming signal. An open loop frequency estimation is derived from a Doppler-contaminated incoming signal. Based upon the recognition that, whereas the change in phase of the received signal over a full symbol contains both the differentially encoded data and the Doppler induced phase shift, the same change in phase over half a symbol (within a given symbol interval) contains only the Doppler induced phase shift, and the Doppler effect can be estimated and removed from the incoming signal. Doppler correction occurs prior to the receiver's final output of decoded data. A multiphase system can operate with two samplings per symbol interval at no penalty in signal-to-noise ratio provided that an ideal low pass pre-detection filter is employed, and two samples, at 1/4 and 3/4 of the symbol interval T sub s, are taken and summed together prior to incoming signal data detection.

Simon, Marvin K.↗

Enhanced global positioning system delta-range processing

A circuit is shown which utilizes signals transmitted from global positioning system satellites to create change in phase signals. The change in phase signals are measured over a predetermined time interval, one· second, and stored. The stored signals are applied to a Kalman filter and back to the storage unit so that each one second time interval includes the information from all previous time intervals. This accumulated information is referred to as accumulated Delta-Range information which permits a more rapid determination of position by the circuit.

Alison Brown↗

A statistical note on the redundancy of nine standard baroreflex parameters

An accepted method for measuring the responsiveness of the carotid-cardiac baroreflex to arterial pressure changes is to artificially stimulate the baroreceptors in the neck with a pressurized neck chamber. Nine physiological responses to this type of stimulation are quantified and used as indicators of the baroreflex response function. Thirty male humans between the ages of 27 and 46 underwent the carotid-cardiac baroreflex test. The data for the nine response parameters were analyzed by principle component factor analysis. The results indicated that 92.5 percent of the total variance across all nine parameters could be explained in four dimensions. The first two dimensions reflected location points for R-R interval and carotid distending pressure, respectively. The third factor was composed of measures reflecting the gain (responsiveness) of the reflex. The fourth dimension was the ratio of baseline R-R interval to the maximal R-R interval response during simulated hypertension. The data suggest that the analysis of all nine baroreflex parameters is likely to be redundant and researchers should account for these redundancies either in their analyses or conclusions.

Ludwig, David A.↗