At least 1,045 records · Page 58

Results from SIM's Thermo-Opto-Mechanical (TOM3) Testbed

Future space-based optical interferometers, such as the Space Interferometer Mission Planet Quest (SIM), require thermal stability of the optical wavefront to the level of picometers in order to produce astrometric data at the micro-arc-second level. In SIM, the internal path of the interferometer will be measured with a small metrology beam whereas the starlight fringe position is estimated from a large concentric annular beam. To achieve the micro-arc-second observation goal for SIM, it is necessary to maintain the optical path difference between the central and the outer annulus portions of the wavefront of the front-end telescope optics to a few tens of picometers. The Thermo-Opto-Mecha nical testbed (TOM3) was developed at the Jet Propulsion Laboratory to measure thermally induced optical deformations of a full-size flight-like beam compressor and siderostat, the two largest optics on SIM, in flight-like thermal environments. A Common Path Heterodyne Interferometer (COPHI) developed at JPL was used for the fine optical path difference measurement as the metrology sensor. The system was integrated inside a large vacuum chamber in order to mitigate the atmospheric and thermal disturbances. The siderostat was installed in a temperature-controlled thermal shroud inside the vacuum chamber, creating a flight-like thermal environment. Detailed thermal and structural models of the test articles (siderostat and compressor) were also developed for model prediction and correlation of the thermal deformations. Experimental data shows SIM required thermal stability of the test articles and good agreement with the model predictions.

interferometry↗

Performance of the Primary Mirror Center-of-curvature Optical Metrology System During Cryogenic Testing of the JWST Pathfinder Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 m in diameter and consists of 18 hexagonal segments, each 1.5 m point-to-point. Each segment has a six degree-of-freedom hexapod actuation system and a radius-of-curvature (RoC) actuation system. The full telescope will be tested at its cryogenic operating temperature at Johnson Space Center. This testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The COCOA includes an interferometer, a reflective null, an interferometer-null calibration system, coarse & fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer (MWIF) is used for alignment & phasing of the PM segments. The ADMA is used to measure, and set, the spacing between the PM and the focus of the COCOA null (i.e. the PM center-of-curvature) for determination of the ROC. The performance of these metrology systems was assessed during two cryogenic tests at JSC. This testing was performed using the JWST Pathfinder telescope, consisting mostly of engineering development & spare hardware. The Pathfinder PM consists of two spare segments. These tests provided the opportunity to assess how well the center-of-curvature optical metrology hardware, along with the software & procedures, performed using real JWST telescope hardware. This paper will describe the test setup, the testing performed, and the resulting metrology system performance. The knowledge gained and the lessons learned during this testing will be of great benefit to the accurate & efficient cryogenic testing of the JWST flight telescope.

optical testing↗

Performance of the Center-Of-Curvature Optical Assembly During Cryogenic Testing of the James Webb Space Telescope

The James Webb Space Telescope (JWST) primary mirror (PM) is 6.6 meters in diameter and consists of 18 hexagonal segments, each 1.5 meters point-to-point. Each segment has a 6 degree-of-freedom hexapod actuation system and a radius-of-curvature (ROC) actuation system. The full telescope was tested at its cryogenic operating temperature at Johnson Space Center (JSC) in 2017. This testing included center-of-curvature measurements of the PM wavefront error using the Center-of-Curvature Optical Assembly (COCOA), along with the Absolute Distance Meter Assembly (ADMA). The COCOA included an interferometer, a reflective null, an interferometer-null calibration system, coarse and fine alignment systems, and two displacement measuring interferometer systems. A multiple-wavelength interferometer was used to enable alignment and phasing of the PM segments. By combining measurements at two laser wavelengths, synthetic wavelengths up to 15 millimeters could be achieved, allowing mirror segments with millimeter-level piston errors to be phased to the nanometer level. The ADMA was used to measure and set the spacing between the PM and the focus of the COCOA null (i.e., the PM center-of-curvature) for determination of the ROC. This paper describes the COCOA, the PM test setup, the testing performed, the test results, and the performance of the COCOA in aligning & phasing the PM segments and measuring the final PM wavefront error.

JWST↗

Grid polarizers for infrared Fourier spectrometers

Infrared grid polarizers consisting of copper lines with a 3.6-micron grid constant on a 4-micron-thick Mylar polyester substrate have been prepared by the techniques of photolithography and sputter-etching. Their polarization properties have been measured and found to be suitable for use at infrared frequencies below 700/cm. The polarizers have been used to extend the useful frequency range of a Martin-Puplett polarizing interferometer designed for Fourier transform spectroscopy. The efficiency of the interferometer has been measured over a frequency range from 50 to 700/cm and compared to that of a conventional Michelson interferometer. The results are shown to be consistent with the measured properties of the polarizers. Methods are suggested for improving the efficiency of a Martin-Puplett interferometer which employs these polarizers.

Challener, W. A.↗

High sensitivity laser interferometry for detection of boundary-layer transition

A high sensitivity laser interferometry for continuous monitoring of optical path changes is presented. The sensitivity to small changes in the optical path is achieved by means of a feedback system which keeps the interferometer at its maximum (and linear) position. Two experiments were designed to verify the interferometer's performance, both in direct and in scattering configurations. In each case, small temperature fluctuations were introduced as the signal source. Simultaneous measurement of temperature were compared with the results of the interferometer. Good correlation between the results were obtained. Finally, the application of the high sensitivity interferometer for detection of boundary-layer transition is examined. Optical signal strength and possible sources of noise are examined. Some methods of model surface preparation for enhancement of signal-to-noise ratio are discussed.

Modarress, D.↗

Optical astronomical interferometry - Requirements on stellar Michelson interferometry and heterodyne interferometry for high-resolution imaging

The requirements for optical path compensation on space-based (no atmospheric-induced disturbance) heterodyne interferometers and generalized Michelson stellar interferometers are developed. It is demonstrated that heterodyne interferometers require optical path compensation to well within the coherence length dictated by its bandwidth, while Michelson stellar interferometers require compensation to a fraction of their utilized wavelength.

Silverglate, P. R.↗

High sensitivity boundary layer transition detector

A high sensitivity differential interferometer has been developed to locate the region where the boundary layer flow changes from laminar to turbulent. Two experimental configurations have been used to evaluate the performance of the interferometer, open shear layer configuration and wind tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations in the order of .001 the laser wavelength.

Azzazy, M.↗

Liquid helium cooled Fabry-Perot spectrometers

An account is given of two successful efforts to construct cryogenic Fabry-Perot interferometers that are sufficiently compact and stable for such harsh conditions as those of balloon or space observations, as well as ground-based ones. Attention is given to the design features and performance of a Fabry-Perot interferometer incorporating an electromagnet actuator, the ISAS interferometer, a Fabry-Perot spectrometer with superconducting actuators, and the University of Arizona interferometer.

Okuda, H.↗

High-sensitivity density fluctuation detector

A high-sensitivity differential interferometer has been developed to detect small density fluctuations over an optical path length of the order of the boundary layer thickness near transition. Two experimental configurations have been used to evaluate the performance of the interferometer: an open shear-layer configuration and a wind-tunnel turbulent spot configuration. In each experiment small temperature fluctuations were introduced as the signal source. Simultaneous cold-wire measurements have been compared with the interferometer data. The comparison shows that the interferometer is sensitive to very weak phase variations of the order of 0.001 of the laser wavelength.

Azzazy, M.↗

The Next Century Astrophysics Program

The Astrophysics Division within the NASA Office of Space Science and Applications (OSSA) has defined a set of major and moderate missions that are presently under study for flight sometime within the next 20 years. These programs include the: Advanced X Ray Astrophysics Facility; X Ray Schmidt Telescope; Nuclear Astrophysics Experiment; Hard X Ray Imaging Facility; Very High Throughput Facility; Gamma Ray Spectroscopy Observatory; Hubble Space Telescope; Lunar Transit Telescope; Astrometric Interferometer Mission; Next Generation Space Telescope; Imaging Optical Interferometer; Far Ultraviolet Spectroscopic Explorer; Gravity Probe B; Laser Gravity Wave Observatory in Space; Stratospheric Observatory for Infrared Astronomy; Space Infrared Telescope Facility; Submillimeter Intermediate Mission; Large Deployable Reflector; Submillimeter Interferometer; and Next Generation Orbiting Very Long Baseline Interferometer.

Swanson, Paul N.↗

Observations of winds with an incoherent lidar detector

A Fabry-Perot interferometer and image-plane detector system to be used as a receiver for a Doppler lidar have been developed. This system incorporates the latest technology in multichannel detectors, and it is an important step toward the development of operational wind profiler systems for the atmosphere. The instrumentation includes a stable high-resolution optically contacted plane etalon and a multiring anode detector to scan the image plane of the Fabry-Perot interferometer spatially. The high wavelength resolution provided by the interferometer permits the aerosol and molecular components of the backscattered signal to be distinguished, and the Doppler shift of either component can then be used to determine the wind altitude profile. The receiver performance has been tested by measuring the wind profile in the boundary layer. The Fabry-Perot interferometer and image-plane detector characteristics are described and sample measurements are presented. The potential of the system as a wind profiler in the troposphere, the stratosphere, and the mesosphere is also considered.

Abreu, Vincent J.↗

Controllable Optical Delay Line For Stellar Interferometry

Prototype optical delay line for use in Big Optical Array stellar interferometer developed by Naval Research Laboratory, is advanced version of Mark III stellar interferometer at Mt. Wilson. Several delay lines used in system; their purpose to equalize optical pathlengths from target star to beam combiner in interferometer via each of arms of interferometer. Features passive mechanical suppression of vibrations plus active control for tracking, slewing, and suppression of vibrations.

Colavita, Mark↗

Dual baseline and frequency along-track interferometry

The Jet Propulsion Laboratory (JPL) airborne synthetic aperture radar (AIRSAR) L-band along-track interferometer images currents and waves on the ocean surface. By modifying the operating procedure of this two antenna interferometer, a technique has been developed to enable interferometric measurements to be made simultaneously at two different baselines. The availability of such data allows measurement of the decorrelation process of the ocean in greater detail. The coherence time of the ocean surface can be measured at high resolution over large areas. In addition to the L-band interferometer, a C-band along-track interferometer has been developed. It allows C-band dual-baseline measurements to be made simultaneous with the L-band measurements. The dual-baseline technique and AIRSAR implementation are described, and some example data are presented.

Carande, Richard E.↗

Astronomical observatories on the Moon

The Space Exploration Initiative presents an opportunity to construct astronomical telescopes on the Moon using the infrastructure provided by the lunar outpost. Small automatically deployed telescopes can be carried on the survey missions, be deployed on the lunar surface and be operated remotely from the Earth. Possibilities for early, small optical telescopes are a zenith pointed transit telescope, a student telescope, and a 0.5 to 1 meter automatic, fully steerable telescope. After the lunar outpost is established the lunar interferometers will be constructed in an evolutionary fashion. There are three lunar interferometers which have been studied. The most ambitious is the optical interferometer with a 1 to 2 -km baseline and seven 1.5 aperture elements arranged in a 'Y' configuration with a central beam combiner. The Submillimeter interferometer would use seven, 5-m reflectors in a 'Y' or circular configuration with a 1-km baseline. The Very Low Frequency (VLF) array would operate below 30 mHz with as many as 100 elements and a 200-km baseline.

Swanson, Paul N.↗

Shear/Defocus Sensitivity of the Mid Infrared Channel (MIR) of the Composite Infrared Spectrometer (CIRS) for the Cassini Mission to Saturn

The Composite Infrared Spectrometer (CIRS) of the Cassini mission to Saturn has two interferometers covering the far infrared and mid infrared wavelength region. The mid infrared wavelength interferometer has a focal plane consisting of a germanium focus lens and HgCdTe array. System level calibration of the CIRS Flight Unit indicated a discrepancy between the expected and actual signal levels. Testing on the CIRS breadboard and Engineering Unit indicated that defocus of the germanium lens could significantly reduce the modulation efficiency of the interferometer in the presence of a moderate degree of wavefront shear. Defocus of the lens in the focal plane was of concern because of the temperature dependence of the index of refraction of germanium and our nominal operation temperature of 170 K. The shear/defocus interaction was extensively investigated and correlated to a newly developed analytical model, It was eventually determined that the CIRS instrument was in focus, had no appreciable wavefront shear and was operating near theoretical limits. The shear/defocus effect is however, of considerable interest, since it has not been described in previous literature on interferometers.

Martino, Anthony J.↗

Vertical Scales of Turbulence at the Mount Wilson Observatory

The vertical scales of turbulence at the Mount Wilson Observatory are inferred from data from the University of California at Berkeley Infrared Spatial Interferometer (ISI), by modeling path length fluctuations observed in the interferometric paths to celestial objects and those in instrumental ground-based paths. The correlations between the stellar and ground-based path length fluctuations and the temporal statistics of those fluctuations are modeled on various timescales to constrain the vertical scales. A Kolmogorov-Taylor turbulence model with a finite outer scale was used to simulate ISI data. The simulation also included the white instrumental noise of the interferometer, aperture-filtering effects, and the data analysis algorithms. The simulations suggest that the path delay fluctuations observed in the 1992-1993 ISI data are largely consistent with being generated by refractivity fluctuations at two characteristic vertical scales: one extending to a height of 45 m above the ground, with a wind speed of about 1 m/ s, and another at a much higher altitude, with a wind speed of about 10 m/ s. The height of the lower layer is of the order of the dimensions of trees and other structures near the interferometer, which suggests that these objects, including elements of the interferometer, may play a role in generating the lower layer of turbulence. The modeling indicates that the high- attitude component contributes primarily to short-period (less than 10 s) fluctuations, while the lower component dominates the long-period (up to a few minutes) fluctuations. The lower component turbulent height, along with outer scales of the order of 10 m, suggest that the baseline dependence of long-term interferometric, atmospheric fluctuations should weaken for baselines greater than a few tens of meters. Simulations further show that there is the potential for improving the seeing or astrometric accuracy by about 30%-50% on average, if the path length fluctuations in the lower component are directly calibrated. Statistical and systematic effects induce an error of about 15 m in the estimate of the lower component turbulent altitude.

Treuhaft, Robert N.↗

The Wide-Field Imaging Interferometry Testbed: Progress and Plans

We describe the technique of wide field mosaic imaging for optical/IR interferometers and present early experimental results from a laboratory instrument designed to validate, experiment with, and refine the technique. A conventional single-detector stellar interferometer operating with narrow bandwidth at center wavelength lambda is limited in its field of view to the primary beam of the individual telescope apertures, or approx. lambda/D(sub tel) radians, where is the telescope diameter. Such a field is too small for many applications; often one wishes to image extended sources. We are developing and testing a technique analogous to the mosaic method employed in millimeter and radio astronomy, but applicable to optical/IR Michelson interferometers, in which beam combination is done in the pupil plane. An N(sub pix) x N(sub pix) detector array placed in the image plane of the interferometer is used to record simultaneously the fringe patterns from many contiguous telescope fields, effectively multiplying the field size by N(sub pix)/2, where the factor 2 allows for Nyquist sampling. This mosaic imaging technique will be especially valuable for far IR and submillimeter interferometric space observatories such as the Space Infrared Interferometric Telescope (SPIRIT) and the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). SPIRIT and SPECS will be designed to provide sensitive, high angular resolution observations of fields several arcminutes in diameter, and views of the universe complementary to those provided by HST, NGST, and ALMA.

Rinehart, S. A.↗

Direct Measurement of Large, Diffuse, Optical Structures

Digital Speckle Pattern Interferometry (DSPI) is a well-established method for the measurement of diffuse objects in experimental mechanics. DSPIs are phase shifting interferometers. Three or four bucket temporal phase shifting algorithms are commonly used to provide phase shifting. These algorithms are sensitive to vibrations and can not be used to measure large optical structures far away from the interferometer. In this research a simultaneous phase shifted interferometer, PhaseCam product of 4D Technology Corporation in Tucson Arizona, is modified to be a Simultaneous phase shifted Digital Speckle Pattern Interferometer (SDSPI). Repeatability, dynamic range, and accuracy of the SDSPI are characterized by measuring a 5 cm x 5 cm carbon fiber coupon.

Saif, Babak N.↗