Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Spread Spectrum Receiver Electromagnetic Interference (EMI) Test Guide

The objective of this test guide is to document appropriate unit level test methods and techniques for the performance of EMI testing of Direct Sequence (DS) spread spectrum receivers. Consideration of EMI test methods tailored for spread spectrum receivers utilizing frequency spreading, techniques other than direct sequence (such as frequency hopping, frequency chirping, and various hybrid methods) is beyond the scope of this test guide development program and is not addressed as part of this document EMI test requirements for NASA programs are primarily developed based on the requirements contained in MIL-STD-46 1 D (or earlier revisions of MIL-STD-46 1). The corresponding test method guidelines for the MIL-STD-461 D tests are provided in MIL-STD-462D. These test methods are well documented with the exception of the receiver antenna port susceptibility tests (intermodulation, cross modulation, and rejection of undesired signals) which must be tailored to the specific type of receiver that is being tested. Thus, test methods addressed in this guide consist only of antenna port tests designed to evaluate receiver susceptibility characteristics. MIL-STD-462D should be referred for guidance pertaining to test methods for EMI tests other than the antenna port tests. The scope of this test guide includes: (1) a discussion of generic DS receiver performance characteristics; (2) a summary of S-band TDRSS receiver operation; (3) a discussion of DS receiver EMI susceptibility mechanisms and characteristics; (4) a summary of military standard test guidelines; (5) recommended test approach and methods; and (6) general conclusions and recommendations for future studies in the area of spread spectrum receiver testing.

Wheeler, M. L.↗

Personal Electronic Devices and Their Interference with Aircraft Systems

A compilation of data on personal electronic devices (PEDs) attributed to having created anomalies with aircraft systems. Charts and tables display 14 years of incidents reported by pilots to the Aviation Safety Reporting System (ASRS). Affected systems, incident severity, sources of anomaly detection, and the most frequently identified PEDs are some of the more significant data. Several reports contain incidents of aircraft off course when all systems indicated on course and of critical events that occurred during landings and takeoffs. Additionally, PEDs that should receive priority in testing are identified.

Ross, Elden↗

Design of an L-Band Microwave Radiometer with Active Mitigation of Interference

For increased sensitivity in L-band radiometry, bandwidths on the order of 100 MHz are desirable. This will likely require active countermeasures to mitigate RFI. In this paper, we describe a new radiometer which coherently samples 100 MHz of spectrum and applies real-time RFI mitigation techniques using FPGAs. A field test of an interim version of this design in a radio astronomy observation corrupted by radar pulses is described.

Ellingson, Steven W.↗

Wall Interference Study of the NTF Slotted Tunnel Using Bodies of Revolution Wall Signature Data

This paper is a description of the analysis of blockage corrections for bodies of revolution for the slotted-wall configuration of the National Transonic Facility (NTF) at the NASA Langley Research Center (LaRC). A wall correction method based on the measured wall signature is used. Test data from three different-sized blockage bodies and four wall ventilation settings were analyzed at various Mach numbers and unit Reynolds numbers. The results indicate that with the proper selection of the boundary condition parameters, the wall correction method can predict blockage corrections consistent with the wall measurements for Mach numbers as high as 0.95.

Iyer, Venkit↗

Wall Interference Study of the NTF Slotted Tunnel Using Bodies of Revolution Wall Signature Data

This paper is a description of the analysis of blockage corrections for bodies of revolution for the slotted-wall configuration of the National Transonic Facility (NTF) at the NASA Langley Research Center (LaRC). A wall correction method based on the measured wall signature is used. Test data from three different-sized blockage bodies and four wall ventilation settings were analyzed at various Mach numbers and unit Reynolds numbers. The results indicate that with the proper selection of the boundary condition parameters, the wall correction method can predict blockage corrections consistent with the wall measurements for Mach numbers as high as 0.95.

Iyer, Venkit↗

Dual-task interference with equal task emphasis: graded capacity sharing or central postponement?

Most studies using the psychological refractory period (PRP) design suggest that dual-task performance is limited by a central bottleneck. Because subjects are usually told to emphasize Task 1, however, the bottleneck might reflect a strategic choice rather than a structural limitation. To evaluate the possibility that central operations can proceed in parallel, albeit with capacity limitations, we conducted two dual-task experiments with equal task emphasis. In both experiments, subjects tended to either group responses together or respond to one task well before the other. In addition, stimulus-response compatibility effects were roughly constant across stimulus onset asynchronies (SOAs). At the short SOA, compatibility effects also carried over onto response times for the other task. This pattern of results is difficult to reconcile with the possibility that subjects share capacity roughly equally between simultaneous central operations. However, this pattern is consistent with the existence of a structural central bottleneck.

Auditory Perception↗

Contour completion through depth interferes with stereoacuity

Local disparity signals must interact in visual cortex to represent boundaries and surfaces of three-dimensional (3D) objects. We investigated how disparity signals interact in 3D contours and in 3D surfaces generated from the contours. We compared flat (single disparity) stimuli with curved (multi-disparity) stimuli. We found no consistent differences in sensitivity to contours vs. surfaces; for equivalent amounts of disparity, however, observers were more sensitive to flat stimuli than curved stimuli. Poor depth sensitivity for curved stimuli cannot be explained by the larger range of disparities present in the curved surface, nor by disparity averaging, nor by poor sensitivity to the largest disparity in the stimulus. Surprisingly, sensitivity to surfaces curved in depth was improved by removing portions of the surface and thus removing disparity information. Stimulus configuration had a profound effect on stereo thresholds that cannot be accounted for by disparity-energy models of V1 processing. We suggest that higher-level 3D contour or 3D shape mechanisms are involved.

Non-NASA Center↗

Space motion sickness medications: interference with biomedical parameters

The possibility that drugs administered to Skylab 3 (SL-3) and 4 (SL-4) crewmen for space motion sickness may have interfered with their biomedical evaluation in space was investigated. Healthy volunteers received combinations of Scopolamine/Dexedrine for four days in regimens similar to those used in these missions. Urine samples, heart rate, body temperature, mood and performance were analyzed for drug-related changes. Twenty-four hour urine samples were analyzed by the same procedures as those used to analyze the flight samples. Hormone concentrations determined included cortisol, epinephrine, norepinephrine, aldosterone and antidiuretic hormone (ADH). In addition, volume, specific gravity, osmolarity, sodium (Na), potassium (K), calcium (Ca), magnesium (Mg), chloride (Cl), inorganic phosphate, uric acid and creatinine were measured. Performance was not affected by the Scopolamine/Dexedrine. The drug combination increased daily mean heart rate (HR) significantly in all the subjects and daily mean rectal temperature (RT) in some of the subjects. A 2-4 hr phase shift in the HR circadian rhythm was also observed which indicates that internal circadian synchrony was disturbed by the drugs. Psychological and subjective evaluation indicated that the subjects could usually identify which days they were given the drugs by an increase in tension and anxiety, decreased patience, restlessness, decreased appetite, difficulty in sleeping and feelings of increased heart rate and body temperature. Urinary electrolytes were not changed significantly by the drug, but marked and significant changes occurred in urine volume and hormone excretion patterns. Scopolamine/Dexedrine caused consistent elevations in urinary cortisol and epinephrine and a transient elevation in ADH. Norepinephrine excretion was decreased, but there was no significant change in aldosterone excretion or in 24 hr urine volume. A comparison of these findings with the first four days of inflight data from the SL-3 and SL-4 missions leads to the conclusion that the dramatic increases in aldosterone excretion during the first three days of spaceflight probably can be directly attributed to weightlessness, whereas the antimotion sickness medication could have substantially contributed to the early increased excretion of epinephrine and cortisol during these missions.

manned↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

Piezoelectric Instruments of High Natural Frequency Vibration Characteristics and Protection Against Interference by Mass Forces

The exploration of the processes accompanying engine combustion demands quick-responding pressure-recording instruments, among which the piezoelectric type has found widespread use because of its especially propitious properties as vibration-recording instruments for high frequencies. Lacking appropriate test methods, the potential errors of piezoelectric recorders in dynamic measurements could only be estimated up to now. In the present report a test method is described by means of which the resonance curves of the piezoelectric pickup can be determined; hence an instrumental appraisal of the vibration characteristics of piezoelectric recorders is obtainable.

Gohlka, Werner↗

Measurements of Unsteady Wake Interference Between Tandem Cylinders

A multi-phase, experimental study in the Basic Aerodynamics Research Tunnel at the NASA Langley Research Center has provided new insight into the unsteady flow interaction around cylinders in tandem arrangement. Phase 1 of the study characterized the mean and unsteady near-field flow around two cylinders of equal diameter using 2-D Particle Image Velocimetry (PIV) and hot-wire anemometry. These measurements were performed at a Reynolds number of 1.66 x 10(exp 5), based on cylinder diameter, and spacing-to-diameter ratios, L/D, of 1.435 and 3.7. The current phase, Phase 2, augments this dataset by characterizing the surface flow on the same configurations using steady and unsteady pressure measurements and surface flow visualization. Transition strips were applied to the front cylinder during both phases to produce a turbulent boundary layer upstream of the flow separation. For these flow conditions and L/D ratios, surface pressures on both the front and rear cylinders show the effects of L/D on flow symmetry, pressure recovery, and the location of flow separation and attachment. Mean streamlines and instantaneous vorticity obtained from the PIV data are used to explain the flow structure in the gap and near-wake regions and its relationship to the unsteady surface pressures. The combination of off-body and surface measurements provides a comprehensive dataset to develop and validate computational techniques for predicting the unsteady flow field at higher Reynolds numbers.

Jenkins, Luther N.↗

Power, data latency, and radio frequnecy interference issues in Mars Realy Network scheduling

At different time periods in the future, missions to Mars will overlap. Previous studies indicate that during such periods, existing deep space communication infrastructure cannot handle all Mars communication needs. A plausible solution is to take into account the end-to-end communication performances of network along with operational constraints, and optimize the resource usage by scheduling communication at highest possible data throughputs. As a result, shorter communication time is required and more missions can be accommodated. This principle is demonstrated in this paper for a Mars relay communication network; a network consisting of multiple surface units and orbiters on Mars and the Deep Space Stations.

power latency RFI Mars Relay Network scheduling↗