Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

A large-area gamma-ray imaging telescope system

The concept definition of using the External Tank (ET) of the Space Shuttle as the basis for constructing a large area gamma ray imaging telescope in space is detailed. The telescope will be used to locate and study cosmic sources of gamma rays of energy greater than 100 MeV. Both the telescope properties and the means whereby an ET is used for this purpose are described. A parallel is drawn between those systems that would be common to both a Space Station and this ET application. In addition, those systems necessary for support of the telescope can form the basis for using the ET as part of the Space Station. The major conclusions of this concept definition are that the ET is ideal for making into a gamma ray telescope, and that this telescope will provide a substantial increase in collecting area.

Koch, D. G.↗

Multispectral microwave imaging radar for remote sensing applications

A multispectral airborne microwave radar imaging system, capable of obtaining four images simultaneously is described. The system has been successfully demonstrated in several experiments and one example of results obtained, fresh water ice, is given. Consideration of the digitization of the imagery is given and an image digitizing system described briefly. Preliminary results of digitization experiments are included.

Larson, R. W.↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗

Boundary-layer transition detection with infrared imaging emphasizing cryogenic applications

This paper reviews the technique of boundary-layer transition detection using infrared (IR) imaging, emphasizing cryogenic wind-tunnel testing. With the exception of the low-temperature effects on the IR radiation, the discussion is relevant to conventional wind-tunnel and flight testing as well. At low temperatures, IR imaging encounters a reduction in the radiated energy throughout the IR spectrum, combined with a shift to longer wavelengths of the bulk of the radiation. This radiation behavior affects the minimum resolvable temperature difference (MRTD) of the IR imaging system because of its fixed wave band sensitivity. In the absence of commercial long wavelength IR imaging systems, operating at wavelengths longer than 13 micron, some measures can be taken to alleviate the problem caused by the MRTD limitation. The thermal signature of transition can be enhanced by allowing a small and controlled temperature increase of the wind-tunnel flow that induces a transient heat transfer to the model. This action temporarily reveals the model area under the turbulent regime through its higher heating rate compared with the laminar regime. The contrast between the areas exposed to the two regimes can be enhanced by subtraction of thermograms (the equilibrium thermogram from the transient thermogram). Further visual improvement can be obtained through shade stretching or binary shading.

Gartenberg, Ehud↗

Assessment of holographic microscopy for quantifying marine particle size and concentration

Holographic microscopy has emerged as a tool for in situ imaging of microscopic organisms and other particles in the marine environment: appealing because of the relatively larger sampling volume and simpler optical configuration compared to other imaging systems. However, its quantitative capabilities have so far remained uncertain, in part because hologram reconstruction and image recognition have required manual operation. Here, we assess the quantitative skill of our automated hologram processing pipeline (CCV Pipeline), to evaluate the size and concentration measurements of environmental and cultured assemblages of marine plankton particles, and microspheres. Over 1 million particles, ranging from 10 to 200 μm in equivalent spherical diameter, imaged by the 4‐Deep HoloSea digital inline holographic microscope (DIHM) are analyzed. These measurements were collected in parallel with a FlowCam (FC), Imaging FlowCytobot (IFCB), and manual microscope identification. Once corrections for particle location and nonuniform illumination were developed and applied, the DIHM showed an underestimate in ESD of about 3% to 10%, but successfully reproduced the size spectral slope from environmental samples, and the size distribution of cultures (Dunaliella tertiolecta, Heterosigma akashiwo, and Prorocentrum micans) and microspheres. DIHM concentrations (order 1 to 1000 particles ml(exp −1)) showed a linear agreement (r(exp 2) = 0.73) with the other instruments, but individual comparisons at times had large uncertainty. Overall, we found the DIHM and the CCV Pipeline required extensive manual correction, but once corrected, provided concentration and size estimates comparable to the other imaging systems assessed in this study. Holographic cameras are mechanically simple, autonomous, can operate at very high pressures, and provide a larger sampling volume than comparable lens‐based tools. Thus, we anticipate that these characterization efforts will be rewarded with novel discovery in new oceanic environments.

Noah L. Walcutt↗

Phase-sensitive two-dimensional neutron shearing interferometer and Hartmann sensor

A neutron imaging system detects both the phase shift and absorption of neutrons passing through an object. The neutron imaging system is based on either of two different neutron wavefront sensor techniques: 2-D shearing interferometry and Hartmann wavefront sensing. Both approaches measure an entire two-dimensional neutron complex field, including its amplitude and phase. Each measures the full-field, two-dimensional phase gradients and, concomitantly, the two-dimensional amplitude mapping, requiring only a single measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral investigations of Mars from Viking

In connection with the Viking mission, spectral and photometric data of Mars were obtained with the aid of camera systems located either on the planetary surface (Lander I and II) or in Martian orbit (Orbiter I and II). Operations from Lander I are scheduled to continue through 1990. Comparisons made of the surface and atmospheric spectral and photometric properties at various times throughout the Mission were probably the most important studies conducted by the Lander cameras. The variations in atmospheric optical density due to clouds, dust storm activity (both local and global), and even a partial eclipse of the sun by the small satellite Phobos, were observed by the Lander imaging systems. Using Viking Orbiter II images, the surface materials of the equatorial region have been classified and mapped on the basis of spectral reflectance properties. Attention is also given to some details regarding the characteristics of the Viking imaging systems.

Evans, N.↗

Strong-lensing analysis of the powerful lensing cluster MACS J2135.2-0102 (z = 0.33)

We present a light-traces-mass (LTM) strong-lensing model of the massive lensing cluster MACS J2135.2-0102 (z = 0.33; hereafter MACS2135), known in part for hosting the cosmic eye galaxy lens. MACS2135 is also known to multiply lens a z = 2.3 sub-millimeter galaxy near the brightest cluster galaxy (BCG), as well as a prominent, triply imaged system at a large radius of ∼37″ south of the BCG. We use the latest available Hubble imaging to construct an accurate lensing model for this cluster, identifying six new multiply imaged systems with the guidance of our LTM method, so that we have roughly quadrupled the number of lensing constraints. We determine that MACS2135 is among the top lensing clusters known, comparable in size to the Hubble Frontier Fields. For a source at z{sub s}=2.32, we find an effective Einstein radius of θ{sub e}=27±3{sup ′′}, enclosing 1.12±0.16×10{sup 14} M{sub ⊙}. We make our lens model, including mass and magnification maps, publicly available, in anticipation of searches for high-z galaxies with the James Webb Space Telescope, for which this cluster is a compelling target.

79 ASTRONOMY AND ASTROPHYSICS↗

Smart quantum statistical imaging beyond the Abbe-Rayleigh criterion

The wave nature of light imposes limits on the resolution of optical imaging systems. For over a century, the Abbe-Rayleigh criterion has been utilized to assess the spatial resolution limits of imaging instruments. Recently, there has been interest in using spatial projective measurements to enhance the resolution of imaging systems. Unfortunately, these schemes require a priori information regarding the coherence properties of “unknown” light beams and impose stringent alignment conditions. Here, we introduce a smart quantum camera for superresolving imaging that exploits the self-learning features of artificial intelligence to identify the statistical fluctuations of unknown mixtures of light sources at each pixel. This is achieved through a universal quantum model that enables the design of artificial neural networks for the identification of photon fluctuations. Our protocol overcomes limitations of existing superresolution schemes based on spatial mode projections, and consequently provides alternative methods for microscopy, remote sensing, and astronomy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Solar full-disk magnetic field image receiving system and observation software

The paper introduces terminal hardware system of 10 cm high resolution full-disk magnetic field telescope among solar multi-channel telescope produced by Beijing Astronomical Observatory, and its software procedure by using imaging processing as well real time data collecting. These data were processed by Sun Workstation 470/4, including doing some spectrum analysis, the system is unique in the world now. It uses a set of CCD (1320 pixels plus 1035 pixels) of high resolution image explosion, also it has a set of fast and high resolution (1024 pixel plus 1024 pixel) image processor. Moreover, we can obtain higher time and space resolution about solar full-disk magnetic field and velocity field. This will provide excellent means in observation and studies of full-disk solar large-scale magnetic field and velocity field.

Xu, Yan↗

NCTM workshop splinter session, IR thermal measurement instruments

The splinter session dealing with commercial industrial thermal measurement state-of-the-hardware had a total attendance of 15. Two papers were presented in the splinter session as follows: (1) Development of an Infrared Imaging System for the Surface Tension Driven Convection Experiment, Alexander D. Pline, NASA LeRC; (2) A Space-qualified PtSi Thermal Imaging System, Robert W. Astheimer, Barnes Engineering Div., EDO Corp. In addition a brief description of SPRITE detector technology was presented by Richard F. Leftwich of Magnovox. As anticipated, the discussions were concerned mainly with thermal imaging figures of merit rather than those for point measurement instruments. The need for uniform guidelines whereby infrared thermal imaging instruments could be specified and evaluated was identified as most important, particularly where temperature measurements are required. Presently there are differences in the way different manufacturers present significant performance parameters in their instrument data sheets. Furthermore, the prospective user has difficulty relating these parameters to actual measurement needs, and procedures by which performance can be verified are poorly defined. The current availability of powerful thermal imaging diagnostic software was discussed.

Kaplan, Herbert↗

NASA Tech Briefs, May 2007

Topics include: Noise-Canceling Helmet Audio System; Program Analyzes Spacecraft/Ground Radio Links; Two-Way Communication Using RFID Equipment and Techniques; Six-Message Electromechanical Display System; Scanning Terahertz Heterodyne Imaging Systems; Master Clock and Time-Signal-Distribution System; Synchronous Phase-Resolving Flash Range Imaging; Integrated Radial Probe Transition From MMIC to Waveguide; Bar-Code System for a Microbiological Laboratory; MMIC Amplifier Produces Gain of 10 dB at 235 GHz; Mapping Nearby Terrain in 3D by Use of a Grid of Laser Spots; Digital Beam Deflectors Based Partly on Liquid Crystals; Narrow-Band WGM Optical Filters With Tunable FSRs; Better Finite-Element Analysis of Composite Shell Structures; Computing Spacecraft-Pointing Vectors for Limb Tracking; Enhanced Master Controller Unit Tester; Rover Graphical Simulator; Increasing Durability of Flame-Sprayed Strain Gauges; Multifunctional, High-Temperature Nanocomposites; Multilayer Impregnated Fibrous Thermal Insulation Tiles; Radiation-Shielding Polymer/Soil Composites; Film/Adhesive Processing Module for Fiber-Placement Processing of Composites; Fabrication of Submillimeter Axisymmetric Optical Components; Electrochemical Disposal of Hydrazines in Water; Statistical Model of Evaporating Multicomponent Fuel Drops; Resistively Heated SiC Nozzle for Generating Molecular Beams; Compact Packaging of Photonic Millimeter-Wave Receiver; Diffractive Combiner of Single-Mode Pump Laser-Diode Beams; Wide-Band, High-Quantum-Efficiency Photodetector; A Robustly Stabilizing Model Predictive Control Algorithm; Modeling Evaporation of Drops of Different Kerosenes; Development of Vapor-Phase Catalytic Ammonia Removal System; Several Developments in Space Tethers; Design Concept for a Nuclear Reactor-Powered Mars Rover; Formation-Initialization Algorithm for N Spacecraft; and DNSs of Multicomponent Gaseous and Drop-Laden Mixing Layers Achieving Transition to Turbulence.

Source record↗

High-speed multi-frame dynamic transmission electron microscope image acquisition system with arbitrary timing

An electron microscope is disclosed which has a laser-driven photocathode and an arbitrary waveform generator (AWG) laser system ("laser"). The laser produces a train of temporally-shaped laser pulses each being of a programmable pulse duration, and directs the laser pulses to the laser-driven photocathode to produce a train of electron pulses. An image sensor is used along with a deflector subsystem. The deflector subsystem is arranged downstream of the target but upstream of the image sensor, and has a plurality of plates. A control system having a digital sequencer controls the laser and a plurality of switching components, synchronized with the laser, to independently control excitation of each one of the deflector plates. This allows each electron pulse to be directed to a different portion of the image sensor, as well as to enable programmable pulse durations and programmable inter-pulse spacings.

36 MATERIALS SCIENCE↗

Identification of an interstellar oxide grain from the Murchison meteorite by ion imaging

We report here the first use of a new ion-imaging system to locate a rare interstellar aluminum oxide grain in a Murchison acid residue. While several types of carbon-rich interstellar grains, including graphite, diamond, SiC, and TiC, have previously been found, isotopically anomalous interstellar oxide grains have proven more elusive. We have developed an ion imaging system which allows us to map the isotopic composition of large numbers of grains relatively quickly and is, thus, ideally suited to search for isotopically exotic subsets of grains. The system consists of a PHOTOMETRICS CCD camera coupled to the microchannel plate/fluorescent screen of the WU modified CAMECA IMS-3F ion microprobe. Isotopic images of the sample surface are focused on the CCD and digitized. Subsequent image processing identifies individual grains in the images and determines isotopic ratios for each. For the present work, we have imaged in O-16 and O-18; negligible contributions of (17)OH(-) and (16)OH2(-) signals to the O-18 signal allow the use of low mass resolution, simplifying the measurements. Repeated imaging runs on terrestrial corundum particles showed that the system measures isotopic ratios reproducibly to about +/- 40%. Each imaging run took about six minutes to complete, and for this study there were on average 5-15 grains in each image. We have conducted imaging searches in 2-4 micron size separates of both Orgueil and Murchison.

Nittler, L. R.↗

Ultrathin Optics for Low-Profile Innocuous Imager

This project demonstrates the feasibility of a novel imager with a thickness measured in microns rather than inches. Traditional imaging systems, i.e. cameras, cannot provide both the necessary resolution and innocuous form factor required in many data acquisition applications. Designing an imaging system with an extremely thin form factor (less than 1 mm) immediately presents several technical challenges. For instance, the thickness of the optical lens must be reduced drastically from currently available lenses. Additionally, the image circle is reduced by a factor equal to the reduction in focal length. This translates to fewer detector pixels across the image. To reduce the optical total track requires the use of specialized micro-optics and the required resolution necessitates the use of a new imaging modality. While a single thin imager will not produce the desired output, several thin imagers can be multiplexed and their low resolution (LR) outputs used together in post-processing to produce a high resolution (HR) image. The utility of an Iterative Back Projection (IBP) algorithm has been successfully demonstrated for performing the required post-processing. Advanced fabrication of a thin lens was also demonstrated and experimental results using this lens as well as commercially available lenses are presented.

47 OTHER INSTRUMENTATION↗

TU-A-9A-07: X-Ray Acoustic Computed Tomography (XACT): 100% Sensitivity to X-Ray Absorption

Purpose: To assess whether X-ray acoustic computed tomography (XACT) is more sensitive to X-ray absorption than that of the conventional X-ray imaging. Methods: First, a theoretical model was built to analyze the X-ray absorption sensitivity of XACT imaging and conventional X-ray imaging. Second, an XACT imaging system was developed to evaluate the X-ray induced acoustic signal generation as well as the sensitivity improvement over transmission x-ray imaging. Ultra-short x-ray pulses (60-nanosecond) were generated from an X-ray source operated at the energy of 150 kVp with a 10-Hz repetition rate. The X-ray pulse was synchronized with the acoustic detection via a x-ray scintillation triggering to acquire the X-ray induced acoustic signal. Results: Theoretical analysis shows that X-ray induced acoustic signal is sensitive only to the X-ray absorption, while completely insensitive to out the X-ray scattering and fluorescence. XACT has reduced background and increased contrast-to-noise ratio, and therefore has increased sensitivity compared to transmission x-ray imaging. For a 50-μm size, gadolinium insertion in tissue exposed to 40 keV X-rays; the sensitivity of XACT imaging is about 28.9 times higher than that of conventional X-ray imaging. Conclusion: X-ray acoustic computer tomography (XACT) as a new imaging modality combines X-ray absorption contrast and high ultrasonic resolution in a single modality. It is feasible to improve the imaging sensitivity with XACT imaging compared with conventional X-ray imaging. Taking advantage of the high ultrasonic resolution, it is possible to perform 3-D imaging with a single x-ray pulse with arrays of transducers without any mechanical motion of the imaging system. This single-shot capability offers the potential of reducing radiation dose by a factor of 1000, and imaging 100 times faster when compared to the conventional X-ray CT, and thus revolutionizing x-ray imaging applications in medicine and biology. The authors gratefully acknowledge the Department of Defense Prostate Cancer Research Programs W81XWH-13-1-0481 (LX), the National Institutes of Health 1R01 CA133474 and 1R21 A153587, and SRFDP (20124407120012) for funding.

60 APPLIED LIFE SCIENCES↗

A visible light terrestrial planet finder - planet detection and spectroscopy by nulling interferometry with a single aperture telescope

Planet detection around a bright star depends the resolution of the imaging system and the degree of light suppression of the star relative to the planet. We present a concept for a visible light Terrestrial Planet Finding (VTPF) mission. Its major feature is an imaging system for planet detection using a nulling interferometer behind a single aperture telescope. This configuration is capable of detecting earth-like planets with a 5m aperture using both imaging and spectroscopic imaging modes. We will describe the principles of the system, and show results of studies demonstrating its feasibility.

planet↗