Terascale direct numerical simulations of turbulent combustion using S3D
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Reduction-oxidation (redox) reactions are the key processes that underlie the batteries powering smartphones, laptops, and electric cars. A redox process involves transfer of electrons between two species. For example, in a lithium-ion battery, current is generated when conduction electrons from the lithium anode are transferred to the redox orbitals of the cathode material. The ability to visualize or image the redox orbitals and how these orbitals evolve under lithiation and delithiation processes is thus of great fundamental and practical interest for understanding the workings of battery materials. In this study, we show that inelastic scattering spectroscopy using high-energy x-ray photons (Compton scattering) can yield faithful momentum space images of the redox orbitals by considering lithium iron phosphate (LiFePO 4 or LFP) as an exemplar cathode battery material. Our analysis reveals a new link between voltage and the localization of transition metal 3d orbitals and provides insight into the puzzling mechanism of potential shift and how it is connected to the modification of the bond between the transition metal and oxygen atoms. Our study thus opens a novel spectroscopic pathway for improving the performance of battery materials.
Green buildings that fail to meet expected design performance criteria indicate that technology alone does not guarantee high performance. Human influences are quite often simplified and ignored in the design, construction, and operation of buildings. Energy-conscious human behavior has been demonstrated to be a significant positive factor for improving the indoor environment while reducing the energy use of buildings. In our study we developed a new technical framework to describe energy-related human behavior in buildings. The energy-related behavior includes accounting for individuals and groups of occupants and their interactions with building energy services systems, appliances and facilities. The technical framework consists of four key components: i. the drivers behind energy-related occupant behavior, which are biological, societal, environmental, physical, and economical in nature ii. the needs of the occupants are based on satisfying criteria that are either physical (e.g. thermal, visual and acoustic comfort) or non-physical (e.g. entertainment, privacy, and social reward) iii. the actions that building occupants perform when their needs are not fulfilled iv. the systems with which an occupant can interact to satisfy their needs The technical framework aims to provide a standardized description of a complete set of human energy-related behaviors in the form of an XML schema. For each type of behavior (e.g., occupants opening/closing windows, switching on/off lights etc.) we identify a set of common behaviors based on a literature review, survey data, and our own field study and analysis. Stochastic models are adopted or developed for each type of behavior to enable the evaluation of the impact of human behavior on energy use in buildings, during either the design or operation phase. We will also demonstrate the use of the technical framework in assessing the impact of occupancy behavior on energy saving technologies. The technical framework presented is part of our human behavior research, a 5-year program under the U.S. - China Clean Energy Research Center for Building Energy Efficiency.
The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.
The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.
The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.
The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.
Integrating 20% or more wind energy into the system and transmitting large sums of wind energy over long distances will require a decision making capability that can handle very large scale power systems with tens of thousands of buses and lines. There is a need to explore innovative analytical and implementation solutions for continuing reliable operations with the most economical integration of additional wind energy in power systems. A number of wind integration solution paths involve the adoption of new operating policies, dynamic scheduling of wind power across interties, pooling integration services, and adopting new transmission scheduling practices. Such practices can be examined by the decision tool developed by this project. This project developed a very efficient decision tool called Wind INtegration Simulator (WINS) and applied WINS to facilitate wind energy integration studies. WINS focused on augmenting the existing power utility capabilities to support collaborative planning, analysis, and wind integration project implementations. WINS also had the capability of simulating energy storage facilities so that feasibility studies of integrated wind energy system applications can be performed for systems with high wind energy penetrations. The development of WINS represents a major expansion of a very efficient decision tool called POwer Market Simulator (POMS), which was developed by IIT and has been used extensively for power system studies for decades. Specifically, WINS provides the following superiorities; (1) An integrated framework is included in WINS for the comprehensive modeling of DC transmission configurations, including mono-pole, bi-pole, tri-pole, back-to-back, and multi-terminal connection, as well as AC/DC converter models including current source converters (CSC) and voltage source converters (VSC); (2) An existing shortcoming of traditional decision tools for wind integration is the limited availability of user interface, i.e., decision results are often text-based demonstrations. WINS includes a powerful visualization tool and user interface capability for transmission analyses, planning, and assessment, which will be of great interest to power market participants, power system planners and operators, and state and federal regulatory entities; and (3) WINS can handle extended transmission models for wind integration studies. WINS models include limitations on transmission flow as well as bus voltage for analyzing power system states. The existing decision tools often consider transmission flow constraints (dc power flow) alone which could result in the over-utilization of existing resources when analyzing wind integration. WINS can be used to assist power market participants including transmission companies, independent system operators, power system operators in vertically integrated utilities, wind energy developers, and regulatory agencies to analyze economics, security, and reliability of various options for wind integration including transmission upgrades and the planning of new transmission facilities. WINS can also be used by industry for the offline training of reliability and operation personnel when analyzing wind integration uncertainties, identifying critical spots in power system operation, analyzing power system vulnerabilities, and providing credible decisions for examining operation and planning options for wind integration. Researches in this project on wind integration included (1) Development of WINS; (2) Transmission Congestion Analysis in the Eastern Interconnection; (3) Analysis of 2030 Large-Scale Wind Energy Integration in the Eastern Interconnection; (4) Large-scale Analysis of 2018 Wind Energy Integration in the Eastern U.S. Interconnection. The research resulted in 33 papers, 9 presentations, 9 PhD degrees, 4 MS degrees, and 7 awards. The education activities in this project on wind energy included (1) Wind Energy Training Facility Development; (2) Wind Energy Course Development.
Abstract. Bentonite buffer in a geological repository will be simultaneously heated from decaying radioactive waste and hydrated from the surrounding host rock, triggering complex and coupled THMC (thermal–hydrological–mechanical–chemical) processes. Understanding the THMC behavior of bentonite-based engineered barrier system (EBS) is key to the evaluation and prediction of its long-term performance. Studies on the THMC process have been focused on conditions under 100 ∘C, as most design concepts impose a thermal limit of 100 ∘C in bentonite. Recently, studies under high-temperature conditions have been conducted to evaluate the possibility of raising the thermal limit and expanding the data/knowledge base to increase the confidence level. In this abstract, we present a series of bench-scale laboratory experiments at high temperatures (up to 200 ∘C) and the corresponding modeling work. Two sets of column tests were conducted, and each set consisted of two test columns: a control column undergoing only hydration (non-heated) and an experiment column experiencing both heating and hydration (heated). During the experiment, frequent X-ray computed tomography (CT) images were collected to provide a 3D visualization of the density distribution and present the spatiotemporal evolution of (1) hydration/dehydration, (2) clay swelling/shrinkage, (3) displacement, and (4) mineral precipitation. The two sets of tests differ with respect to several experimental conditions, such as bentonite type, compacted density and water content, water chemistry, and hydration pressure, but the important difference is that the first set used bentonite powder with a dry density of 1.28 g cm−3, whereas the second set used granulated bentonite (mixture of pellets and powder) with a dry density of 1.45–1.5 g cm−3. In both sets of experiments, a comprehensive post-dismantling characterization of bentonite samples was carried out after the column tests had been running for 1.5 years. Comparing non-heated and heated columns, the temperature gradient led to lower degree of homogenization of bentonite after bentonite became fully saturated; comparing the first and second sets, granulated and powdered bentonite exhibited drastically different hydration behavior. A THM model with a 2D axisymmetric grid system was used to interpret the data from the first set of tests. The model considers the combined impact of saturation, fluid pressure, and porosity change due to swelling/compression on the spatiotemporal distribution of bulk density and movement of the thermocouple modules. Observations from the tests help us understand the early perturbation of bentonite buffer under high temperature, and data from these tests improve the calibration of key constitutive hydrological and mechanical models and, therefore, enhance the modeling capability with respect to calculating the long-term evolution of bentonite buffer.
Studying neuronal activity at synapses requires high spatiotemporal resolution. For high spatial resolution in vivo imaging at depth, adaptive optics (AO) is required to correct sample-induced aberrations. To improve temporal resolution, Bessel focus has been combined with two-photon fluorescence microscopy (2PFM) for fast volumetric imaging at subcellular lateral resolution. To achieve both high-spatial and high-temporal resolution at depth, we develop an efficient AO method that corrects the distorted wavefront of Bessel focus at the objective focal plane and recovers diffraction-limited imaging performance. Applying AO Bessel focus scanning 2PFM to volumetric imaging of zebrafish larval and mouse brains down to 500 µm depth, we demonstrate substantial improvements in the sensitivity and resolution of structural and functional measurements of synapses in vivo. This enables volumetric measurements of synaptic calcium and glutamate activity at high accuracy, including the simultaneous recording of glutamate activity of apical and basal dendritic spines in the mouse cortex.
Managing computational complexity and designing effective visual representations are two important challenges for the visualization of large, complex, high-dimensional datasets. Parallel coordinates are an effective technique for visualizing high- dimensional data, but do not scale well to very large datasets. The addition of the temporal dimension leads to more uncertainty due to clutter on screen. Consequently, this poses a significant challenge for visually finding trends and patterns that maximize insight about the underlying time-varying properties of the data. To address these problems, we present meta parallel coordinates, a parallel coordinates display that is guided by perceptually mo- tivated visual metrics. These metrics describe the visual structures typically found in parallel coordinates and thus aid the user’s analysis by providing meaningful views of the data. Since they are computed in screen space, our metrics are computationally more efficient than data-based metrics. Our choice of metrics is driven by the different analytical tasks that a user typically wants to perform with time-varying multivariate data. In particular, we have worked with domain scientists who performed simulations of bioremediation experiments, and use their data and results to demonstrate the usefulness of our approach
The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO 4 - in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases [Shuh, et al., 1994, Shuh, et al., 2000, Shuh, et al., 2003]. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O 4 - , which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function of depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate was used as a non-radioactive surrogate for pertechnetate in simulated waste form samples. Depth discrete subsamples were cut from material exposed to Savannah River Site (SRS) field cured conditions. The subsamples were prepared and analyzed for both reduction capacity and chromium leachability. Results from field-cured samples indicate that the depth at which leachable chromium was detected advanced further into the sample exposed for 302 days compared to the sample exposed to air for 118 days (at least 50 mm compared to at least 20 mm). Data for only two exposure time intervals is currently available. Data for additional exposure times are required to develop an equation for the oxidation front progression. Reduction capacity measurements (per the Angus-Glasser method, which is a measurement of the ability of a material to chemically reduce Ce(IV) to Ce(III) in solution) performed on depth discrete samples could not be correlated with the amount of chromium leached from the depth discrete subsamples or with the oxidation front inferred from soluble chromium (i.e., effective Cr oxidation front). Exposure to oxygen (air or oxygen dissolved in water) results in the release of chromium through oxidation of Cr(III) to highly soluble chromate, Cr(VI). Residual reduction capacity in the oxidized region of the test samples indicates that the remaining reduction capacity is not effective in re-reducing Cr(VI) in the presence of oxygen. Consequently, this method for determining reduction capacity may not be a good indicator of the effective contaminant oxidation rate in a relatively porous solid (40 to 60 volume percent porosity). The chromium extracted in depth discrete samples ranged from a maximum of about 5.8 % at about 5 mm (118 day exposure) to about 4 % at about 10 mm (302 day exposure). The use of reduction capacity as an indicator of long-term performance requires further investigation. The carbonation front was also estimated to have advanced to at least 28 mm in 302 days based on visual observation of gas evolution during acid addition during the reduction capacity measurements. Depth discrete sampling of materials exposed to realistic conditions in combination with short term leaching of crushed samples has potential for advancing the understanding of factors influencing performance and will support conceptual model development.
A laser scattering based imaging technique is utilized in order to visualize the aerosol droplets in an inductively coupled plasma (ICP) torch from an aerosol source to the site of analytical measurements. The resulting snapshots provide key information about the spatial distribution of the aerosol introduced by direct and indirect injection devices: 1) a direct injection high efficiency nebulizer (DIHEN); 2) a large-bore DIHEN (LB-DIHEN); and 3) a PFA microflow nebulizer with a PFA Scott-type spray chamber. Moreover, particle image velocimetry (PIV) is used to study the in-situ behavior of the aerosol before interaction with, for example, plasma, while the individual surviving droplets are explored by particle tracking velocimetry (PTV). Further, the velocity distribution of the surviving droplets demonstrates the importance of the initial droplet velocities in complete desolvation of the aerosol for optimum analytical performance in ICP spectrometries. These new observations are important in the design of the next-generation direct injection devices for lower sample consumption, higher sensitivity, lower noise levels, suppressed matrix effects, and for developing smart spectrometers. For example, a controller can be provided to control the output of the aerosol source by controlling the configuration of the source or the gas flow rate via feedback information concerning the aerosol.
The primary goal of the sensor suite is to provide an internal 3D map of the HCAEX tunnel. When looking for a sensor that would provide XYZ point cloud data for mapping the decision was between a stereo camera, a 3D Lidar, or a 2D Lidar that would need to be spun around. The issues with the stereo camera were that it does not have a large field-of-view and that its depth information was not nearly as accurate as even the baseline Lidars. The selection between Lidars is detailed. The Hokuyo UTM-30LX-EW shown provides a 270 deg. FOV with high accuracy and resolution while the largest FOV on a 3D Lidar is 40 deg.. This was the reason a 2D Lidar was chosen over the 3D Lidar. Even though the 2D Lidar requires additional components and software to generate a 3D map, its FOV advantage is too great given that the HCAEX tunnel is a relatively confined space. The rotating planar scan from the 2D Lidar can be stitched into a 3D scan as shown in the graphic below. Along with XYZ data, the Lidar provides return intensity data in color which can be used to distinguish between different materials within the tunnel. To provide visual feedback a camera system needed to be identified. The common solution for this is a high resolution camera with a small FOV mounted on a pan-tilt system. But, given the critical nature of the visual feedback we looked into solutions without the need for moving parts. Two panospheric cameras give a FOV large enough to get a full 360 deg. view.. Camera color data (RGB) can also be combined with the 3D mapping data from the Lidar and overlaid on the map to give the user the ability to see inside the entire length of the tunnel as if they were inside. Situational awareness is required for the crawler in the tunnel in order for it to be able to register the 3D scans to create a final map. For this we procured a Microstrain 3DM-GX5-25 Inertial Measurement Unit (IMU). To perform the Lidar rotation we have two servos driving the pan and tilt. The servo controls and most data processing will be performed via an onboard computer. The sensor components are to be packaged together using 3D printed mounts into a standalone unit.
Computational science is paramount to the understanding of underlying processes in internal combustion engines of the future that will utilize non-petroleum-based alternative fuels, including carbon-neutral biofuels, and burn in new combustion regimes that will attain high efficiency while minimizing emissions of particulates and nitrogen oxides. Next-generation engines will likely operate at higher pressures, with greater amounts of dilution and utilize alternative fuels that exhibit a wide range of chemical and physical properties. Therefore, there is a significant role for high-fidelity simulations, direct numerical simulations (DNS), specifically designed to capture key turbulence-chemistry interactions in these relatively uncharted combustion regimes, and in particular, that can discriminate the effects of differences in fuel properties. In DNS, all of the relevant turbulence and flame scales are resolved numerically using high-order accurate numerical algorithms. As a consequence terascale DNS are computationally intensive, require massive amounts of computing power and generate tens of terabytes of data. Recent results from terascale DNS of turbulent flames are presented here, illustrating its role in elucidating flame stabilization mechanisms in a lifted turbulent hydrogen/air jet flame in a hot air co-flow, and the flame structure of a fuel-lean turbulent premixed jet flame. Computing at this scale requires close collaborations between computer and combustion scientists to provide optimized scaleable algorithms and software for terascale simulations, efficient collective parallel I/O, tools for volume visualization of multiscale, multivariate data and automating the combustion workflow. The enabling computer science, applied to combustion science, is also required in many other terascale physics and engineering simulations. In particular, performance monitoring is used to identify the performance of key kernels in the DNS code, S3D and especially memory intensive loops in the code. Through the careful application of loop transformations, data reuse in cache is exploited thereby reducing memory bandwidth needs, and hence, improving S3D's nodal performance. To enhance collective parallel I/O in S3D, an MPI-I/O caching design is used to construct a two-stage write-behind method for improving the performance of write-only operations. The simulations generate tens of terabytes of data requiring analysis. Interactive exploration of the simulation data is enabled by multivariate time-varying volume visualization. The visualization highlights spatial and temporal correlations between multiple reactive scalar fields using an intuitive user interface based on parallel coordinates and time histogram. Finally, an automated combustion workflow is designed using Kepler to manage large-scale data movement, data morphing, and archival and to provide a graphical display of run-time diagnostics.
A vertical shock tube is used to perform experiments on the Richtmyer–Meshkov instability with a three-dimensional random initial perturbation. A membraneless flat interface is formed by opposed gas flows in which the light and heavy gases enter the shock tube from the top and from the bottom of the shock tube driven section. An air/SF6 gas combination is used and a Mach number M = 1.2 incident shock wave impulsively accelerates the interface. Initial perturbations on the interface are created by vertically oscillating the gas column within the shock tube to produce Faraday waves on the interface resulting in a short wavelength, three-dimensional perturbation. Planar Mie scattering is used to visualize the flow in which light from a laser sheet is scattered by smoke seeded in the air, and image sequences are captured using three high-speed video cameras. Measurements of the integral penetration depth prior to reshock show two growth behaviors, both having power law growth with growth exponents in the range found in previous experiments and simulations. Following reshock, all experiments showvery consistent linear growth with a growth rate in good agreement with those found in previous studies.
Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.
U.S. Department of Energy (DOE) sites have accumulated years of data and millions of spatial and temporal records related to the hydrological cycle, contaminant transport, and parameters of remediation technologies. In addition, numerical models which use field monitoring data to help understand flow and transport produce gigabytes of computed spatial and temporal data for each computation node. There is a need therefore for an advanced spatial data structure that can be used to address the management, processing, and analysis of spatial and temporal numerical modeling data derived from multiple sources. This can be accomplished using a geo-database. The development of an ArcSDE geo-database facilitates the centralized storage, backup, accessibility, organization, and management of model configuration and computed simulation data, putting it into a structured, coherent, and logical computer-supported system. GIS data processing and automation would enable faster and hence more complex analyses of field test data. The Applied Research Center (ARC) at Florida International University (FIU) has provided analysis of flow and transport for several watersheds at DOE's Oak Ridge Reservation (ORR), including East Fork Poplar Creek (EFPC), Upper EFPC in the Y-12 National Security Complex area (Y-12 NSC) and White Oak Creek (WOC). Integrated surface and subsurface flow, fate and transport models were developed to provide analysis of contaminant patterns within each watershed. In addition, digital monitoring data available from the Oak Ridge Environmental Information System (OREIS) related to mercury (Hg) contamination and remediation within these watersheds was used for calibration and verification of the model. Experimental studies were also carried out which provided kinetic and equilibrium data about important parameters related to Hg transport, speciation and methylation/demethylation kinetics within the watershed. Geographic Information Systems (GIS) technology was employed to support the modeling work through storage and geo-processing of spatial and temporal data required by the models and to produce hydrogeological maps for visualization. An ArcGIS geo-database was developed for centralized storage and management of experimental and computed model data and its capabilities were extended over the years using tools such as ModelBuilder combined with Python scripting to automate repetitive tasks, perform statistical analyses and generate maps and reports. The hydrologic geo-database model developed possesses a structure that enables linkage with scalable hydrologic modeling tools/applications to model hydrologic systems, and in this case, enables the testing of the potential impacts of various remediation scenarios on the ORR watersheds. The ArcSDE geo-database can also be used to automate and simplify the process of calling stored GIS and time series data. This geo-database can serve as a tool for contaminant flow and transport analyses which require large amounts of high-quality spatial and temporal data in order to ensure reliability and validity of modeling results. The existing geo-database structure developed for the hydrological modeling at ORR was designed to be replicable for application at other DOE sites. An investigation of downloadable free/open source GIS software along with required security protocols to facilitate online querying of the database was also conducted to determine methods by which project-derived data can be more easily shared with other project stakeholders such as DOE personnel and site contractors. (authors)