At least 1,045 records · Page 58

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Capillary-Enhanced Two-Phase Micro-Cooler Using Copper-Inverse-Opal Wick with Silicon Microchannel Manifold for High-Heat-Flux Cooling Application

In this work, we demonstrate a two-phase capillary-fed boiling micro-cooler that consists of a ~ 25-..mu..m-thick copper inverse opal (CIO) porous wicking structure for high-heat-flux boiling and a silicon 3D-manifold for distributed liquid delivery and vapor extraction across a 0.5 cm x 0.5 cm heated area. At low inlet water mass flow rates of 1.5 to 1.9 g(min)-1, the micro-cooler displays nearly two-phase boiling with exit vapor quality ~ 1 and a high critical heat flux (CHF) of 253 to 320 W cm-2 with low superheat of ~ 10 degrees C resulting in a thermal resistance of boiling ~ 0.025 cm2 degrees C W-1 or heat transfer coefficient of 0.4 MW m-2 degrees C-1. For higher flow rates of 5, 10, and 15 g(min)-1, the micro-cooler exhibits a hybrid single-phase and two-phase cooling regime where the contribution of the sensible heat (single-phase) cooling is linearly added to that of the two-phase cooling. For the highest flow rate of 15 g(min)-1, the CHF is increased to ~ 500 W cm-2 resulting in an overall thermal resistance of ~ 0.18 cm2 degrees C W-1. However, the two-phase heat transfer effectiveness, which estimates the utilization level of the inlet mass flow rate for two-phase boiling, is reduced to ~ 0.11. To achieve the best cooling system performances, the micro-cooler must operate entirely within the two-phase boiling regime (exit vapor quality or two-phase heat transfer effectiveness ~ 1). Ideally, the "coolant" should be delivered near its saturation temperature (~ 100 degrees C for water), which provides significant advantages for the energy-efficient operation of data centers and power electronics. We present detailed analysis with Infrared and high speed camera images at various inlet flow rates and heat fluxes to understand complex heat transfer in the micro-cooler. Furthermore, a conjugate thermofluidic simulation model, which incorporates the physics of capillary-fed boiling in a porous copper layer, agrees well with the experimental data.

capillary-enhanced boiling↗

Revisiting Recent U.S. Heat Waves in a Warmer and More Humid Climate

The frequency and intensity of heat waves in the United States is projected to increase in the 21st century. We investigate dry and humid heat waves in a pair of high-resolution model simulations that constrain large-scale atmospheric circulation, to isolate the thermodynamic impacts on characteristics of present and future heat waves over the United States. The two kinds of heat waves show differences in mean intensity, amplitude, duration, and frequency over the Southeast, Northeast, and Midwest, while their characteristics are largely similar in the drier central and western United States. In a warmer climate, relative humidity is projected to decrease during dry heat waves, whereas it remains unchanged during humid heat waves. However, the overall increase in daily maximum temperature intensifies the heat stress during future humid and dry heat waves across all regions. With large-scale circulation constrained, these simulations emphasize the importance of thermodynamic drivers in determining future heat wave characteristics.

54 ENVIRONMENTAL SCIENCES↗

Observations of Subduction, Downward Heat Flux and Dense Filament Collapse in the Northern Gulf of Mexico

Submesoscale processes are important contributors to the global heat budget and generally support upward heat transport through restratification. However, in salinity‐stratified regions, such as the northern Gulf of Mexico with its influx of freshwater from the Mississippi‐Atchafalaya river system, temperature can act like a passive tracer and submesoscale processes can contribute to downward heat transport. Oceanic heat content is a factor in many environmental risks the region faces, for example, hurricane intensification, and marine heatwaves. During the 2022 field campaign of the Submesoscales Under Near‐Resonant Inertial Shear Experiment, a sampling plan was developed to study such submesoscale processes in high resolution. Over 31 hr, four assets (two research ships and two remotely controlled boats) drove in parallel across a dense filament, capturing its evolution in time and space. The observations show that surface waters, warmed by daytime solar radiation, were subducted and that the associated overturning circulation transported heat below the surface layer where it was later irreversibly mixed away. The estimated downward heat flux was as strong as the concurrent net air‐sea heat flux into the ocean. The filament was then observed to rapidly collapse which we attribute to boundary layer turbulence and the breakdown of geostrophic balance. The collapsing fronts display behaviors indicative of gravity currents. These observations highlight how in salinity‐stratified regions, frontal dynamics can be associated with downward heat flux and how the submesoscale can play an important role in the oceanic heat budget.

58 GEOSCIENCES↗

An introduction to Spent Nuclear Fuel decay heat for Light Water Reactors: a review from the NEA WPNCS

This paper summarized the efforts performed to understand decay heat estimation from existing spent nuclear fuel (SNF), under the auspices of the Working Party on Nuclear Criticality Safety (WPNCS) of the OECD Nuclear Energy Agency. Needs for precise estimations are related to safety, cost, and optimization of SNF handling, storage, and repository. The physical origins of decay heat (a more correct denomination would be decay power) are then introduced, to identify its main contributors (fission products and actinides) and time-dependent evolution. Due to limited absolute prediction capabilities, experimental information is crucial; measurement facilities and methods are then presented, highlighting both their relevance and our need for maintaining the unique current full-scale facility and developing new ones. The third part of this report is dedicated to the computational aspect of the decay heat estimation: calculation methods, codes, and validation. Different approaches and implementations currently exist for these three aspects, directly impacting our capabilities to predict decay heat and to inform decision-makers. Finally, recommendations from the expert community are proposed, potentially guiding future experimental and computational developments. One of the most important outcomes of this work is the consensus among participants on the need to reduce biases and uncertainties for the estimated SNF decay heat. If it is agreed that uncertainties (being one standard deviation) are on average small (less than a few percent), they still substantially impact various applications when one needs to consider up to three standard deviations, thus covering more than 95% of cases. The second main finding is the need of new decay heat measurements and validation for cases corresponding to more modern fuel characteristics: higher initial enrichment, higher average burnup, as well as shorter and longer cooling time. Similar needs exist for fuel types without public experimental data, such as MOX, VVER, or CANDU fuels. A third outcome is related to SNF assemblies for which no direct validation can be performed, representing the vast majority of cases (due to the large number of SNF assemblies currently stored, or too short or too long cooling periods of interest). A few solutions are possible, depending on the application. For the final repository, systematic measurements of quantities related to decay heat can be performed, such as neutron or gamma emission. This would provide indications of the SNF decay heat at the time of encapsulation. For other applications (short- or long-term cooling), the community would benefit from applying consistent and accepted recommendations on calculation methods, for both decay heat and uncertainties. This would improve the understanding of the results and make comparisons easier.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurements of multiple heat flux components at the divertor target by using surface eroding thermocouples (invited)

The Surface Eroding Thermocouple (SETC) is a robust diagnostic utilized in DIII-D to provide fast, edge-localized modes (ELMs) resolved heat flux measurements, in particular in geometric regions that are too shadowed for traditional infrared thermography. In order to further investigate the power dissipation in the divertor region, a combination of flush-mounted and recessed SETCs was developed to assess the effect on surface heating from non-charged particles at the divertor target. Utilizing the Divertor Materials Evaluation System sample exposure platform, the first demonstration of the feasibility of using this new method to distinguish between the heat flux from charged particles and that from neutrals and radiative heating was achieved. This paper details the process of using the combination of flush SETCs and recessed SETCs to measure the multiple heat flux components at the divertor target and further discusses how to determine two important ratios, α (ratio of heat flux from charged particles deposit on recessed SETC to that deposit on flush SETC) and β (ratio of heat flux from non-charged particles deposit on recessed SETC to that deposit on flush SETC), in the estimation of the heat flux from non-charged particle sources. Using a time dependent ratio α, it was found that ~50% of the total incident heat flux is attributable to the non-charged particles in the fully detached open divertor in DIII-D. Finally, the new application of similar SETC diagnostics in the Small Angle Slot divertor with a V-like configuration and partial tungsten coated surface (SAS-VW) is also introduced.

47 OTHER INSTRUMENTATION↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Confinement in electron heated plasmas in Wendelstein 7-X and ASDEX Upgrade; the necessity to control turbulent transport

In electron (cyclotron) heated plasmas, in both ASDEX Upgrade (L-mode) and Wendelstein 7-X, clamping of the ion temperature occurs at $T_\mathrm{i}$ ~ 1.5 keV independent of magnetic configuration. The ions in such plasmas are heated through the energy exchange power as ${n}_{\mathrm{e}}^{2}({T}_{\mathrm{e}}-{T}_{\mathrm{i}})/{T}_{\mathrm{e}}^{3/2}$, which offers a broad ion heating profile, similar to that offered by alpha heating in future thermonuclear fusion reactors. However, the predominant electron heating may put an additional constraint on the ion heat transport, as the ratio $T_\mathrm{e}T_\mathrm{i}$ > 1 can exacerbates ITG/TEM core turbulence. Therefore, in practical terms the strongly 'stiff' core transport translates into Ti-clamping in electron heated plasmas. Due to this clamping, electron heated L-mode scenarios, with standard gas fueling, in either tokamaks or stellarators may struggle to reach high normalized ion temperature gradients required in a compact fusion reactor. The comparison shows that core heat transport in neoclassically optimized stellarators is driven by the same mechanisms as in tokamaks. The absence of a strong H-mode temperature edge pedestal in stellarators, sofar (which, like in tokamaks, could lift the clamped temperature-gradients in the core), puts a strong requirement on reliable and sustainable core turbulence suppression techniques in stellarators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

3D ion gyro-orbit heat load predictions for NSTX-U

Abstract High power tokamaks operate with divertor heat loads capable of destroying the plasma facing components (PFCs). High fidelity heat load predictions are necessary to ascertain the PFC state for design and during operation. Typical heat flux calculations are 2D, time invariant, and assume that power flows directly along the magnetic field lines (the optical approximation). These assumptions neglect the complex 3D geometries employed to protect the PFCs, the time varying nature of the plasma and PFC thermal state, and the helical trajectories of ions with finite Larmor radii (the gyro-orbit approximation). An integrated software framework, the heat flux engineering analysis toolkit (HEAT), was developed to generate time varying optical heat loads applied to real engineering computer aided design (CAD) (Looby et al 2022 Fusion Sci. Technol. 78 10–27). Recently, an ion-gyro orbit module has been added to HEAT. This module calculates the helical trajectories of ions as they gyrate about the magnetic field lines using kinetic theory macro-particles to accelerate the calculation. First, the new gyro-orbit module will be presented. Next, a comparison to existing research is performed. Finally, an analysis of the gyro-orbit heat loads for NSTX-U is presented for diverted discharges using the engineering CAD models utilized for PFC fabrication. Including these gyro-orbit effects can enhance the PFC performance by ‘smearing’ out the magnetic shadows associated with the castellated fish-scaled geometry. Simultaneously, the helical trajectories can degrade performance when they load narrow regions on edges and corners with high heat fluxes. Analysis of the trade-offs between these competing effects is included, and regions for further investigation are identified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct Measurement of Diffusion Coefficients: Evidence for Diffusive Stochastic Heating in Collisionless Plasmas

Open questions in collisionless plasma dissipation can be addressed using space-based observations in different astrophysical environments, with implications for both astrophysical and laboratory plasma systems. We study a low-𝛽, highly imbalanced, sub-Alfvénic stream observed by Parker Solar Probe (PSP) to identify and distinguish between signatures of stochastic heating (SH) and resonant heating (RH) by parallel ion cyclotron waves (∥-ICWs). Prior work studying this stream [Trevor A. Bowen et al., Stochastic heating in the sub-Alfvénic solar wind, Phys. Rev. Lett. 135, 255201 (2025)] showed that the SH rate, accounting for intermittency, matched the amplitude of the local energy transfer (LET) rate, while the RH rate did not. This comparison relied on a number of assumptions regarding the nature of the diffusive process and the calculation of the LET rate. We introduce a novel technique of inverting the proton guiding center equation to empirically measure velocity-space diffusion coefficients using three-dimensional proton velocity distribution functions, from the ion electrostatic analyzer (the Solar Probe Analyzer for Ions) on PSP. Measured diffusion coefficients are used to determine phase-space heating rates, leading to a calculation of a fully kinetic heating rate independent of assumptions made in prior work. We show that scale-dependent analytic expressions for SH via noncoherent fluctuations match the empirical measurements from PSP data, provided that we account for intermittency in the heating calculation. In contrast, the derived heating rates for SH that accounts for the effects of the helicity barrier and heating rates for RH via ∥-ICWs do not peak in the same region of velocity space as the empirical measurements, nor do they reach the required magnitude. Our approach provides novel methodology to uniquely identify and constrain heating processes in collisionless plasmas and shows evidence of a Fokker-Planck-like diffusive process in the near-Sun solar wind.

Plasma kinetic theory↗

Near-Field Radiative Heat Transfer Between Two α-MoO3 Biaxial Crystals

The near-field radiative heat transfer (NFRHT) between two semi-infinite α-MoO3 biaxial crystals is investigated numerically based on the fluctuation–dissipation theorem combined with the modified 4 × 4 transfer matrix method in this paper. In the calculations, the near-field radiative heat flux (NFRHF) along each of the crystalline directions of α-MoO3 is obtained by controlling the orientation of the biaxial crystals. The results show that much larger heat flux than that between two semi-infinite hexagonal boron nitride can be achieved in the near-field regime, and the maximum heat flux is along the [001] crystalline direction. The mechanisms for the large radiative heat flux are explained as due to existence of hyperbolic phonon polaritons (HPPs) inside α-MoO3 and excitation of hyperbolic surface phonon polaritons (HSPhPs) at the vacuum/α-MoO3 interfaces. The effect of relative rotation between the emitter and the receiver on the heat flux is also investigated. It is found that the heat flux varies significantly with the relative rotation angle. The modulation contrast can be as large as two when the heat flux is along the [010] direction. We attribute the large modulation contrast mainly to the misalignment of HSPhPs and HPPs between the emitter and the receiver. Hence, the results obtained in this work may provide a promising way for manipulating near-field radiative heat transfer between anisotropic materials.

Engineering↗

High Power Density Thermal Energy Storage With Phase Change Material in Enhanced Compact Heat Exchangers

Abstract Performance of a novel ultracompact thermal energy storage (TES) heat exchanger, designed as a microchannel finned-tube exchanger is presented. With water as the heating–cooling fluid in the microchannels, a salt hydrate phase change material (PCM), lithium nitrate trihydrate (LiNO3 · 3H2O), was encased on the fin side. To establish the hypothesis that small-length-scale encasement (<3 mm) of PCM substantially enhances heat transfer to yield very high power-density energy storage, heat exchanger designs with 10 and 24 fins/inch were considered. They were subjected to thermal cycling, or repeated heating (melting) and cooling (freezing), with inlet fluid flow mimicking diurnal variation between 42 °C and 25 °C (representing typical arid-region conditions) over an accelerated time period. By employing salt self-seeding to obviate subcooling during cooling or recrystallization, the TES was found to exhibit stable long-term (100 heating–cooling cycles) operation with very high PCM-side heat transfer coefficients (∼100–500 W/m2 K) and storage power density (∼160–175 kW/m3). In fact, with optimization of heating–cooling fluid flowrate for given charging–discharging time period and exchanger size, power density >300 kW/m3 can be achieved. The results clearly establish that highly compact heat exchangers used as TES units can provide very high-performance alternatives to conventional ones.

Engineering↗

Impact of Heat Input and Step Over Distance on Part Geometry for Multi-Bead WAAM Components

Abstract This study investigates the impact of heat input and overlap ratio or stepover distance on part geometry in wire arc additive manufacturing (WAAM). In this work, an experimental approach was taken to quantify the variation in height and aspect ratio of walls at different combinations of overlap and heat input. Multi-bead walls were deposited with the overlap ratio varying from ½, ⅔, and 1 at a low, medium, and high-power set point on the welding power supply. A relationship between heat input, overlap ratio, and the resultant part geometry is established. Trials with an overlap ratio of one and low to medium heat input exhibited greater lack of fusion defects than the high heat input trials. At higher heat input levels, the as-deposited geometry was found to have less variation in height and an increase in aspect ratio compared to lower heat input trials. The aspect ratio of deposited walls ranged from approximately 1, for the low-power trial with an overlap ratio of ½, to approximately 7, for the high-power trial with an overlap ratio of 1. Additionally, the low and medium power trials with an overlap ratio of ⅔ exhibited the least height variation in the top surface for those heat input levels with an average range of 2.9 mm and 1.8 mm respectively. For the high heat input trials, an overlap ratio of 1 was observed to have the least variation in height with a standard deviation of 0.42 mm and an average range of 1.7 mm; however, lack of fusion defects were present in the top surface and the part cross section.

Hussein, Zaky↗

Pinch Heat Integration Tool (PIT) v0.9

The pinch heat integration tool (PIT) is a multi-module tool designed for identifying and analyzing thermal energy integration at facilities. It generates pinch and grand composite curves to identify optimal streams for heat exchange and industrial heat pumps. Users input heating and cooling stream data via an Excel sheet. The tool comprises four modules: 1. 'Main Pinch' for creating a pinch diagram using user-provided data. 2. 'GCC' for generating a grand composite curve to identify utility optimization opportunities. 3. 'Heat Exchanger' for analyzing stream combinations for heat exchange. 4. 'Heat Pump' for evaluating streams as sources and sinks for heat pumps and calculating the heat pump's coefficient of performance based on the selected refrigerant.

Karki, Unique [Lawrence Berkeley National Laborato↗

Atmospheric Variability Drives Anomalies in the Bering Sea Air–Sea Heat Exchange

Abstract High latitudes, including the Bering Sea, are experiencing unprecedented rates of change. Long-term Bering Sea warming trends have been identified, and marine heatwaves (MHWs), event-scale elevated sea surface temperature (SST) extremes, have also increased in frequency and longevity in recent years. Recent work has shown that variability in air–sea coupling plays a dominant role in driving Bering Sea upper-ocean thermal variability and that surface forcing has driven an increase in the occurrence of positive ocean temperature anomalies since 2010. In this work, we characterize the drivers of the anomalous surface air–sea heat fluxes in the Bering Sea over the period 2010–22 using ERA5 fields. We show that the surface turbulent heat flux dominates the net surface heat flux variability from September to April and is primarily a result of near-surface air temperature and specific humidity anomalies. The airmass anomalies that account for the majority of the turbulent heat flux variability are a function of wind direction, with southerly (northerly) wind advecting anomalously warm (cool), moist (dry) air over the Bering Sea, resulting in positive (negative) surface turbulent flux anomalies. During the remaining months of the year, anomalies in the surface radiative fluxes account for the majority of the net surface heat flux variability and are a result of anomalous cloud coverage, anomalous lower-tropospheric virtual temperature, and sea ice coverage variability. Our results indicate that atmospheric variability drives much of the Bering Sea upper-ocean temperature variability through the mediation of the surface heat fluxes during the analysis period. Significance Statement A long-term ocean warming trend and a recent increase in marine heatwaves in the Bering Sea have been identified. Previous work showed that anomalies in the exchange of heat between the ocean and the atmosphere were the primary driver of Bering Sea temperature variability, but the processes responsible for the heat exchange anomalies were unknown. In this work, we show that the atmosphere is the primary driver of anomalies in the Bering Sea air–sea heat exchange and therefore plays an important role in altering the thermal state of the Bering Sea. Our results highlight the importance of understanding more about how the ocean and the atmosphere interact at high latitudes and how this relationship will be affected by future climate change.

Hayden, Emily E. [a College of Earth, Ocean, and A↗

Effects of Heat Pipe Failures in Microreactors

Microreactors provide new opportunities for nuclear reactor applications given their long-lived fuel source, compact size, portability, reliability as it relates to safety and their self-regulating nature. To take advantage of these opportunities there are technological challenges that need to be overcome. One advancing technology often used in conjunction with microreactor designs are heat pipes, which are used for heat removal from the reactor core to the power conversion system. Heat pipes are a substitute for the traditional system in which the same fluid used as coolant in the reactor is then used as the working fluid in the power conversion system. This document describes how heat pipes operate, what happens when a heat pipe fails, and what codes can be used to simulate the results. Our analyses show that a single/double heat pipe failure results in a temperature increase of 15-50°C respectively in surrounding heat pipes. Heat pipe microreactors could be easily designed such that this increase is within the maximum parameters allowable for safety and does not result in cascading heat pipe failure. Thus, such failures do not lead to severe degradation of the reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Field Measurement of Central CO2 Heat Pump Water Heater for Multifamily Retrofit

Domestic hot water heating of multifamily buildings accounts for a substantial portion of the energy load of existing buildings. This load is made up of both the energy required to produce hot water and the energy needed to maintain the temperature of the heated water within a building’s distribution piping so that heat can be promptly delivered to building occupants as needed. Properly designed heat pump water heater (HPWH) systems have the ability to improve efficiency in both water heating and temperature control operations. Further, CO2 heat pump technology reflects a shift away from traditional refrigerants and toward refrigerants with low global warming potential (GWP). In this paper’s case study, a design consisting of multiple CO2 heat pump water heaters (commonly used in single-family homes) with a novel “swing tank” was proposed to meet the demand for domestic hot water heating and recirculation loop temperature maintenance. The proposed design was applied to the retrofit of a 60-unit, low-rise, multi-family building located in the Pacific Northwest of the United States. The purpose of this paper is to verify the performance of the system including the proposed “swing tank” in a centralized SHW system using CO2 HPWH. It also provides practical information and lessons learned from the retrofit project. Long-term monitoring data showed that the system had a coefficient of performance (COP) of three or greater and provided an average of 20 gallons of hot water per day per apartment. The results of this work indicate that residential-scale CO2 HPWH equipment and a “swing tank” design can efficiently provide domestic hot water heating and temperature maintenance for mid-sized multifamily buildings.

Banks, Adria↗