Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Studying MeV Scale Neutron Interactions in DUNE ND-LAr 2x2 Demonstrator

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment designed to make high-precision measurements of neutrino oscillation parameters and probe for new physics using a neutrino beam produced at Fermilab and measured at a near detector complex and a far detector located 1,300 km away at the Sanford Underground Research Facility. Precise neutrino energy reconstruction is essential for these measurements, with neutron production in neutrino–argon interactions representing a significant source of systematic uncertainty, as neutrons can carry away significant energy, making their detection and characterization crucial. DUNE’s near detector complex includes ND-LAr, a Liquid Argon Time Projection Chamber (LArTPC) detector designed to mirror the far detector technology and constrain neutrino–argon interaction systematics. The DUNE 2x2 Demonstrator, a pixelated LArTPC based on the ArgonCube design, serves as a prototype for ND-LAr. During 2x2 operations from October to November 2026, an Americium–Beryllium (AmBe) neutron source was deployed near the detector cryostat to obtain a high-statistics sample of neutron interactions. This poster presents progress in studying MeV-scale neutron interactions in this dataset by identifying de-excitation gammas from neutron capture on argon, providing a method for neutron identification and charge readout system calibration in future DUNE detectors.

Mao, Edgar [Syracuse U.] (ORCID:0009000600893306)↗

MC-Lite: Development of a new lightweight multiplicity counter

This report details the development of a neutron multiplicity counter based on lithium doped plastic scintillators. This system has the capability to measure and discriminate fast neutrons, thermal neutrons, and gamma-rays allowing for multi-particle correlations in one device. The system was built and tested at Lawrence Livermore National Laboratory with Cf-252 in both bare configurations and surrounded by polyethylene and compared against the MC-15 multiplicity counter. Additionally, the detector was also placed outside of a subcritical assembly and demonstrated the ability to use correlated gamma-rays as a probe on the multiplication of the item.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlating gravitational wave and gamma-ray signals from primordial black holes

Asteroid-mass primordial black holes (PBHs) can explain the observed dark matter abundance while being consistent with the current indirect detection constraints. These PBHs can produce gamma-ray signals from Hawking radiation that are within the sensitivity of future measurements by the AMEGO and e-ASTROGAM experiments. PBHs which give rise to such observable gamma-ray signals have a cosmic origin from large primordial curvature fluctuations. There must then be a companion, stochastic gravitational wave (GW) background produced by the same curvature fluctuations. We demonstrate that the resulting GW signals will be well within the sensitivity of future detectors such as LISA, DECIGO, BBO, and the Einstein Telescope. The multimessenger signal from the observed gamma-rays and GWs will allow a precise measurement of the primordial curvature perturbation that produces the PBH. Indeed, so we argue that the resulting correlation between the two types of observations can provide a smoking-gun signal of PBHs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New Experiments for Detecting Emissions from Fission

Ensuring that nuclear science and technology is used solely for peaceful purposes is one of the most pressing challenges facing our society. The Consortium for Monitoring, Technology, and Verification (MTV) mission is to help meet this challenge by providing advanced technology and trained talent for careers in nuclear security and nonproliferation. The study of nuclear fission is one area of interest in the MTV. We are performing new experiments for the characterization of neutron and gamma ray emissions from fission fragments. These emissions are signatures for the detection and characterization of nuclear materials. To perform these experiments, we have developed Fission Sphere (FS-3), an array of forty organic stilbene detectors operated in time-coincidence. The FS-3 is used to measure the prompt emissions of neutrons and gamma rays from Cf-252 spontaneous fission. These new data will be used to validate physics-based prediction codes, including CGMF and FREYA, and will be useful in future ENDF and ENSDF evaluations. This paper will present results from the first experiments using FS-3 and a Cf-252 spontaneous fission source. It will compare the experimental results with predictions from theory and Monte Carlo simulation. Specifically, we will describe the correlations among energy, multiplicity, and angles of emitted particles. We will also discuss the application of these correlations in multiplicity counting techniques, which are widely used in nuclear safeguards.

Pozzi, S. A.↗

Comparison Between Predictions & Observations of Induced Radioactive Background in Interplanetary Missions

Radioactivity induced in detector materials and their immediate surroundings is the major source of discrete-line, gamma-ray background and an important source of continuum background in the performance of remote-sensing, gamma-ray spectroscopy of planetary bodies. In interplanetary space the dominant sources of particles are cosmic rays and their secondaries arising from interactions with the spacecraft and the surface of the target body. In addition, certain future gamma-ray astronomy missions, such as INTEGRAL, are to be located so as to perform their observations in interplanetary space rather than in the traditional low earth orbits. Such location removes contributions from the earth's atmosphere and inner radiation belt at the expense of increased exposure to cosmic rays and solar particle events. Accurate prediction of the activation of key materials by cosmic rays is of the utmost importance for detector design and data interpretation.

Dyer, Clivea↗

Measurement of 0.511-MeV gamma rays with a balloon-borne Ge/Li/ spectrometer

A collimated high-resolution gamma ray spectrometer was flown on a balloon over Palestine, Texas, on June 10, 1974, to obtain measurements of the terrestrial and extraterrestrial 0.511-MeV gamma rays. The spectrometer consists of four 40-cu-cm Ge(Li) crystals operating in the energy range 0.06-10 MeV; this cluster of detectors is surrounded by a CsI(Na) anticoincidence shield. This system is used primarily to allow measurements of the two escape peaks associated with high-energy gamma ray lines. It also allows a measurement of the background component of the 0.511-MeV flux produced by beta(+) decays in materials inside the CsI(Na) shield. It is shown that the measurements of the atmospheric fluxes are consistent with earlier results after allowance is made for an additional component of the background due to beta(+) decays produced by neutron- and proton-initiated interactions with materials in and near the detector. Results of the extraterrestrial flux require an extensive detailed analysis of the time-varying background because of activation buildup and balloon spatial drifts.

Ling, J. C.↗

SONGS - A high resolution imaging gamma-ray spectrometer for the Space Station

The overall design and the instrumental features of the Space-Station Observer for Nuclear Gamma-ray Spectroscopy (SONGS) instrument are described. SONGS comprises an array of 19 two-segment n-type Ge detectors, which have the capability of determining the interaction site in either the upper or the lower segment or in both segments. The detectors provide high energy resolution of 1 keV at 100 keV and of 2 keV at 1 MeV. The close-packed Ge sensor array provides a natural sensitivity for the measurement of gamma ray polarization in the 100 keV to 1 MeV energy range, making it possible to obtain information on the structure of the magnetosphere of neutron stars and of the accretion disk of black holes.

Nakano, G. H.↗

Tensioned metastable fluid detector sensing technology for multifarious-multiscale applications in the nuclear fuel cycle

The nuclear fuel cycle presents formidable 10 30+ multiscale challenges for high-efficiency spectroscopic sensing of alpha-neutron-fission radiation signatures amidst extreme gamma-beta radiation backgrounds at various stages of the cycle; it involves diverse arenas ranging from continuous/pulsed power production, security/safeguards, spent fuel, environmental remediation, and personnel health-dosimetry. This paper discusses the novel tensioned metastable fluid detector (TMFD) sensor technology. It discusses the results of studies demonstrating extreme (10 4 Sv/h) gamma-beta field blind high intrinsic efficiencies (80–100%) for neutron-alpha-fission radiation spectrometric detection. Example studies discussed in this paper include Neutron detection with spectroscopy; H*10 neutron radiation dosimetry upwards from ultra-low10 −2 µSv/h levels; Air and/or liquid-borne trace (10 –3 Bq/mL) quantity, 1 keV energy resolved alpha/fission spectroscopy for Rn/Po/U/Pu/Am environmental isotope assays at 106:1 (β:α) ratios; Directional-position enabled extended standoff tracking of neutron emitting (shielded/unshielded) special nuclear materials while stationary or moving at highway speeds; and, U.S. Department of Energy nuclear complex wide nuclear waste reprocessing, criticality safety, health physics, and environmental applications.

Alpha-fission-neutron spectrometry↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emitted radiation characteristics of plutonium dioxide radioisotope thermoelectric generators

The nuclear and emitted radiation characteristics of the radioisotope elements and impurities in commercial grade plutonium dioxide are presented in detail. The development of the methods of analysis are presented. Radioisotope thermoelectric generators (RTG) of 1575, 3468 and 5679 thermal watts are characterized with respect to neutron and gamma photon source strength as well as spatial and number flux distribution. The results are presented as a function of detector position and light element contamination concentration for fuel age ranging from 'fresh' to 18 years. The data may be used to obtain results for given O-18 and Pu-236 concentrations. The neutron and gamma photon flux and dose calculations compare favorably with reported experimental values for SNAP-27.

Gingo, P. J.↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Internal Energy Calibration by OnTheFly for AGR-5/6/7

The software program, OnTheFly, was developed at Idaho National Laboratory (INL) to keep high-purity germanium (HPGe) detectors energy calibrated during very long experiments. Over time, spectra produced from a HPGe detector will slowly stretch or contract, causing the energy calibration to change. If the energy calibration changes too much, it will cause energy lines to be misidentified. The higher the energy line the more affected they are by this change. OnTheFly tracks and adjusts the slowly changing energy calibrations so the energy lines will not be misidentified. OnTheFly was used with the Fission Product Monitoring System (FPMS) during the AGR-5/6/7 irradiation experiment performed at INL’s Advanced Test Reactor (ATR). Five HPGe detectors were used to monitor the five capsules in AGR-5/6/7. There were also two extra HPGe detectors that were maintained as spares. Before each ATR cycle of the experiment, the HPGe detectors were energy calibrated with a thorium radioactive source. During each ATR cycle, each detector would acquire data for 8 hours and then reset and acquire data for another 8 hours. After each 8-hour run, the spectra would be saved and analyzed autonomously. The results were then read by OnTheFly and used to produce a new energy calibration for each detector. The new energy calibrations were compared to the current energy calibrations and, if certain criteria were met, the new energy calibration would replace the current energy calibration. The new energy calibration would be used for future spectra. OnTheFly was run at least every couple of days but could be run as much as after each 8-hour run. OnTheFly kept the spectra energy calibrated during the ATR cycles over the 2 years and 5 months that the AGR-5/6/7 experiment ran.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Precision measurements on oxygen formation in stellar helium burning with gamma-ray beams and a Time Projection Chamber

The carbon/oxygen (C/O) ratio at the end of stellar helium burning is the single most important nuclear input to stellar evolution theory. However, it is not known with sufficient accuracy, due to large uncertainties in the cross-section for the fusion of helium with 12 C to form 16 O, denoted as 12 C( α , γ ) 16 O. Here we present results based on a method that is significantly different from the experimental efforts of the past four decades. With data measured inside one detector and with vanishingly small background, angular distributions of the 12 C( α , γ ) 16 O reaction were obtained by measuring the inverse 16 O( γ , α ) 12 C reaction with gamma-beams and a Time Projection Chamber (TPC) detector. We agree with current world data for the total reaction cross-section and further evidence the strength of our method with accurate angular distributions measured over the 1 - resonance at E cm ~2.4 MeV. Our technique promises to yield results that will surpass the quality of the currently available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Observation and Spectral Measurements of the Crab Nebula with Milagro

The Crab Nebula was detected with the Milagro experiment at a statistical significance of 17 standard deviations over the lifetime of the experiment. The experiment was sensitive to approximately 100 GeV - 100 TeV gamma ray air showers by observing the particle footprint reaching the ground. The fraction of detectors recording signals from photons at the ground is a suitable proxy for the energy of the primary particle and has been used to measure the photon energy spectrum of the Crab Nebula between ~1 and ~100 TeV. The TeV emission is believed to be caused by inverse-Compton up-scattering scattering of ambient photons by an energetic electron population. The location of a Te V steepening or cutoff in the energy spectrum reveals important details about the underlying electron population. We describe the experiment and the technique for distinguishing gamma-ray events from the much more-abundant hadronic events. We describe the calculation of the significance of the excess from the Crab and how the energy spectrum is fit.

Abdo, A. A.↗

Gamma-Ray Pulse Tube Cooler Development and Testing

For a variety of space-science applications, such as gamma-ray spectroscopy, the introduction of cryogenic cooling via a cryocooler can greatly increase the potential science return by allowing the use of more sensitive and lower noise detectors.

gamma-ray cryogenic cryocooler pulse tube↗

Surface-Defect-Passivation-Enabled Near-Unity Charge Collection Efficiency in Bromide-Based Perovskite Gamma-Ray Spectrum Devices

Hybrid lead halide perovskites have superior charge transport properties to all-inorganic perovskites, but high-resolution spectroscopic radiation detectors have not been realized. Here we show that surface deep traps severely limit charge collection in formamidinium lead bromide (FAPbBr3) single-crystal devices, despite having a good bulk transport property. Three types of defect on the crystal surface, namely, FA vacancies, uncoordinated lead and Pb-Pb dimers caused by bromide loss, are found to form deep traps, resulting in non-radiative charge recombinations at the metal/perovskite interface. By tailoring the passivation functional groups, we find that ammonium bromide can passivate all these three deep traps on FAPbBr3 surfaces, improving the charge collection efficiency to near unity. The comparable bulk and surface recombination lifetimes indicate that all the surface defects are effectively passivated. Surface passivation also reduces the dark current by 10 times and decreases the dark counts by ~60 times. The energy resolution of the 137Cs spectra acquired using the FAPbBr3 detectors is improved from 5.7% to 1.7% when all the surface defects are passivated without changing the bulk properties, which is the best among solution-grown semiconductor detectors. Surface passivation is stable for more than six months, and FAPbBr3 spectroscopic detectors can operate at unprecedented high temperatures of more than 130 degrees C.

gamma ray↗

Source Search Concepts [Slides]

Summary: Detection of gamma rays is affected by shielding type and thickness, distance, source intensity, and detector. The ISL will not work well for extended sources, or complex shielding situations. The ‘3D-T’ search process involves finding a hotspot in one direction, then, working in 90-degree angles (“tees”), finding the hotspots in the other two directions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗