Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Pan-Arctic daily streamflow at 0.5-degree resolution

Data was derived using daily runoff from models participating in the Coupled Model Intercomparison Project, version 6 (CMIP6) that have been routed through the Model for Scale Adaptive River Transport (MOSART) routing model to represent streamflow at individual streamflow gage locations. Data from 750 streamflow gage locations are represented, which are indexed by gage id according to the metadata.csv file. Streamflow gage location sites were based on gage records downloaded from the United States Geological Survey (USGS), National Water Data (HYDAT) Archive from Canada, and the State Hydrological Institute of Russia. Data are available from 11 Earth System Models (ESMs) in total at a daily timestep with a duration of 1920-2099 (1850-2014 for E3SM only). The spatial domain of the modeled data is 0.5 degree resolution. Earth System Models and Units of mean daily streamflow are presented in cubic meters per second (cms). Data files consist of 11 Earth System Model mean daily streamflow output per gage location in .csv format, 1 metadata file in .csv format and 1 Readme file in .docx format (13 files in total). These data were used to benchmark CMIP6 modeled representations of streamflow against gage records.

54 ENVIRONMENTAL SCIENCES↗

An infrared jet in Centaurus A (NGC 5128): Evidence for interaction between the active nucleus and the interstellar medium

In the present study, higher resolution near infrared images of the visually-obscured central region of Centaurus A were obtained in order to investigate the effects of the active nucleus on the surrounding galaxy. Researchers present J(1.25 microns), H(1.65 microns), and K(2.2 microns) images of the central 40 seconds of the galaxy, taken with the Univ. of Texas InSb array camera on the Anglo Australian 3.9 meter telescope. These images reveal a jet extending approx. 10 arcseconds to the northeast of the nucleus at the same position angle as the x ray and radio jets. The infrared jet is most prominent at the shortest wavelength (1.25 microns), where its brightness surpasses that of the nucleus. The blue appearance of the infrared jet is remarkable considering the heavy obscuration that is evident at visual wavelengths. The amount of reddening in the vicinity of the jet is determined from the measured colors of the stellar core of the galaxy, and this value is used to generate an extinction-corrected energy distribution. In contrast to previously studied optical and infrared jets in active nuclei, the short-wavelength prominence of the Cen A jet indicates that it cannot be attributed to synchrotron emission from a beam of relativistic electrons. The remaining viable mechanisms involve an interaction between the interstellar medium and the active nucleus: the infrared radiation from the jet may be due to emission from interstellar gas that has been entrained and heated by the flow of relativistic particles from the nucleus; alternatively, luminous blue stars may have been created by compression of interstellar material by the relativistic plasma. To investigate these proposed mechanisms, near-infrared spectroscopic studies of Cen A are in progress to look for collisionally excited molecular hydrogen emission lines and recombination lines from ionized gas.

Joy, Marshall↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Stress Analysis and Permeability Testing of Cryogenic Composite Feed Line

For the next generation Single-Stage-To-Orbit (SSTO) Reusable Launch Vehicle (RLV), the use of advanced composite materials is highly desirable and critical to the success of the mission. NASA Marshall Space Flight Center (MSFC) has been working with the aerospace industry for many years to develop and demonstrate the cryogenic composite propellant tanks and feed lines technologies. A 50.8-mm diameter composite feed line for the Clipper Graham (DCY.A) was developed and tested. The purpose of the program is to demonstrate the LH2 permeability, composite to composite and metal joints, as well as composite flange interface of the composite feed line. Stress analysis and permeability testing have been performed on this article. Recently, a larger composite feed line design is being investigated and developed at MSFC for potential use in future RLV. The diameter of the feed line is 203 mm and the overall length is approximately 2.2 meters. This one piece unlined feed line consists of three straight tubular sections joined by two 90 degree elbows. The material chosen is IM7/977-3 prepreg fabric. The lay-up pattern is [0/90, plus or minus 45]s and is built up to 18 plies to the flanges at both ends. A preliminary stress analysis has been conducted to identify potential critical stresses and to develop the finite element analysis (FEA) capability of composite feed lines. As expected, the critical stresses occurred at the rims of some flange holes and the onset of the tapered tubular sections. Further analysis is required to determine the loads, flange deflection, vibration, and combined maximum loads. Two permeability-testing apparatuses were also designed for both flat panel specimens and curved feed line sections after impact damage. A larger permeant gas exposed area is required to accurately determine the effect of impact damage on the permeability of the feed line materials. The flat panel tester was fabricated and assembled. Three test coupons were made of graphite/epoxy plain weave prepreg and unidirectional prepreg. The flow rate was calculated by measuring the change of manometer fluid height per unit time. The permeability of the coupons is then calculated according to Darcy's Law. The pressure increase due to the head rise in the manometer was not considered for the initial estimation. The result of the unidirectional composite coupon agreed with that obtained from the DC-XA feed line testing of a similar material. Further improvement on the design may be required to improve the accuracy and efficiency of permeability testing.

Chu, Tsuchin Philip↗

Great Salt Lake Health and Air Quality: Monitoring Lakebed Exposure and its Impact on Air Quality and Environmental Hazards in the Great Salt Lake Watershed

Water flow into the Great Salt Lake has declined rapidly over the last forty years due to human withdrawals and climate change. As a result of declining lake levels, over 50% of the lakebed is now exposed. Dust storms may grow in frequency and intensity across Northern Utah as lakebed dust becomes airborne under specific meteorological conditions. In our research project, we utilized satellite imagery from Terra and Aqua, Sentinel-5P, CALIPSO, Landsat 5 TM, Landsat 7 ETM+, Landsat 8 OLI-2, Suomi NPP, ground sensor environmental data, and demographic data to understand the relationship between lake desiccation and dust, and the impact of pollution upon the communities surrounding the Great Salt Lake. By plotting changes in Lake Surface Area against Aerosol Optical Depth (AOD) over our study period (2010-2022), we found an inverse relationship (R2=0.3423) between lake surface area and dust levels within our study area. We conducted a Vertical Feature Mask (VFM) and Extinction Coefficient Plot, from which we identified that during dust events, the aerosol type is mainly polluted dust and the aerosol height is 200 meters from the surface. Lastly, we created bivariate choropleth maps, which demonstrate which census tracts within our study area are most vulnerable to AOD (a proxy for PM2.5 from dust), NO2 and HCHO (precursors to ozone). In summary, our findings revealed that declining lake levels are associated with an increase in intensity of dust events, and these dust events will particularly impact residents of Tooele County and the west side of Salt Lake City. Project resources support partner needs by informing targeted air monitoring efforts, lakebed management practices, and advocacy efforts for GSL stewardship.

Terminal Saline Lake↗

Research Traffic Management Advisor (rTMA) Up-level Final Report

The FAA Time Based Flow Management (TBFM) Program provides for operational use and continued development of the Traffic Management Advisor (TMA) technology that NASA demonstrated in 1996. Although NASA's Center-TRACON Automation System (CTAS) software baseline includes advanced versions of TMA, some research activities are better served by a version of TMA that more closely matches the FAA's TBFM software. Beginning in 2009, NASA created Research TMA (rTMA) to enable researchers to work with FAA TBFM software in a research environment. The original rTMA was derived from TBFM v3.10 and later up-leveled to TBFM v3.12. This report documents the most recent up-level effort in which rTMA was re-derived from TBFM v4.00.07.

traffic management↗

Low-speed aerodynamic characteristics of a highly swept, untwisted uncambered arrow wing

An investigation was conducted in the Langley 4- by 7-Meter Tunnel to provide a detailed study of wing pressure distributions and forces and moments acting on a highly swept arrow-wing model at low Mach numbers (0.25). A limited investigation of the effect of spoilers at several locations was also conducted. Analysis of the pressure data shows that for the configuration with undeflected leading edges, vortex separation occurs on the outboard wing panel for angles of attack on the order of only 3 deg, whereas conventional leading-edge separation occurs at a nondimensional semispan station of 0.654 for the same incidence angle. The pressure data further show that vortex separation exists at wing stations more inboard for angles of attack on the order of 7 deg and that these vortices move inboard and forward with increasing angle of attack. The force and moment data show the expected nonlinear increments in lift and pitching moment and the increased drag associated with the vortex separation. The pressure data and corresponding force and moment data confirm that deflecting the entire wing leading edge uniformly to 30 deg is effective in forestalling the onset of flow separation to angles of attack greater than 8.6 deg; however, the inboard portion of the leading edge is overdeflected. The investigation further identifies the contribution of the trailing-edge flap deflection to the leading-edge upwash fields.

Coe, P. L., Jr.↗

Laboratory Investigation of Ice Formation and Elimination in the Induction System of a Large Twin-engine Cargo Aircraft

The icing characteristics, the de-icing rate with hot air, and the effect of impact ice on fuel metering and mixture distribution have been determined in a laboratory investigation of that part of the engine induction system consisting of a three-barrel injection-type carburetor and a supercharger housing with spinner-type fuel injection from an 18-cylinder radial engine used on a large twin-engine cargo airplane. The induction system remained ice-free at carburetor-air temperatures above 36 F regardless of the moisture content of the air. Between carburetor-air temperatures of 32 F and 36 F with humidity ratios in excess of saturation, serious throttling ice formed in the carburetor because of expansion cooling of the air; at carburetor-air temperatures below 32 F with humidity ratios in excess of saturation, serious impact-ice formations occurred, Spinner-type fuel injection at the entrance to the supercharger and heating of the supercharger-inlet elbow and the guide vanes by the warn oil in the rear engine housing are design features that proved effective in eliminating fuel-evaporation icing and minimized the formation of throttling ice below the carburetor. Air-flow recovery time with fixed throttle was rapidly reduced as the inlet -air wet -bulb temperature was increased to 55 F; further temperature increase produced negligible improvement in recovery time. Larger ice formations and lower icing temperatures increased the time required to restore proper air flow at a given wet-bulb temperature. Impact-ice formations on the entrance screen and the top of the carburetor reduced the over-all fuel-air ratio and increased the spread between the over-all ratio and the fuel-air ratio of the individual cylinders. The normal spread of fuel-air ratio was increased from 0.020 to 0.028 when the left quarter of the entrance screen was blocked in a manner simulating the blocking resulting from ice formations released from upstream duct walls during hot-air de-icing.

ICE PREVENTION - AIR HEATING↗

Sailplane Glide Performance and Control Using Fixed and Articulating Winglets

An experimental study was conducted to investigate the effects of controllable articulating winglets on glide performance and yawing moments of high performance sailplanes. Testing was conducted in the Texas A&M University 7 x 10 foot Low Speed Wind Tunnel using a full-scale model of the outboard 5.6 feet of a 15 meter class high performance sailplane wing. Different wing tip configurations could be easily mounted to the wing model. A winglet was designed in which the cant and toe angles as well as a rudder on the winglet could be adjusted to a range of positions. Cant angles used in the investigation consisted of 5, 25, and 40 degrees measured from the vertical axis. Toe-out angles ranged from 0 to 22.5 degrees. A rudder on the winglet was used to study the effects of changing the camber of the winglet airfoil on wing performance and wing yawing moments. Rudder deflections consisted of-10, 0, and 10 degrees. Test results for a fixed geometry winglet and a standard wing tip are presented to show the general behavior of winglets on sailplane wings, and the effects of boundary-layer turbulators on the winglets are also presented. By tripping the laminar boundary-layer to turbulent before laminar separation occurs, the wing performance was increased at low Reynolds numbers. The effects on the lift and drag, yawing moment, pitching moment, and wing root bending moment of the model are presented. Oil flows were used on the wing model with the fixed geometry winglet and the standard wing tip to visualize flow directions and areas of boundary layer transition. A cant angle of 25 degrees and a toe-out angle of 2.5 degrees provided an optimal increase in wing performance for the cant and toe angles tested. Maximum performance was obtained when the winglet rudder remained in the neutral position of zero degrees. By varying the cant, toe, and rudder angles from their optimized positions, wing performance decreases. Although the winglet rudder proved to be more effective in increasing the yawing moment compared to varying the cant and toe angles, the amount of increased yawing moment was insignificant when compared to that produced by the vertical tail. A rudder on the winglet was determined to be ineffective for providing additional yaw control.

Colling, James David↗

Particle Ejection and Levitation Technology (PELT)

Each of the six Apollo landers touched down at unique sites on the lunar surface. Aside from the Apollo 12 landing site located 180 meters from the Surveyor III lander, plume impingement effects on ground hardware during the landings were not a problem. The planned return to the Moon requires numerous landings at the same site. Since the top few centimeters of lunar soil are loosely packed regolith, plume impingement from the lander will eject the granular material at high velocities. A picture shows what the astronauts viewed from the window of the Apollo 14 lander. There was tremendous dust excavation beneath the vehicle. With high-vacuum conditions on the Moon (10 (exp -14) to 10 (exp -12) torr), motion of all particles is completely ballistic. Estimates derived from damage to Surveyor III caused by the Apollo 12 lander show that the speed of the ejected regolith particles varies from 100 m/s to 2,000 m/s. It is imperative to understand the physics of plume impingement to safely design landing sites for future Moon missions. Aerospace scientists and engineers have examined and analyzed images from Apollo video extensively in an effort to determine the theoretical effects of rocket exhaust impingement. KSC has joined the University of Central Florida (UCF) to develop an instrument that will measure the 3-D vector of dust flow caused by plume impingement during descent of landers. The data collected from the instrument will augment the theoretical studies and analysis of the Apollo videos.

Source record↗

Cloud Microphysics in Hurricane Outflows: Observations in 'Bonnie' (1998) at 12 km Altitude

The water balance of a hurricane is controlled by boundary layer inflow, near vertical motion in the eyewall causing coalescence precipitation at above and residual ice precipitation at below freezing temperatures, and cirrus outflow at below -40 C aloft. In this paper we address the question of efficiency of water removal by this cirrus outflow which is important for the release of latent heat at high altitudes and its role in the dynamic flow at that level. During NASA's 1998 Convection and Moisture Experiment campaign we acquired microphysical outflow data in order to (1) determine the release and redistribution of latent heat near the top of hurricanes, (2) aid in TRMM algorithm development for remote sensing of precipitation, and (3) determine the optical/radiative characteristics of hurricane outflow. The data were acquired with Particle Measuring Systems two dimensional imaging spectrometers. On 23 August and again during the hurricane's landfall on 26 August, 1998, the NASA DC-8 aircraft penetrated hurricane 'Bonnie' four times each near 200 hPa pressure altitude. The eye crossing times were determined by (1) zero counts of cloud particles, (2) approximately 5 C increases in static and potential temperatures, and (3) minima in speeds and changes of direction of horizontal winds. The vertical winds showed shear between -6 m per second and +4 m per second and tangential winds approached 30 m per second in the eyewall. The particle volumes in the eyewall (determined by the pixels the particles shadowed in the direction of flight [x-direction] and normally to it by the number of diodes that they shadowed [y-direction]) ranged between 0.5 and 5.0 cubic centimeters per cubic meter. With a particle density near 0.2 g per cubic centimeter (determined from in situ melting and evaporation on a surface collector), the 1.0 g per meter corresponding mass of cloud ice ranged between 0.27 and 2.7 g per kilograms yielding horizontal fluxes between 8.1 and 81 g per square meters per second. The outflow ice was concentrated in crystals of a modal size of 190 micrometers. The particle size distributions were heavily skewed toward sizes with 98% of all cirrus particles smaller than the modal size comprising, however, only 20% of the mass. Thus the smaller than modal size particles dominantly affected the optical/radiative characteristics of the cloud, whereas the larger than modal size crystals determined the ice mass, hence dominated latent heating. Questions to be addressed relate to the origin of individual ice particles as the hurricane evolved and the likelihood of pristine and aggregate particle formation under the complicated conditions of rotation and outflow in the eyewall.

Pueschel, Rudolf F.↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Move That Goo!

On May 5, 1961, Alan B. Shepard became the first American in space (K. Mars); since then, NASA has made leaps and bounds in space exploration and continues to develop new technologies. Through their X-Hab program, NASA has teamed up with the National Space Grant Foundation to fund our student-centered project with one main goal: Move That Goo! Liquid amine absorption is a method by which CO2 is removed from an environment and is intended to be the primary method for CO2 removal for NASA’s sustained human presence on extraterrestrial bodies such as the Moon and Mars. Liquid amines can be highly viscous when absorbing CO2, thus the team needed to produce a design that could move a high viscosity fluid while staying under the power requirement of 1 kW and allowing a few square meters in a closed system. Prompted by NASA and with the support of our faculty mentors, we have been tasked with the research, development, production, and testing of a system able to move a high viscosity liquid amine which requires adequate air exposure to absorb carbon dioxide from a habitat atmosphere in low gravity. The system is split into two main groups, fluids, and materials, with two separate teams of students assigned to their half of the design. The fluids team is responsible for everything in the design that directly touches the fluid. The materials team is responsible for the test stand to which the fluids team’s design is attached to as well as additive manufacturing material selection. In the first semester, the team focused on brainstorming ideas, design selection, budget creation, and CAD modeling. Multiple concepts were generated but the team decided on a design to get the high viscosity fluid to move around a rectangular channel using a screw conveyor mechanism. The liquid must be moved by the turning screw from the thermal chamber going around a rectangular trough back to the thermal chamber. The screw and the trough geometry will be important to allow for the high viscosity fluid to flow, utilizing surface tension to maintain contact to the trough as seen in Figure 1 below.

Olivia Angst↗

A 16-yr Comparison of Fine Particle and Aerosol Strong Acidity at the Interface Zone (1,540 m) and Within (452 m) the Planetary Boundary Layer of the Great Gulf and Presidential-Dry River Class I Wildernesses on the Presidential Range, New Hampshire

Mount Washington, NH in the White Mountain National Forest, is flanked to the north-northeast and south by two Class I Wilderness areas, the Great Gulf and Presidential Range-Dry River Wildernesses, respectively. The Clean Air Act protects Class I area natural resource values from air pollution. Aerosol sulfate, a fine particulate component that is often transported long distances, is a known contributor to visibility degradation and acidic deposition. We examined summertime fine particulate aerosol mass and sulfate, strong acidity and ammonium concentrations from 1988 to 2004 on Mount Washington at two elevations, 452 and 1,540 meters (msl). The former site is within, and the latter at the interface of, the planetary boundary layer. Comparisons of sampling interval durations (10 and 24 hours), site vs. site, and different sampling methods are made. We also examine the extent to which aerosol sulfate is neutralized. Ten hour (daytime) compared to 24 hour samples have higher mass and aerosol sulfate concentrations, however paired samples are well correlated. Fine mass concentrations compared between the 452 m and 1,540 m sites (standard temperature and pressure corrected) show a weak positive linear relationship with the later being approximately 34% lower. We attribute the lack of a strong correlation to the facts that the 1,540 m site is commonly at the interface of and even above the regional planetary boundary layer in summer and that it can intercept different air masses relative to the 452 m site. Sulfate is approximately 19% lower at the higher elevation site, but comprises a greater percentage of total fine mass; 42% compared to 35% for the high and low elevation site, respectively. Aerosol strong acidity was found to increase with increasing sulfate concentrations at both sites. At the high elevation site, elevated mass and sulfate concentrations are associated with westerly and southwesterly regional flows.

Murray, Georgia L.↗

Requirements and Design Reference Mission for the WFIRST-AFTA Coronagraph Instrument

The WFIRST-AFTA coronagraph instrument take s advantage of AFTA s 2.4 -meter aperture to provide novel exoplanet imaging science at approximately the same instrument cost as an Explorer mission. The AFTA coronagraph also matures direct imaging technologies to high TRL for an Exo-Earth Imager in the next decade. The coronagraph Design Reference Mission (DRM) optical design is based on the highly successful High Contrast Imaging Testbed (HCIT), with modifications to accommodate the AFTA telescope design, service-ability, volume constraints, and the addition of an Integral Field Spectrograph (IFS). In order to optimally satisfy the three science objectives of planet imaging, planet spectral characterization and dust debris imaging, the coronagraph is designed to operate in two different modes : Hybrid Lyot Coronagraph or Shaped Pupil Coronagraph. Active mechanisms change pupil masks, focal plane masks, yot masks, and bandpass filters to shift between modes. A single optical beam train can thus operate alternatively as two different coronagraph architecture s. Structural Thermal Optical Performance (STOP) analysis predict s the instrument contrast with the Low Order Wave Front Control loop closed. The STOP analysis was also used to verify that the optical/structural/thermal design provides the extreme stability required for planet characterization in the presence of thermal disturbances expected in a typical observing scenario. This paper describes the instrument design and the flow down from science requirements to high level engineering requirements.

contrast↗

Coupling Mars' Dust and Water Cycles: Effects on Dust Lifting Vigor, Spatial Extent and Seasonality

The dust cycle is an important component of Mars' current climate system. Airborne dust affects the radiative balance of the atmosphere, thus greatly influencing the thermal and dynamical state of the atmosphere. Dust raising events on Mars occur at spatial scales ranging from meters to planet-wide. Although the occurrence and season of large regional and global dust storms are highly variable from one year to the next, there are many features of the dust cycle that occur year after year. Generally, a low-level dust haze is maintained during northern spring and summer, while elevated levels of atmospheric dust occur during northern autumn and winter. During years without global-scale dust storms, two peaks in total dust loading were observed by MGS/TES: one peak occurred before northern winter solstice at Ls 200-240, and one peak occurred after northern winter solstice at L(sub s) 305-340. These maxima in dust loading are thought to be associated with transient eddy activity in the northern hemisphere, which has been observed to maximize pre- and post-solstice. Interactive dust cycle studies with Mars General Circulation Models (MGCMs) have included the lifting, transport, and sedimentation of radiatively active dust. Although the predicted global dust loadings from these simulations capture some aspects of the observed dust cycle, there are marked differences between the simulated and observed dust cycles. Most notably, the maximum dust loading is robustly predicted by models to occur near northern winter solstice and is due to dust lifting associated with down slope flows on the flanks of the Hellas basin. Thus far, models have had difficulty simulating the observed pre- and post- solstice peaks in dust loading. Interactive dust cycle studies typically have not included the formation of water ice clouds or their radiative effects. Water ice clouds can influence the dust cycle by scavenging dust from atmosphere and by interacting with solar and infrared radiation, thereby modifying the thermal structure of the atmosphere and its circulation. Results presented in other papers at this workshop show that including the radiative effects of water ice clouds greatly influence the water cycle and the vigor of weather systems in both the northern and southern hemispheres. Our goal is to investigate the effects of fully coupling the dust and water cycles on the dust cycle. We show that including water ice clouds and their radiative effects greatly affect the magnitude, spatial extent and seasonality of dust lifting and the season of maximum atmospheric dust loading.

Kahre, M. A.↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Lithologic controls on microfracturing from legacy underground nuclear explosions

Detection and verification of underground nuclear explosions (UNEs) can be improved with a better understanding of the nature and extent of explosion-induced damage in rock and the effect of this damage on radionuclide migration. Much of the previous work in this area has focused on centimeter- to meter-scale manifestations of damage, but to predict the effect of damage on permeability for radionuclide migration, observations at smaller scales are needed to determine deformation mechanisms. Based on studies of tectonic deformation in tuff, we expected that the heterogeneous tuff layers would manifest explosion-induced damage differently, with welded tuffs showing more fractures and nonwelded tuffs showing more deformation bands. In comparing post-UNE samples with lithologically matched pre-UNE equivalents, we observed damage in multiple lithologies of tuff through quantitative microfracture densities. We find that the texture (e.g., from deposition, welding, alteration, etc.) affects fracture densities, with stronger units fracturing more than weaker units. While we see no evidence of expected deformation bands in the nonwelded tuffs, we do observe, as expected, much larger microfracture densities at close range (<50 m) to the explosive source. We also observe a subtle increase in microfracture densities in post-UNE samples, relative to pre-UNE equivalents, in all lithologies and depths. The fractures that are interpreted to be UNE-induced are primarily transgranular and grain-boundary microfractures, with intragranular microfracture densities being largely similar to those of pre-UNE samples. This work has implications for models of explosion-induced damage and how that damage may affect flow pathways in the subsurface.

58 GEOSCIENCES↗