Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire effects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Charge-flow structures as polymeric early-warning fire alarm devices

The charge-flow transistor (CFT) and its applications for fire detection and gas sensing were investigated. The utility of various thin film polymers as possible sensing materials was determined. One polymer, PAPA, showed promise as a relative humidity sensor; two others, PFI and PSB, were found to be particularly suitable for fire detection. The behavior of the charge-flow capacitor, which is basically a parallel-plate capacitor with a polymer-filled gap in the metallic tip electrode, was successfully modeled as an RC transmission line. Prototype charge-flow transistors were fabricated and tested. The effective threshold voltage of this metal oxide semiconductor was found to be dependent on whether surface or bulk conduction in the thin film was dominant. Fire tests with a PFI-coated CFT indicate good sensitivity to smouldering fires.

Sechen, C. M.↗

Inhomogeneities of stratocumulus liquid water

There is a growing body of observational evidence on inhomogeneous cloud structure, most recently from the extensive measurements of the FIRE field program. Knowledge of cloud structure is important because it strongly influences the cloud radiative properties, one of the major factors in determining the global energy balance. Current atmospheric circulation models use plane-parallel radiation, so that the liquid water in each gridbox is assumed to be uniform, which gives an unrealistically large albedo. In reality cloud liquid water occupies only a subset of each gridbox, greatly reducing the mean albedo. If future climate models are to treat the hydrological cycle in a manner consistent with energy balance, a better treatment of cloud liquid is needed. FIRE concentrated upon two cloud types of special interest: cirrus and marine stratocumulus. Cirrus tend to be high and optically thin, thus reducing the effective radiative temperature without increasing the albedo significantly, leading to an enhanced greenhouse heating. In contrast, marine stratocumulus are low and optically thick, thus producing a large increase in reflected radiation with a small change in emitted radiation, giving a net cooling which could potentially mitigate the expected greenhouse warming. The FIRE measurements in California stratocumulus during June and July of 1987 show variations in cloud liquid water on all scales. Such variations are associated with inhomogeneous entrainment, in which entrained dry air, rather than mixing uniformly with cloudy air, remains intact in blobs of all sizes, which decay only slowly by invasion of cloudy air. Two important stratocumulus observations are described, followed by a simple fractal model which reproduces these properties, and finally, the model radiative properties are discussed.

Cahalan, Robert F.↗

Effect of off-design operation of MHD generators on NO/x/ chemical kinetics

The purpose of this study is to provide a capability for determining the chemical kinetic behavior of one family of pollutants, the nitrogen oxides, in the flow of a coal-fired MHD generator facility. The method used in the study allows the prediction of the nonequilibrium concentration of the minor NO(x) species in a flow otherwise assumed in equilibrium. Consideration is given to the effect of preheat, stoichiometry, and oxygen enrichment of the NO(x) concentration. The effect of preheat and stoichiometry is found to have a significant influence on the NO(x) concentration at the exit of the radiant boiler.

Simmons, G. A.↗

Effects of Humidity on Aerosols in Southern Africa during the Biomass Burning Season

Measurements of the aerosol total light scattering coefficient, asp, and the aerosol hemispheric backscatter ratio, p(1), as functions of relative humidity (RH in %) (so-called humidographs) at three wavelengths (450,550, and 700 nm) were obtained in the dry season in southern Africa (1) in ambient air in South Africa, Botswana, Mozambique and Zambia, (2) at various distances downwind in identifiable smoke plumes from biomass fires, and (3) along the southwest coast of Africa. The ratio of sigma(sub sp) at an RH of 80% to that at 30% provides a measure of the effects of RH on sigma(sub sp), and similarly for Beta(1). For the three broad sampling categories given above, and at a wavelength of 550 nm, these ratios varied from 1.42 +/- 0.05 to 2.07 +/- 0.03 for sigma(sub sp), and from 0.69 +/- 0.05 to 0.99 +/- 0.14 for Beta(1). In general, humidographs for the ambient air samples showed a greater dependence on RH than those for smoke from identifiable biomass fires. During a period when dense, aged smoke was transported to the region from the north, the humidographs for sigma(sub sp) for ambient air samples were similar to those for identifiable smoke plume samples just approximately 10- to 50-min old. This suggests that as far as the effects of RH on sigma(sub sp) are concerned the effects of aging of smoke and its mixing with ambient air are realized within less than about an hour.

Magi, Brian I.↗

An investigation of enhanced capability thermal barrier coating systems for diesel engine components

Material systems and processes for the development of effective and durable thermal barriers for heavy duty diesel engines were investigated. Seven coating systems were evaluated for thermal conductivity, erosion resistance, corrosion/oxidation resistance, and thermal shock resistance. An advanced coating system based on plasma sprayed particle yttria stabilized zirconia (PS/HYSZ) was judged superior in these tests. The measured thermal conductivity of the selected coating was 0.893 W/m C at 371 C. The PS/HYSZ coating system was applied to the piston crown, fire deck and valves of a single cylinder low heat rejection diesel engine. The coated engine components were tested for 24 hr at power levels from 0.83 MPa to 1.17 MPa brake mean effective pressure. The component coatings survived the engine tests with a minimum of distress. The measured fire deck temperatures decreased 86 C (155 F) on the intake side and 42 C (75 F) on the exhaust side with the coating applied.

Holtzman, R. L.↗

Experimental Investigation on Effect of Smoke Management System in a High-large Atrium

In an atrium measured 120 m by 180 m by 36.5 m high, fire tests were conducted under 'natural filling' and 'mechanical exhaust' conditions by hot smoke test method. The fire size was 8 MW released by an ethanol pool of 3.6 m in diameter. The distribution of vertical temperature profiles above the fire source and the gas layer temperatures were measured. From these measurements, it was shown that the fans successfully exhausted hot smoke to control descending of hot smoke layer and temperature rising rate. The hot smoke layer can be maintained at about 30 m which was almost 2 times of hot layer height in 'natural filling' condition. The temperature risings in both conditions were too low to cause thermal damage to the structure, only 18.6 K and 12 K. The centerline temperature above the fire source and the height of hot smoke layer were calculated using the plume models. The calculated results agreed well with the conclusions obtained from the experiment results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Trial by Fire? Rulewriters, Training, the BLM, and EPA

Individual bureaucrats are ultimately tasked with solving complex problems and are expected to do so cost-effectively. The purpose of this paper is to examine an infrequent perspective of administrative rulemaking - training. Simply put, our goal is to examine original interview data with federal rulewriters in two agencies - the Environmental Protection Agency and the Bureau of Land Management to understand how bureaucrats are trained to carry out rules. This exploratory study suggests the importance of training for the next generation of rulewriters. In particular, we demonstrate existing informal training can be effective, but more mechanisms (e.g. formal training and mentoring) is necessary.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mitigation for the demolition of building 25-3153, fire station, area 25, Nevada national security site, NYE county, Nevada

The purpose of this letter report is to document the mitigation of adverse effects of a proposed undertaking that would demolish Building 25-3153 in Area 25 of the Nevada National Security Site (NNSS) in compliance with the terms of the 2024 Programmatic Agreement among the U.S. Department of Energy and the Nevada State Historic Preservation Officer and the Advisory Council on Historic Preservation Concerning the Protection of Historic Properties on the Nevada National Security Site, Nye County, Nevada (NNSS PA). Building 25-3153 (State Historic Preservation Office [SHPO] Resource # B19004) is a contributing element to the Nuclear Rocket Development Station (NRDS) Historic District (SHPO Resource # D424), which has been determined eligible for listing in the National Register of Historic Places (NRHP) under Criteria A, B, C, and D (Reno et al. 2023). The proposed demolition constitutes an adverse effect. The U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Field Office (NNSA/NFO) consulted with the SHPO on an adverse effect finding for the undertaking and notified the SHPO of its intent to use the standard mitigation in the NNSS PA on December 11, 2024 (Julian to Reed). The SHPO concurred on December 30, 2024 (Reed to Julian). Therefore, NNSA/NFO has prepared mitigation pursuant to the standard mitigation in the NNSS PA Appendix D.I.A for contributing elements to recorded, NRHP-eligible districts.

#B19004↗

Long-Term Carbon Injection Field Test for 90% Mercury Removal for a PRB Unit a Spray Dryer and Fabric Filter

The power industry in the U.S. is faced with meeting regulations to reduce the emissions of mercury compounds from coal-fired plants. Injecting a sorbent such as powdered activated carbon (PAC) into the flue gas represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. The purpose of this test program was to evaluate the long-term mercury removal capability, long-term mercury emissions variability, and operating and maintenance (O&M) costs associated with sorbent injection on a configuration being considered for many new plants. Testing was conducted by ADA Environmental Solutions (ADA) at Rocky Mountain Power’s (RMP) Hardin Station through funding provided by DOE/NETL, RMP, and other industry partners. The Hardin Station is a new plant rated at 121 MW gross that was first brought online in April of 2006. Hardin fires a Powder River Basin (PRB) coal and is configured with selective catalytic reduction (SCR) for NOx control, a spray dryer absorber (SDA) for SO2 control, and a fabric filter (FF) for particulate control. Based upon previous testing at PRB sites with SCRs, very little additional mercury oxidation from the SCR was expected at Hardin. In addition, based upon results from DOE/NETL Phase II Round I testing at Holcomb Station and results from similarly configured sites, low native mercury removal was expected across the SDA and FF. The main goal of this project was met—sorbent injection was used to economically and effectively achieve 90% mercury control as measured from the air heater (AH) outlet to the stack for a period of ten months. This goal was achieved with DARCO® Hg-LH, Calgon FLUEPAC®-MC PLUS and ADA Power PAC PREMIUM brominated activated carbons at nominal loadings of 1.5–2.5 lb/MMacf. An economic analysis determined the twenty-year levelized cost to be 0.87 mills/kW-hr, or $15,000/lb Hg removed. No detrimental effects on other equipment or plant operations were observed. The results of this project also filled a data gap for plants firing PRB coal and configured with an SCR, SDA, and FF, as many new plants are being designed today. Another goal of the project was to evaluate, on a short-term basis, the mercury removal associated with coal additives and coal blending with western bituminous coal. The additive test showed that, at this site, the coal additive known as KNX was affective at increasing mercury removal while decreasing sorbent usage. Coal blending was conducted with two different western bituminous coals, and West Elk coal increased native capture from nominally 10% to 50%. Two additional co-benefits were discovered at this site. First, it was found that native capture increased from nominally 10% at full load to 50% at low load. The effect is believed to be due to an increase in mercury oxidation across the SCR caused by a corresponding decrease in ammonia injection when the plant reduces load. Less ammonia means more active oxidation sites in the SCR for the mercury. The second co-benefit was the finding that high ammonia concentrations can have a negative impact on mercury removal by powdered activated carbon. For a period of time, the plant operated with a high excess of ammonia injection necessitated by the plugging of one-third of the SCR. Under these conditions and at high load, the mercury control system could not maintain 90% removal even at the maximum feed rate of 3.5 lb/MMacf (pounds of mercury per million actual cubic feet). The plant was able to demonstrate that mercury removal was directly related to the ammonia injection rate in a series of tests where the ammonia rate was decreased, causing a corresponding increase in mercury removal. Also, after the SCR was refurbished and ammonia injection levels returned to normal, the mercury removal performance also returned to normal. Another goal of the project was to install a commercial-grade activated carbon injection (ACI) system and integrate it with new-generation continuous emissions monitors for mercury (Hg-CEMs) to allow automatic feedback control on outlet mercury emissions. This was accomplished and the plant can now be operated to control carbon injection based on either the overall mercury removal or an outlet mercury emission rate. By integrating these systems, it was determined that the plant could reduce powdered activated carbon consumption, especially at low load, because, at Hardin, native mercury capture increases from less than 20% to about 50% at low load and the carbon injection rate can be decreased accordingly. Currently, the plant is operating to automatically control emissions to below 0.9 lb/TBtu (pounds of mercury per million British thermal units) at carbon loadings of 0.5 to 1.5 lb/MMacf. During the final phase of the Long-Term test, the ACI system was operated by plant personnel. The estimated O&M cost for a single Hg-CEM system is $15,500/yr. The Hg-CEMs performed well throughout the project. This project began shortly after Thermo Fisher first offered the Mercury Freedom System™ on a commercial basis and progressed though several iterations, improvements, and upgrades to the hardware and software. Indeed, there was a ten-fold increase in the precision and accuracy of the units during the course of the project due to several successful upgrades. In their present condition, the Hg-CEMs measure mercury to a precision of about ± 0.05 μg/wscm (micrograms of mercury per wet standard cubic meter of gas), and only require occasional fine-tuning of the calibration coefficients. The quality assurance/quality control (QA/QC) protocol required to keep the units operating at their optimal performance was also developed and perfected during the course of the project. ADA Environmental Solutions (ADA) developed a daily calibration procedure that surpasses the requirements specified in the Clean Air Mercury Rule (CAMR), and a weekly diagnostic program that ensures that the systems are operating properly and receive the necessary maintenance. For the most part, the systems passed the daily, weekly, and quarterly QA/QC requirements as well as four performance verification tests using the Ontario Hydro (O-H) and Sorbent Trap Methods (STM) for the first test and the EPA Method 30A (M30A) procedure for the remaining three. However, some improvements are still necessary before the system can meet all of the requirements. These involve tests that challenge the system with oxidized mercury (Hg+2). These tests could not be passed at Hardin in spite of trying several improvements suggested by ADA or Thermo Fisher.

20 FOSSIL-FUELED POWER PLANTS↗

Probing the Effects of NO x and SO x Impurities on Oxy-Fuel Combustion in Supercritical CO 2 : Shock Tube Experiments and Chemical Kinetic Modeling

The direct-fired supercritical carbon dioxide cycles are one of the most promising power generation methods in terms of their efficiency and environmental friendliness. Two important challenges in implementing these cycles are the high pressure (300 bar) and high CO 2 dilution (>80%) in the combustor. The design and development of supercritical oxy-combustors for natural gas require accurate reaction kinetic models to predict the combustion outcomes. The presence of a small amount of impurities in natural gas and other feed streams to oxy-combustors makes these predictions even more complex. During oxy-combustion, trace amounts of nitrogen present in the oxidizer is converted to NO x and gets into the combustion chamber along with the recirculated CO 2 . Similarly, natural gas can contain a trace amount of ammonia and sulfurous impurities that get converted to NO x and SO x and get back into the combustion chamber with recirculated CO 2 . In this work, a reaction model is developed for predicting the effect of impurities such as NO x and SO x on supercritical methane combustion. The base mechanism used in this work is GRI Mech 3.0. H 2 S combustion chemistry is obtained from Bongartz et al. while NOx chemistry is from Konnov. The reaction model is then optimized for a pressure range of 30–300 bar using high-pressure shock tube data from the literature. It is then validated with data obtained from the literature for methane combustion, H 2 S oxidation, and NO x effects on ignition delay. The effect of impurities on CH 4 combustion up to 16 atm is validated using NO x -doped methane studies obtained from the literature. In order to validate the model for high-pressure conditions, experiments are conducted at the UCF shock tube facility using natural gas identical mixtures with N 2 O as an impurity at ~100 bar. Current results show that there is a significant change in ignition delay with the presence of impurities. A comparison is made with experimental data using the developed model and predictions are found to be in good agreement. The model developed was used to study the effect of impurities on CO formation from sCO 2 combustors. It was found that NO x helps in reducing CO formation while the presence of H 2 S results in the formation of more CO. The reaction mechanism developed herein can also be used as a base mechanism to develop reduced mechanisms for use in CFD simulations.

Energy & Fuels↗

Processes Influencing Ozone Levels in Alaskan Forest Fires Plumes during Long-Range Transport over the North Atlantic

A case of long-range transport of a biomass burning plume from Alaska to Europe is analyzed using a Lagrangian approach. This plume was sampled several times in the free troposphere over North America, the North Atlantic and Europe by 3 different aircraft during the IGAC Lagrangian 2K4 experiment which was part of the ICARTT/ITOP measurement intensive in summer 2004. Measurements in the plume showed enhanced values of CO, VOCs and NOy, mainly in form of PAN. Observed O3 levels increased by 17 ppbv over 5 days. A photochemical trajectory model, CiTTyCAT, is used to examine processes responsible for the chemical evolution of the plume. The model was initialized with upwind data, and compared with downwind measurements. The influence of high aerosol loading on photolysis rates in the plume is investigated using in-situ aerosol measurements in the plume and lidar retrievals of optical depth as input into a photolysis code (Fast-J), run in the model. Significant impacts on photochemistry are found with a decrease of 18 percent in O3 production and 24 percent in O3 destruction over 5 days when including aerosols. The plume is found to be chemically active with large O3 increases attributed primarily to PAN decomposition during descent of the plume towards Europe. The predicted O3 changes are very dependent on temperature changes during transport, and also, on water vapor levels in the lower troposphere which can lead to O3 destruction. Simulation of mixing/dilution was necessary to reproduce observed pollutants level in the plume. Mixing was simulated using background concentrations from measurements in air masses in close proximity to the plume, and mixing timescales (averaging 6.25 days) were derived from CO changes. Observed and simulated O3/CO correlations in the plume are also compared in order to evaluate the photochemistry in the model. Observed slopes changed from negative to positive over 5 days. This change, which can be attributed largely to photochemistry, is well reproduced by multiple model runs even if slope values are slightly underestimated suggesting small underestimation of photochemical processes. The possible impact of this biomass burning plume on O3 levels in the Europe boundary layer is also examined by running the model for a further 5 days, and comparing with data collected at surface sites, such as Jungfraujoch, which showed small O3 increases and elevated CO levels. The model predicts significant changes in O3 over this 10 days due to photochemistry but the signal is largely lost due to the effects of dilution. However, measurement in several others BB plumes over Europe show that O3 impact of Alaskan fires can be punctually significant over Europe.

Real, E.↗

Modeling the Impact of Baryons on Subhalo Populations with Machine Learning

Here, we identify subhalos in dark matter–only (DMO) zoom-in simulations that are likely to be disrupted due to baryonic effects by using a random forest classifier trained on two hydrodynamic simulations of Milky Way (MW)–mass host halos from the Latte suite of the Feedback in Realistic Environments (FIRE) project. We train our classifier using five properties of each disrupted and surviving subhalo: pericentric distance and scale factor at first pericentric passage after accretion and scale factor, virial mass, and maximum circular velocity at accretion. Our five-property classifier identifies disrupted subhalos in the FIRE simulations with an 85% out-of-bag classification score. We predict surviving subhalo populations in DMO simulations of the FIRE host halos, finding excellent agreement with the hydrodynamic results; in particular, our classifier outperforms DMO zoom-in simulations that include the gravitational potential of the central galactic disk in each hydrodynamic simulation, indicating that it captures both the dynamical effects of a central disk and additional baryonic physics. We also predict surviving subhalo populations for a suite of DMO zoom-in simulations of MW-mass host halos, finding that baryons impact each system consistently and that the predicted amount of subhalo disruption is larger than the host-to-host scatter among the subhalo populations. Although the small size and specific baryonic physics prescription of our training set limits the generality of our results, our work suggests that machine-learning classification algorithms trained on hydrodynamic zoom-in simulations can efficiently predict realistic subhalo populations.

79 ASTRONOMY AND ASTROPHYSICS↗

Connected Lighting Systems Efficiency Study: PoE Cable Energy Losses, Part 2

DOE published a report in November 2017 (herein referred to as “Part 1”) summarizing the results of an exploratory study investigating power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the Pacific Northwest National Laboratory (PNNL) Connected Lighting Test Bed (CLTB) in September 2017. The results were analyzed to explore the impact of cable selection on PoE lighting system energy efficiency, as well as the effectiveness of guidelines published by the American National Standards Institute (ANSI) C137 Lighting Systems Committee in 2017. The guidance offered in ANSI C137.3-2017 was found to be effective in limiting cable energy losses to 5% in PoE lighting applications, provided that the average cable length on a project does not exceed 50 m. This Part 2 report summarizes the results of a continued investigation of the power losses in Ethernet cables used between PoE switches and luminaires in PoE connected lighting systems. Testing was conducted at the PNNL CLTB in July-August 2018. A test setup comprising a PoE switch, a set of luminaires, and a reference meter was again used to test multiple cable models of varying design. The results were analyzed to explore the impact of cable selection and installation practices (e.g., cable bending, cable bundling, and installation in conduit) on PoE lighting system energy efficiency, as well as the effectiveness of the ANSI C137.3 guidelines. Notably, three cables—two of which were shielded—were previously excluded from the Part 1 study due to compatibility issues. All three cables were included in this Part 2 study, along with a fourth model cable introduced in Part 2. In addition, whereas no patch cords were used in Part 1, patch cords were used in some Part 2 testing. The ANSI C137.3 guidance was again shown to effectively limit power losses to less than 5% in the cables tested (varying in AWG, Category, shielding, fire rating, and manufacturer), and AWG again proved to be the most important cable design variable for energy performance, as expected. However, these findings should not be construed as being representative of all cable models and installation practices. For example, energy losses would be greater when cables are connected to patch cords, bundled in conduit, and loaded with powered devices (PDs) approaching 100 W input power. The other key finding was that with 44 W luminaires as PDs and room ambient temperatures below 30°C, cable energy losses were not substantially increased by cable bending or bundling in uninsulated conduit. However, environments with higher ambient temperatures will have greater energy losses due to increased conductor DCR. In addition, product selection and installation practices will have increased importance as PDs approaching 100 W input power—conveyed by a single Ethernet cable—are introduced following publication of the forthcoming Institute of Electrical and Electronics Engineers (IEEE) Standard 802.3bt. The report also provides recommendations and next steps, which include plans for additional PoE cable energy losses testing with higher-power PDs to more fully explore the potential of PoE lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Trace Element Sampling and Partitioning Modeling to Estimate Wastewater Composition and Treatment Performance at Coal Generators

The coal combusted at coal-fired power plants (CFPPs) contains several trace elements that impact human heath if released to the environment. Effective combinations of air pollution control devices (APCDs) and water pollution control devices (WPCDs) are critical to reducing these impacts. This work sampled pulverized CFPPs owned and operated by Louisville Gas & Electricity – Kentucky Utilities (LGE-KU) during baseload and cycling conditions. Next, an open-source and easy-to-implement trace element partitioning model was developed using publicly available datasets, literature studies of trace element partitioning, and sampling data to estimate trace element partitioning in APCDs to the gas, liquid, and solid phases exiting CFPPs. These estimates of the liquid phase trace element concentration in FGD wastewater were then used to estimate trace element behavior in WPCDs and evaluate treated wastewater effluent concentrations for compliance with the Effluent Limitation Guidelines (ELG) for the Steam Electric Generating Sector. Finally, cost estimates were developed for established and emerging wastewater treatment trains to identify the most cost-effective approaches for ELG compliance.

01 COAL, LIGNITE, AND PEAT↗

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal Insulative Elastomers for Clustered Large Liquid Propellant Rocket Engines

As thrust levels increase and as rocket engines fire for longer periods of time, the difficulties encountered in the protection of critical components from the effects of excessively high temperatures greatly increase. To protect these components a series of filled elastomeric composites have been evaluated. A brief discussion is presented of the problems of hot gas recirculation, radiation, and base plane heating with particular reference to large, clustered, liquid propellant rocket engines. The effect on components is discussed and an evaluation of a series of insulators based on filled elastomeric composites is presented. The evaluations are based on specialized thermal tests which were designed to simulate as far as possible, conditions during flight. The most promising of these elastomeric composites are compared to three alternative insulative systems, a filled, castable ceramic, a metal foil-silica fiber batting, and an asbestos-inconel wire mesh composite, in terms of weight, cost, and ease of fabrication and repair.

Peters, S. T.↗

Analysis of thermal environment in the thrustor cavity of space vehicles

Wind tunnel tests to determine the mechanisms involved in producing the high local heating rates in and around the thrustor nozzle in a non-firing condition are reported. The geometry of a typical nozzle installation is described. Procedures for reducing the effects of hypersonic flow interactions in order to prevent excess local heating are explained.

Chiou, J. N.↗