Experimental Equipment Design and Fabrication Study for Delta-G Experiment
The Research Machine Shop at UAH did not develop any new technology in the performance of the following tasks. All tasks were performed as specified.UAH RMS shall design and fabricate a "poor" model of a silicon-carbide high-temperature crucible with dimensions of 8 inches in diameter and 4 inches high-temperature crucible for pouring liquid ceramic materials at 1200 C into molds from heating ovens. The crucible shall also be designed with a manipulation fixture to facilitate holding and pouring of the heated liquid material. UAH RMS shall investigate the availability of 400 Hz, high-current (65 volts @ 100 amperes) power systems for use in high-speed rotating disk experiments, UAH RMS shall investigate, develop a methodology, and experiment on the application of filament-wound carbon fibers to the periphery of ceramic superconductors to withstand high levels of rotational g-forces. UAH RMS shall provide analytical data to verify the resulting improved disc with carbon composite fibers.