Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Characteristics of plasma grid bias in large-scaled negative ion source

The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Improved Chemistry and Attenuation Models for Communication Blackout Simulation During Mars 2020 Entry

As a blunt body enters a planetary atmosphere, a plasma forms in the hypersonic shock layer and attenuates radio communication causing signal blackout for some duration of the entry sequence. In our previous work,1 computational fluid dynamics (CFD) was applied to model the entry flow around the Mars 2020 spacecraft, including ionization and electron density throughout the flow field, and predict ultra-high frequency (UHF) radio wave attenuation due to electrons. In total, 17 chemical species and their spatial profiles are modelled around the Mars 2020 spacecraft at 11 different points in time during entry. Although the simulation predicted the onset of attenuation well, the timing of the end of the predicted blackout window significantly preceded the end time observed during the 2021 landing. The present work seeks to improve the attenuation model by accounting for the fact that electrons undergo collisions with heavier species in the flow, which is an effect that was neglected in previous analyses. It is determined that including electron collisions increases the overall magnitude of attenuation predicted especially towards the end of the measured attenuation period, improving qualitative agreement between predicted and measured attenuation to both spacecraft receiving the signal from Mars 2020. To explore the remaining uncertainty in signal attenuation predictions further, a sensitivity study is performed to investigate the impact of associative ionization and electron-impact ionization rate coefficients on the electron density predicted by CFD and on the resulting attenuation predictions. These coefficients are believed to contain up to order-of-magnitude uncertainty, and therefore may significantly affect the number density of electrons throughout the flow field. Variations in associative ionization coefficients demonstrate significant impact on the magnitude of attenuation due to variation in the electron density coming from associative ionization. However, the start and end times of the predicted signal attenuation period are only slightly impacted by said variation.

Eve Papajak↗

Test particle simulation of the role of ballistic electrons in hybrid dc/rf capacitively coupled CF{sub 4} plasmas

Hybrid dc/rf plasma sources are an emerging equipment technology in plasma etching for semiconductor manufacturing. In this type of plasma source, ballistic electrons originate as secondary electrons on a dc/rf (i.e., VHF, 60 MHz) biased electrode and are then accelerated in the sheath toward an opposite non-dc biased lower electrode. For electropositive (argon) plasmas it has been shown that the primary contribution of ballistic electrons is ionization in the dc sheath and modulation of the discharge properties. Whether applied dc power net increases or decreases the plasma electron density depends on the rf power environment of the opposing substrate electrode. When rf power is applied to a substrate electrode, the rf self-bias creates a potential well that traps the ballistic electrons, the result being that the electron density increases with dc power. In most cases the fraction of high energy electrons that reach the electrode is small. In this article, the authors describe the use of test particle Monte Carlo simulations to describe the behavior of hybrid dc/rf electronegative (CF{sub 4}) plasmas. In contrast to the behavior in argon, process experiments with electronegative gases such as CF{sub 4} indicate that the electron density is independent of dc bias power when no rf power is applied to the wafer. Test particle simulations show that CF{sub 4} provides for a 'self-confinement' effect caused by large cross sections for vibrational excitation at intermediate to low electron energies, which results in weak dependence of electron density on dc bias voltage when low frequency bias is not applied to the wafer. This emphasizes the important role of gas composition and cross-section structure in the control of dc/rf plasmas. Consistent with experiment, test particle Monte Carlo simulations also show that when rf is applied to the substrate, overall the CF{sub 4} plasma's macroscopic properties are similar manner to argon plasmas. Even so, differences between the argon and CF{sub 4} plasmas occur related to the scaling of the fraction of ballistic electrons that reach the wafer as a function of dc and rf power. A regime is identified in which CF{sub 4} and argon plasmas have the equivalent ratio of ballistic to thermal electron density adjacent to the surface. The authors explain that the differences are related to different thermalization and ionization mechanisms in these plasmas. In addition, they find the electron attachment constant is zero in the dc sheath and nearly constant value in the bulk as the transit time in the sheath is far less than the mean attachment time. The same simple function to express ionization rate constant as a function of electric field in the dc sheath, developed for argon, can be also applied to CF{sub 4}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of electromagnetic wave scattering from an inhomogeneous plasma layer using Green's function volume integral equation method

Gigahertz electromagnetic wave scattering from an inhomogeneous collisional plasma layer with bell-like and Epstein electron density distributions is studied by the Green's function volume integral equation method to find the reflectance, transmittance, and absorbance coefficients of this inhomogeneous plasma. Also, the effects of the frequency of the electromagnetic wave, plasma parameters, such as collision frequency, electron density, and plasma thickness, and the effects of the profile of the electron density on the electromagnetic wave scattering from this plasma slab are investigated. According to the results, when the electron density, collision frequency, and plasma thickness are increased, collisional absorbance is enhanced, and as a result, the absorbance bandwidth of plasma is broadened. Moreover, this broadening is more evident for plasma with bell-like electron density profile. Also, the bandwidth of the frequency and the range of pressure in which plasma behaves as a good reflector are determined in this article. According to the results, the bandwidth of the frequency is decreased for thicker plasma with bell-like profile, while it does not vary for a different plasma thickness with Epstein profile. Moreover, the range of the pressure is decreased for bell-like profile in comparison with Epstein profile. Furthermore, due to the sharp inhomogeneity of the Epstein profile, the coefficients of plasma that are uniform for plasma with bell-like profile are changed for plasma with Epstein profile, and some perturbations are seen.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NON-EQUILIBRIUM IONIZATION EFFECTS ON THE DENSITY LINE RATIO DIAGNOSTICS OF O IV

The dynamic timescales in the solar atmosphere are shorter than the ionization and recombination times of many ions used for line ratio diagnostics of the transition region and corona. The long ionization and recombination times for these ions imply that they can be found far from their equilibrium temperatures, and spectroscopic investigations require more care before being trusted in giving correct information on local quantities, such as density and temperature. By solving the full time-dependent rate equations for an oxygen model atom in the three-dimensional numerical model of the solar atmosphere generated by the Bifrost code, we are able to construct synthetic intensity maps and study the emergent emission. We investigate the method of electron density diagnostics through line ratio analysis of the O IV 140.1 nm to the 140.4 nm ratio, the assumptions made in carrying out the diagnostics, and the different interpretations of the electron density. The results show big discrepancies between emission in statistical equilibrium and emission where non-equilibrium (NEQ) ionization is treated. Deduced electron densities are up to an order of magnitude higher when NEQ effects are accounted for. The inferred electron density is found to be a weighted mean average electron density along the line of sight and has no relation to the temperature of emission. This study shows that numerical modeling is essential for electron density diagnostics and is a valuable tool when the ions used for such studies are expected to be out of ionization equilibrium. Though this study has been performed on the O IV ion, similar results are also expected for other transition region ions.

79 ASTRONOMY AND ASTROPHYSICS↗

FREQUENCY-DEPENDENT DISPERSION MEASURES AND IMPLICATIONS FOR PULSAR TIMING

The dispersion measure (DM), the column density of free electrons to a pulsar, is shown to be frequency dependent because of multipath scattering from small-scale electron-density fluctuations. DMs vary between propagation paths whose transverse extent varies strongly with frequency, yielding arrival times that deviate from the high-frequency scaling expected for a cold, uniform, unmagnetized plasma (1/frequency{sup 2}). Scaling laws for thin phase screens are verified with simulations; extended media are also analyzed. The rms DM difference across an octave band near 1.5 GHz is ∼ 4 × 10{sup −5} pc cm{sup −3} for pulsars at ∼1 kpc distance. The corresponding arrival-time variations are a few to hundreds of nanoseconds for DM ≲ 30 pc cm{sup −3} but increase rapidly to microseconds or more for larger DMs and wider frequency ranges. Chromatic DMs introduce correlated noise into timing residuals with a power spectrum of “low pass” form. The correlation time is roughly the geometric mean of the refraction times for the highest and lowest radio frequencies used, ranging from days to years, depending on the pulsar. We discuss implications for methodologies that use large frequency separations or wide bandwidth receivers for timing measurements. Chromatic DMs are partially mitigable by including an additional chromatic term in arrival time models. Without mitigation, an additional term in the noise model for pulsar timing is implied. In combination with measurement errors from radiometer noise, an arbitrarily large increase in total frequency range (or bandwidth) will yield diminishing benefits and may be detrimental to overall timing precision.

79 ASTRONOMY AND ASTROPHYSICS↗

Ligand placement based on prior structures: the guided ligand-replacement method

A new module, Guided Ligand Replacement (GLR), has been developed in Phenix to increase the ease and success rate of ligand placement when prior protein-ligand complexes are available. The process of iterative structure-based drug design involves the X-ray crystal structure determination of upwards of 100 ligands with the same general scaffold (i.e. chemotype) complexed with very similar, if not identical, protein targets. In conjunction with insights from computational models and assays, this collection of crystal structures is analyzed to improve potency, to achieve better selectivity and to reduce liabilities such as absorption, distribution, metabolism, excretion and toxicology. Current methods for modeling ligands into electron-density maps typically do not utilize information on how similar ligands bound in related structures. Even if the electron density is of sufficient quality and resolution to allow de novo placement, the process can take considerable time as the size, complexity and torsional degrees of freedom of the ligands increase. A new module, Guided Ligand Replacement (GLR), was developed in Phenix to increase the ease and success rate of ligand placement when prior protein–ligand complexes are available. At the heart of GLR is an algorithm based on graph theory that associates atoms in the target ligand with analogous atoms in the reference ligand. Based on this correspondence, a set of coordinates is generated for the target ligand. GLR is especially useful in two situations: (i) modeling a series of large, flexible, complicated or macrocyclic ligands in successive structures and (ii) modeling ligands as part of a refinement pipeline that can automatically select a reference structure. Even in those cases for which no reference structure is available, if there are multiple copies of the bound ligand per asymmetric unit GLR offers an efficient way to complete the model after the first ligand has been placed. In all of these applications, GLR leverages prior knowledge from earlier structures to facilitate ligand placement in the current structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporally and spatially resolved characterization of microwave induced argon plasmas: Experiment and modeling

Experiments and modeling of the plasma-microwave interaction have been performed in a coaxial microwave plasma source at a field frequency of 2.45 GHz generating argon plasmas at pressures of 20 and 40 millibars and a ratio of flow rate to pressure of 0.125 sccm/Pa. The incident microwave power between 100 W and 300 W is supplied in a regime of a pulse-width modulation with cycle duration of 110 ms and a power-on time of 23 ms. The experiments are based on heterodyne reflectometry and microwave interferometry at 45.75 GHz. They provide the temporal behaviour of the complex reflection coefficient, the microwave power in the plasma, as well as the electron density in the afterglow zone of the discharge. The self-consistent spatially two-dimensional and time-dependent modeling complements the analysis of the plasma-microwave interaction delivering the plasma and electromagnetic field parameters. The consolidating experimental observations and model predictions allow further characterizing the plasma source. The generated plasma has a core occupying the region close to the end of the inner electrode, where maximum electron densities above 10{sup 20} m{sup −3} and electron temperatures of about 1 eV are observed. Due to a longer outer electrode of the coaxial structure, the plasma region is extended and fills the volume comprised by the outer electrode. The electron density reaches values of the order of 10{sup 19} m{sup −3}. The heating of the gas occurs in its great part due to elastic collisions with the plasma electrons. However, the contribution of the convective heating is important especially in the extended plasma region, where the gas temperature reaches its maximum values up to approximately 1400 K. The temporally and spatially resolved modeling enables a thorough investigation of the plasma-microwave interaction which clearly shows that the power in-coupling occurs in the region of the highest electron density during the early stage of the discharge. In the steady state phase, however, the power in-coupling occurs close to the source walls where the electron density is significantly lower than on the discharge axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of electronic structure of as grown and solar grade silicon samples

A comparison of the electronic structure of two different types of silicon materials viz., (i) as grown silicon and (ii) solar silicon has been carried out utilizing maximum entropy method and pair distribution function using powder X-ray data sets. The precise electron density maps have been elucidated for the two samples. The covalent nature of the bonding between atoms in both the samples is found to be well pronounced and clearly seen from the electron density maps. The electron densities at the middle of the Si-Si bond are found to be 0.47 and 0.45 e/A{sup 3} for as grown silicon and solar silicon respectively. In this work, the local structural information has also been obtained by analyzing the atomic pair distribution functions of these two samples.

36 MATERIALS SCIENCE↗

Measurement of a density profile of a hot-electron plasma in RT-1 with three-chord interferometry

The electron density profile of a plasma in a magnetospheric dipole field configuration was measured with a multi-chord interferometry including a relativistic correction. In order to improve the accuracy of density reconstruction, a 75 GHz interferometer was installed at a vertical chord of the Ring Trap 1 (RT-1) device in addition to previously installed ones at tangential and another vertical chords. The density profile was calculated by using the data of three-chord interferometry including relativistic effects for a plasma consisting of hot and cold electrons generated by electron cyclotron resonance heating (ECH). The results clearly showed the effects of density peaking and magnetic mirror trapping in a strongly inhomogeneous dipole magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization by energetic electrons in the midlatitude nighttime E region

Observations of the electron density profile and flux of energetic electrons obtained in two rocket flights at Wallops Island near midnight are presented. The ionization rates of the upper E region deduced from the electron density profiles are found to support the dependence on Kp established in previous observation. Calculations of the ionization rates using the observed electron fluxes show agreement with the values derived from the electron density profiles.

Smith, L. G.↗

The 7 × 1 Fermi Surface Reconstruction in a Two-dimensional f -electron Charge Density Wave System: PrTe 3

The electronic structure of a charge density wave (CDW) system PrTe 3 and its modulated structure in the CDW phase have been investigated by employing ARPES, XAS, Pr 4 f RPES, and first-principles band structure calculation. Pr ions are found to be nearly trivalent, supporting the CDW instability in the metallic Te sheets through partial filling. Finite Pr 4 f spectral weight is observed near the Fermi level, suggesting the non-negligible Pr 4 f contribution to the CDW formation through the Pr 4 f -Te 5p hybridization. The two-fold symmetric features in the measured Fermi surface (FS) of PrTe 3 are explained by the calculated FS for the assumed 7 × 1 CDW supercell formation in Te sheets. The shadow bands and the corresponding very weak FSs are observed, which originate from both the band folding due to the 3D interaction of Te sheets with neighboring Pr-Te layers and that due to the CDW-induced FS reconstruction. The straight vertical FSs are observed along k z , demonstrating the nearly 2D character for the near-EF states. The observed linear dichroism reveals the in-plane orbital character of the near-E F Te 5p states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of a fully-fiber multi-chord interferometer and a new phase-shift demodulation method for field-reversed configuration

A 633 nm laser interferometer has been designed based on a novel concept, which, without the acousto-optic modulator or the demodulator circuit, adopts the fibers to connect all elements except photodetectors and oscilloscope in this system to make it more compact, portable, and efficient. The noteworthy feature is to mathematically compare the two divided interference signals, which have the same phase-shift caused by the electron density but possess the different initial phase and low angular frequencies. It is possible to read the plasma density directly on the oscilloscope by our original mathematic demodulation method without a camera. Based on the Abel inversion algorithm, the radial electron density profiles versus time can be obtained by using the multi-chord system. The designed measurable phase shift ranges from 0 to 2π rad corresponding to the maximum line integral of electron density less than 3.5 × 10{sup 17} cm{sup −2}, and the phase accuracy is about 0.017 rad corresponding to the line integral of electron density accuracy of 1 × 10{sup 15} cm{sup −2}. After the construction of eight-chord interferometer, it will provide the detailed time resolved information of the spatial distribution of the electron density in the field-reversed configuration (FRC) plasma target produced by the “Yingguang-1” programmed-discharge device, which is being constructed in the Key Laboratory of Pulsed Power, China Academy of Engineering Physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Spatially resolved measurements of ion density and electron temperature in a dual-frequency capacitively coupled plasma by complete floating double probe technique

Spatially resolved measurements of the ion density and electron temperature in a dual-frequency capacitively coupled Ar discharge plasma are performed with a newly developed complete floating double probe. Axial and radial distributions of the ion density and electron temperature under various high-frequency (HF) power and gas pressure were studied in detail. Both the ion density and the electron temperature increased with increasing HF power. With increasing gas pressure from 1.3 to 9.3 Pa, the radial profile of ion density below the driven electrode experienced a change from ''bimodal'' to ''unimodal'' shape, with better uniformity being achieved at the optimal pressure of about 5 Pa. In addition, changing the axial profile of ion density was also observed with the peak shift toward the powered electrode at higher pressures. The measured results showed satisfying consistency with that of improved two dimensional fluid simulations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Excitation of surface plasma waves by a density-modulated electron beam in a magnetized plasma cylinder

A density-modulated electron beam propagating through a plasma cylinder excites surface plasma waves (SPWs) via Cerenkov and fast cyclotron interaction. A nonlocal theory of this process has been developed. Numerical calculations of the growth rate and unstable mode frequencies have been carried out for the typical parameters of the SPWs. The growth rate {gamma} (in rad/s) of the unstable wave instability increases with the modulation index {Delta} and has the largest value for {Delta}{approx}1 in addition to when the frequency and wave number of the modulation are comparable to that of the unstable wave. For {Delta}=0, {gamma} turns out to be {approx}6.06x10{sup 9} rad/s for Cerenkov interaction and {approx}5.47x10{sup 9} rad/s for fast cyclotron interaction. The growth rate of the instability increases with the beam density and scales as one-third power of the beam density in Cerenkov interaction and is proportional to the square root of beam density in fast cyclotron interaction. The real part of the frequency of the unstable wave increases as almost the square root of the beam voltage. The results of the theory are applied to explain some of the experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Data Source for Studying and Modelling the Topside Ionosphere

The existing uncertainties about density profiles in the topside ionosphere, i.e., in the height regime from hmF2 to approx. 2000 km, requires the search for new data sources. Millions of ionograms had been recorded by the ISIS and Alouette satellites in the sixties and seventies, that never were analyzed in terms of electron density profiles. In recent years an effort started to digitize the analog recordings to prepare the ionograms for computerized analysis. This paper shows how the digital ionograms are processed and the electron density profiles (from satellite orbit altitude, 1400 km for ISIS-2, down to the F peak) are calculated. The most difficult part of the task is the automatic scaling of the echo traces in the ISIS ionograms. Unlike the ionograms from modern ionosondes, the ISIS ionograms do not identify the wave polarization of the different echo traces, so physical logic must be applied to identify the ordinary ()) and extraordinary (X) traces, and this is not always successful. Characteristic resonance features seen in the topside ionograms occur at the gyro and plasma frequencies. An elaborate scheme was developed to identify these resonance frequencies in order to determine the local plasma and gyrofrequencies. This information helps in the identification of the O and X traces, and it provides the starting density of the electron density profile. The inversion of the echo traces into electron density profiles uses the same modified Chebyshev polynomial fitting technique that is successfully applied in the ground-based Digisonde network. The automatic topside ionogram scaler with true height algorithm TOPIST is successfully scaling approx. 70% of the ionograms. An 'editing process' is available to manually scale the more difficult ionograms. The home page for the ISIS project is at http://nssdc.gsfc.nasa.gov/space/isis/isis-status.html. It provides access to as of January 2001, 3000,000 digitized ISIS ionogram data and to related software. A search page lets users select data location, time, and a host of other search criteria. The automated processing of the ISIS ionograms will begin later this year and the electron density profiles will be made available from the project home page. The ISIS data restoration efforts are supported through NASA's Applied Systems and Information Research Program.

Huang, Xue-Qin↗