Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric grid systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Extremum seeking control of distributed energy resources with decaying dither and equilibrium-based switching

Embodiments relate to an operating system coupled to and controlling at least one Distributed Energy Resource (DER) in a smart grid and includes an electricity distribution network and a 2-dimensional Extremum Seeking (2D-ES) controller coupled to network. The electricity distribution network has first and second inputs and one output and maps all active power and reactive power inputs to the smart grid providing measurements of an objective function. The 2D-ES controller controls the DER and includes an active power loop and a reactive power loop. The active power loop is in communication with the first input and the output, governs active power contribution, and receives measurements of the objective function which contain static and oscillatory components. The reactive power loop is in communication with the second input and the output, governs reactive power contribution, and receives measurements of the objective function which contain static and oscillatory components.

Arnold, Daniel↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Comparison of Stirling engines for use with a 25-kW disk-electric conversion system

Heat engines were evaluated for terrestrial solar heat receivers. The Stirling Engine was identified as one of the most promising engines for terrestrial applications. The potential to meet the Department of Energy (DOE) goals for performance and cost can be met by the free-piston Stirling engine. NASA Lewis is providing technical management for an Advanced Stirling Conversion System (ASCS) through a cooperative interagency agreement with DOE. Parallel contracts were awarded for conceptual designs of an ASCS. Each design will feature a free-piston Stirling engine, a liquid-metal heat pipe receiver, and a means to provide about 25 kW of electric power to a utility grid while meeting long-term performance and goals. The Mechanical Technology, Ins. (MTI) design incorporates a linear alternator to directly convert the solar energy to electricity while the Stirling Technology Company (STC) generates electrical power indirectly by using a hydraulic output to a ground-bases hydraulic pump/motor coupled to a rotating alternator. Both designs use technology which can reasonably be expected to be available in the 1980's. The ASCS designs using a free-piston Stirling engine, a heat transport system, a receiver, and the methods of providing electricity to the utility grid will be discussed.

Shaltens, Richard K.↗

Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays

This is the final technical report for the Virginia Tech Center for Photonics Technology (VT-CPT) research project entitled “Fully Distributed Acoustic and Magnetic Field Monitoring Via a Single Fiber Line for Optimized Production of Unconventional Resource Plays”. In the the four-year effort, VT-CPT collaborated with the Departments of Mathmatics at VT and Sentek Instrument, LLC (Sentek) to develop a fiber-optic sensing system capable of real-time simultaneous distributed measurement of multiple subsurface, drilling, and production parameters. The ultra-sensitive fiber optic distributed acoustic sensing technology, picoDAS, developed by Sentek was integrated with a novel multi-material optical sensing fiber fabricated by CPT-VT to obtain distributed acoustic and magnetic field measurements with ultrahigh sensitivity and high spatial resolution. The sensing technology successfully developed and demonstrated under this research program is truly unique has application beyond subsurface imaging to include carbon storage and electrical grid monitoring, as well as healthcare and nuclear fusion. The project, sponsored by the Advanced Technology Program, began in 2019 and had the original goal of developing the next generation of harsh environment sensing systems. Exhaustive theoretical modeling was performed to optimize the multi-material optical fiber design. VT developed the processing techniques employed to successfully fabricate single mode fibers with metal cladding wires. Sensing fibers with nickel and Metglas cladding wires were fully characterized, inscribed with sensors, and fully integrated with the picoDAS system. Laboratory scale testing was performed to demonstrate performance upon exposure to lateral and transverse magnetic fields. Preliminary field trials were performed for prototype magnetic and acoustic sensing systems upon near surface deployment at VT. The distributed acoustic and magnetic field sensing system was advanced from a (Technology Readiness Level) TRL=2 to a TRL=5 via laboratory scale system validation in relevant environments. The truly one-of-its kind distributed magnetic and acoustic sensing system is expected to find immediate applications that require subsurface monitoring, to include carbon storage site monitoring, and has the potential to be a distributive technology in healthcare and electric grid markets. The technologies developed by Virginia Tech’s Center for Photonics Technology will support the mission of the National Energy Technology Laboratory (NETL) to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future by ensuring affordable, abundant, and reliable energy that drives a robust economy and national security. Technical accomplishments during the program are summarized briefly here and described in detail in the remainder of the report.

02 PETROLEUM↗

Energy storage solutions to decarbonize electricity through enhanced capacity expansion modelling

To meet ambitious global decarbonization goals, electricity system planning and operations will change fundamentally. With increasing reliance on variable renewable energy resources, energy storage is likely to play a critical accompanying role to help balance generation and consumption patterns. As grid planners, non-profit organizations, non-governmental organizations, policy makers, regulators and other key stakeholders commonly use capacity expansion modelling to inform energy policy and investment decisions, it is crucial that these processes capture the value of energy storage in energy-system decarbonization. Here we conduct an extensive review of literature on the representation of energy storage in capacity expansion modelling. We identify challenges related to enhancing modelling capabilities to inform decarbonization policies and electricity system investments, and to improve societal outcomes throughout the clean energy transition. Additionally, we further identify corresponding research activities that can help overcome these challenges and conclude by highlighting tangible real-world outcomes that will result from pursuing these research activities. Capacity expansion modelling (CEM) approaches need to account for the value of energy storage in energy-system decarbonization. A new Review considers the representation of energy storage in the CEM literature and identifies approaches to overcome the challenges such approaches face when it comes to better informing policy and investment decisions.

25 ENERGY STORAGE↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Competitiveness Assessment of Decarbonizing Electricity and Process Heat Supply to a Campus with a Small Nuclear Reactor

This paper analyzes the competitiveness of siting a small nuclear reactor to support decarbonization of sites requiring tens of MW of electricity and/or process heat to support centralized heating and cooling system. This paper focuses on campuses as representative of sites with collections of buildings and research facilities with decarbonization needs represented by buildings heating, and electricity consumption by electrical loads which may include cooling via chilled water (e.g., for air conditioning and to cool down computer clusters). A nuclear reactor can be considered to decarbonize a site’s high-temperature steam generation used mostly for building heating needs, climate control, and hot water, by supplying process heat capabilities, while electricity decarbonization would be achieved mostly by the grid. However, a secondary application can be considered to maximize reactor utilization and avoid ramping down the reactor if the steam demand varies significantly throughout the year. Chilled water generation through steam-driven systems was identified as an attractive secondary option for the site analyzed, due to potential for plant design simplification, while electricity generation could be considered as well to reduce electricity purchases for a wider range of site applications. For a campus with peak 60MW thermal power demand, a small nuclear reactor with similar thermal power rating would almost eliminate CO2 emissions from steam generation and reduce electricity imports for chilled water production. A preliminary techno-economic feasibility study shows that a small nuclear reactor design that is optimized to support process heat can represent an economically feasible option when compared with other decarbonization alternatives.

Stauff, Nicolas E.↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

Satellite power system concept development and evaluation program. Volume 2: System definition

The system level results of the system definition studies performed by NASA as a part of the Department of Energy/NASA satellite power system concept development and evaluation program are summarized. System requirements and guidelines are discussed as well as the major elements that comprise the reference system and its design options. Alternative system approaches including different system sizes, solid state amplifier (microwave) concepts, and laser power transmission system cost summaries are reviewed. An overview of the system analysis and planning efforts is included. The overall study led to the conclusion that the reference satellite power system concept is a feasible baseload source of electrical power and, within the assumed guidelines, the minimum cost per kilowatt is achieved at the maximum output of 5 gigawatts to the utility grid. Major unresolved technical issues include maximum allowable microwave power density in the ionosphere and performance/mass characteristics of laser power transmission systems.

Source record↗

Evolution of solid electrolyte interphase and active material in the silicon wafer model system

Alloying anode materials for lithium-ion batteries, such as silicon (Si), are an important focus of materials research due to the demand for increased energy density for electric vehicles and stationary grid storage. However, progress towards next generation anode materials has been hindered by poor capacity retention due to the instability of the Si active material and the solid electrolyte interphase (SEI). Herein, the evolution of the active Si material and the SEI are simultaneously investigated from the perspective of chemical, structural, morphological, and electronic evolution in the Si wafer model system through its cycling life, using time-of-flight secondary ion mass spectrometry (TOF-SIMS), scanning transmission electron microscopy (STEM), atomic force microscopy (AFM), and scanning spreading resistance microscopy (SSRM). The results illustrate a dynamic evolution of the SEI and active Si material through cycling. Through an improved understanding of evolution of SEI and Si active material within the Si wafer model system, mitigation strategies may be designed to extend the lifetime of Si anodes.

25 ENERGY STORAGE↗

Impact assessment of geomagnetic induced current neutral blocking devices with power electronics sources on distance relay for 230 kV transmission lines

Electrical grids increased the integration of power electronics sources onto transmission lines. In addition, recent reports show a significant rise in geomagnetic storms occurring in 2024. These geomagnetic storms can affect transmission lines by inducing electrical currents within them, potentially causing power outages due to overloaded power transformers. Geomagnetic induced current neutral blocking devices (GIC-NBDs) are capacitors on the ground of wye power transformers, to avoid damage caused by geomagnetic storms. The integration of distance relays and transmission lines with power electronics sources and GIC-NBDs needs to be studied to observe if GIC-NBDs and power electronics sources could adversely affect operation of the electrical grid. In this analysis, the effect of 2 MW power electronics sources and GIC-NBDs on distance relays is assessed for different 230 kV transmission line lengths in radial and nonradial power systems. The simulations measured the apparent impedances, with different electrical faults. Results for a typical 2,650 μF GIC-NBD application were presented on impedance plots, and the distance relay model operations were assessed. In conclusion, the tests for radial and nonradial power systems showed the behavior of the distance elements and source impedance ratios, assessing the effect of power electronics sources and GIC-NBDs on 230 kV transmission lines.

Distance relays↗

Near-Term Electricity Requirement and Emission Implications for Sustainable Aviation Fuel Production with CO 2 -to-Fuels Technologies

Aviation contributed approximately 10% of the U.S. transportation sector's greenhouse gas (GHG) emissions and about 3% of the nation's total GHG production before the coronavirus disease (COVID-19) pandemic (EPA 2022). Unlike the ground transportation sector, which can be decarbonized by using batteries and hydrogen fuel cell powertrain technologies, the technical and economic challenges of aviation electrification open the opportunity for CO 2 utilization (CO2U) using clean power sources. The U.S. government set a goal to produce 3 billion gallons per year of sustainable aviation fuels (SAF) by 2030 and scale up the production to 35 billion gallons per year by 2050 (Bioenergy Technologies Office 2022). In this report, we examine three potential locations, in California, Iowa, and Louisiana, for SAF production using two production pathways that are expected to be available by 2030. We analyze the electricity cost to satisfy 10% of the SAF production potential for the select locations. Specifically, we consider (1) retail electricity cost from the default local utility in each location; (2) physical power purchase agreement (PPA) for renewable power and battery storage hybrid systems with preset prices; (3) financial PPA from a dedicated renewable plant; and (4) estimated real-time pricing (RTP) from the wholesale power market with utility delivery adders. Retail rates are available for the three potential locations; however, the developer should negotiate with the local utility in Iowa for new tariff riders, because the load of the proposed SAF plant (1.4 GW) is significantly higher than the current industrial tariff structure requirement (200 kW). The developers are not able to claim federal credits (i.e., the Inflation Reduction Act of 2022) when sourcing electricity from local utilities. Developers could consider prioritizing physical and financial PPAs as purchase options. While physical PPAs can be imported out of state, this structure imposes availability issues as developers must locate in the same electricity grid regions. Financial PPAs do not have the same location restrictions and provide the same cost savings as physical PPAs, but financial PPAs impose financial risks in the event of system curtailment and grid interruption. RTPs are available for customers in California with flexible load and hourly load management capability; however, utilities in our studied regions in Louisiana and Iowa only offer time-of-use and curtailment programs to incentivize lower energy usage in peak hours. These utilities do not currently offer RTP programs, and the developer may need to have further negotiations with the local utilities to access RTP programs. The results show that purchased electricity prices may range from 2.6 cents/kWh to 7.1 cents/kWh for the three studied plants.

02 PETROLEUM↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acquire and Test IDAES Framework Components

The cooperation under the Grid Modernization Initiative and the Applied Energy Tri-Laboratory umbrellas requires mutual understanding of capabilities and a common effort to identify gaps existing in the available computational modeling and analysis tools. In this work, we report acquisition and testing of the National Energy Technology Laboratory’s Institute for the Design of Advanced Energy Systems (IDAES) framework, particularly including both electric power systems production cost model simulator Prescient as well as system optimization IDAES itself. Further, we consider the methods in which developments in Prescient and IDAES for grid-energy simulation and optimization may be included in the Framework for Optimization of ResourCes and Economics (FORCE) ecosystem that has been under collaborative development by Idaho National Laboratory, Argonne National Laboratory, and Oak Ridge National Laboratory. We propose two integration methods to introduce Prescient and IDAES into existing FORCE automated workflows. One integration involves using Prescient as a market reduced-order model and IDAES models similar to how existing Modelica models are used. The other integration involves wrapping the Prescient-IDAES dispatch optimization process with the stochastic capacity optimization workflow in FORCE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inventory of Public Key Cryptography in US Electric Vehicle Charging

Electric vehicles (EVs) and charging infrastructure are networked systems, which employ high-level communications in support of charging and grid service decisions. Public key cryptography (PKC) underlies much of the security and privacy protections of the information exchange. We are entering a new epoch where quantum computing threats must be seriously considered. A sufficiently large quantum computer, so named Cryptographically Relevant Quantum Computer (QRQC), will be able to perform the mathematical operations to efficiently attack the underpinnings of traditional PKC, thus jeopardizing the digital foundations for trust, communications security, and data security. Estimates suggest a QRQC can break public key encryption and digital signatures in the manner of tens to hundreds of hours, compared to traditional computing that would demand more than 10 18 years in a brute force-style attack. A consensus belief of quantum theorists, quantum experimenters, and cryptographers suggest that the quantum threat will be likely realized in the next twenty years. To address the threat, post-quantum cryptography, which is cryptosystems that are designed to be secure against both traditional and quantum computing threats, must be adopted. Migration from traditional PKC to quantum-resilient cryptography is a global undertaking and likely represents the largest transition in computing history. The nascent state of EV public key infrastructure, combined with limited adoption of the vehicle secure charging features, presents an opportunity to establish a preference for quantum-resistant cryptography as a step on the migration path. Delays will stunt the efforts as rapidly accelerating EVs sales and huge infrastructure investments will create large growing bases of long-lived vehicles and infrastructure. Migration preparations can commence while NIST continues the process to standardize post-quantum cryptography (PQC), which are quantum-resilient algorithms designed to be secure against traditional and quantum computing threats. The first step in preparing EV charging is to identify the presence of traditional public key cryptography algorithms and applications. With this objective in mind, this report is intended to advise the vehicle manufacturers, charging station manufacturers, charging station operators, charge network providers and other EV charging stakeholders with information on traditional PKC application and the potential risks when PKC becomes insecure. This report, the first in a series of reports discussing the topics existing at the confluence of post-quantum cryptography adoption and EV charging, identifies traditional public key applications employed and identifies potential consequences of leaving EV charging infrastructure vulnerable to quantum computing. The focus remains squarely on the of EV charging and infrastructure with respect to PKC and is believed by the authors to complement the NIST SP 1800-38 Migration to Post-Quantum Cryptography. While the report is centered on infrastructure, there are implications to vehicles.

33 ADVANCED PROPULSION SYSTEMS↗

Design, fabrication, and operation of dished accelerator grids on a 30-cm ion thruster

Several closely-space dished accelerator grid systems were fabricated and tested on a 30-cm diameter mercury bombardment thruster and they appear to be a solution to the stringent requirements imposed by the near-term, high-thrust, low specific impulse electric propulsion missions. The grids were simultaneously hydroformed and then simultaneously stress relieved. The ion extraction capability and discharge chamber performance were studied as the total accelerating voltage, the ratio of net-to-total voltage, grid spacing, and dish direction were varied.

Rawlin, V. K.↗

Distributed Accounting on the Grid

By the late 1990s, the Internet was adequately equipped to move vast amounts of data between HPC (High Performance Computing) systems, and efforts were initiated to link together the national infrastructure of high performance computational and data storage resources together into a general computational utility 'grid', analogous to the national electrical power grid infrastructure. The purpose of the Computational grid is to provide dependable, consistent, pervasive, and inexpensive access to computational resources for the computing community in the form of a computing utility. This paper presents a fully distributed view of Grid usage accounting and a methodology for allocating Grid computational resources for use on a Grid computing system.

Thigpen, William↗