Effect of cathode diameter on intense relativistic electron beam generation in the presence of prepulse

Intense gigawatt relativistic electron beam generation studies were carried out in the presence of prepulse. Electron beams were generated using planar and annular graphite cathodes of various diameters at a fixed 25 mm anode-cathode gap. For the planar cathode, the beam parameters obtained are 340 keV, 24 kA, and 100 ns at a 680 A/cm{sup 2} current density. With an annular cathode, 346 keV, 10 kA, and 100 ns electron beam could be generated at a 3.4 kA/cm{sup 2} current density. The peak electric field in the diode varies from 58 to 138 kV/cm. A bipolar prepulse voltage has been recorded at the diode for both the cathodes. The amplitude of the negative prepulse voltage varies with the Marx generator voltage but the time duration remains same. The positive prepulse voltage varies both in amplitude and time duration with the Marx generator voltage. Some shot to shot variation in the diode voltage and current were recorded for the annular cathode due to the nonreproducibility of the prepulse generated plasma. It was found that the effect of prepulse is more pronounced in the cathode of larger diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A synthetic diamond diode in volumetric modulated arc therapy dosimetry

Purpose: The aim of this work is to investigate the behavior of a single crystal diamond diode (SCDD) for volumetric modulated arc therapy (VMAT) dose verifications. This delivery technique is one of the most severe test of a dosimeter performance due to the modulation of the dose rate achieved by simultaneously changing the velocity of the gantry and the position of the collimator leaves. The performed measurements with VMAT photon beams can therefore contribute to an overall global validation of the device to be used in dose distribution verifications.Methods: The SCDD response to 6 MVRX has been tested and compared with reference ionization chambers and treatment planning system (TPS) calculations in different experiments: (a) measurements of output factors for small field sizes (square fields of side ranging between 8 mm and 104 mm) by SCDD and A1SL ionization chamber; (b) angular dependence evaluation of the entire experimental set-up by SCDD, A1SL, and Farmer ionization chambers; and (c) acquisition of dose profiles for a VMAT treatment of a pulmonary disease in latero-lateral and gantry-target directions by SCDD and A1SL ionization chamber.Results: The output factors measured by SCDD favorably compare with the ones obtained by A1SL, whose response is affected by the lack of charged particle equilibrium and by averaging effect when small fields are involved. From the experiment on angular dependence, a good agreement is observed among the diamond diode, the ion chambers, and the TPS. In VMAT profiles, the absorbed doses measured by SCDD and A1SL compare well with the TPS calculated ones. An overall better agreement is observed in the case of the diamond dosimeter, which is also showing a better accuracy in terms of distance to agreement in the high gradient regions.Conclusions: Synthetic diamond diodes, whose performance were previously studied for conformal and IMRT radiotherapy techniques, were found to be suitable detectors also for dosimetric measurements in volumetric arc therapy treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantum Efficiency Gain in 2D Perovskite Photo and X‐Ray Detectors

Abstract The perovskite polycrystalline thin film detector fabricated by solution method is a promising low‐cost, scalable technology for radiation imaging, but its thin volume limits the sensing efficiency for high‐energy X‐ray photons. This work reports 2D perovskite thin film photo‐diodes with a detection gain when sensing visible and X‐ray photons. Detailed power and temperature‐dependent device characterizations reveal a charge multiplication effect to be responsible for the observed high gain. This is caused by a disparity in electron and hole transport, where electron transport is retarded by a trap/de‐trap process via shallow trap states, whereas the hole transport is fast enough to produce a photoconductive gain in satisfying the charge neutrality. The 2D perovskite made with butylamine spacers is also found to exhibit a larger efficiency gain than those made with phenylethylamines because of the higher likelihood of forming shallow traps in the former. The thin film diodes feature a high temporal response over 1 MHz due to the fast charge collection across a thin volume, and the discovery provides device physics mechanisms in connection to material structure‐function relationship for future optoelectronics design that can boost the efficiency of X‐ray sensing and dim light detection.

2D perovskites↗

Optimization of Diode Laser System to Treat Benign Prostate Hyperplasia Final Report CRADA No. TSB-1154-95

Benign prostate hyperplasia (BPH) is a pervasive condition of enlargement of the male prostate gland which leads to several urinary difficulties ranging from hesitancy to incontinence to kidney dysfunction in severe cases. Currently the most common therapy is transurethral resection of the prostate (TURP) utilizing an electrosurgical device. Although TURP is largely successful, new BPH therapy methods are desired to reduce the cost and recovery time, improve the success rate, and reduce side effects. Recently, lasers have been introduced for this purpose. Indigo Medical Inc. is currently engaged in the development, testing, and preparation for sales of a new diode laser based BPH therapy system. The development is based on laboratory experiments, animal studies, and a limited FDA-approved clinical trial in the US and in other countries. The addition of sophisticated numerical modeling, of the sort that has been highly developed at Lawrence Livermore National Laboratory, can greatly aid in the design of the system and treatment protocol. The benefits to DOE include the maintenance and advancement of numerical modeling expertise in radiation-matter interactions of the sort essential for the stockpile stewardship, inertial confinement fusion, and advanced manufacturing, and the push on advanced scientific computational methods, ultimately in areas such as 3-D transport.

42 ENGINEERING↗

Vertical-cavity in-plane heterostructures: Physics and applications

We show that in-plane (lateral) heterostructures realized in vertical cavities with high contrast grating reflectors can be used to significantly modify the anisotropic dispersion curvature, also interpreted as the photon effective mass. This design freedom enables exotic configurations of heterostructures and many interesting applications. The effects of the anisotropic photon effective mass on the mode confinement, mode spacing, and transverse modes are investigated. As a possible application, the method of boosting the speed of diode lasers by engineering the photon-photon resonance is discussed. Based on this platform, we propose a system of two laterally coupled cavities, which shows the breaking of parity-time symmetry in vertical cavity structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of growth temperature on ballistic electron transport through the Au/Si(001) interface

Ballistic electron emission spectroscopy was used to investigate electron transport through Au/Si(001) Schottky diodes grown at 35 °C and 22 °C. Aside from a decreased Schottky height, this small increase in temperature introduced an energy dependent scattering component, which was absent in the samples grown at 22 °C. These differences may be attributed to the increased amount of Au-Si intermixing at the interface. Despite the non-epitaxial nature of the growth technique, strong evidence was found in both sets of samples that indicated the presence of a forward-focused current subject to some degree of parallel momentum conservation at the interface. This evidence was present in all samples grown at 35 °C, but was only observed in those samples grown at 22 °C when the Au films were 10 nm or thicker. This sensitivity to growth temperature could account for discrepancies in previous studies on Au/Si(001)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of pump geometry on the generation efficiency of an alkali metal vapour laser

The influence of pump geometry on the generation efficiency of a transversely diode-pumped alkali metal vapour laser is studied theoretically. Analytical formulas describing the operation of a high-intensity laser with double-sided diode pumping in two orthogonal directions are obtained. It is shown that the generation efficiency of an alkali metal vapour laser can be increased by 8% – 18% when switching from single-sided to double-sided pumping. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The impact of defects on the photovoltaic potential of RTR silicon ribbon

Silicon ribbon grown at a high rate by the ribbon-to-ribbon (RTR) method contains a variety of defects and can exhibit an unusual dendritic morphology. This paper is a study of the effect of the defect structure and dendritic morphology on the photovoltaic potential of RTR ribbon. Defects found in RTR ribbon include grain boundaries, twin planes, stacking faults and dislocations. The electrical activity of these defects is investigated by measuring the diffusion length in the ribbon; by fabricating small area diodes on the ribbon and evaluating their photoresponse; and by using a scanning electron microscope in the electron beam induced current mode. It is concluded that although grain boundaries serve very effectively as recombination centers, they do not occur frequently enough in RTR ribbons to significantly affect the generation current. Dislocation densities up to 1,000,000/sq cm can be tolerated without strongly reducing the photoresponse. Similarly, linear boundaries such as twin planes or stacking faults do not affect the cell performance up to densities of 1000/sq cm.

Baghdadi, A.↗

Optical Signatures of Transiently Disordered Semiconductor Nanocrystals

The remarkable optoelectronic properties of semiconductor nanocrystals (NCs) have led to efforts to integrate them as the active material in light-emitting diodes, solid-state-lighting, and lasers. Understanding related high carrier injection conditions is therefore critical as resultant thermal effects can impact optical properties. The physical integrity of the NC is indeed questionable as recent transient X-ray diffraction studies have suggested that NCs reversibly lose crystalline order, or melt, under high fluence photoexcitation. Informed by such studies, here, we examine CdSe NCs under elevated fluences to determine the impact of disordering on optical properties. To this end, we implement intensity-dependent transient absorption using both one- and two-pump methods where the latter effectively subtracts out the NC optical signatures associated with lower fluence photoexcitation, especially band-edge features. At elevated fluences, we observe a long-lived induced absorption to the red of the bandgap across a wide range of sizes that follows power dependent trends and kinetics consistent with the prior transient X-ray measurements. NC photoluminescence studies provide further evidence that melting influences optical properties. These methods of characterizing bandgap narrowing caused by NC disordering could facilitate improved optical amplification and band-edge emission at high excitation density.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Resistance transition assisted geometry enhanced magnetoresistance in semiconductors

Magnetoresistance (MR) reported in some non-magnetic semiconductors (particularly silicon) has triggered considerable interest owing to the large magnitude of the effect. Here, we showed that MR in lightly doped n-Si can be significantly enhanced by introducing two diodes and proper design of the carrier path [Wan, Nature 477, 304 (2011)]. We designed a geometrical enhanced magnetoresistance (GEMR) device whose room-temperature MR ratio reaching 30% at 0.065 T and 20 000% at 1.2 T, respectively, approaching the performance of commercial MR devices. The mechanism of this GEMR is: the diodes help to define a high resistive state (HRS) and a low resistive state (LRS) in device by their openness and closeness, respectively. The ratio of apparent resistance between HRS and LRS is determined by geometry of silicon wafer and electrodes. Magnetic field could induce a transition from LRS to HRS by reshaping potential and current distribution among silicon wafer, resulting in a giant enhancement of intrinsic MR. We expect that this GEMR could be also realized in other semiconductors. The combination of high sensitivity to low magnetic fields and large high-field response should make this device concept attractive to the magnetic field sensing industry. Moreover, because this MR device is based on a conventional silicon/semiconductor platform, it should be possible to integrate this MR device with existing silicon/semiconductor devices and so aid the development of silicon/semiconductor-based magnetoelectronics. Also combining MR devices and semiconducting devices in a single Si/semiconductor chip may lead to some novel devices with hybrid function, such as electric-magnetic-photonic properties. Our work demonstrates that the charge property of semiconductor can be used in the magnetic sensing industry, where the spin properties of magnetic materials play a role traditionally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topological insulator-metal transition and molecular electronics device based on zigzag phagraphene nanoribbon

Here, we explore the electronic transport properties of a graphene allotrope composed of 5–6-7 carbon aromatic rings called phagraphene and compare with the results of the transition-voltage spectroscopy (TVS) and propose the behavior at low voltage characteristic of a topological insulator. Phagraphene properties were compared to those of graphene in a zigzag nanoribbon configuration, zigzag graphene vs zigzag phagraphene nanoribbon (zzGNR and zzPGNR). The molecular geometry and the electronic properties were calculated by density functional theory (DFT) without spin, and the electronic transport and TVS were obtained by means of DFT combined with non-equilibrium Green´s function when we couple the optimized geometry of zzGNR and zzPGNR to the leads (left and right), forming the molecular junction that will be subjected to the action of an external bias voltage (V e ) to generate the molecular device. The findings exhibit (i) a metal-insulator transition when V e is increased until V e = 1.4 V which corresponds to the nonlinear region (resonance), showing the field effect transistor behaviour for zzGNR junctions; and (ii) two nonlinear regions (two negative differential resistances), showing a resonant tunnel diode behaviour with two operation windows (V e = 0.5 V and V e = 1.7 V) for the zzPGNR junction. In addition, the zzPGNR junction exhibits topological insulator characteristics upon introducing topological defects such as pentagons and heptagons in the hexagonal lattice of graphene, and when V e = 1.7 V, there occurs a topological insulator-metal transition that can be seen in the behaviour of the density of states, transmittance, and frontier molecular orbitals with V e .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative analysis of leakage current in III-nitride micro-light-emitting diodes

In this study, the electrical characteristics under forward- and reverse-bias conditions of III-nitride blue and green micro-light-emitting diodes (μLEDs) are analyzed. A fitting model is proposed to determine the contributions of reverse leakage current and the effectiveness of sidewall treatments. Moreover, the forward-bias currents of the μLEDs are examined using the extracted ideality factor to examine the impacts of sidewall defects. The results show that sidewall treatments are highly effective for suppression of leakage currents. From the efficiency perspective, higher wall-plug efficiency (WPE) than external quantum efficiency (EQE) is observed when the operating voltage is lower than the photon voltage in both blue and green 20 × 20 μm 2 devices. This enhancement of the WPE over the EQE is due to the suppression of Shockley–Read–Hall (SRH) nonradiative recombination. These observations indicate that μLEDs with sidewall treatments not only improve optical performance but also further enhance the electrical performance of devices by suppressing the leakage current paths due to SRH nonradiative recombination processes.

42 ENGINEERING↗

Fully Polarimetric Differential Intensity W-band Imager

We present a novel architecture based upon a Dicke-switched heterodyne radiometer architecture employing two identical input sections consisting of horn and orthomode transducer to detect the difference between the H and V polarization states of two separate object patches imaged by the radiometer. We have constructed and described previously a fully polarimetric W-band passive millimeter wave imager constructed to study the phenomenology of anomaly detection using polarimetric image exploitation of the Stokes images. The heterodyne radiometer used a PIN diode switch between the input millimeter wave energy and that of a reference load in order to eliminate the effects of component drifts and reduce the effects of 1/f noise. The differential approach differs from our previous work by comparing H and V polarization states detected by each of the two input horns instead of a reference load to form signals delta H and delta V from closely adjacent paired object patches. This novel imaging approach reduces common mode noise and enhances detection of small changes between the H and V polarization states of two object patches, now given as difference terms of the fully polarimetric radiometer. We present the theory of operation, initial proof of concept experimental results, and extension of the differential radiometer to a system with a binocular fore optics that allow adjustment of the convergence or shear of the object patches viewed by the differential polarimetric imager.

Differential Millimeter Wave Imager↗

SU-F-T-367: Using PRIMO, a PENELOPE-Based Software, to Improve the Small Field Dosimetry of Linear Accelerators

Purpose: To calculate output correction factors for Varian Clinac 2100iX beams for seven small field detectors and use the values to determine the small field output factors for the linacs at Karolinska university hospital. Methods: Phase space files (psf) for square fields between 0.25cm and 10cm were calculated using the PENELOPE-based PRIMO software. The linac MC-model was tuned by comparing PRIMO-estimated and experimentally determined depth doses and lateral dose-profiles for 40cmx40cm fields. The calculated psf were used as radiation sources to calculate the correction factors of IBA and PTW detectors with the code penEasy/PENELOPE. Results: The optimal tuning parameters of the MClinac model in PRIMO were 5.4 MeV incident electron energy and zero energy spread, focal spot size and beam divergence. Correction factors obtained for the liquid ion chamber (PTW-T31018) are within 1% down to 0.5 cm fields. For unshielded diodes (IBA-EFD, IBA-SFD, PTW-T60017 and PTW-T60018) the corrections are up to 2% at intermediate fields (>1cm side), becoming down to −11% for fields smaller than 1cm. The shielded diode (IBA-PFD and PTW-T60016) corrections vary with field size from 0 to −4%. Volume averaging effects are found for most detectors in the presence of 0.25cm fields. Conclusion: Good agreement was found between correction factors based on PRIMO-generated psf and those from other publications. The calculated factors will be implemented in output factor measurements (using several detectors) in the clinic. PRIMO is a userfriendly general code capable of generating small field psf and can be used without having to code own linac geometries. It can therefore be used to improve the clinical dosimetry, especially in the commissioning of linear accelerators. Important dosimetry data, such as dose-profiles and output factors can be determined more accurately for a specific machine, geometry and setup by using PRIMO and having a MC-model of the detector used.

43 PARTICLE ACCELERATORS↗

Origin of discrepancies in the experimental values of the barrier height at metal–semiconductor junctions

A possible explanation is suggested for discrepancies between experimental values obtained by different authors for the barrier height at the same metal–semiconductor junction. It is supposed that the problem is caused primarily by the structural inhomogeneity of the metal. As a result, the junction behaves as an assembly of a large number of subjunctions connected in parallel. To determine the effect of metal inhomogeneity on the properties of a junction, the dependence of the barrier height in a Schottky diode on the junction area is investigated under the assumption that, with an increase in the area of a junction between a singlecrystal semiconductor and a polycrystalline metal, the degree of inhomogeneity and, thus, the number of subjunctions, increases.

36 MATERIALS SCIENCE↗

Combined TDLAS and chemiluminescence imaging in a flat flame burner operated with NH3/H2 blends

Ammonia is viewed as a viable hydrogen carrier due to favorable storage and transport characteristics. While it can be re-converted to hydrogen at point-of-use via thermal catalytic cracking, direct utilization in combustion systems can result in reduced costs and improved efficiency. A major barrier to this approach is the low flammability and potential for high nitrogen oxide emissions, driven by fuel-bound nitrogen and complex kinetic pathways. While a number of kinetic mechanisms currently exist for simulating ammonia combustion, a major need continues to be direct information about species profiles in easy-to-model systems capable of isolating chemical kinetics from multi-dimensional fluid dynamic effects. This paper reports on recent species measurements made in a flat flame burner using a combined tunable-diode-laser-absorption-spectroscopy (TDLAS) and chemiluminescence imaging approach. Three flame conditions were included representative of NH3/H2 blends, partially cracked NH3 (inc. N2), and 100% NH3 with enhanced air (30% oxygen). Two NIR distributed feedback (DFB) laser diodes were used to determine H2O concentration and temperature (via ratio thermometry) at various radial and axial positions, after which an inverse Abel transform was used to infer centerline values. Companion images were collected using a Princeton Instrument PI-MAX intensified camera equipped with a 105mm UV lens and multiple filter sets targeting OH*, NH*, and NH2* emission. Results were compared to companion Cantera burner-stabilized flame simulations using various kinetic mechanisms. A recent mechanism including excited species chemistry was also included, to investigate whether excited and ground state profiles exhibit significant differences.

ammonia combustion↗

Semiconductor-ferroelectric nonvolatile memory using anomalous high photovoltages in ferroelectric ceramics

A small ferroelectric ceramic element is used with an insulating gate transistor and two diodes as an electrically addressed, nonvolatile memory device which is read out nondestructively. The device uses the anomalous photovoltaic effect in ferroelectric ceramics, an effect in which the polarity and magnitude of photovoltages depend on the direction and magnitude of remanent polarization. Experimental results give memory characteristics. The device could be programmed with pulses as short as 200 ns. There is long-time retention of stored data.

Brody, P. S.↗

Development of silicon carbide semiconductor devices for high temperature applications

The semiconducting properties of electronic grade silicon carbide crystals, such as wide energy bandgap, make it particularly attractive for high temperature applications. Applications for high temperature electronic devices include instrumentation for engines under development, engine control and condition monitoring systems, and power conditioning and control systems for space platforms and satellites. Discrete prototype SiC devices were fabricated and tested at elevated temperatures. Grown p-n junction diodes demonstrated very good rectification characteristics at 870 K. A depletion-mode metal-oxide-semiconductor field-effect transistor was also successfully fabricated and tested at 770 K. While optimization of SiC fabrication processes remain, it is believed that SiC is an enabling high temperature electronic technology.

Matus, Lawrence G.↗