Three-terminal ferroelectric synapse device with concurrent learning function for artificial neural networks

Spike-timing-dependent synaptic plasticity (STDP) is demonstrated in a synapse device based on a ferroelectric-gate field-effect transistor (FeFET). STDP is a key of the learning functions observed in human brains, where the synaptic weight changes only depending on the spike timing of the pre- and post-neurons. The FeFET is composed of the stacked oxide materials with ZnO/Pr(Zr,Ti)O{sub 3} (PZT)/SrRuO{sub 3}. In the FeFET, the channel conductance can be altered depending on the density of electrons induced by the polarization of PZT film, which can be controlled by applying the gate voltage in a non-volatile manner. Applying a pulse gate voltage enables the multi-valued modulation of the conductance, which is expected to be caused by a change in PZT polarization. This variation depends on the height and the duration of the pulse gate voltage. Utilizing these characteristics, symmetric and asymmetric STDP learning functions are successfully implemented in the FeFET-based synapse device by applying the non-linear pulse gate voltage generated from a set of two pulses in a sampling circuit, in which the two pulses correspond to the spikes from the pre- and post-neurons. The three-terminal structure of the synapse device enables the concurrent learning, in which the weight update can be performed without canceling signal transmission among neurons, while the neural networks using the previously reported two-terminal synapse devices need to stop signal transmission for learning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photo-fusion reactions in a new compact device for ELI

In the last few years significant progress on technological, experimental and numerical studies on fusion process in high density and high temperature plasmas produced by a high intensity laser pulse interaction with clusters in a high external applied magnetic field, enable us to propose a compact photo-fusion magnetic device for high neutron production. For the purpose of the project a pulsed magnetic field driver with values up to 110 Tesla has been developed which allows increasing the trapping time of the high density plasma in the device and improving the neutron yield. Numerical simulations show that the proposed device is capable of producing up to 10{sup 9}-10{sup 10} neutrons per laser shot with an external magnetic field of 150 Tesla. The proposed device can be used for experiments and numerical code validation concerning different conventional and (or) exotic fusion fuels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantum-ring spin interference device tuned by quantum point contacts

We introduce a spin-interference device that comprises a quantum ring (QR) with three embedded quantum point contacts (QPCs) and study theoretically its spin transport properties in the presence of Rashba spin-orbit interaction. Two of the QPCs conform the lead-to-ring junctions while a third one is placed symmetrically in the upper arm of the QR. Using an appropriate scattering model for the QPCs and the S-matrix scattering approach, we analyze the role of the QPCs on the Aharonov-Bohm (AB) and Aharonov-Casher (AC) conductance oscillations of the QR-device. Exact formulas are obtained for the spin-resolved conductances of the QR-device as a function of the confinement of the QPCs and the AB/AC phases. Conditions for the appearance of resonances and anti-resonances in the spin-conductance are derived and discussed. We predict very distinctive variations of the QR-conductance oscillations not seen in previous QR proposals. In particular, we find that the interference pattern in the QR can be manipulated to a large extend by varying electrically the lead-to-ring topological parameters. The latter can be used to modulate the AB and AC phases by applying gate voltage only. We have shown also that the conductance oscillations exhibits a crossover to well-defined resonances as the lateral QPC confinement strength is increased, mapping the eigenenergies of the QR. In addition, unique features of the conductance arise by varying the aperture of the upper-arm QPC and the Rashba spin-orbit coupling. Our results may be of relevance for promising spin-orbitronics devices based on quantum interference mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron transfer at the contact between Al electrode and gold nanoparticles of polymer: Nanoparticle resistive switching devices studied by alternating current impedance spectroscopy

Electron transfer at the contact between an Al electrode and Au nanoparticles of polymer:nanoparticle devices is studied by ac impedance spectroscopy. The devices have a polystyrene layer embedded with Au nanoparticles capped with conjugated 2-naphthalenethiol sandwiched between Al and MoO{sub 3}/Al electrodes, and they exhibit electrode-sensitive resistive switches. The devices in the pristine or high resistance state have high capacitance. The capacitance decreases after the devices switch to a low resistance state by a voltage scan. The change in the capacitance is attributed to the voltage-induced change on the electronic structure of the contact between the Al electrode and Au nanoparticles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic configuration dependence of magnetoresistance in a Fe-porphyrin-like carbon nanotube spintronic device

By using nonequilibrium Green's functions in combination with the density functional theory, we investigate the spin-dependent transport properties in a Fe-porphyrin-like carbon nanotube spintronic device. The results show that magnetoresistance ratio is strongly dependent on the magnetic configuration of the Fe-porphyrin-like carbon nanotube. Under the application of the external magnetic field, the magnetoresistance ratio of the device can be increased from about 19% to about 1020% by tuning the magnetic configuration in the device. Our results confirm that the magnetic configuration is a key factor for obtaining a high-performance spintronic device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calcium chloride electron injection/extraction layers in organic electronic devices

Nontoxic calcium chloride (CaCl{sub 2}) was introduced into organic electronic devices as cathode buffer layer (CBL). The turn-on voltage and maximum luminance of organic light-emitting diode (OLED) with 1.5 nm CaCl{sub 2} was 3.5 V and 21 960 cd/m{sup 2}, respectively. OLED with 1.5 nm CaCl{sub 2} possessed comparable electroluminescent characteristics to that of the commonly used LiF. Moreover, the performance of the organic photovoltaic device with 0.5 nm CaCl{sub 2} was comparable to that of the control device with LiF. Therefore, CaCl{sub 2} has the potential to be used as the CBL for organic electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An unattended device for high-voltage sampling and passive measurement of thoron decay products

An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

54 ENVIRONMENTAL SCIENCES↗

High-frequency programmable acoustic wave device realized through ferroelectric domain engineering

Surface acoustic wave devices are extensively used in contemporary wireless communication devices. We used atomic force microscopy to form periodic macroscopic ferroelectric domains in sol-gel deposited lead zirconate titanate, where each ferroelectric domain is composed of many crystallites, each of which contains many microscopic ferroelastic domains. We examined the electro-acoustic characteristics of the apparatus and found a resonator behavior similar to that of an equivalent surface or bulk acoustic wave device. We show that the operational frequency of the device can be tailored by altering the periodicity of the engineered domains and demonstrate high-frequency filter behavior (>8 GHz), allowing low-cost programmable high-frequency resonators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detection of nucleic acids by graphene-based devices: A first-principles study

Based on first-principles quantum transport calculations, we design a graphene-based biosensor device, which is composed of graphene nanoribbons electrodes and a biomolecule. It is found that when different nucleobases or poly nucleobase chains are located in the nanogap, the device presents completely different transport properties, showing different current informations. And the change of currents from 2 to 5 orders of magnitude for four different nucleobases suggests a great ability of discrimination by utilizing such a device. The physical mechanism of this phenomenon originates from their different chemical composition and structure. Moreover, we also explore the coupling effect of several neighboring bases and the size effect of the nanogap on transport properties. Our results show the possibility of rapid sequencing DNA by measuring such a transverse-current of the device, and provide a new idea for sequencing DNA.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bendable ZnO thin film surface acoustic wave devices on polyethylene terephthalate substrate

Bendable surface acoustic wave (SAW) devices were fabricated using high quality c-axis orientation ZnO films deposited on flexible polyethylene terephthalate substrates at 120 °C. Dual resonance modes, namely, the zero order pseudo asymmetric (A{sub 0}) and symmetric (S{sub 0}) Lamb wave modes, have been obtained from the SAW devices. The SAW devices perform well even after repeated flexion up to 2500 με for 100 times, demonstrating its suitability for flexible electronics application. The SAW devices are also highly sensitive to compressive and tensile strains, exhibiting excellent anti-strain deterioration property, thus, they are particularly suitable for sensing large strains.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High precision two-dimensional strain mapping in semiconductor devices using nanobeam electron diffraction in the transmission electron microscope

A classical method used to characterize the strain in modern semiconductor devices is nanobeam diffraction (NBD) in the transmission electron microscope. One challenge for this method lies in the fact that the smaller the beam becomes, the more difficult it becomes to analyze the resulting diffraction spot pattern. We show that a carefully designed fitting algorithm enables us to reduce the sampling area for the diffraction patterns on the camera chip dramatically (∼1/16) compared to traditional settings without significant loss of precision. The resulting lower magnification of the spot pattern permits the presence of an annular dark field detector, which in turn makes the recording of images for drift correction during NBD acquisition possible. Thus, the reduced sampling size allows acquisition of drift corrected NBD 2D strain maps of up to 3000 pixels while maintaining a precision of better than 0.07%. As an example, we show NBD strain maps of a modern field effect transistor (FET) device. A special filtering feature used in the analysis makes it is possible to measure strain in silicon devices even in the presence of other crystalline materials covering the probed area, which is important for the characterization of the next generation of devices (Fin-FETs).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrochemical model of the polyaniline based organic memristive device

The electrochemical organic memristive device with polyaniline active layer is a stand-alone device designed and realized for reproduction of some synapse properties in the innovative electronic circuits, including the neuromorphic networks capable for learning. In this work, a new theoretical model of the polyaniline memristive is presented. The developed model of organic memristive functioning was based on the detailed consideration of possible electrochemical processes occuring in the active zone of this device. Results of the calculation have demonstrated not only the qualitative explanation of the characteristics observed in the experiment but also the quantitative similarities of the resultant current values. It is shown how the memristive could behave at zero potential difference relative to the reference electrode. This improved model can establish a basis for the design and prediction of properties of more complicated circuits and systems (including stochastic ones) based on the organic memristive devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of annealing on graphene incorporated poly-(3-hexylthiophene):CuInS{sub 2} photovoltaic device

The effect of thermal annealing on the power conversion efficiency (PCE) of poly(3-hexylthiophene) (P3HT):CuInS{sub 2} quantum dot:graphene photovoltaic device has been studied by analyzing optical characteristics of composite films and electrical characteristics of the device with structure indium tin oxide/poly[ethylene dioxythiophene]:poly[styrene sulfonate] (ITO/PEDOT:PSS)/P3HT:CIS:graphene/LiF/aluminum. It was observed that after annealing at 120°C for 15 min a typical device containing 0.005 % w/w of graphene shows the best performance with a PCE of 1.3%, an open-circuit voltage of 0.44V, a short-circuit current density of 7.6 mA/cm{sup 2}, and a fill factor of 0.39. It is observed that the thermal annealing considerably enhances the efficiency of solar cells. However, an annealing at higher temperature such as at 140°C results in a decrease in the device efficiency.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave heating device for internal heating convection experiments, applied to Earth's mantle dynamics

We report the design, construction, and performances of a microwave (MW) heating device for laboratory experiments with non-contact, homogeneous internal heating. The device generates MW radiation at 2.47 GHz from a commercial magnetron supplied by a pulsed current inverter using proprietary, feedback based command and control hardware and software. Specially designed MW launchers direct the MW radiation into the sample through a MW homogenizer, devised to even the MW power distribution into the sample's volume. An adjustable MW circuit adapts the MW generator to the load (i.e., the sample) placed in the experiment chamber. Dedicated heatsinks maintain the MW circuits at constant temperature throughout the experiment. Openings for laser scanning for image acquisition with a CCD camera and for the cooling circuits are protected by special MW filters. The performances of the device are analyzed in terms of heating uniformity, long term output power stability, and load matching. The device is used for small scale experiments simulating Earth's mantle convection. The 30 × 30 × 5 cm{sup 3} convection tank is filled with a water‑based viscous fluid. A uniform and constant temperature is maintained at the upper boundary by an aluminum heat exchanger and adiabatic conditions apply at the tank base. We characterize the geometry of the convective regime as well as its bulk thermal evolution by measuring the velocity field by Particle Image Velocimetry and the temperature field by using Thermochromic Liquid Crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A versatile LabVIEW and field-programmable gate array-based scanning probe microscope for in operando electronic device characterization

Understanding the complex properties of electronic and spintronic devices at the micro- and nano-scale is a topic of intense current interest as it becomes increasingly important for scientific progress and technological applications. In operando characterization of such devices by scanning probe techniques is particularly well-suited for the microscopic study of these properties. We have developed a scanning probe microscope (SPM) which is capable of both standard force imaging (atomic, magnetic, electrostatic) and simultaneous electrical transport measurements. We utilize flexible and inexpensive FPGA (field-programmable gate array) hardware and a custom software framework developed in National Instrument's LabVIEW environment to perform the various aspects of microscope operation and device measurement. The FPGA-based approach enables sensitive, real-time cantilever frequency-shift detection. Using this system, we demonstrate electrostatic force microscopy of an electrically biased graphene field-effect transistor device. The combination of SPM and electrical transport also enables imaging of the transport response to a localized perturbation provided by the scanned cantilever tip. Facilitated by the broad presence of LabVIEW in the experimental sciences and the openness of our software solution, our system permits a wide variety of combined scanning and transport measurements by providing standardized interfaces and flexible access to all aspects of a measurement (input and output signals, and processed data). Our system also enables precise control of timing (synchronization of scanning and transport operations) and implementation of sophisticated feedback protocols, and thus should be broadly interesting and useful to practitioners in the field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fabrication of polyfluorene and polycarbazole-based photovoltaic devices using an air-stable process route

We report a comparative study based on the fabrication of polymer:fullerene photovoltaic (PV) devices incorporating carbazole, fluorene, and a PTB based co-polymer. We have explored the efficiency and performance of such devices when the active polymer:fullerene layer is deposited by spin-casting either under nitrogen or ambient conditions. We show that PV devices based on carbazole and fluorene based materials have very similar power conversion efficiencies when processed under both air and nitrogen, with other photobleaching measurements suggesting that such materials have comparatively enhanced photostability. Devices based on the PTB co-polymer, however, have reduced efficiency when processed in air.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Restorative effect of oxygen annealing on device performance in HfIZO thin-film transistors

Metal-oxide based thin-film transistors (oxide-TFTs) are very promising for use in next generation electronics such as transparent displays requiring high switching and driving performance. In this study, we demonstrate an optimized process to secure excellent device performance with a favorable shift of the threshold voltage toward 0V in amorphous hafnium-indium-zinc-oxide (a-HfIZO) TFTs by using post-treatment with oxygen annealing. This enhancement results from the improved interfacial characteristics between gate dielectric and semiconductor layers due to the reduction in the density of interfacial states related to oxygen vacancies afforded by oxygen annealing. The device statistics confirm the improvement in the device-to-device and run-to-run uniformity. We also report on the photo-induced stability in such oxide-TFTs against long-term UV irradiation, which is significant for transparent displays.