Convective heating measurement by means of an infrared camera
The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.