Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

RECONNECTION OF QUASI-SINGULAR CURRENT SHEETS: THE ''IDEAL'' TEARING MODE

A strong indication that fast reconnection regimes exist within resistive magnetohydrodynamics was given by the proof that the Sweet-Parker current sheet, maintained by a flow field with an appropriate inflow-outflow structure, could be unstable to a reconnecting instability which grows without bound as the Lundquist number, S, tends to infinity. The requirement of a minimum value for S in order for the plasmoid instability to kick in does little to resolve the paradoxical nature of the result. Here we argue against the realizability of Sweet-Parker current sheets in astrophysical plasmas with very large S by showing that an ''ideal'' tearing mode takes over before current sheets reach such a thickness. While the Sweet-Parker current sheet thickness scales as ∼S {sup –1/2}, the tearing mode becomes effectively ideal when a current sheet collapses to a thickness of the order of ∼S {sup –1/3}, up to 100 times thicker than S {sup –1/2}, when (as happens in many astrophysical environments) S is as large as 10{sup 12}. Such a sheet, while still diffusing over a very long time, is unstable to a tearing mode with multiple x-points: here we detail the characteristics of the instability and discuss how it may help solve the flare trigger problem and effectively initiate the turbulent disruption of the sheet.

79 ASTRONOMY AND ASTROPHYSICS↗

Entanglement of two qubits coupled to an XY spin chain: Role of energy current

We investigate the entanglement dynamics of a two-qubit system which interacts with a Heisenberg XY spin chain constrained to carry an energy current. We show an explicit connection between the decoherence factor and entanglement, and numerically and analytically study the dynamical process of entanglement in both weak- and strong-coupling cases for two initial states, the general pure state and the mixed Werner state. We provide results that the entanglement evolution depends not only on the energy current, the anisotropy parameter and the system-environment couplings but also on the size of degrees of freedom of environment. In particular, our results imply that entanglement will be strongly suppressed by the introduction of energy current on the environmental spin chain in the weak-coupling region while it is not sensitive to the energy current in the strong-coupling region. We also observe the sudden death of entanglement in the system and show how the energy current affects the phenomenon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding the impact of an applied axial magnetic field on efficient current coupling on the Z machine

Magnetized liner inertial fusion (MagLIF) is an attractive concept for producing thermonuclear fusion reactions. The MagLIF platform involves the operation of Helmholtz coils to apply a 15 Tesla axial magnetic field to the load region, where a cylindrical, fuel-filled metal liner is imploded by a ∼ 2 0 MA current pulse. The fringe field from these coils extends into the transmission line that delivers the current to the target. We investigated the extent to which this applied field disturbs the nominal power flow within that transmission line. A simplified model of the geometry shows that adding the applied magnetic field results in magnetic field lines that connect the cathode to the anode, suggesting electrons may not be magnetically insulated in this region. Particle-in-cell simulations indicated the addition of the applied magnetic field would not significantly impact the current delivery to the load. Velocimetry was used to experimentally assess the current delivery with and without the applied magnetic field. We find no measurable effects of the applied field on current delivery in the configuration investigated in this study. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chiral currents and static properties of nucleons in holographic QCD

We analyze static properties of nucleons in the two flavor holographic QCD model of Sakai and Sugimoto described effectively by a five-dimensional U(2) Yang-Mills theory with the Chern-Simons term on a curved background. The baryons are represented in this model as a soliton, which at a time slice is approximately the Belavin-Polyakov-Shvarts-Tyupkin (BPST) instanton with a fixed size. First, we construct a chiral current in four dimensions from the Noether current of local gauge transformations which are nonvanishing on the boundaries of the extra dimension. We examine this chiral current for nucleons with quantized collective coordinates to compute their charge distribution, charge radii, magnetic moments, and axial-vector coupling. Most of the results are better close to the experimental values than in the Skyrme model. We discuss the problems of our chiral current, nonuniqueness of the local gauge transformation for defining the current, and its gauge-noninvariance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laminated Permanent Magnets Enable Compact Magnetic Components in Current Source Converters

Magnetic components play a key role in determining the size, cost, efficiency of a power converter. They are more significant in current source converters, where the dc-link energy is stored in an inductor/transformer. In such cases, the magnetics have a predominantly DC flux, superimposed by an AC flux at switching frequency. Previously, permanent magnets have been proposed to offset the DC flux and thereby reduce the size, cost, and losses of the inductors/transformers. This paper starts by analyzing the issue of eddy currents when using such standard permanent magnets, especially in medium frequency applications, making them practically unusable. Alternatively, the paper proposes the use of laminated permanent magnets to reduce these eddy currents and thereby realize the benefits of offsetting the DC flux to reduce the size, cost, and loss of inductors/transformers. Using a soft-switching solid-state transformer as an example, experimental results are presented to show the impact of eddy currents in standard permanent magnets when used with a medium frequency transformer. Here, experimental results showing the benefits of using laminated magnets in reducing the eddy currents are presented.

30 DIRECT ENERGY CONVERSION↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Interlaboratory Comparisons of NbTi Critical Current Measurements

We report on a multi-institute comparison of critical current data measured on a modern NbTi wire for the Large Hadron Collider (LHC), which has shown a standard deviation below 1% in critical current density spread in more than 1500 measurements. Interlaboratory comparisons on Nb{sub 3}Sn wires have shown ambiguities that could be attributable to strain related differences in critical current density, originating from differences in sample handling, reaction, and mounting techniques, or also to differences in the magnetic field and current calibrations between the institutes. A round robin test of a well characterized NbTi wire provides a baseline variance in critical current results that is presumed to be attributable only to differences in the characterization systems. Systematic differences on the order of 3.5% are found in the comparison. The most likely cause for the observed differences is a small diameter holder that brings the wire into a strain regime in which strain effects can no longer be ignored. A NbTi round robin test, when performed properly, will separate system differences from sample specific differences and provide laboratories with an opportunity to calibrate equipment against a standard measurement.

43 PARTICLE ACCELERATORS↗

Analysis of Screening Current Effects in a Hybrid Nb$_{3}$Sn/REBCO Superconducting Accelerator Magnet Using a T - A Formulation

To explore the feasibility of using high-temperature superconducting (HTS) REBCO coated conductors in future accelerator magnets, two REBCO flat racetrack coils were fabricated using 4-mm wide EuBCO tapes at the High Energy Accelerator Research Organization (KEK). These coils were tested as an insert inside a Nb$_{3}$Sn common-coil dipole magnet, which provides a background field of up to $\sim$ 9.5T, at the Brookhaven National Laboratory (BNL). REBCO tapes offer exceptionally high critical current density under strong magnetic fields; however, they also exhibit significant magnetization due to screening currents, leading to magnetic field errors. Here, this study presents a 2D finite element model of screening current-induced fields (SCIF) in REBCO coils using the T-A formulation, along with the results obtained. Simulations were then performed for two KEK test cases: one where the REBCO conductors were oriented with the HTS tapes parallel to the background field, and another where the tapes were perpendicular to it. Since screening currents also influence the stress distribution and increase the peak stress in the coils, the mechanical effects of these currents were analyzed. The implications of these simulation and test results for the design of Nb$_{3}$Sn/REBCO superconducting accelerator magnets are discussed.

Accelerator magnets↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Efficient Modeling of Floating Wind Arrays Including Current Loads and Seabed Bathymetry

Capabilities for modeling the effects of seabed bathymetry and current drag loads on a floating wind farm are now available in an open-source model for quasi-static analysis. In this model, mooring lines and dynamic cables are represented by a quasi-static solver that can quickly represent complex mooring/cabling arrangements and arrays of floating bodies. To account for seabed bathymetry, we expand the model to include a surface mesh that captures changes in water depth over a rectangular grid. We formulate modifications to the catenary equations that capture a mooring line's profile and tensions when contacting a slope seabed. To account for current drag loads on mooring lines and dynamic cables, we formulate a novel technique that rotates the reference frame so that the vector sum of the the weight and the current force are used in the catenary equations, while accounting for the seabed orientation. To complete the system, current drag loads on floating substructures are handled by inclusion of strip-theory drag calculations. These new capabilities are verified by comparing with results from the established offshore dynamics models MoorDyn and OrcaFlex in equivalent steady-state scenarios. The results show very good agreement for both sloped seabeds and current loads. With computation times of the quasi-static model typically under one second, the model additions are a useful capability toward rapidly evaluating a floating wind array's response to environmental loads under realistic site conditions.

bathymetry↗

Dose equations for shift-variant CT acquisition modes using variable pitch, tube current, and aperture, and the meaning of their associated CTDI{sub vol}

Purpose: With the increasing clinical use of shift-variant CT protocols involving tube current modulation (TCM), variable pitch or pitch modulation (PM), and variable aperture a(t), the interpretation of the scanner-reported CTDI{sub vol} is called into question. This was addressed for TCM in their previous paper published by Dixon and Boone [Med. Phys. 40, 111920 (14pp.) (2013)] and is extended to PM and concurrent TCM/PM as well as variable aperture in this work. Methods: Rigorous convolution equations are derived to describe the accumulated dose distributions for TCM, PM, and concurrent TCM/PM. A comparison with scanner-reported CTDI{sub vol} formulae clearly identifies the source of their differences with the traditional CTDI{sub vol}. Dose distribution simulations using the convolution are provided for a variety of TCM and PM scenarios including a helical shuttle used for perfusion studies (as well as constant mA)—all having the same scanner-reported CTDI{sub vol}. These new convolution simulations for TCM are validated by comparison with their previous discrete summations. Results: These equations show that PM is equivalent to TCM if the pitch variation p(z) is proportional to 1/i(z), where i(z) is the local tube current. The simulations show that the local dose at z depends only weakly on the local tube current i(z) or local pitch p(z) due to scatter from all other locations along z, and that the “local CTDI{sub vol}(z)” or “CTDI{sub vol} per slice” do not represent a local dose but rather only a relative i(z) or p(z). The CTDI-paradigm does not apply to shift-variant techniques and the scanner-reported CTDI{sub vol} for the same lacks physical significance and relevance. Conclusions: While the traditional CTDI{sub vol} at constant tube current and pitch conveys useful information (the peak dose at the center of the scan length), CTDI{sub vol} for shift-variant techniques (TCM or PM) conveys no useful information about the associated dose distribution it purportedly represents. On the other hand, the total energy absorbed E (“integral dose”) as well as its surrogate DLP remain robust (invariant) with respect to shift-variance, depending only on the total mAs = 〈i〉t{sub 0} accumulated during the total beam-on time t{sub 0} and aperture a, where 〈i〉 is the average current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dependence of the maximal superconducting current on the resonance frequency in a shunted Josephson junction

We have analyzed the phase dynamics and current–voltage characteristics of a Josephson junction shunted by an LC circuit. When the Josephson frequency ω{sub J} becomes equal to the natural frequency ω{sub rc} of the formed resonance circuit, the I–V curve acquires additional branches. We have studied the features of the rc branch and the superconducting circuit for different values of the resonance frequency. It is shown that the maximal superconducting current through the Josephson junction on the rc-branch depends on the resonance frequency and is determined by the closeness of the end point of the rc branch to the critical current. We have determined the dependence of the maximal superconducting current on the resonance frequency for different values of the dissipation parameters. The limiting value of the maximal superconducting current is independent (to within 1%) of the parameters of the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the current-sheath formation during the implosion of multishell gas puffs

Results are presented from experimental studies of the dynamics of large-diameter multishell gas puffs imploded by microsecond megampere current pulses. The experiments were conducted on the GIT-12 generator in the regime of microsecond implosion (t{sub imp} = 1.1-1.2 {mu}s, I{sub 0} = 3.4-3.7 MA). The influence of the load configuration on the dynamics of current losses and gas-puff radiative characteristics was studied. The correlation between the radial compression ratio (the ratio between the initial and final Z-pinch radii) and the magnitude of the current flowing at the plasma periphery was investigated. The experiments show that, in a multishell gas puff, large-scale instabilities insignificantly affect the gas-puff implosion even over microsecond time intervals and that a compact dense pinch with a relatively high average electron temperature (400-600 eV) forms at the Z-pinch axis. The diameter of the plasma column radiating in the K-shell lines of neon is about 3-4 mm, the K-shell radiation yield being 5-11 kJ/cm. In the final stage of implosion, only a small portion of the current flows through the high-temperature central region of the pinch plasma, whereas the major part of the generator current flows through the residual peripheral plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structure of the controlled halo-current magnetic field in the T-10 tokamak

In the T-10 tokamak, the magnetic field spatially resonant with a helical MHD perturbation is generated using the controlled halo current supplied using a contact method in the scrape-off-layer plasma. This paper is concerned with studying the spatial structure of the halo current and its magnetic field. For this purpose, the magnetic field of the halo current was measured in one of the cross sections of the torus near the tokamak vacuum vessel wall. The spatial distribution of the magnetic field as a function of the halo current configuration was calculated in the cylindrical approximation. The terms proportional to the plasma pressure were disregarded. The configuration of the halo current and the spatial structure of its magnetic field were determined by comparing the calculated and experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamics of the structure of the plasma current sheath in a plasma focus discharge

The study is aimed at investigating the fine structure of the plasma current sheath (PCS) in the PF-3 plasma focus facility. The PCS dynamics in a deuterium discharge was studied. The PCS parameters were measured using absolutely calibrated magnetic probes installed at different positions with respect to the facility axis and the anode surface. A magneto-optical probe recording both the magnetic signal and the PCS optical luminosity was first applied to analyze the PCS structure. This made it possible to spatially resolve the current and shock-wave regions. It is demonstrated that the current distribution is different in different discharge stages. It is shown that the neutron yield is determined by the value of the current compressed toward the axis, rather then the amplitude of the total discharge current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Drift modes of a quasi-two-dimensional current sheet

Stability of a plasma configuration consisting of a thin one-dimensional current sheet embedded into a two-dimensional background current sheet is studied. Drift modes developing in plasma as unstable waves along the current direction are considered. Dispersion relations for kink and sausage perturbation modes are obtained depending on the ratio of parameters of thin and background current sheets. It is shown that the existence of the background sheet results in a decrease in the instability growth rates and a significant increase in the perturbation wavelengths. The role of drift modes in the excitation of oscillations observed in the current sheet of the Earth's magnetotail is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the behavior of plasma with a negative current in the L-2M stellarator

The behavior of plasma with a negative current in the range of 5 kA ≤ vertical bar J vertical bar ≤ 16 kA in the L-2M stellarator is studied. Plasma is created and heated by means of electron cyclotron resonance heating (ECRH). Here, the definition “negative” stands for a toroidal current directed in such a way that it reduces the initial rotational transform µ in absolute value. It is shown that, only at relatively small values of the negative current ( vertical bar J vertical bar ∼ 6 kA), the increase in the shear leads to a reduction in electromagnetic turbulence. As vertical bar J vertical bar rises, the average level of magnetic fluctuations in the stationary phase of the discharge gradually increases. After ECRH is switched off (i.e., when plasma cools down), there is a time interval in which the amplitude of magnetic field fluctuations increases. No coherent three-dimensional modes (e.g., double tearing modes) that could accompany the penetration of the current into the plasma were observed. As for axisymmetric perturbations with m ≠ 0, analysis of the experimental data shows that they are absent at vertical bar J vertical bar ≤ 8 kA, appear in some discharges at vertical bar J vertical bar = 9 kA, and are observed in each discharge at vertical bar J vertical bar ≥ 10 kA. The frequency of these oscillations is on the order of 10 kHz, the poloidal mode number is m = 2, and the duration is 4–6 ms. The absence of oscillations with m = 1 and the small value of the external magnetic field for the m = 2 perturbation indicate that the radial size of the magnetic island is less than 1 cm. This, in turn, suggests that the radial profile of the plasma current changes with increasing vertical bar J vertical bar.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗