Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High Energy Micron Scale Pixel Hybrid Detector

The objective of this technology development project has been to fabricate and characterize a new X-ray area image sensor innovation designed for high efficiency detection and imaging of hard X-rays (>20 KeV) with micron scale pixel resolution. A key technology component consists of a monolithic hybrid X-ray detector built by layering an amorphous Selenium X-ray photoconductor film directly deposited on a small pitch (7.8μm) CMOS active pixel readout array. A specific goal of this work is to provide a new detector tool to researchers working with synchrotron light sources, to extend the depth of exploration into nanoscale structures, and do so cost effectively. Early generation X-ray imaging detector tools fail to provide adequate resolving power and efficiency at high energies and our innovation provides a solution. A majority of proposed phase I tasks were completed. Those tasks included, in collaboration with KA Imaging, successful fabrication of specified a-Se layers on a 1Mpixel CMOS readout array to create the direct hybrid X-ray imaging array, packaging of the imaging array, assembly of electronics into a shielded detector box, loading user interface software for camera control and image capture, and performing initial (no X-ray) detector evaluation at Farrier Microengineering facilities. After initial tests, extensive testing using the X-ray beam line 1-BM source at Argonne National Laboratory Advanced Photon Source(ANL-APS) was performed. Imaging performance studies were conducted at multiple X-ray beam energies. Studies included X-ray response vs. X-ray energy, vs. applied detector field strength (HV), response linearity vs. integration time, MTF vs. beam energy, image lag measurements, and micron scale resolution pattern target imaging. This high energy micron scale X-ray detection technology is a first of a kind to be evaluated at the ANL-APS and is supported by Dr. Antonino Miceli, head of the detector physics group. Accomplishments include the first successful demonstration of a 1Mpix amorphous Selenium on CMOS readout direct hybrid X-ray imaging detector at a DOE sponsored National Laboratory. Modeled performance predictions were confirmed, proving micron scale resolution as well as an order of magnitude increase in conversion efficiency over conventional scintillator detector performance. A discovery of evidence of propagation-based phase contrast edge enhancement was unplanned and will be exploited in future experiments. This phase 1 technology demonstration verifies the efficacy of proposed high energy micron scale pixel X-ray hybrid a-Se imaging array products. The new detector products will cost effectively replace early generation detector technologies that currently fail to address increasing demand for tools to study nano structures and physical processes at high X-ray energies above 20keV. For example, current systems for transmission X-ray microscopy have low efficiency and available large pixel (~55µm) direct detectors do not offer sufficient resolution for Bragg fringe imaging at high energies. This detector innovation will solve these inadequacies. The new detector technology will compete in a $50M scientific X-ray detector market, growing at 6%, and will benefit Microtomography(µCT), X-ray diffractometry (XRD), Coherent Diffraction Imaging (CDI) applications. One application specified by Dr. Miceli at ANL is the 3D reconstruction of compact crystals at high energies requires small pixel high efficiency X-ray detectors. Farrier Microengineering, working with colleagues at KA Imaging and the University of Waterloo, successfully achieved the critical objectives of the Phase I proposal. We have proven the technical feasibility of this innovation by building and successfully testing a 1Mpixel a-Se/CMOS hybrid direct X-ray imaging array. Our commercialization roadmap of detector products will be implemented during a phase II project. We will demonstrate a migration of the technology to larger detector array sizes, improved temporal performance with detector layer engineering, and improved environmental and operational stability. Manufacturability and cost effectiveness are key objectives and product designs will leverage current state of the art CMOS wafer fabrication quality and volume manufacturing economics.

36 MATERIALS SCIENCE↗

Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along the building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial costs. However, when the life-cycle costs from energy and maintenance were factored into the scenario, the LED system had lower costs at the end of a 10-year analysis period. The LED system had a 6.1 year payback compared to the 1000W PMH system and a 7.5 year payback versus the 400W PMH system. The costs reflect high initial cost for the LED luminaire, plus more luminaires and (subsequently) more poles for the LED system. The other major issue affecting cost effectiveness was that Leavenworth, Kansas has very low electricity costs. The melded rate for this site was $0.056 per kWh for electricity. However, if the national electricity rate of $0.1022/kWh was used the payback would change to between four and five years for the LED system. This demonstration met the GATEWAY requirements of saving energy, matching or improving illumination, and being cost effective. The project also demonstrated that the Commercial Building Energy Alliance (CBEA) specification works in practice. Walmart appreciated having an entire site lighted by LEDs to gain more experience with the technology. Walmart is reviewing the results of the demonstration as they consider their entire real estate portfolio.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spin‐State and Clustering Effects in Fe‐Complex Negolytes for Near‐Neutral Aqueous Redox Flow Batteries

Cost-effective redox-active materials are essential for advancing redox flow batteries (RFBs). Iron, with its abundance and suitability as a redox couple, is a promising candidate; however, achieving stable and fast redox reactions in aqueous RFBs remains a challenge. Here, this study presents an Fe-based negolyte stabilized by a hexadentate ligand, where Fe–ligand bonds are enhanced through intermolecular interactions. The sulfonate-substituted Fe complex exhibits a formal potential of −0.44 V versus Ag/AgCl and an exceptionally high rate constant of 0.69 cm s −1 . Near-neutral RFBs incorporating 0.5 M Fe complex show excellent cycling stability, with no discernible capacity fading over 300 cycles. This performance is attributed to intermolecular hydrogen bonds that reinforce Fe–ligand coordination and promote the formation of stable trimeric clusters. Operando electrochemical Raman spectroscopy and density functional theory reveal that π-backdonation from Fe(II) to the imino-phenolate moiety further stabilizes the complex after reduction. In contrast, the hydroxyl-substituted complex exhibits inferior stability due to weaker hydrogen bonding and less pronounced π-backdonation. These findings underscore the importance of ligand design and intermolecular interactions in developing cost-effective, high-performance redox-active materials for aqueous RFBs.

36 MATERIALS SCIENCE↗

Feasible conversion of solid waste bauxite tailings into highly crystalline 4A zeolite with valuable application

Highlights: • Concept to convert waste to valuable product is carried out in this study. • An industrially feasible and cost-effective approach was developed and optimized. • Highly crystalline and well-defined zeolite was produced under moderate conditions. • The zeolite derived from the bauxite tailings displayed high ion exchange capacity. • Bauxite tailings have potential application in heavy metal ions adsorbent. - Abstract: Bauxite tailings are a major type of solid wastes generated in the flotation process. The waste by-products caused significant environmental impact. To lessen this hazardous effect from poisonous mine tailings, a feasible and cost-effective solution was conceived and implemented. Our approach focused on reutilization of the bauxite tailings by converting it to 4A zeolite for reuse in diverse applications. Three steps were involved in the bauxite conversion: wet-chemistry, alkali fusion, and crystallization to remove impurities and to prepare porous 4A zeolite. It was found that the cubic 4A zeolite was single phase, in high purity, with high crystallinity and well-defined structure. Importantly, the 4A zeolite displayed maximum calcium ion exchange capacity averaged at 296 mg CaCO{sub 3}/g, comparable to commercially-available zeolite (310 mg CaCO{sub 3}/g) exchange capacity. Base on the optimal synthesis condition, the reaction yield of zeolite 4A from bauxite tailings achieved to about 38.43%, hence, this study will provide a new paradigm for remediation of bauxite tailings, further mitigating the environmental and health care concerns, particularly in the mainland of PR China.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stimuli-Responsive/Rheoreversible Hydraulic Fracturing Fluids as a Greener Alternative to Support Geothermal and Fossil Energy Production

Cost-effective yet safe creation of high-permeability reservoirs within deep bedrock is the primary challenge for the viability of enhanced geothermal systems (EGS) and unconventional oil/gas recovery. Although fracturing fluids are commonly used for oil/gas, standard fracturing methods are not developed or proven for EGS temperatures and pressures. Furthermore, the environmental impacts of currently used fracturing methods are only recently being determined. Widespread concerns about the environmental contamination have resulted in a number of regulations for fracturing fluids advocating for greener fracturing processes. To enable EGS feasibility and lessen environmental impact of reservoir stimulation, an environmentally benign, CO2-activated, rheoreversible fracturing fluid that enhances permeability through fracturing (at significantly lower effective stress than standard fracturing fluids) due to in situ volume expansion and gel formation is investigated herein. The chemical mechanism, stability, phase-change behavior, and rheology for a novel polyallylamine (PAA)-CO2 fracturing fluid was characterized at EGS temperatures and pressures. Hydrogel is formed upon reaction with CO2 and this process is reversible (via CO2 depressurization or solubilizing with a mild acid) allowing removal from the formation and recycling, decreasing environmental impact. Rock obtained from the Coso geothermal field was fractured in laboratory experiments under various EGS temperatures and pressures with comparison to standard fracturing fluids, and the fractures were characterized with imaging, permeability measurement, and flow modeling. This novel fracturing fluid and process may vastly reduce water usage and the environmental impact of fracturing practices and effectively make EGS production and unconventional oil/gas exploitation cost-effective and cleaner.

Environmental Molecular Sciences Laboratory↗

Space payload dynamic testing

More cost effective methods for insuring payload reliability are required to efficiently utilize the projected payload capacity of future space systems such as the Space Shuttle. Studies are needed to better define the vibration environment of space vehicles to develop improved and more routine methods of testing and to develop better dynamic protection systems. Such improvements in environment definition, testing, and isolation will lead to less stringent design specification, improved payload reliability, fewer and more realistic qualification and flight acceptance tests. This paper presents current payload test philosophies, effectiveness of testing, and research needed to achieve more cost effective payload reliability for future applications.

Pinson, L. D.↗

Hybrid RF / Optical Communication Terminal with Spherical Primary Optics for Optical Reception

Future deep space communications are likely to employ not only the existing RF uplink and downlink, but also a high capacity optical downlink. The Jet Propulsion Laboratory (JPL) is currently investigating the benefits of a ground based hybrid RF and deep space optical terminal based on limited modification of existing 34 meter antenna designs. The ideal design would include as large an optical aperture as technically practical and cost effective, cause minimal impact to RF performance, and remain cost effective even when compared to a separate optical terminal of comparable size. Numerous trades and architectures have been considered, including shared RF and optical apertures having aspheric optics and means to separate RF and optical signals, plus, partitioned apertures in which various zones of the primary are dedicated to optical reception. A design based on the latter is emphasized in this paper, employing spherical primary optics and a new version of a "clamshell" corrector that is optimized to fit within the limited space between the antenna sub-reflector and the existing apex structure that supports the subreflector. The mechanical design of the hybrid accommodates multiple spherical primary mirror panels in the central 11 meters of the antenna, and integrates the clamshell corrector and optical receiver modules with antenna hardware using existing attach points to the maximum extent practical. When an optical collection area is implemented on a new antenna, it is possible to design the antenna structure to accommodate the additional weight of optical mirrors providing an equivalent aperture of several meters diameter. The focus of our near term effort is to use optics with the 34 meter DSS-13 antenna at Goldstone to demonstrate spatial optical acquisition and tracking capability using an optical system that is temporarily integrated into the antenna.

optical communications↗

Mechanically Tunable Radiative Cooling for Adaptive Thermal Control

Passive radiative cooling is currently thefrontier technology in renewable-energy research. Interms of extraterrestrial applications, radiative cooling is a critical component to the thermalmanagement system of a spacecraft, where the extreme environment of space can cause largetemperature variations that can break and damage equipment. For terrestrial applications,nocturnal or daytime radiative cooling is expected to lead to cost-effective passive heatmanagement without the need of inefficient and costly artificial refrigeration technologies.However, most currently available radiative cooling systems cannot be changed dynamically andradiate a constant static amount of thermal power. Dynamically tunable adaptive radiativecooling systems will be a critical development to prolong the lifetime of spacecraft or improvethe efficiency of terrestrial cooling systems. Here we propose stretchable radiative coolingdesigns that can be substantially tuned by using the simple physical mechanism of mechanical strain. When their structure is stretched, the radiated power is significantly reduced. We developa modeling method that can simulate mechanical stretching combined with electromagnetic response to compute the tunable thermal emission of these new adaptive radiative coolingsystems. The presented photonically engineered structures can be used as coatings to achieveefficient adaptive thermal control of various objects in a cost-effective and environmentallyfriendly way. The proposed designs are much simpler to be realized than others found in theliterature and the best design achieves a high thermal emission power with a tunable range on theorder of 132 W/m2.

Andrew Butler↗

Cooperative Research and Development Agreement between National Energy Technology Laboratory and Birla Carbon U.S.A., Inc. [Final Report]

NETL researchers collaborated with Birla Carbon, U.S.A., to leverage NETL's patented catalyst work on methane decomposition to develop a cost-effective process for production of hydrogen and valuable carbon from natural gas. This process is cost-effective, energy efficient and environmentally friendly with minimal CO 2 mitigation costs. The objectives of the project include evaluation of effect of feed gas composition of natural gas on the performance, lowering the catalyst production cost and to conduct cost analysis for a process.

03 NATURAL GAS↗

Wafer integrated micro‐scale concentrating photovoltaics

Abstract A novel micro‐scale photovoltaic concept, Wafer Integrated Micro‐scale Photovoltaics (WPV), is proposed, analyzed, and experimentally demonstrated. The WPV concept seamlessly integrates multijunction micro‐cells with a multi‐functional silicon platform that simultaneously provides optical concentration, hybrid PV/CPV architecture, and mechanical alignment features. Fabrication and optical performance characterization of the Si platform are described in this paper. Over 100% improvement in the concentration‐acceptance‐angle product ( CAP ) is demonstrated using the wafer‐embedded micro‐concentrating elements, leading to significantly reduced module material and fabrication costs, sufficient angular tolerance for low‐cost trackers, and an ultra‐compact optical architecture compatible with commercial flat panel infrastructures. The development of a prototypical module with a 400× concentration ratio is described. Outdoor optical characterization of the module shows acceptance angles of ±1.7° and ±2.5° for 90% of on‐axis power and full‐width‐half‐maximum, respectively. The projected performance of the PV/CPV hybrid architecture illustrates its potential for cost‐effective collection of both direct and diffuse sunlight, thereby extending the geographic and market domains for cost‐effective PV system deployment. Leveraging low‐cost micro‐fabrication and high‐level integration techniques, the WPV approach presents a promising route to combine the high performance of multijunction solar cells and the low costs of flat‐plate Si PV systems.

Li, Duanhui↗

Large-Scale and Extreme-Scale Computing with Stranded Green Power: Opportunities and Costs

Power consumption and associated carbon emissions are increasingly critical challenges for large-scale computing. Recent research proposes exploiting stranded power-uneconomic renewable power-for green supercomputing in a system called Zero-Carbon Cloud (ZCCloud). These efforts studied production supercomputing workloads on stranded-power based computing resources, demonstrating their achievable productivity. We explore economic viability of stranded-power based supercomputing, using three datacenter total-cost-of-ownership (TOO) models to study cost-effectiveness. These studies show that ZCCloud's approach can be cost-effective in the USA today, and is even more attractive in regions with higher power prices (e.g., Japan, Germany), achieving cost advantages as large as 50 percent. Environmental and power-grid benefits are a further advantage. We also explore the sensitivity of these results to changes in hardware TOO; cheaper hardware or longer lifetimes magnify the attractiveness of stranded-power based approaches, yielding advantages as large as 91 percent. These results are robust across different TCO models. Lastly, we study extreme-scale supercomputers ( >100 MW), finding stranded-power can increase peak capability per cost by as much as 80 percent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CO 2 Capture from Flue Gas Using Solid Molecular Basket Sorbents

The objective of this project is to develop a new generation of solid, regenerable polymeric molecular basket sorbent (MBS) for more cost-efficient capture and separation of CO 2 from flue gas of coal-fired power plants. The primary goal is to develop a cost-effective MBS sorbent with better thermal stability. To improve the cost-effectiveness of MBS, we have explored commercially available and inexpensive support to replace the more expensive mesoporous molecular sieves like MCM-41 and SBA-15. In addition, we have developed some advanced sorbent materials with 3D pore structure such as hexagonal mesoporous silica (HMS) to improve the CO 2 working capacity of MBS, which can also reduce the cost for the whole CO 2 capture process. During the project duration, the concern regarding the desorption rate of MBS sorbents has been raised, because lower desorption rate increases the desorption time for complete regeneration of the sorbent which in turn leads to a lower working capacity if the regeneration time is limited. Thus, the improvement in the thermal stability of MBS became a vital task for later part of this project. The improvement in the thermal stability was performed via increasing the polymer density either using higher molecular weight PEI or PEI cross-linking with an organic compound. Moreover, we have used the computational approach to estimate the interaction of CO 2 with different MBSs for the fundamental understanding of CO 2 sorption, which may benefit the development, design and modification of the sorbents and the process.

20 FOSSIL-FUELED POWER PLANTS↗

Compact Buried Ducts in a Hot-Humid Climate House

"9A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences; 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs; 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Compact Buried Ducts in a Hot-Humid Climate House, Lady's Island, South Carolina

A system of compact, buried ducts provides a high-performance and cost-effective solution for delivering conditioned air throughout the building. This report outlines research activities that are expected to facilitate adoption of compact buried duct systems by builders. The results of this research would be scalable to many new house designs in most climates and markets, leading to wider industry acceptance and building code and energy program approval. The primary research question with buried ducts is potential condensation at the outer jacket of the duct insulation in humid climates during the cooling season. Current best practices for buried ducts rely on encapsulating the insulated ducts with closed-cell spray polyurethane foam insulation to control condensation and improve air sealing. The encapsulated buried duct concept has been analyzed and shown to be effective in hot-humid climates. The purpose of this project is to develop an alternative buried duct system that performs effectively as ducts in conditioned space - durable, energy efficient, and cost-effective - in a hot-humid climate (IECC warm-humid climate zone 3A) with three goals that distinguish this project: 1) Evaluation of design criteria for buried ducts that use common materials and do not rely on encapsulation using spray foam or disrupt traditional work sequences, 2) Establishing design criteria for compact ducts and incorporate those with the buried duct criteria to further reduce energy losses and control installed costs, and 3) Developing HVAC design guidance for performing accurate heating and cooling load calculations for compact buried ducts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PRA (Probabilistic Risk Assessments) Participation versus Validation

Probabilistic Risk Assessments (PRAs) are performed for projects or programs where the consequences of failure are highly undesirable. PRAs primarily address the level of risk those projects or programs posed during operations. PRAs are often developed after the design has been completed. Design and operational details used to develop models include approved and accepted design information regarding equipment, components, systems and failure data. This methodology basically validates the risk parameters of the project or system design. For high risk or high dollar projects, using PRA methodologies during the design process provides new opportunities to influence the design early in the project life cycle to identify, eliminate or mitigate potential risks. Identifying risk drivers before the design has been set allows the design engineers to understand the inherent risk of their current design and consider potential risk mitigation changes. This can become an iterative process where the PRA model can be used to determine if the mitigation technique is effective in reducing risk. This can result in more efficient and cost effective design changes. PRA methodology can be used to assess the risk of design alternatives and can demonstrate how major design changes or program modifications impact the overall program or project risk. PRA has been used for the last two decades to validate risk predictions and acceptability. Providing risk information which can positively influence final system and equipment design the PRA tool can also participate in design development, providing a safe and cost effective product.

DeMott, Diana↗

An Exploratory Study of Cost Engineering in Axiomatic Design: Creation of the Cost Model Based on an FR-DP Map

Large complex projects cost large sums of money throughout their life cycle for a variety of reasons and causes. For such large programs, the credible estimation of the project cost, a quick assessment of the cost of making changes, and the management of the project budget with effective cost reduction determine the viability of the project. Cost engineering that deals with these issues requires a rigorous method and systematic processes. This paper introduces a logical framework to a&e effective cost engineering. The framework is built upon Axiomatic Design process. The structure in the Axiomatic Design process provides a good foundation to closely tie engineering design and cost information together. The cost framework presented in this paper is a systematic link between the functional domain (FRs), physical domain (DPs), cost domain (CUs), and a task/process-based model. The FR-DP map relates a system s functional requirements to design solutions across all levels and branches of the decomposition hierarchy. DPs are mapped into CUs, which provides a means to estimate the cost of design solutions - DPs - from the cost of the physical entities in the system - CUs. The task/process model describes the iterative process ot-developing each of the CUs, and is used to estimate the cost of CUs. By linking the four domains, this framework provides a superior traceability from requirements to cost information.

Lee, Taesik↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗