Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Electroweak corrections to the Charm-Top-Quark Contribution to ϵ K

We calculate the leading-logarithmic and next-to-leading-logarithmic electroweak corrections to the charm-top-quark contribution to the effective |ΔS| = 2 Lagrangian, relevant for the parameter ϵ K . We find that these corrections lead to a –0.5% shift in the corresponding Wilson coefficient. Moreover, our calculation removes an implicit ambiguity in the standard-model prediction of ϵ K , by fixing the renormalization scheme of the electroweak input parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reference range of liver corrected T1 values in a population at low risk for fatty liver disease—a UK Biobank sub-study, with an appendix of interesting cases

Purpose: Corrected T1 (cT1) value is a novel MRI-based quantitative metric for assessing a composite of liver inflammation and fibrosis. It has been shown to distinguish between non-alcoholic fatty liver disease (NAFL) and non-alcoholic steatohepatitis. However, these studies were conducted in patients at high risk for liver disease. This study establishes the normal reference range of cT1 values for a large UK population, and assesses interactions of age and gender. Methods: MR data were acquired on a 1.5 T system as part of the UK Biobank Imaging Enhancement study. Measures for Proton Density Fat Fraction and cT1 were calculated from the MRI data using a multiparametric MRI software application. Data that did not meet quality criteria were excluded from further analysis. Inter and intra-reader variability was estimated in a set of data. A cohort at low risk for NAFL was identified by excluding individuals with BMI ≥ 25 kg/m{sup 2} and PDFF ≥ 5%. Of the 2816 participants with data of suitable quality, 1037 (37%) were classified as at low risk. Results: The cT1 values in the low-risk population ranged from 573 to 852 ms with a median of 666 ms and interquartile range from 643 to 694 ms. Iron correction of T1 was necessary in 36.5% of this reference population. Age and gender had minimal effect on cT1 values. Conclusion: The majority of cT1 values are tightly clustered in a population at low risk for NAFL, suggesting it has the potential to serve as a new quantitative imaging biomarker for studies of liver health and disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wavelet-based algorithm for correction of beam-steering artefacts in turbulent flow imaging at elevated pressures

Beam steering by index-of-refraction gradients poses a significant challenge for laser-based imaging measurements in turbulent reacting and non-reacting flows, particularly at elevated pressures. High fidelity imaging and quantitative data interpretation in turbulent flows can be considerably impeded by artefacts generated from beam steering. A wavelet-based filtering scheme has been developed to recover the underlying turbulent flow structures from imaging measurements containing severe beam-steering artefacts. This analysis technique is equally applicable to imaging measurements in reacting and non-reacting flows. It is demonstrated using mixture fraction measurements in a transient turbulent jet flow at 8 bar using Rayleigh scattering imaging at a repetition rate of 100 kHz. In this paper, the corrected images reveal the temporal evolution of flow structures with negligible residual beam-steering artefacts. Tests of the sensitivity of the wavelet-based filtering scheme to noise and spatial resolution indicate that it is a robust analytic tool for correcting severe beam-steering artefacts commonly encountered in laser-based imaging measurements at elevated pressures.

47 OTHER INSTRUMENTATION↗

Radiative Corrections to Neutron Beta Decay and (Anti)Neutrino-Nucleon Scattering from Low-Energy Effective Field Theory

Herein we study radiative corrections to neutron beta decay and low-energy (anti)neutrino-nucleon scattering within a top-down effective field theory approach. As it was recently shown, a few electromagnetic and electroweak low-energy coupling constants in heavy-baryon chiral perturbation theory are yet to be determined. Performing matching to the four-fermion effective field theory, we relate these low-energy constants to correlation functions of vector and axial-vector currents. Such relations allow us to explicitly clarify scheme dependence for radiative corrections to neutron decay and low-energy charged-current (anti)neutrino scattering, provide a robust prediction of leading in the electromagnetic coupling constant contributions, and achieve a clear separation between short-distance and long-distance contributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Correction to: Simultaneous Modification of Alumina and MgO·Al 2 O 3 Inclusions by Calcium Treatment During Electroslag Remelting of Stainless Tool Steel

In Table III, the correct value of first-order interaction parameter of Cr on S should be -0.0105, rather than 0.0105. It should be stressed that the thermodynamic calculation associated with this parameter was performed using e S Cr = - 0.0105 in the published article. Thus, all calculated results associated with this parameter are correct in this article.

36 MATERIALS SCIENCE↗

Correction to: Hesperetin induces the apoptosis of hepatocellular carcinoma cells via mitochondrial pathway mediated by the increased intracellular reactive oxygen species, ATP and calcium

The original version of this article unfortunately contained a mistake. During final figure preparation and manuscript submission, the similar graphs (Fig. 6c) in different papers were accidentally switched. It was subsequently noted in a further review that Fig. 2a does not match with the hesperetin concentration. The corrected figures and graphs are herein (Figs. 2a, 6c). This correction does not affect the results or conclusions of the original paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrected coronary opacification decrease from coronary computed tomography angiography: Validation with quantitative 13N-ammonia positron emission tomography

Background: To assess the functional relevance of a coronary artery stenosis, corrected coronary opacification (CCO) decrease derived from coronary computed tomography angiography (CCTA) has been proposed. The present study aims at validating CCO decrease with quantitative 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI). Methods and Results: This retrospective study consists of 39 patients who underwent hybrid CCTA/PET-MPI. From CCTA, attenuation in the coronary lumen was measured before and after a stenosis and corrected to the aorta to calculate CCO and its decrease. Relative flow reserve (RFR) was calculated by dividing the stress myocardial blood flow (MBF) of a vessel territory subtended by a stenotic coronary by the stress MBF of the reference territories without stenoses. RFR was abnormal in 11 vessel territories (27%). CCO decrease yielded a sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for prediction of an abnormal RFR of 73%, 70%, 88%, 47%, and 70%, respectively. Conclusions: CCTA-derived CCO decrease has moderate diagnostic accuracy to predict an abnormal RFR in PET-MPI. However, its high negative predictive value to rule out functional relevance of a given lesion may confer clinical implications in the diagnostic work-up of patients with a coronary stenosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: ACC/AATS/AHA/ASE/ASNC/SCAI/SCCT/STS 2017 Appropriate Use Criteria for Coronary Revascularization in Patients With Stable Ischemic Heart Disease

To more clearly reflect the relationship between iFR (instantaneous wave-free ratio) and FFR (fractional flow reserve), this Correction document highlights the following changes to the original document published in the Journal of Nuclear Cardiology; the version available at JACC [1] has been updated to reflect the changes, with JACC’s Correction document available at [2].

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Correction to: The effect of beta blocker withdrawal on adenosine myocardial perfusion imaging

Regrettably the original version of the above article contained errors in Table 2 and wrong values in the text. The corrected table is presented here and the values which have been corrected now appear in bold text. Page 1223 abstract Global MBF showed an increase from 180.2 ± 59.9 to 193.6 ± 60.8 mL minute/100 g (P = .002) after beta blocker withdrawal. Page 1225 Mean systolic and mean diastolic blood pressure during adenosine were nearly identical (P = .77 and P = .79) with and without beta blocker. Mean heart rate and mean RPP during adenosine significantly increased after beta blocker withdrawal by 15.2% ± 17% (P = .001) and 16.2% ± 23% (P = .004), respectively. Page 1226 The data are listed in Table 2, lower third. Global MBF showed a significant increase by 7.4% ± 10% (P = .002) after beta blocker withdrawal. The individual data are depicted in Figure 1. All but three patients had a lower global MBF without beta blocker than with. The segmental MBF values (Figure 2) demonstrated a strong correlation over the entire range of perfusion values. The average effect was a slight perfusion shift of about 1015 mL minute-1/100 g in the range of 100-300 mL minute-1/100 g. The mCR under adenosine declined by 8.1% ± 11% (P = .038) and the normalized RPP by 16.2% ± 21% (P = .004) after betablocker discontinuation. Table 2 Hemodynamic response under adenosine, perfusion, and left-ventricular function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An AFM Dynamic Contact Model with Finite Thickness Correction to Study Micro-Rheology of Biological Cells

One of the major sources of error in Atomic Force Microscopy based Force Spectroscopic studies is bottom substrate effect, which comes due to assumption of infinite sample thickness. In the present work, anew experimentally validated mathematical correction for finite thickness of thesample is incorporated into a dynamic indentation model. This model is an extension of Sneddon’s static indentation contact model developed for conical tip indenters by incorporating the tip geometric effects, correction to hydrodynamic drag, viscoelastic nature of the sample and its finite thickness. The new model is applied to extract the viscoelastic properties of primary mesenchymal stem cells (MSC’s) extracted from human bone marrow and HCT-116 aggressive epithelial colorectal cancer cells. The micro-rheological studies indicated the presence of profound influence of infinite thickness assumption depending upon indentation depth and sample thickness at the point of indentation. The present model nullified this error and provided a better estimate of the rheological properties. The tests were conducted over a wide frequency bandwidth (0.5 to 126 Hz) and frequency dependent material properties were analyzed using power law structural damping model. It was found that MSC’s are stiffer and less viscous in nature compared to cancer cells.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correction to: Shock Response of Polymethylmethacrylate

Table 1 had incorrect densities for the RH and Poly samples. The correct density for RH samples is 1.1892 ± 0.0003 g/cm 3 . The correct density for Poly samples is 1.1842 ± 0.0004 g/cm 3 . The authors thank Christopher Neel from the Air Force Research Laboratory for bringing this error to our attention. Additionally, there is an error in Eq. (6). 1.7576 × 10 -2 should be 1.7576 × 10 -7 .

36 MATERIALS SCIENCE↗

In vivo gene correction with targeted sequence substitution through microhomology-mediated end joining

Highlights: • A novel microhomology mediated end joining (MMEJ) gene correction method was tested. • MMEJ resulted in precise targeted sequence substitution (TSS) in vitro and in vivo. • MMEJ-TSS showed superior efficiency than homology-directed repair (HDR) in vitro. • MMEJ-TSS resulted in the survival of mice model of hereditary tyrosinemia in vivo. • MMEJ-TSS could overcome the limitations of HDR for gene therapy. Genome editing technology using programmable nucleases has rapidly evolved in recent years. The primary mechanism to achieve precise integration of a transgene is mainly based on homology-directed repair (HDR). However, an HDR-based genome-editing approach is less efficient than non-homologous end-joining (NHEJ). Recently, a microhomology-mediated end-joining (MMEJ)-based transgene integration approach was developed, showing feasibility both in vitro and in vivo. We expanded this method to achieve targeted sequence substitution (TSS) of mutated sequences with normal sequences using double-guide RNAs (gRNAs), and a donor template flanking the microhomologies and target sequence of the gRNAs in vitro and in vivo. Our method could realize more efficient sequence substitution than the HDR-based method in vitro using a reporter cell line, and led to the survival of a hereditary tyrosinemia mouse model in vivo. The proposed MMEJ-based TSS approach could provide a novel therapeutic strategy, in addition to HDR, to achieve gene correction from a mutated sequence to a normal sequence.

60 APPLIED LIFE SCIENCES↗

Effects of operator splitting and low Mach-number correction in turbulent mixing transition simulations

In this paper, transition and turbulence decay with the Taylor–Green vortex have been effectively used to demonstrate emulation of high Reynolds-number ( R e ) physical dissipation through numerical convective effects of various non-oscillatory finite-volume algorithms for implicit large eddy simulation (ILES), e.g. using the Godunov-based Eulerian adaptive mesh refinement code xRAGE. The inverse-chevron shock tube experiment simulations have been also used to assess xRAGE based ILES for shock driven turbulent mixing, compared with available simulation and laboratory data. The previous assessments are extended to evaluate new directionally-unsplit high-order algorithms in xRAGE, including a correction to address the well-known issue of excessive numerical diffusion of shock-capturing (e.g., Godunov-type) schemes for low Mach numbers. The unsplit options for hydrodynamics in xRAGE are discussed in detail, followed by fundamental tests with representative shock problems. Basic issues of transition to turbulence and turbulent mixing are discussed, and results of simulations of high- R e turbulent flow and mixing in canonical test cases are reported. Finally, compared to the directional-split cases, and for each grid resolution considered, unsplit results exhibit transition to turbulence with much higher effective R e —and significantly more so with the low Mach number correction.

97 MATHEMATICS AND COMPUTING↗

Polarization loss correction derived from hydrogen local-resistance measurement in low Pt-loaded polymer-electrolyte fuel cells

The reduction of platinum-loading on the cathode side of polymer-electrolyte fuel cells leads to a poorly understood increase in mass-transport resistance (MTR) at high current densities. This local resistance was measured using a facile hydrogen-pump technique with dilute active gases for membrane-electrode assemblies with catalyst layers of varying platinum-loading (0.03-0.40 mgPt/cm²). Furthermore, polarization curves in H 2 /air were measured and corrected for the overpotential caused by the increased MTR for low loadings on the air side due to the reduced concentration of reactant gas at the catalyst surface. The difference in performance after correction for all resistances including the MTR is minor, suggesting its origin to be diffusive in nature, and proving the meaningfulness of the facile hydrogen-pump technique for the characterization of the cathode catalyst layer under defined operation conditions.

30 DIRECT ENERGY CONVERSION↗

How to correct relative voxel scale factors for calculations of vector-difference Fourier maps in cryo-EM

The atomic coordinates derived from cryo-electron microscopy (cryo-EM) maps can be inaccurate when the voxel scaling factors are not properly calibrated. Here, we describe a method for correcting relative voxel scaling factors between pairs of cryo-EM maps for the same or similar structures that are expanded or contracted relative to each other. We find that the correction of scaling factors reduces the amplitude differences of Fourier-inverted structure factors from voxel-rescaled maps by up to 20–30%, as shown by two cryo-EM maps of the SARS-CoV-2 spike protein measured at pH 4.0 and pH 8.0. This allows for the calculation of the difference map after properly scaling, revealing differences between the two structures for individual amino acid residues. Unexpectedly, the analysis uncovers two previously overlooked differences of amino acid residues in structures and their local structural changes. Furthermore, we demonstrate the method as applied to two cryo-EM maps of monomeric apo-photosystem II from the cyanobacteria Synechocystis sp. PCC 6803 and Thermosynechococcus elongatus. The resulting difference maps reveal many changes in the peripheral transmembrane PsbX subunit between the two species.

59 BASIC BIOLOGICAL SCIENCES↗

β-particle energy-summing correction for β-delayed proton emission measurements

One common approach to studying β-delayed proton emission is to measure the energy of the emitted proton and corresponding nuclear recoil in a double-sided silicon-strip detector (DSSD) after implanting the β-delayed proton-emitting (βp) nucleus. However, in order to extract the proton-decay energy, the measured energy must be corrected for the additional energy implanted in the DSSD by the β-particle emitted from the βp nucleus, an effect referred to here as β-summing. Here, we present an approach to determine an accurate correction for β-summing. Our method relies on the determination of the mean implantation depth of the βp nucleus within the DSSD by analyzing the shape of the total (proton + recoil + β) decay energy distribution shape. We validate this approach with other mean implantation depth measurement techniques that take advantage of energy deposition within DSSDs upstream and downstream of the implantation DSSD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a deuterium-deuterium neutron generator for the Add-A-Source waste matrix correction technique

Neutron generators offer an alternative to radioactive sources in the application of active techniques for nondestructive assay of nuclear materials. The Add-A-Source technique has enabled improvements in the ability to accurately measure waste bearing nuclear materials by measuring and correcting for the non-nuclear matrix effect. The technique has historically been performed with a Cf-252 spontaneous fission source. Here, in this work, we have demonstrated the use of a Deuterium-deuterium neutron generator in place of the Cf-252 source. A DD generator enables operational advantages and allows the simplification of the instrument design, while offering equivalent corrective performance as a Cf-252 source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Efficiency corrections for factorial moments and cumulants of overlapping sets of particles

In this note we discuss subtleties associated with the efficiency corrections for measurements of off-diagonal cumulants and factorial moments for a situation when one deals with overlapping sets of particles, such as correlations between numbers of protons and positively charged particles. In particular, we discuss the situation commonly encountered in heavy-ion experiments, where first all charges are reconstructed and then protons are selected from these charges by an additional particle identification procedure. We present the efficiency correction formulas for the case when the detection efficiencies follow a binomial distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗