Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

LBNF 1.2 MW Target: Conceptual Design & Fabrication

Fermilab’s Long-Baseline Neutrino Facility (LBNF) will utilize a modified design based on the NuMI low energy target that is reconfigured to accommodate beam operation at 1.2 MW. Achieving this power with a graphite target material and ancillary systems originally rated for 400 kW requires several design changes and R&D efforts related to material bonding and electrical isolation. Target cooling, structural design, and fabrication techniques must address higher stresses and heat loads that will be present during 1.2 MW operation, as the assembly will be subject to cyclic loads and thermal expansion. Mitigations must be balanced against compromises in neutrino yield. Beam monitoring and subsystem instrumentation will be updated and added to ensure confidence in target positioning and monitoring. Remote connection to the target hall support structure must provide for the eventual upgrade to a 2.4 MW target design, without producing excessive radioactive waste or unreasonable exposure to technicians during reconfiguration. Current designs and assembly layouts will be presented, in addition to current findings on processes and possibilities for prototype and final assembly fabrication.

43 PARTICLE ACCELERATORS↗

Evaluation of low heat conductivity rf cables

New potential applications of superconducting radio-frequency can be envisioned with conduction cooling of the cavities using cryocoolers. In this case, the total heat load to the cryocoolers have to be carefully managed to assure sufficient margin to operate the cavity at an acceptable accelerating gradient. The static and dynamic heat load from rf cables connected to the cavity can be a significant contribution to the total heat load. In this contribution we report the results from measurements of the temperature profile at 1.3 GHz for two low heat conductivity rf cables, as a function of the rf power and with one end of the cable in thermal contact with a liquid helium bath at 4.3 K. A parametric model of the two cables was developed with ANSYS to match the temperature profiles and calculate the heat load at the cold end of the cable.

Cheng, G.↗

NRIC Final Water Management Options

The purpose of this paper is to inform advanced reactor developers of the conditions and requirements needed to manage the water used to reject heat from advanced reactor demonstrations at the INL. While there are many advanced reactor concepts, all of them require heat rejection, and some plan to use water for hear rejection. Cooling water for heat rejection is frequently the largest fresh-water load for a nuclear reactor, and therefore the focus of water management. The type of reactor and its purpose, the physical conditions at the INL, and the regulatory structure of the demonstration also influence the optimal method of heat rejection. Choosing the best method of rejecting heat will significantly influence the cost and probability of success for any advanced reactor demonstration. One of the important considerations in the deployment of demonstration plants at the INL site is water use and its implications. Advanced reactor developers need to consider the limitations of the water consumption based on the state and federal regulations. The water consumption may become a limitation when the demonstration reactor capacities reach to conventional nuclear power plants.

99 GENERAL AND MISCELLANEOUS↗

Martensitic transformation induced strength-ductility synergy in additively manufactured maraging 250 steel by thermal history engineering

Maraging steels are known for their exceptional strength but suffer from limited work hardening and ductility. Here, in this study, we report an intermittent printing strategy to tailor the microstructure and mechanical properties of maraging 250 steel via tuning the thermal history during wire-arc directed energy deposition. By introducing a dwell time between adjacent layers, the maraging 250 steel is cooled below the martensite start temperature, triggering thermally-driven martensitic transformation during the printing process. Thermal cycling during subsequent layer deposition results in the formation of reverted austenite which shows a refined microstructure and induces elemental segregation between martensite and reverted austenite. The Ni enrichment in the austenite promotes stabilization of the reverted austenite upon cooling to room temperature. The reverted austenite is metastable during deformation, leading to strain-induced martensitic transformation under loading. Specifically, a 3 min interlayer dwell time produces a maraging 250 steel with approximately 8% reverted austenite, resulting in improved work hardening via martensitic transformation induced plasticity during deformation. Meanwhile, the higher cooling rate and refined prior austenite grains lead to substantially refined martensitic grains (by approximately fivefold) together with an increased dislocation density. With 3 min interlayer dwell time, the yield strength of the printed maraging 250 steel increases from 836 MPa to 990 MPa, and the uniform elongation is doubled from 3.2% to 6.5%. This intermittent deposition strategy demonstrates the potential to tune the microstructure of maraging steels for achieving strength-ductility synergy by engineering the thermal history during additive manufacturing.

Additive manufacturing↗

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Rescue Shuttle Flight Re-Entry: Controlling Astronaut Thermal Exposure

A rescue mission for the STS-125 Hubble Telescope Repair Mission requires reentry from space with 11 crew members aboard, exceeding past cabin thermal load experience and risking crew thermal stress potentially causing cognitive performance and physiological decrements. The space shuttle crew cabin air revitalization system (ARS) was designed to support a nominal crew complement of 4 to 7 crew and 10 persons in emergencies, all in a shirt-sleeve environment. Subsequent to the addition of full pressure suits with individual cooling units, the ARS cannot maintain a stable temperature in the crew cabin during reentry thermal loads. Bulk cabin thermal models, used for rescue mission planning and analysis of crew cabin air, were unable to accurately represent crew workstation values of air flow, carbon dioxide, and heat content for the middeck. Crew temperature models suggested significantly elevated core temperatures. Planning for an STS-400 potential rescue of seven stranded crew utilized computational fluid dynamics (CFD) models to demonstrate inhomogeneous cabin thermal properties and improve analysis compared to bulk models. In the absence of monitoring of crew temperature, heart rate, metabolic rate and incomplete engineering data on the performance of the integrated cooling garment/cooling unit (ICG/CU) at cabin temperatures above 75 degrees F, related systems & models were reevaluated and tests conducted with humans in the loop. Changes to the cabin ventilation, ICU placement, crew reentry suit-donning procedures, Orbiter Program wave-off policy and post-landing power down and crew extraction were adopted. A second CFD and core temperature model incorporated the proposed changes and confirmed satisfactory cabin temperature, improved air distribution, and estimated core temperatures within safe limits. CONCLUSIONS: These changes in equipment, in-flight and post-landing procedures, and policy were implemented for the STS-400 rescue shuttle & will be implemented in any future rescue flights from the International Space Station of stranded shuttle crews.

Gillis, David B.↗

Proton beam power limits for stationary water-cooled tungsten target with different cladding materials

The proton beam power limit for a solid-tungsten spallation target is largely determined by beam induced thermomechanical structural loads and decay heat power deposition, while its lifetime is limited by radiation damage and fatigue life of the target materials. In this paper, we studied the power limits of a stationary water-cooled solid tungsten target concept. Tantalum clad tungsten was considered as a reference case. Being a low activation material, zircaloy 2 cladding option was studied and its decay heat driven power limit was compared with the reference case. Zirconium alloys have proven operations records in spallation target and nuclear fission environments, supported by materials data obtained from post irradiation examinations. Recent study also demonstrated feasibility of diffusion bonding zirconium to tungsten using vanadium foil inter layer. Particle transport simulations code FLUKA was used to calculate energy deposition and decay heat power deposition in the target, based on the beam parameters technically feasible at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory. The energy deposition data were used for flow, thermal, and structural analyses to determine the beam intensity limit on the target concept studied. The decay heat deposition data were used to calculate the transient temperature evolution in the tungsten volumes in a loss of coolant accident (LOCA) scenario to determine its beam power limit. For a 1.3 GeV proton beam, the power limit on a stationary target was 400 kW for a tantalum clad target model and 800 kW for a zircaloy 2 clad target model.

Lee, Yong Joong↗

Cooling the Origins Space Telescope

The NASA Astrophysics Division has commissioned 4 studies for consideration by the 2020 Decadal Survey to be the next flagship mission following WFIRST (Wide Field Infrared Survey Telescope). One of the four studies is the Origins Space Telescope (OST), which will cover wavelengths from 6 microns to 600 microns. To perform at the level of the zodiacal, galactic, and cosmic background, the telescope must be cooled to 4 degrees Kelvin. 4 degrees Kelvin multi-stage mechanical cryocoolers will be employed along with a multilayer sunshield/thermal shield to achieve this temperature with a manageable parasitic heat load. Current state-of-the-art cryocoolers can achieve close to 4 degrees Kelvin, providing about 50 megawatts of cooling at 4 degrees Kelvin with an input power of 500 watts. Multiple coolers at this power level will be used in parallel. These coolers also provide extra cooling power at intermediate temperature stages of 15-20 degrees Kelvin and 50-70 degrees Kelvin . This upper stage cooling will be used to limit the heat conducted to 4 degrees Kelvin . The multi-layer sunshield will limit the radiated thermal energy to the 4 degrees Kelvin volume. This paper will describe the architecture of the cryogenic system for OST along with preliminary thermal models.

cryogenics↗

Experimental studies of transpiration cooling with shock interaction in hypersonic flow, part B

This report describes the result of experimental studies conducted to examine the effects of the impingement of an oblique shock on the flowfield and surface characteristics of a transpiration-cooled wall in turbulent hypersonic flow. The principal objective of this work was to determine whether the interaction between the oblique shock and the low-momentum region of the transpiration-cooled boundary layer created a highly distorted flowfield and resulted in a significant reduction in the cooling effectiveness of the transpiration-cooled surface. As a part of this program, we also sought to determine the effectiveness of transpiration cooling with nitrogen and helium injectants for a wide range of blowing rates under constant-pressure conditions in the absence of shock interaction. This experimental program was conducted in the Calspan 48-Inch Shock Tunnel at nominal Mach numbers of 6 and 8, for a Reynolds number of 7.5 x 10(exp 6). For these test conditions, we obtained fully turbulent boundary layers upstream of the interaction regions over the transpiration-cooled segment of the flat plate. The experimental program was conducted in two phases. In the first phase, we examined the effects of mass-addition level and coolant properties on the cooling effectiveness of transpiration-cooled surfaces in the absence of shock interaction. In the second phase of the program, we examined the effects of oblique shock impingement on the flowfield and surface characteristics of a transpiration-cooled surface. The studies were conducted for a range of shock strengths with nitrogen and helium coolants to examine how the distribution of heat transfer and pressure and the characteristics of the flowfield in the interaction region varied with shock strength and the level of mass addition from the transpiration-cooled section of the model. The effects of the distribution of the blowing rate along the interaction regions were also examined for a range of blowing rates through the transpiration-cooled panels. The regions of shockwave/boundary layer interaction examined in these studies were induced by oblique shocks generated with a sharp, flat plate, inclined to the freestream at angles of 5 degrees, 7.5 degrees, and 10 degrees. It was found that, in the absence of an incident shock, transpiration cooling was a very effective method for reducing both the heat transfer and the skin friction loads on the surface. The helium coolant was found to be significantly more effective than nitrogen, because of its low molecular weight and high specific heat. The studies of shock-wave/transpiration-cooled surface interaction demonstrated that the interaction region between the incident shock and the low-momentum transpiration-cooled boundary layer did not result in a significant increase in the size of attached or separated interaction regions, and did not result in significant flowfield distortions above the interaction region. The increase in heating downstream of the shock-impingement point could easily be reduced to the values without shock impingement by a relatively small increase in the transpiration cooling in this region. Surprisingly, this increase in cooling rate did not result in a significant increase in size of the region ahead of the incident shock or create a significantly enlarged interaction region with a resultant increase in the distortion level in the inviscid flow. Thus, transpiration cooling appears to be a very effective technique to cool the internal surfaces of scramjet engines, where shocks in the engine would induce large local increases in wall heating and create viscous/inviscid interactions that could significantly disturb the smooth flow through the combustor. However, if hydrogen is used as the coolant, burning upstream of shock impingement might result in localized hot spots. Clearly, further research is needed in this area.

Holden, Michael S.↗

Operation of a Heat Pipe with Multiple Heat Loads Under Reflux Mode

"Heat pipes are being used on many spacecraft to acquire heat dissipated by the payload and transport the heat to a remote radiator. In instrument-level or spacecraft-level ground testing, many heat pipes are placed in a gravity-driven reflux mode where the condenser is well above the evaporator, resulting in the formation of a liquid pool at the bottom of the heat pipe. If a head load is applied to a site that is in contact with the liquid pool, the generated vapor will flow upward to the condenser and the condensate will fall back to the evaporator due the influence of gravity. Hence, the heat pipe can operate steadily under reflux mode because the heated site always has sufficient liquid supply to sustain the fluid flow. In contrast, when a heat load is applied to a site remote from the liquid pool, the heat pipe will be unable to transfer heat through liquid evaporation unless the heated site has a chance to be in contact with liquid. This can be accomplished by applying an additional heat load to the liquid pool to establish a reflux flow so that the remote site can capture the falling condensate. An experimental investigation was conducted to study the effect of gravity on the thermal performance of a heat pipe under reflux mode with multiple heat loads. An aluminum ammonia heat pipe with internal axial grooves was placed in a vertical position. Cooling was provided to the top of the heat pipe, and heat was applied to three sites below the condenser with various heat distributions. One of the heated sites was above the liquid pool, and two were in direct contact with the liquid pool. Test results showed that when a heat load was applied to either one or both of the lower sites, the heat pipe could run steadily under reflux mode. After a reflux flow had been established, a heat load could be applied to the upper site. If the upper site could capture sufficient liquid falling from the condenser to handle its heat load solely by liquid evaporation, the heat pipe could reach steady operation. Otherwise, the temperature of the upper site would oscillate due to its intermittent contact with the falling liquid. For a given heat load to the upper site, the amplitude of temperature oscillation decreased with an increasing heat load to the lower sites because there was more falling condensate available for the upper site to capture. Moreover, the temperature oscillation disappeared completely when the total heat loads to lower sites exceeded a threshold power, and the threshold power increased with an increasing heat load to the upper site."

Ku, Jentung↗

Improved turbine disk design to increase reliability of aircraft jet engines

An analytical study was conducted on a bore entry cooled turbine disk for the first stage of the JT8D-17 high pressure turbine which had the potential to improve disk life over existing design. The disk analysis included the consideration of transient and steady state temperature, blade loading, creep, low cycle fatigue, fracture mechanics and manufacturing flaws. The improvement in life of the bore entry cooled turbine disk was determined by comparing it with the existing disk made of both conventional and advanced (Astroloy) disk materials. The improvement in crack initiation life of the Astroloy bore entry cooled disk is 87% and 67% over the existing disk made of Waspaloy and Astroloy, respectively. Improvement in crack propagation life is 124% over the Waspaloy and 465% over the Astroloy disks. The available kinetic energies of disk fragments calculated for the three disks indicate a lower fragment energy level for the bore entry cooled turbine disk.

Alver, A. S.↗

Cooling of the North Atlantic by Saharan Dust

Using aerosol optical depth, sea surface temperature, top-of-the-atmosphere solar radiation flux, and oceanic mixed-layer depth from diverse data sources that include NASA satellites, NCEP reanalysis, in situ observations, as well as long-term dust records from Barbados, we examine the possible relationships between Saharan dust and Atlantic sea surface temperature. Results show that the estimated anomalous cooling pattern of the Atlantic during June 2006 relative to June 2005 due to attenuation of surface solar radiation by Saharan dust remarkably resemble observations, accounting for approximately 30-40% of the observed change in sea surface temperature. Historical data analysis show that there is a robust negative correlation between atmospheric dust loading and Atlantic SST consistent with the notion that increased (decreased) Saharan dust is associated with cooling (warming) of the Atlantic during the early hurricane season (July- August-September).

Lau, K. M.↗

Development of a Prototype Superconducting Radio-Frequency Cavity for Conduction-Cooled Accelerators

Recent progress in the development of high-quality Nb?Sn film coatings along with the availability of cryocoolers with high cooling capacity at 4 K makes it feasible to operate SRF cavities cooled by thermal conduction at relevant accelerating gradients for use in accelerators. We have developed a prototype single-cell cavity to prove the feasibility of operation up to the accelerating gradient required for 1 MeV energy gain, cooled by conduction with cryocoolers. The cavity has a ~3 ¿m thick Nb?Sn film on the inner surface, deposited on a ~4 mm thick bulk Nb substrate and a bulk ~7 mm thick Cu outer shell with three Cu attachment tabs. The cavity was tested up to a peak surface magnetic field of 53 mT in liquid He at 4.3 K. A horizontal test cryostat was designed and built to test the cavity cooled with three cryocoolers. The rf tests of the conduction-cooled cavity achieved a peak surface magnetic field of 50 mT and stable operation was possible with up to 18.5 W of rf heat load. The peak frequency shift due to microphonics was 23 Hz. These results represent the highest peak surface magnetic field achieved in a conduction-cooled SRF cavity to date

Ciovati, Gianluigi↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Advanced waste form and Melter development for treatment of troublesome high-level wastes

A number of waste components in US defense high level radioactive wastes (HLW) have proven challenging for current Joule heated ceramic melter (JHCM) operations and have limited the ability to increase waste loadings beyond already realized levels. Many of these “troublesome" waste species cause crystallization in the glass melt that can negatively impact product quality or have a deleterious effect on melter processing. Recent efforts at US Department of Energy laboratories have focused on understanding crystallization behavior within HLW glass melts and investigating approaches to mitigate the impacts of crystallization so that increases in waste loading can be realized. Advanced glass formulations have been developed to highlight the unique benefits of next-generation melter technologies such as the Cold Crucible Induction Melter (CCIM). Crystal-tolerant HLW glasses have been investigated to allow sparingly soluble components such as chromium to crystallize in the melter but pass out of the melter before accumulating.The Hanford site AZ-101 tank waste composition represents a waste group that is waste loading limited primarily due to high concentrations of Fe 2 O 3 (also with high Al 2 O 3 concentrations). Systematic glass formulation development utilizing slightly higher process temperatures and higher tolerance to spinel crystals demonstrated that an increase in waste loading of more than 20% could be achieved for this waste composition, and by extension higher loadings for wastes in the same group. An extended duration CCIM melter test was conducted on an AZ-101 waste simulant using the CCIM platform at the Idaho National Laboratory (INL). The melter was continually operated for approximately 80 hours demonstrating that the AZ-101 high waste loading glass composition could be readily processed using the CCIM technology. The resulting glass was close to the targeted composition and exhibited excellent durability in both the as poured state and after being slowly cooled according to the canister centerline cooling (CCC) profile. Glass formulation development was also completed on other Hanford tank wastes that were identified to further challenge waste loading due to the presence of appreciable quantities (>750 g) of plutonium in the waste tanks. In addition to containing appreciable Pu quantities, the C-102 waste tank and the 244-TX waste tank contain high concentrations of aluminum and iron, respectively that will further challenge vitrification processing. Glass formulation testing also demonstrated that high waste loadings could be achieved with these tank compositions using the attributes afforded by the CCIM technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Actively cooled airframe structures for high-speed flight

An assessment of forced convectively cooled aircraft structures is presented based on recent and on-going studies. Particular emphasis is given to contractual efforts in which large panels of three different concepts are being designed and fabricated for cyclic thermal-structural tests at the Langley Research Center. Results of ambient temperature fatigue tests of small specimens of these concepts are reviewed. Aspects of conceptual and detail designs, material selection, fabrication, reliability, and heat-load/hydrogen fuel heat-sink matching are discussed. Results to date indicate that active cooling significantly impacts the structural design process, and, despite the use of conventional aluminum materials, advanced complex fabrication processes are required.

Nowak, R. J.↗

Transient Beam Loading Effects in Gas-filled RF Cavities for a Muon Collider

A gas-filled RF cavity can be an effective solution for the development of a compact muon ionization cooling channel. One possible problem expected in this type of cavity is the dissipation of significant RF power through the beam-induced plasmas accumulated inside the cavity (plasma loading). In addition, for the higher muon beam intensity, the effects of the beam itself on the cavity accelerating mode are non-negligible (beam loading). These beam- cavity interactions induce a transient phase which may be very harmful to the beam quality [1]. In this study, we estimate the transient voltage in a gas-filled RF cavity with both the plasma and conventional beam loading and discuss their compensation methods.

43 PARTICLE ACCELERATORS↗