Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Systems and methods for enhanced sequential power system model parameter estimation

A system for enhanced sequential power system model calibration is provided. The system is programmed to store a model of a device. The model includes a plurality of parameters. The system is also programmed to receive a plurality of events associated with the device, receive a first set of calibration values for the plurality of parameters, generate a plurality of sets of calibration values for the plurality of parameters, for each of the plurality of sets of calibration values, analyze a first event of the plurality of events using a corresponding set of calibration values to generate a plurality of updated sets of calibration values, analyze the plurality of updated sets of calibration values to determine a current updated set of calibration values, and update the model to include the current updated set of calibration values.

Wang, Honggang↗

Comparative clumped isotope temperature relationships in freshwater carbonates

Lacustrine, riverine and spring carbonates represent archives of terrestrial climates and their geochemistry has been used to study palaeoenvironments. Clumped isotope thermometry is an emerging tool that has been applied to freshwater carbonates. Limited work has been done to evaluate comparative relationships between clumped isotopes and temperature in different types of modern freshwater carbonates. This study assembles an extensive calibration data set with 135 samples of modern freshwater carbonates from 96 sites and constrains the relationship between independent observations of water temperature and the clumped isotopic composition of carbonates (denoted by Δ 47 ), including new measurements, and recalculates published data in accordance with current community-defined standard values. For temperature reconstruction, the study reports a composite freshwater calibration and material-specific calibrations for biogenic carbonates (freshwater gastropods and bivalves), fine-grained carbonate (e.g. micrites), biologically mediated carbonates (microbialites and tufas) and travertines. Material-specific calibration trends show a convergence of slopes that are in agreement with recently published syntheses, but statistically significant differences in intercepts occur between some materials (e.g. some biogenics, fine-grained carbonates). These differences may arise due to unresolved seasonal biases, kinetic isotope effects and/or varying degrees of biological influence. The impact of different calibrations is shown through application to new data for glacial and deglacial age travertines from Austria and published data sets. While material-specific calibrations may yield more accurate results for biogenic and fine-grained carbonate samples, the use of material-specific and the composite freshwater calibrations generally produces values within 1.0–1.5°C of each other, and typically fall within calibration uncertainty given limitations of precision.

54 ENVIRONMENTAL SCIENCES↗

Bayesian Parameter Estimation of the k-ω Shear Stress Transport Model for Accurate Simulations of Impinging-Jet Heat Transfer

Given the lack of fusion-relevant component test facilities, current estimates of the thermo-fluid performance of plasma-facing components are based for the most part on numerical simulations. A major source of uncertainty in these simulations is the semiempirical turbulence (closure) models for the Reynolds stresses appearing in the governing Reynolds-averaged Navier-Stokes equations, which involve a set of constants that depend upon the flow. The objective of this study is to evaluate Bayesian parameter estimation of turbulence closure constants in ANSYS Fluent to model heat transfer in impinging jets. The Bayesian statistical calibration produces a probability distribution for these constants from experimental data; the maximum a posteriori estimates are then taken to be the calibrated constants, or parameters. The turbulence model constants are calibrated using an experimental study of a submerged jet of air impinging on a flat heated surface at Reynolds numbers Re = O(10 4 ) and impingement distance in jet diameters H/d = 2. Numerical predictions using the calibrated model parameters are then compared with those generated using the default constants. Predictions obtained with model parameters calibrated on datasets of two different sizes are compared to evaluate the effect of the number of calibration samples. Lastly, the extrapolative ability of the calibrated model is examined by predictions at a Re beyond the calibration values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The DESI DR1 Peculiar Velocity Survey: Global Zero-point and H 0 Constraints

The Dark Energy Spectroscopic Instrument (DESI) in its first Data Release (DR1) already provides more than 100,000 galaxies with relative distance measurements. The primary purpose of this paper is to perform the calibration of the zero-point for the DESI Fundamental Plane and Tully–Fisher relations, which allows us to measure the Hubble constant, H 0 . This sample has a lower statistical uncertainty than any previously used to measure H 0 , and we investigate the systematic uncertainties in absolute calibration that could limit the accuracy of that measurement. We improve upon the DESI Early Data Release Fundamental Plane H 0 measurement by (a) using a group catalog to increase the number of calibrator galaxies and (b) investigating alternative calibrators in the nearby Universe. Our baseline measurement calibrates to the SH0ES/Pantheon+ type Ia supernovae, and finds H 0 = 73.7 ± 0.06 (stat.) ± 1.1 (syst.) km s −1 Mpc −1 . Calibrating to surface brightness fluctuation distances yields a similar H 0 . We explore measurements using other calibrators, but these are currently less precise since the overlap with DESI peculiar velocity tracers is much smaller. In future data releases with an even larger peculiar velocity sample, we plan to calibrate directly to Cepheids and the tip of the red giant branch, which will enable the uncertainty to decrease towards a percent-level measurement of H 0 . This will provide an alternative to supernovae as the Hubble flow sample for H 0 measurements.

Carr, Anthony [Korea Astronomy and Space Science I↗

Experimental and theoretical determinations of hydrogen isotopic equilibrium in the system CH 4 —H 2 —H 2 O from 3 to 200°C

The stable isotopic composition of methane (CH 4 ) is commonly used to fingerprint natural gas origins. Over the past 50 years, there have been numerous proposals that both microbial and thermogenic CH 4 can form in or later attain hydrogen isotopic equilibrium with water (H 2 O) and carbon isotopic equilibrium with carbon dioxide (CO 2 ). Evaluation of such proposals requires knowledge of the equilibrium fractionation factors between CH 4 and H 2 O or CO 2 at the temperatures where microbial and thermogenic CH 4 form in or are found in the environment, which is generally less than 200°C. Experimental determinations of these fractionation factors are only available above 200°C, requiring extrapolation of these results beyond the calibrated range or the use of theoretical calculations at lower temperatures. Here, we provide a calibration of the equilibrium hydrogen isotopic fractionation factor for CH 4 and hydrogen gas (H 2 ) ( D α CH4(g)–H2(g) ) based on experiments using γ-Al 2 O 3 and Ni catalysts from 3 to 200°C. Results were regressed as a 2 nd order polynomial of 1000 × ln D α CH4(g)–H2(g) vs. 1/T (K -1 ) yielding: 1000 × l n D α C H 4 ( g ) - H 2 ( g ) = 3.5317 × 10 7 T 2 + 2.7749 × 10 5 T - 179.48 We combine this calibration with previous experimental determinations of hydrogen isotope equilibrium between H 2 , H 2 O(g), and H 2 O(l) and we provide an interpolatable experimental calibration of 1000 × ln D α CH4(g)–H2O(l) from 3 to 200°C. Our resulting 4th order polynomial is the following equation: 1000 × l n D α C H 4 ( g ) - H 2 O l = - 7.9443 × 10 12 T 4 + 8.7772 × 10 10 T 3 - 3.4973 × 10 8 T 2 + 5.4398 × 10 5 T - 382.05 At 3°C, the value from our calibration differs by 93‰ relative to what would be calculated based on the extrapolation of the only experimental calibration currently available to temperatures below its calibrated range (lowest temperature of 200°C; Horibe and Craig, 1995). We additionally provide new theoretical estimates of hydrogen isotopic equilibrium between CH 4 (g), H 2 (g), and H 2 O(g) and carbon isotopic equilibrium between CH 4 (g) and CO 2 (g) using Path Integral Monte Carlo (PIMC) calculations. Our PIMC calculations for hydrogen isotopic equilibrium between CH 4 and H 2 agree 1:1 with our experiments. Finally, we compile carbon and hydrogen isotopic measurements of CH 4 , CO 2 , and H 2 O from various environmental systems and compare observed differences between carbon and hydrogen isotopes to those expected based on isotopic equilibrium. We find that isotopic compositions of some microbial gases from marine sedimentary, coalbed, and shale environments are consistent with those expected for CH 4 H 2 O(l) hydrogen and CH 4 CO 2 carbon isotopic equilibrium. In contrast, microbial terrestrial and pure culture gases are not consistent with both CH 4 H 2 O(l) hydrogen and CH 4 CO 2 carbon isotopic equilibrium. Overall, these results are explained qualitatively using previously developed conceptual models that link free energy gradients available to microorganisms to the degree that their enzymes can promote isotope-exchange reactions between CH 4 , CO 2 , and H 2 O.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uniform Recalibration of Common Spectrophotometry Standard Stars onto the CALSPEC System Using the SuperNova Integral Field Spectrograph

Abstract We calibrate spectrophotometric optical spectra of 32 stars commonly used as standard stars, referenced to 14 stars already on the Hubble Space Telescope–based CALSPEC flux system. Observations of CALSPEC and non-CALSPEC stars were obtained with the SuperNova Integral Field Spectrograph over the wavelength range 3300–9400 Å as calibration for the Nearby Supernova Factory cosmology experiment. In total, this analysis used 4289 standard-star spectra taken on photometric nights. As a modern cosmology analysis, all presubmission methodological decisions were made with the flux scale and external comparison results blinded. The large number of spectra per star allows us to treat the wavelength-by-wavelength calibration for all nights simultaneously with a Bayesian hierarchical model, thereby enabling a consistent treatment of the Type Ia supernova cosmology analysis and the calibration on which it critically relies. We determine the typical per-observation repeatability (median 14 mmag for exposures ≳5 s), the Maunakea atmospheric transmission distribution (median dispersion of 7 mmag with uncertainty 1 mmag), and the scatter internal to our CALSPEC reference stars (median of 8 mmag). We also check our standards against literature filter photometry, finding generally good agreement over the full 12 mag range. Overall, the mean of our system is calibrated to the mean of CALSPEC at the level of ∼3 mmag. With our large number of observations, careful cross-checks, and 14 reference stars, our results are the best calibration yet achieved with an integral-field spectrograph, and among the best calibrated surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Laboratory and field assessment of mid-infrared absorption (MIRA) instrument performance for methane and ethane dry mole fractions

Concurrent measurements of methane (CH 4 ) and ethane (C 2 H 6 ) can be used to identify and separate methane sources, as ethane is present in thermogenic sources (e.g., oil and natural gas) but not in biogenic sources (e.g., agriculture). In this study, we evaluated the performance of multiple Aeris MIRA Ultra instruments (Versions 1 and 2) through controlled laboratory tests and tower-based deployments under field conditions. The systems were modified with an external pump, flow control, a Nafion dryer, and a custom-built auxiliary box to automate the system and transmit near real-time data. We determined the best calibration approach for our application, given practical limitations, to be a full calibration cycle (with ambient and high calibration cylinders) about once per day and an ambient calibration cylinder sampled hourly. Measurement uncertainty was assessed, including the uncertainty due to instrument noise as a function of calibration frequency, uncertainty in the water vapor correction, and cylinder assignment uncertainty. Instrument noise was the dominant source of uncertainty for C 2 H 6 , while the water vapor correction dominated the CH 4 uncertainty. For Version 2 systems with hourly calibrations and a Nafion dryer with counterflow, the mean total uncertainty, including both systematic errors and noise, of hourly averages was 0.8–3.0 ppb CH 4 and 0.35–0.37 ppb C 2 H 6 . Laboratory intercomparisons showed network compatibility within 1.2 ppb CH 4 and 0.23 ppb C 2 H6, and a collocated deployment with a NOAA Picarro system agreed within 1.8 ppb CH 4 . Instrument noise varied substantially amongst the instruments, with errors reaching up to 11 ppb CH 4 and 2 ppb C 2 H 6 for hourly means, with similar variability indicated in a 50 h cylinder test. With appropriate engineering and calibration, the Aeris MIRA Ultra has the potential to distinguish regional methane emission sources in many field settings.

03 NATURAL GAS↗

Breaking the degeneracy between polarization efficiency and cosmological parameters in CMB experiments

Accurate cosmological parameter estimates using polarization data of the cosmic microwave background (CMB) put stringent requirements on map calibration, as highlighted in the recent results from the Planck satellite. In this paper, we point out that a model-dependent determination of polarization calibration can be achieved by the joint fit of the temperature-E-mode cross-power spectrum (TE) and E-mode auto-power spectrum (EE). This provides a valuable cross-check to band-averaged polarization efficiency measurements determined using other approaches. We demonstrate that, in ΛCDM, the combination of the TE and EE constrain polarization calibration with sub-percent uncertainty with Planck data and 2% uncertainty with sptpol data. We arrive at similar conclusions when extending ΛCDM to include the amplitude of lensing A L , the number of relativistic species N eff , or the sum of the neutrino masses Σm ν . Furthermore, the uncertainties on cosmological parameters are minimally impacted when marginalizing over polarization calibration, except, as can be expected, for the uncertainty on the amplitude of the primordial scalar power spectrum ln(10 10 A s ), which increases by 20–50%. However, this information can be fully recovered by adding temperature auto-power spectrum (TT) information. For current and future ground-based experiments, SPT-3G and CMB-S4, we forecast the cosmological parameter uncertainties to be minimally degraded when marginalizing over polarization calibration parameters. In addition, CMB-S4 could constrain its polarization calibration at the level of ~0.2% by combining TE and EE, and reach ~0.06% by also including TT. We therefore conclude that relying on calibrating against Planck polarization maps, whose statistical uncertainty is limited to ~0.5%, would be insufficient for upcoming experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Physiological Controls on Carbon Fluxes and Biomass Production in Miscanthus: Insights From a Process‐Based Agroecosystem Model

Biomass crops serve as essential feedstocks for renewable energy and bioproducts and play a critical role in achieving lower emissions in the transportation sector. However, dedicated perennial biomass crops such as Miscanthus × giganteus (Miscanthus) remain underrepresented in process-based agroecosystem models, limiting robust evaluation of their economic and environmental performance. In this study, we developed a data-constrained representation of the sterile triploid Miscanthus (IL clone) within the process-based model ecosys, integrating global sensitivity analysis, ensemble simulation, and parameter calibration. Planting, harvesting, and fertilization practices consistent with field management were incorporated, and phenology was constrained using PhenoCam-derived Green Chromatic Coordinate (GCC) data. Using the Morris global sensitivity analysis method, we identified 11 key physiological parameters governing plant carbon, water, and nutrient relations, particularly processes associated with CO 2 assimilation. We then conducted ensemble simulations by perturbing these parameters and calibrated the model against eddy covariance fluxes and field-measured biomass. Building on the calibrated operating state, parameter-response analyses show that different photosynthetic processes influence productivity in different ways. Protein allocation determines whether productivity increases toward a higher level, whereas electron transport capacity controls additional gains once protein allocation approaches saturation. These findings demonstrate that parameter importance depends on physiological context and on which photosynthetic processes remain limiting. Calibration and validation against observations show that ecosys can reliably reproduce carbon and water fluxes, as well as both above- and belowground biomass, with post-calibration GPP R 2 improving from 0.67 to 0.95 during the calibration period and remaining high during validation (R 2 = 0.95). These results provide a mechanistic foundation for regional simulations and sustainable bioenergy assessments.

ecosys↗

PV Reference Cells for Outdoor Use: Comparison of First-Year Field Measurements

Reference cells are widely used in the photovoltaic (PV) industry to measure irradiance. For field applications and outdoor use, a variety of products are on the market, and they are often perceived as low-cost alternatives to thermopile pyranometers. But reference cell characteristics, such as directional and spectral response, fundamentally differ from pyranometers, and measurements made by the former cannot be substituted for or directly compared with the latter. The National Renewable Energy Laboratory's (NREL's) Solar Radiation Research Laboratory is currently in a multiyear effort to develop guidance and recommendations for the design and use of outdoor reference cells, with a view to reducing inconsistencies and measurement uncertainty. The core of this effort is the long-term deployment of multiple products from different manufacturers that are mounted at a fixed tilt, on a single-axis tracker, and on a dual-axis tracker. This report provides an analysis of the data collected during the first year of operation at the NREL location. An overall assessment is made by comparing the total energy measured by each instrument to the other instruments having the same orientation. These totals are calculated for three different scenarios: (1) using the factory calibration factors, (2) using the previously determined NREL Cell Lab calibration factors, and (3) using the newly determined field calibration factors derived from the recorded measurements. Because the true or correct measurement values are unknown, pair-wise comparisons are made. The results show that the difference between the highest and lowest measured energy can exceed 3% when using the factory calibration factors. Consistency among instruments improves when Cell Lab calibrations are used, and it further improves when using field calibration factors.

14 SOLAR ENERGY↗

Report Series: Finding of Effect and Mitigation Documentation for Building 23-153, Mercury, Area 23, Nevada National Security Site, Nye County, Nevada

Finding of Effect: The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) plans to demolish Building 23-153, the Mechanical Calibration Laboratory (Calibration Lab), in Mercury (Nevada State Historic Preservation Office [SHPO] Resource No. B15271), which is on the Nevada National Security Site (NNSS) in Nye County, Nevada. The purpose of the undertaking is related to the modernization of Mercury for future mission needs. The NNSA/NFO will implement this undertaking in accordance with the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA. Building 23-153 was constructed in Mercury in 1982 as the Mechanical Calibration Laboratory and served as a support facility for nuclear testing throughout the last decade of the Cold War. The town of Mercury and the immediate surrounding area have been formally determined eligible for listing in the National Register of Historic Places (NRHP) as the Mercury Historic District (MHD, SHPO Resource No. D230) under Criteria A and C for their importance in supporting nuclear testing and scientific research from 1951 through 1992. Building 23-153 was identified as a contributing element to the MHD in a 2018 architectural survey of the district (Reno et al. 2018) and recorded on a Nevada Architectural Resource Assessment (ARA) form (Reno et al. 2017). Building 23-153 was also identified in Appendix C of the Mercury PA as a Category II contributing element. Category II properties are those that have several representatives in the MHD but may possess different engineering or architectural characteristics that distinguish them from other classes of similar elements. Building 23-153 is a historic property for the purposes of compliance with Section 106 of the National Historic Preservation Act (NHPA) and subject to the stipulations of the Mercury PA. Mitigation: The purpose of this letter report is to submit documentation related to the mitigation of the demolition of Building 23-153, the Mechanical Calibration Laboratory (Calibration Lab, Nevada State Historic Preservation Office [SHPO] Resource No. B15271), in the Mercury Historic District (MHD, SHPO Resource No. D230) at the Nevada National Security Site (NNSS) in Nye County, Nevada. The Calibration Lab is considered contributing to the significance of the district both for its historic importance in relation to nuclear testing under Criterion A and as a part of the distinctive design and construction of the district under Criterion C. This submission is intended to comply with the stipulations in the Programmatic Agreement between the National Nuclear Security Administration Nevada Field Office and the Nevada State Historic Preservation Officer Regarding Modernization and Operational Maintenance of the Nevada National Security Site, at Mercury in Nye County, Nevada, hereafter referred to as the Mercury PA.

54 ENVIRONMENTAL SCIENCES↗

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗

SYMBA: An end-to-end VLBI synthetic data generation pipeline

Realistic synthetic observations of theoretical source models are essential for our understanding of real observational data. In using synthetic data, one can verify the extent to which source parameters can be recovered and evaluate how various data corruption effects can be calibrated. These studies are the most important when proposing observations of new sources, in the characterization of the capabilities of new or upgraded instruments, and when verifying model-based theoretical predictions in a direct comparison with observational data. We present the SYnthetic Measurement creator for long Baseline Arrays (SYMBA), a novel synthetic data generation pipeline for Very Long Baseline Interferometry (VLBI) observations. SYMBA takes into account several realistic atmospheric, instrumental, and calibration effects. Here, we used SYMBA to create synthetic observations for the Event Horizon Telescope (EHT), a millimetre VLBI array, which has recently captured the first image of a black hole shadow. After testing SYMBA with simple source and corruption models, we study the importance of including all corruption and calibration effects, compared to the addition of thermal noise only. Using synthetic data based on two example general relativistic magnetohydrodynamics (GRMHD) model images of M 87, we performed case studies to assess the image quality that can be obtained with the current and future EHT array for different weather conditions. Our synthetic observations show that the effects of atmospheric and instrumental corruptions on the measured visibilities are significant. Despite these effects, we demonstrate how the overall structure of our GRMHD source models can be recovered robustly with the EHT2017 array after performing calibration steps, which include fringe fitting, a priori amplitude and network calibration, and self-calibration. With the planned addition of new stations to the EHT array in the coming years, images could be reconstructed with higher angular resolution and dynamic range. In our case study, these improvements allowed for a distinction between a thermal and a non-thermal GRMHD model based on salient features in reconstructed images.

79 ASTRONOMY AND ASTROPHYSICS↗

ZTF-SEDm Type Ia supernova sample for Twins Embedding spectrophotometric standardization

Aims. This paper has two aims: the first aim is to build a large homogeneous spectrophotometric sample of Type Ia supernovae (SNe Ia) from the second data release of the Zwicky Transient Facility (ZTF DR2). We used the spectrum sample from the low-resolution ( R ∼ 100) SEDmachine (SEDm) Integral Field Spectrograph (IFS) that gathered 3069 spectra. This is one of the largest samples of such collections that can attempt to reproduce the Twins Embedding (TE) spectrophotometric standardization method. This is our second objective. The method was developed based on high-quality spectra from 200 SNe Ia of the Nearby Supernova factory (SNfactory) and led to an exceptionally low value of 0.073 mag for the intrinsic scatter. Methods. As the SEDm is not designed as a spectrophotometric instrument, we first improved the flux-calibration accuracy of the SN Ia spectrum sample using the ZTF photometric data, which were calibrated at the percent level. We corrected the spectra for second-order polynomials, fitted by comparing the synthetic photometry in the ZTF g , r , i filters with the light-curve (LC) data. We then applied the three steps of the TE parameterization to a subset of 783 ZTF SN spectra near maximum light while comparing results from SNfactory and ZTF. We finally analyzed the standardization methods based on the TE parameters. Results. The precision of the phase-correction model, which is the first step of the TE, is estimated at 0.01 mag in g band based on ZTF data. Despite the challenge posed by the spectrum-extraction pipeline associated with the SEDm (flux calibration, leftover host signal, low signal-to-noise ratio, and low resolution), we applied a first standardization in color based on the second step of the TE, called read between the lines (RBTL), to the ZTF sample. We reached a Hubble residual scatter of 0.153 mag, all in normalized median absolute deviation, which is to be compared to the ∼0.11 mag obtained with the SNfactory data. The SALT color and stretch standardization reaches a scatter of 0.164 mag for the same ZTF SN Ia sample, and its host steps are ∼0.1 mag and zero for RBTL. When considering the scatter due to the redshift error and flux calibration error, we estimated a RBTL scatter of ∼0.129 mag for this ZTF sample as an upper limit because we identified an additional contribution from a systematic error in color. We tested the standardization based on the nonlinear TE parameters, and, as expected from the low spectrum quality, it did not improve the overall dispersion. Conclusions. We release 1897 flux calibrated spectra of 1607 SNe Ia with an estimated photometric accuracy of 0.07 mag. We further demonstrate that some amount of spectrophotometric SN Ia standardization can be done with limited-quality spectra. The RBTL standardization is more efficient than that of SALT with one parameter less, and the resulting host steps are consistent with zero. This makes it less prone to astrophysical bias. For future spectroscopic surveys, targeting the extraction pipeline for a thorough flux calibration and good signal-to-noise ratio would enable us to compute the full TE standardization, which would further reduce the scatter in the distance estimate.

Ganot, C↗

Uncertainty Quantification for a Multi-phase Carbon Equation of State Model

Many physics models have tunable parameters that are calibrated by matching the model output to experimental or calculated data. However, given that calibration data often contain uncertainty and that different model parameter sets might result in a very similar simulated output for a finite calibration data set, it is advantageous to provide an ensemble of parameter sets that are consistent with the calibration data. Uncertainty quantification (UQ) provides a means to generate such an ensemble in a statistically rigorous fashion. In this work, we perform UQ for a multi-phase equation of state (EOS) model for carbon containing the diamond, graphite, and liquid phases. We use a Bayesian framework for the UQ and introduce a novel strategy for including phase diagram information in the calibration. The method is highly general and accurately reproduces the calibration data without any material-specific prior knowledge of the EOS model parameters.

36 MATERIALS SCIENCE↗

Simultaneous inference of equation of state parameters and unknown data errors with uncertainty quantification via hierarchical Bayesian posterior maximization

Equations of state (EOSs) are a key component in running hydrodynamic simulations as they relate the thermodynamic states for the material. The Davis reactants EOS is commonly used for modeling high explosives (HEs), and the EOS model parameters are calibrated using material specific data. The calibrations are often performed with uncertainty quantification via Bayesian inference to account for uncertainty in the data and generate ensembles of likely parameters. However, there are relatively few HE data sets to use for calibration and many are historical and lack error information. In this work, we simultaneously calibrate the Davis reactants EOS model parameters and unknown data error terms for the high explosive PBX 9501. To quantify the uncertainty in the models and the data, we use a Bayesian framework for the calibration and compute the hierarchical Bayesian posterior distribution with both a posteriori maximization approach and Markov Chain Monte Carlo. In general, we find that, given our assumptions, the two approaches result in similar calibrated parameters, posterior covariance matrices, and insights about the parameters but that the posterior maximization requires far less computational resources.

97 MATHEMATICS AND COMPUTING↗

Reliable Power Rating of Perovskite PV Modules

As the perovskite technology is ramping up into commercialization, reliable and accurate power rating of large-size perovskite modules becomes a prominent aspect for its future deployment in the PV market. It is known that the performance calibration of perovskite PV devices is very challenging due to its complex dynamic response during a conventional current-voltage (IV) measurement. PV researchers have previously proposed several steady-state performance calibration methods to reliably extract PV efficiencies, but mostly focus on small area research-type cells. In this paper, we emphasize the importance of reliable performance calibration on large-size perovskite modules. Extending the NREL Cell and Module Performance (CMP) group's steady-state performance calibration protocol (i.e., Asymptotic P MAX Scan) for perovskite cells to modules, we justify the necessity of reporting steady-state efficiencies for perovskite cells and discuss the challenges of applying this protocol to modules. We also present our protocol for Maximum Power Point Tracking (MPPT), which is a technique often used for performance calibration of perovskite cells and modules, and show a comparison between MPPT and Asymptotic P MAX . Using MPPT we demonstrate the interplay between metastability and degradation in perovskite modules, and emphasize the necessity to develop preconditioning protocols for stabilizing these devices. Our aim is to promote development of consensus protocols for performance calibration of perovskite modules, and to advance their credible power ratings, which will be beneficial to the growth of perovskite technology in the PV market.

perovskite↗