Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “buildings efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Effect of rice husk ash-derived activator on the structural build-up of alkali activated materials

Highlights: • Filtered and unfiltered sodium silicate solutions were synthesised from RHA. • The dissolution efficiency of RHA in NaOH solution was 76.3%. • RHA-derived activator showed a structural build-up comparable to the commercial activator in AAM pastes. • The undissolved residues in the unfiltered RHA-derived activator increased the yield stress. • Comparable compressive strength and early age gel formation were observed from both commercial and RHA-derived solutions. Waste-derived sodium silicates (SSs) were synthesised from rice husk ash (RHA) to produce alkali activated materials (AAMs) using fly ash and slag as precursors. The effects of these SSs on the structural build-up were investigated by monitoring the evolution of the viscoelasticity, ultrasonic pulse waves, setting time, and infrared spectra. Two types of RHA derived SSs (filtered SS and unfiltered SS) were prepared to investigate the effect of the undissolved residue on the hardening process. The derived SS contained a large portion of monomer silicate species. The results showed that the structural build-up mechanism was comparable between the AAMs activated by the filtered SS and a commercial SS. The unfiltered SS increased the yield stress of the paste by up to 10 times. However, the residues in the unfiltered SS had insignificant impacts on the gel formation and compressive strength when using identical SiO{sub 2}/Na{sub 2}O and Na{sub 2}O/binder ratios in the mix design.

36 MATERIALS SCIENCE↗

Assay-based background projection for the Majorana Demonstrator using Monte Carlo uncertainty propagation

The background index (BI) is an important quantity to project and calculate the half-life sensitivity of neutrinoless double-𝛽 decay (0⁢𝜈⁢𝛽⁢𝛽) experiments. An analysis framework is presented to calculate the BI using the specific activities, masses, and simulated efficiencies of an experiments components as distributions. This Bayesian framework includes a unified approach to combine specific activities from assay. Monte Carlo uncertainty propagation is used to build a BI distribution from the specific activity, mass, and efficiency distributions. This method is applied to the M AJORANA D EMONSTRATOR , which deployed arrays of high-purity Ge detectors enriched in 76 Ge to search for 0⁢𝜈⁢𝛽⁢𝛽. The original assay-based projection is requantified in the new framework, using the as-built geometry of the Demonstrator and additional assay information. While 47% higher than the original projection, the resulting BI of [8.95±0.36]×10 −4 cts/(keVkgyr) from the 232 Th and 238 U decay chains does not account for the higher-than-expected BI observed by the D EMONSTRATOR . Finally, this method enables us to demonstrate the statistical incompatibility between the D EMONSTRATOR 's observed background and the assay results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

REBOUND: Reverse Engineering Bidirectional Outflow Under Non-Equilibrium Diffusion

Rare-earth elements (REEs) are essential for electronics, renewable energy, and defense technologies. However, the current supply of REEs relies on mining concentrated in a few countries and energy-intensive separations. DOE’s Basic Energy Sciences (BES) program has launched a grand challenge which aims to ensure a sustainable supply of critical REEs by developing innovative and environmentally friendly separation methods. As an alternative to costly and harmful traditional methods, the Non-Equilibrium Transport Driven Separations (NETS) initiative has created a microfluidic Y-channel co-flow method that applies external fields to exploit magneto- and electrohydrodynamic effects for separating dilute REE ions from complex feedstocks. Computational fluid dynamics (CFD) studies have identified a few operating conditions with promising ion selectivity and separation efficiency. However, challenges remain regarding Y-channel versatility across feedstocks and accurate incorporation of physical phenomena into CFD models. In this work, we develop a multi-fidelity modelling approach which integrates experimental results with CFD simulation to build a surrogate model for the dependence of separation efficiency to variation of design parameters. The surrogate model enables a reinforcement learning (RL) method to adaptively launch CFD and experimental runs, improving model fidelity around optimal Y-channel parameters.

36 MATERIALS SCIENCE↗

Meeting Building Energy Performance Standards at The Westory

The Westory office building used Washington, DC's Building Energy Performance Standard as an impetus for energy efficiency improvements and certification with the assistance of Cushman & Wakefield's Energy & Sustainability Services.

Energy Performance Standards, Energy Audit, ENERGY↗

Design of toroidal transformers for maximum efficiency

The design of the most efficient toroidal transformer that can be built given the frequency, volt-ampere rating, magnetic flux density, window fill factor, and materials is described. With the above all held constant and only the dimensions of the magnetic core varied, the most efficient design occurs when the copper losses equal 60 percent of the iron losses. When this criterion is followed, efficiency is only slightly dependent on design frequency and fill factor. The ratios of inside diameter to outside diameter and height to build of the magnetic core that result in transformers of maximum efficiency are computed.

Dayton, J. A., Jr.↗

Advanced Stirling Convertor (ASC) Technology Maturation in Preparation for Flight

The Advanced Stirling Convertor (ASC) is being developed by an integrated team of Sunpower and National Aeronautics and Space Administration s (NASA s) Glenn Research Center (GRC). The ASC development, funded by NASA s Science Mission Directorate, started as a technology development effort in 2003 and has since evolved through progressive convertor builds and successful testing to demonstrate high conversion efficiency, low mass, and capability to meet long-life Radioisotope Power System (RPS) requirements. The technology has been adopted by the Department of Energy and Lockheed Martin Space Systems Company s Advanced Stirling Radioisotope Generator (ASRG), which has been selected for potential flight demonstration on Discovery 12. This paper provides an overview of the status of ASC development including the most recent ASC-E2 convertors that have been delivered to GRC and an introduction to the ASC-E3 and ASC flight convertors that Sunpower will build next. The paper also describes the technology maturation and support tasks being conducted at GRC to support ASC and ASRG development in the areas of convertor and generator extended operation, high-temperature materials, heater head life assessment, organics, nondestructive inspection, spring fatigue testing, and other reliability verification tasks.

Wong, Wayne A.↗

3D Reality Energy Modeling Software

The team will combine Bentley Systems’ ContextCapture and extend Oak Ridge National Laboratory’s building energy modeling capabilities in order to create digital twins of buildings that allow simulation-informed improvement for energy efficiency and demand response in the design and operation of the built environment. Bentley Systems’ ContextCapture software processes data from 3D laser scanning and photographs (through photogrammetry) to create a photorealistic, 3D mesh with a scale of individual objects to building to city-sized. This capability easily provides city-level visualization models and platforms where sustainable design alternatives are readily evaluated. Oak Ridge National Laboratory (ORNL) serves the U.S. Dept. of Energy (DOE) as one of three core laboratories developing building energy modeling tools EnergyPlus and OpenStudio. ORNL’s AutoBEM software (bit.ly/AutoBEM) can process imagery (satellite, aerial, and street level), LiDAR, cartographic layers, tax assessor’s data, and other data sources to extract building footprints, height, window-to-wall ratio, building type, vintage, and other building properties. AutoBEM has created 178,368 building energy models that were empirically validated with 15-minute whole-building electrical data from a utility.

97 MATHEMATICS AND COMPUTING↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Transforming Energy through Sustainable Mobility: Expanding Energy-Efficient Mobility Options

As the nation's premier facility for energy-efficient transportation research and development solutions, NREL blazes new trails with a whole-system approach that combines vehicle, building, and infrastructure connectivity and automation to optimize mobility and increase energy efficiency. NREL also explores new options for high-performance engines to maximize energy efficiency and on-road vehicle performance, while minimizing emissions, enhancing energy security, increasing U.S. jobs, and lowering drivers' costs.

ADVANCED PROPULSION SYSTEMS,DIRECT ENERGY CONVERSI↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preparing large area of thermochromic nanocomposite films for smart window application

The challenges posed by high building energy bill necessitate proactive implementation of energy-efficient strategies to minimize the uses of both electricity and heating gas and promote the use of free solar energy sources. "Smart" window films/glass, leveraging thermochromic vanadium dioxide (VO 2 ), offer an adaptive approach to harness solar energy, significantly reducing the thermal load of buildings. This is achieved by reflecting the infrared portion of the solar spectrum through a phase transition in the monoclinic M-phase (M) of VO 2 induced by heating. In this study, a scalable continuous flow synthesis process invented by Argonne was employed to explore a wide parameter space, targeting the controlled synthesis of monoclinic VO 2 (M) nanoparticles with well-controlled sizes and morphologies. Additionally, a doping strategy and surface modifications were utilized for high-throughput tuning of the metal-to-insulator transition temperature. Strategies to enhance the solar modulation properties of VO 2 nanoparticles in polymer films were investigated through (i) morphological transformation from spherical to nanorod structures, (ii) surface modification with low refractive index ligands, and (iii) incorporation of additional thermochromic materials for improved solar energy modulation and aesthetically appealing colors in smart films. Furthermore, the study outlines scaling-up synthesis methods for VO 2 nanoparticles in a continuous flow reactor using hydrazine monohydrate. This comprehensive investigation provides valuable insights into the upscaling synthesis and design of advanced VO 2 /polymer composite smart window films with enhanced functionality, solar energy modulation and visible light transmittance, driving the technology a step close for industrial application.

14 SOLAR ENERGY↗

High-Performance Integrated Window and Façade Solutions for California

The researchers developed a new generation of high-performance façade systems and supporting design and management tools to support industry in meeting California’s greenhouse gas reduction targets, reduce energy consumption, and enable an adaptable response to minimize real-time demands on the electricity grid. The project resulted in five outcomes: (1) The research team developed an R-5, 1-inch thick, triplepane, insulating glass unit with a novel low-conductance aluminum frame. This technology can help significantly reduce residential cooling and heating loads, particularly during the evening. (2) The team developed a prototype of a windowintegrated local ventilation and energy recovery device that provides clean, dry fresh air through the façade with minimal energy requirements. (3) A daylight-redirecting louver system was prototyped to redirect sunlight 15–40 feet from the window. Simulations estimated that lighting energy use could be reduced by 35–54 percent without glare. (4) A control system incorporating physics-based equations and a mathematical solver was prototyped and field tested to demonstrate feasibility. Simulations estimated that total electricity costs could be reduced by 9-28 percent on sunny summer days through adaptive control of operable shading and daylighting components and the thermostat compared to state-of-the-art automatic façade controls in commercial building perimeter zones. (5) Supporting models and tools needed by industry for technology R&D and market transformation activities were validated. Attaining California’s clean energy goals require making a fundamental shift from today’s ad-hoc assemblages of static components to turnkey, intelligent, responsive, integrated building façade systems. These systems offered significant reductions in energy use, peak demand, and operating cost in California.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Aniak Energy Efficiency Retrofit Project

The Native Village of Aniak (NVA) is a remote Yup’ik community in western Alaska. NVA is proposing to install energy efficiency measures in the Tribal Office, Community Center, Association of Village Council Presidents (AVCP) Office, and Duplex. The goal of the project is to reduce the overall energy use of the NVA by implementing energy efficiency measures in four high-use tribal buildings. This project expects to have the following outcomes: projected annual energy savings of approximately $24,238; projected annual reduction in fuel oil of roughly 1,802 gallons and electricity of around 24,537 kWh; and annual reduction in carbon dioxide emissions of approximately 84,594 pounds/year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating Energy Efficiency Strategies with Industrialized Construction for Our Clean Energy Future: Preprint

NREL’s Industrialized Construction Innovation Team has developed an ambitious plan to accelerate the integration of energy efficiency (EE) strategies with Industrialized Construction (IC). The United States (U.S.) construction industry is beginning to use IC methods to build multifamily apartment buildings to address affordability and labor shortages. Apart from reducing cost of construction and delivery times, the IC method of permanent modular construction has the potential to facilitate the integration of a wide range of EE strategies and advanced controls into such buildings. While there may be unintended EE benefits to IC such as a tighter envelope due to higher construction quality, the process has not been leveraged specifically to enhance EE. NREL aims to claim this missed opportunity and integrate IC benefits with EE as well as advanced controls, distributed energy resources, and grid-friendly design strategies. The paper proposes an ‘IC Assessment Framework’ to achieve affordable zero-energy modular multifamily buildings. Through the selection criteria of Design for Manufacturing and Assembly, the framework aims to distill a broad range of proven EE strategies for site-built into a set of strategies that qualify as easy to integrate for off-site. The output is a Factory Information Model (FIM) that represents a process-based digital twin to enable advanced time-and-motion study, plugs into open source building energy modeling platform (EnergyPlus), and serves as a vital tool facilitating wider adoption of EE integration. Conclusively, the paper delineates next steps for upcoming pilots with NREL’s IC partners towards developing a transformational pathway for our Clean Energy Future.

30 DIRECT ENERGY CONVERSION↗

Pushing Green: Leveraging Home Energy Score to Promote Deep-Energy Retrofits in Portland, Oregon

In the United States, 39% of total energy is consumed by the building sector, 20% of which is attributed to residential buildings. Older homes, built before 1992 when the U.S. Department of Energy’s (DOE) Building Energy Codes Program was established, represent approximately 68% of residential building stock in the country and often have significant air leakage, inadequate insulation and inefficient heating & cooling systems. These older homes have long been the elephant in the room: how can programs effectively increase efficiency in all of the homes in need? Developed by DOE, the Home Energy Score was established to provide homeowners, buyers, and renters a comparable score measuring a home's energy use. Much like the MPG rating of automobiles, the Home Energy Score provides an overview of a residential building’s energy efficiency. In 2016, the City of Portland passed an ordinance requiring all residential properties to receive a Home Energy Score before being listed for sale, a mandate that was implemented January 1, 2018. Since 2018, more than 22,000 homes throughout the Portland Metro area have received Home Energy Scores (amounting to over 10% of Portland's single-family homes). This paper explores the sample of Home Energy Scores throughout Portland, including at the neighborhood level, identifies trends in efficiency measures, describes how the data has been used to date and proposes ways program administrators can use the Home Energy Score to increase the impact of energy efficiency programs on a city-scale.

Antonopoulos, Chrissi A.↗