Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Electron lenses for particle collimation in LHC

Electron Lenses built and installed in Tevatron have proven themselves as safe and very reliable instruments which can be effectively used in hadron collider operation for a number of applications, including compensation of beam-beam effects [1], DC beam removal from abort gaps [2], as a diagnostic tool. In this presentation we - following original proposal [3] - consider in more detail a possibility of using electron lenses with hollow electron beam for ion and proton collimation in LHC.

43 PARTICLE ACCELERATORS↗

A wire calorimeter for the SPIDER beam: Experimental tests and feasibility study

To study and optimize negative ion production and acceleration, in view of the use of neutral beam injectors in the ITER project, the SPIDER test facility (particle energy 100keV; beam current 50A, distributed over 1280 beamlets) is under construction in Padova, with the aim of testing beam characteristics and to verify the source proper operation, by means of several diagnostic systems. An array of tungsten wires, directly exposed to the beam and consequently heated to high temperature, is used in similar experiments at IPP-Garching to study the beam optics, which is one of the most important issues, in a qualitative way. The present contribution gives a description of an experimental investigation of the behavior of tungsten wires under high heat loads in vacuum. Samples of tungsten wires are heated by electrical currents and the emitted light is measured by a camera in the 400-1100nm wavelength range, which is proposed as a calibration tool. Simultaneously, the voltage applied to the wire is measured to study the dependency of emissivity on temperature. The feasibility study of a wire calorimeter for SPIDER is finally proposed; to this purpose, the expected behaviour of tungsten with the two-dimensional beam profile in SPIDER is numerically addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An ion optics study for KSTAR neutral beam injector development

Ion optics of three accelerator geometries was studied in terms of an analytic linear optics analysis, a numerical simulation using the IGUN program, an optical multichannel measurement of Doppler-shifted H{sub {alpha}} lines, and a water-flow calorimetry on the beam absorbing target. In general, there was a reasonable agreement observed between the four analysis methods and thus the theoretical analyses can be utilized with confidence for design iteration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron emission generated during wire array Z-pinch implosion onto deuterated fiber

The implosion of both cylindrical and conical wire arrays onto a deuterated polyethylene fiber was studied on the S-300 pulsed power generator [A. S. Chernenko et al., Proceedings of the 11th International Conference on High Power Particle Beams (Academy of Science of Czech Republic, Prague, 1996), p. 154]. Neutron measurements were used to obtain information about acceleration of fast deuterons. An average neutron yield approached 10{sup 9} on the current level of 2 MA. In the case of conical wire arrays, side-on neutron energy spectra peaked at 2.48{+-}0.05 MeV with 450{+-}100 keV full width at half-maximum. In the downstream direction, the peak neutron energy and the width of a neutron spectrum were 2.65{+-}0.10 MeV and 350{+-}100 keV, respectively. The total number of fast deuterons was 10{sup 15} and their average kinetic energy was about 150 keV. Most of the deuterons were directed toward the cathode. The broad width of neutron spectra in the side-on direction implied a high radial component of deuteron velocity. With regard to the emission time, neutron pulses temporally correlated with hard x rays and also with measured voltage. The neutron emission lasted on average 30{+-}5 ns and it was observed during the stagnation and at the beginning of the expansion of a plasma column. At this moment, the plasma impedance reached 0.2-0.4 {omega}. In the post-stagnation phase, this value was formed significantly by enhanced plasma resistance. Similar experimental results were observed also with cylindrical wire arrays imploding onto a deuterated fiber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a He{sup 0} Source for Confined Alpha Particle Measurement

A probing He{sup 0} beam for confined alpha particle measurement using a double charge exchange process is now under development. A proof of principle experiment for ground-state He{sup 0} beam production will be performed on a test stand. Several methods are developed to measure the metastable fraction of a He{sup 0} beam. A full-size strong-focusing He{sup +} source has been constructed and sufficient beam current was achieved with a beam size tolerable to be used on ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of the HIBP Diagnostic for Uragan-2M Stellarator

The applicability of the HIBP diagnostics for the URAGAN-2M stellarator is described in this article. It is possible to use such diagnostics for local plasma electric field potential measurements. The necessary voltages on the primary ion beam accelerator, energy analyzer and deflecting plates are acceptable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The effect of rf pulse pattern on bremsstrahlung and ion current time evolution of an ECRIS

Time-resolved helium ion production and bremsstrahlung emission from JYFL 14 GHz ECRIS is presented with different radio frequency pulse lengths. rf on times are varied from 5 to 50 ms and rf off times from 10 to 1000 ms between different measurement sets. It is observed that the plasma breakdown occurs a few milliseconds after launching the rf power into the plasma chamber, and in the beginning of the rf pulses a preglow transient is seen. During this transient the ion beam currents are increased by several factors compared to a steady state situation. By adjusting the rf pulse separation the maximum ion beam currents can be maintained during the so-called preglow regime while the amount of bremsstrahlung radiation is significantly decreased.

43 PARTICLE ACCELERATORS↗

High-Charge, Multi-MeV Electron Bunches Accelerated in Moderate Laser-Plasma Interaction Regime

Experiments, and simulations have shown that quasi-monoenergetic electron bunches can be accelerated from the background electron plasma population up to relativistic energies. Theoretical work indicated that with a proper choice of laser, plasma, and injection parameters the acceleration of electron bunches with small energy spread and short bunch length can occur in moderate intensity regime. Here we present the results of an experiment on electron acceleration carried out at the IPCF-CNR's Intense Laser Irradiation Laboratory in Pisa, within a wide national collaboration leaded by INFN named PLASMONX. High-charge, multi-MeV electron bunches were accelerated in moderated intensity regime by focusing the laser beam on a laminar gaseous target produced by a supersonic gas-jet. The laser-gas interaction was studied via interferometry, and Thomson scattering while the electron bunches were detected and characterised using a phosphor screen coupled with a magnetic spectrometer or a dosimetric detector. In some cases highly collimated electron bunches with moderate energy spread were observed, while the generation of high-charge, MeV energies electron bunches were obtained with high reproducibility for each gases tested.

43 PARTICLE ACCELERATORS↗

Effect of collisional quenching on the measurement of ion species mix in neutral beam injectors

A corona model is used in analyzing the Doppler shifted spectroscopy (DSS) data for estimating the ion species mix and beam species fractions in positive ion based neutral beam injectors. In this model the excited neutral atom is assumed to decay solely by a spontaneous radiative process. However, at the beam energies of 20-60 keV/amu, collisional quenching of the excited neutrals affects these estimations when background pressure exceeds 1 mTorr. We present here a modified corona model that takes into account the effects of collisional quenching. We also describe the results of application of the present model to a typical DSS data obtained in the first phase of operation of the SST-1 neutral beam injector.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new Scanning Transmission X-ray Microscope at the ALS for operation up to 2500eV

We report on the design and construction of a higher energy Scanning Transmission X-ray Microscope on a new bend magnet beam line at the Advanced Light Source. Previously we have operated such an instrument on a bend magnet for C, N and O 1s NEXAFS spectroscopy. The new instrument will have similar performance at higher energies up to and including the S 1s edge at 2472eV. A new microscope configuration is planned. A more open geometry will allow a fluorescence detector to count emitted photons from the front surface of the sample. There will be a capability for zone plate scanning in addition to the more conventional sample scanning mode. This will add the capability for imaging a massive sample at high resolution over a limited field of view, so that heavy reaction cells may be used to study processes in-situ, exploiting the longer photon attenuation length and the longer zone plate working distances available at higher photon energy. The energy range will extend down to include the C1s edge at 300eV, to allow high energy NEXAFS microscopic studies to correlate with the imaging of organics in the same sample region of interest.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Four-dimensional imaging of the initial stage of fast evolving plasmas

Using an ultrafast electron probe capable of four-dimensional diagnosis, the initial stage of fast evolving plasmas produced by a 10{sup 14} W/cm{sup 2} laser irradiation of a metal target was investigated in real time with picosecond time resolution. The associated strong transient electric field was identified to have two components, which either focus or defocus the probe electron beam. The effects of this field on the probe electron beam can be reproduced by a self-expanding charge cloud containing about 5x10{sup 7} suprathermal electrons with the outermost layer expanding at an average speed of 1.2x10{sup 7} m/s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of Phase Objects by Using an X-ray Microscope with a Foucault Knife-Edge

An x-ray microscope with a zone plate was assembled at the synchrotron radiation source of BL3C, Photon Factory. A Foucault knife-edge was set at the back focal plate of the objective zone plate and phase retrieval was tested by scanning the knife-edge. A preliminary result shows that scanning the knife-edge during exposure was effective for phase retrieval. Phase-contrast tomography was investigated using differential projection images calculated from two Schlieren images with the oppositely oriented knife-edges. Fairly good reconstruction images of polystyrene beads and spores could be obtained.

43 PARTICLE ACCELERATORS↗

Comparison of Optical Emission Spectroscopy and Cavity Ring-Down Spectroscopy in Large-Scaled Negative-Ion Source

Optical emission spectroscopy (OES) and cavity ring-down spectroscopy (CRDS) systems are installed in a 1/3-scaled negative hydrogen-ion source at the National Institute for Fusion Science testbed to investigate the dynamics of H{sup -} ions in the extraction region near the plasma grid. The signal form of the H{sup -} ion density rapidly drops after beam extraction on applying a low-bias voltage. A similar signal drop appears in the intensity of the hydrogen Balmer-line emission measured by OES and is caused by decreasing atomic hydrogen produced by mutual neutralization effects between H{sup -} and H{sup +}. Shot trend of the beam currents are similar to the H{sup -} density and H{sub {alpha}}/H{sub {beta}} in the extraction region, which increases twice as large immediately after Cs seeding. We observe a linear correlation between the H{sup -} density and the inclination of H{sub {alpha}}/H{sub {beta}} which allows for experimentally benchmarking the OES measurement with that of CRDS. Thus, this approach is used for estimating the H{sup -} density by OES in negative-ion sources for high-energy neutral beam injector.

43 PARTICLE ACCELERATORS↗

Experimental Investigation of Laser-sustained Plasma in Supersonic Argon Flow

Laser-induced energy deposition is widely discussed as a flow control technique in supersonic transportation. In case of thermal laser-plasma upstream of a blunt body, a substantial adaptation of shock wave geometry and magnitude of wave drag is predicted. Related to the research on laser supported detonation, the paper describes the implementation of laser-sustained plasma in a supersonic Argon jet. The stable plasma state is generated by the intersection of a Q-switched Nd:YAG-laser and a continuous wave CO{sub 2}-laser beams, for ignition and maintenance of the plasma respectively. A miniature supersonic Ludwieg tube test facility generates a supersonic jet at velocities of Mach 2.1. Modifications of the flow and plasma conditions are investigated and characterized by Schlieren flow visualisation, laser energy transmission and plasma radiation measurements. The results include the discussions of the flow field as well as the required laser and gas parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal and electrostatic simulations of the diagnostic calorimeter for the Source for Production of Ion of Deuterium Extracted from RF plasma beam

To study and optimise negative ion production for the ITER neutral beam injectors, a test facility is under construction in Padova with the aim of testing beam characteristics and to verify the source proper operation. The instrumented calorimeter STRIKE (short-time retractable instrumented kalorimeter experiment) is being developed to characterise the SPIDER (Source for Production of Ion of Deuterium Extracted from RF plasma) beam during short operations. The paper presents an investigation of the response of STRIKE measurement systems. It results that biasing is necessary to cope with the influence of secondary electrons on current measurements; moreover, despite the discretisation of the recorded thermal patterns introduced by the pixels of thermal cameras, a sufficient spatial resolution is expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A photodiode-based neutral particle bolometer for characterizing charge-exchanged fast-ion behavior

A neutral particle bolometer (NPB) has been designed and implemented on Tri Alpha Energy's C-2 device in order to spatially and temporally resolve the charge-exchange losses of fast-ion populations originating from neutral beam injection into field-reversed configuration plasmas. This instrument employs a silicon photodiode as the detection device with an integrated tungsten filter coating to reduce sensitivity to light radiation. Here we discuss the technical aspects and calibration of the NPB, and report typical NPB measurement results of wall recycling effects on fast-ion losses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial measurements of fast ion loss in KSTAR

A fast ion loss detector (FILD) has been installed and tested in Korea Superconducting Tokamak Advanced Research (KSTAR). KSTAR FILD measures the energy and the pitch-angle of the escaping ions with the striking positions on the scintillator plane. Measurements of the fast ion loss have been performed for the neutral beam heated plasmas. Initial experimental results indicate the prompt losses from neutral beam are dominant and the effects of the resonant magnetic perturbation on the fast ion loss are investigated. In addition, further design change of the detector-head in order to avoid excessive heat load and to detect the fusion products or the fast ions having order of MeV of energy is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high spatial resolution Stokes polarimeter for motional Stark effect imaging

We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗