Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Multicriteria optimization informed VMAT planning

We developed a patient-specific volumetric-modulated arc therapy (VMAT) optimization procedure using dose-volume histogram (DVH) information from multicriteria optimization (MCO) of intensity-modulated radiotherapy (IMRT) plans. The study included 10 patients with prostate cancer undergoing standard fractionation treatment, 10 patients with prostate cancer undergoing hypofractionation treatment, and 5 patients with head/neck cancer. MCO-IMRT plans using 20 and 7 treatment fields were generated for each patient on the RayStation treatment planning system (clinical version 2.5, RaySearch Laboratories, Stockholm, Sweden). The resulting DVH of the 20-field MCO-IMRT plan for each patient was used as the reference DVH, and the extracted point values of the resulting DVH of the MCO-IMRT plan were used as objectives and constraints for VMAT optimization. Weights of objectives or constraints of VMAT optimization or both were further tuned to generate the best match with the reference DVH of the MCO-IMRT plan. The final optimal VMAT plan quality was evaluated by comparison with MCO-IMRT plans based on homogeneity index, conformity number of planning target volume, and organ at risk sparing. The influence of gantry spacing, arc number, and delivery time on VMAT plan quality for different tumor sites was also evaluated. The resulting VMAT plan quality essentially matched the 20-field MCO-IMRT plan but with a shorter delivery time and less monitor units. VMAT plan quality of head/neck cancer cases improved using dual arcs whereas prostate cases did not. VMAT plan quality was improved by fine gantry spacing of 2 for the head/neck cancer cases and the hypofractionation-treated prostate cancer cases but not for the standard fractionation–treated prostate cancer cases. MCO-informed VMAT optimization is a useful and valuable way to generate patient-specific optimal VMAT plans, though modification of the weights of objectives or constraints extracted from resulting DVH of MCO-IMRT or both is necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A linear method for analyzing lightning field changes

A constrained, least-squares method for analyzing multiple-station measurements of lightning field changes (delta Es) is introduced. Previous methods have attempted to fit the spatial pattern of lightning delta Es using nonlinear models, such as a point charge (Q) or a point dipole (P) model. With the linear method, the delta Es are described not by models but by a general volume charge distribution that is deposited on a large (40 x 40 x 20 cu km) Cartesian grid above the measuring network. A linear system of equations is used to relate the measured delta Es to the charges that are deposited at each grid point. With this approach, the information content of the measurements can be quantified by an eigenanalysis of the covariance matrix of the linear system. Constraints can be used to reduce the infinity of possible solutions to the linear system and also to reduce systematic biases that can be introduced by the method of solution. It is shown that a Landweber iterative method, derived from the general method of steepest descent, can be used to solve the linear system and that the resulting volume charge distributions are generally consistent with computer-simulated charge sources, when these sources are over the measuring network. The Landweber iteration has also provided solutions for natural lightning events that are consistent with Q- and P-model results.

Koshak, William J.↗

NASTRAN thermal analyzer: Theory and application including a guide to modeling engineering problems, volume 2

A sample problem library containing 20 problems covering most facets of Nastran Thermal Analyzer modeling is presented. Areas discussed include radiative interchange, arbitrary nonlinear loads, transient temperature and steady-state structural plots, temperature-dependent conductivities, simulated multi-layer insulation, and constraint techniques. The use of the major control options and important DMAP alters is demonstrated.

Jackson, C. E., Jr.↗

GFiRe—Gauge Field integrator for Reheating

We present a new numerical algorithm and code, GFiRe, for solving the nonlinear evolution of Abelian gauge fields coupled to complex scalar fields in homogeneous and isotropic spacetimes. We adopt a hybrid approach to solving the system: the spatial derivatives are discretized using standard Lattice Gauge Field Theory techniques, whereas the time evolution of the fields and scale factor is implemented with explicit, composite, symplectic integrators. An important property of our compound algorithm is that the discretized Gauss constraint is respected exactly, regardless of the order of the symplectic integrator. This remains true even when the background expansion is computed “self-consistently”; that is, when the expansion history is computed using spatial averaged components of the energy momentum tensor in the simulation volume. Hence, our code can also be used in cases where the fields dominate the energy density of the universe, for example, during reheating after inflation. We test the algorithm in scenarios of reheating where the inflaton is a complex scalar field with a potential ∝(2|Φ| 2 - v 2 ) 2 and is coupled to an Abelian gauge field. Tracing the evolution of the system through complex dynamics (including resonant excitation of fields, backreaction, formation of solitons, and changes in the equation of state) in a self-consistently expanding universe, we find the energy conservation violation (<10 -4 ) to be very stable and the Gauss constraint violation (<10 -6 ) to be dominated by differencing noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics-Informed Machine Learning Model for Ceramic Matrix Composite Creep

A physics-informed recurrent neural network (RNN) based surrogate model is developed to emulate the nonlinear, time-dependent constitutive behavior of ceramic matrix composites (CMCs) driven by matrix damage and constituent creep at the microscale. Physics-informed constraints are introduced into the surrogate model through regularization to ground the prediction in physics and improve its predictive capabilities. Training data is generated using the high-fidelity generalized method of cells (HFGMC) approach which calls appropriate creep and damage models for each of the constituents. This coupling permits simulating the nonlinear behavior of CMCs based on constituent response at the microscale along with microstructural features such as fiber and porosity volume fraction and fiber radius. The microscale repeating unit cell is loaded under creep fatigue conditions to replicate the material loading experienced in a turbine engine. Therefore, the RNN-based surrogate model is tasked with predicting, as a function of variable input stress sequence, temperature, and microstructural features, the resulting strain history response while satisfying physical constraints related to creep rate, isochoric inelastic deformation, and strain energy density. The trained surrogate model is shown to effectively match the strain history over quantified distributions of microstructural features and relevant loading regimes and temperatures. Neural network based surrogate models can offer efficient alternatives to running computationally intensive multiscale material models to simulate the nonlinear response of large structural models. Therefore, the presented work provides evidence towards the feasibility of developing, training, and running such models for CMCs with complex microstructures, nonlinear time-dependent material response, and under non-monotonic loading conditions.

ceramic matrix composites↗

Spine Radiosurgery: A Dosimetric Analysis in 124 Patients Who Received 18 Gy

Purpose: To define the safely tolerated doses to organs at risk (OARs) adjacent to the target volume (TV) of spine radiosurgery (SRS) with 18-Gy in a single fraction. Methods and Materials: A total of 124 patient cases with 165 spine metastases were reviewed. An 18-Gy single-fraction regimen was prescribed to the 90% isodose line encompassing the TV. A constraint of 10 Gy to 10% of the spinal cord outlined 6 mm above and below the TV was used. Dosimetric data to OARs were analyzed. Results: A total of 124 patients (100%) were followed-up, and median follow-up time was 7 months (1-50 months). Symptoms and local control were achieved in 114 patients (92%). Acute Radiation Therapy Oncology Group (RTOG) grade 1 oral mucositis occurred in 11 of 11 (100%) patients at risk for oropharyngeal toxicity after cervical spine treatment. There were no RTOG grade 2-4 acute or late complications. Median TV was 43.2 cc (5.3-175.4 cc) and 90% of the TV received median dose of 19 Gy (17-19.8 Gy). Median (range) of spinal cord maximum dose (Dmax), dose to spinal cord 0.35 cc (Dsc0.35), and cord volume receiving 10 Gy (Vsc10) were 13.8 Gy (5.4-21 Gy), 8.9 Gy (2.6-11.4 Gy) and 0.33 cc (0-1.6 cc), respectively. Other OARs were evaluated when in proximity to the TV. Esophagus (n=58), trachea (n=28), oropharynx (n=11), and kidneys (n=34) received median (range) V10 and V15 of 3.1 cc (0-5.8 cc) and 1.2 cc (0-2.9 cc), 2.8 cc (0-4.9 cc), and 0.8 cc (0-2.1 cc), 3.4 cc (0-6.2 cc) and 1.6 cc (0-3.2 cc), 0.3 cc (0-0.8 cc) and 0.08 cc (0-0.1 cc), respectively. Conclusions: Cord Dmax of 14 Gy and D0.35 of 10 Gy are safe dose constraints for 18-Gy single-fraction SRS. Esophagus V10 of 3 cc and V15 of 1 cc, trachea V10 of 3 cc, and V15 of 1 cc, oropharynx V10 of 3.5 cc and V15 of 1.5 cc, kidney V10 of 0.3 cc, and V15 of 0.1 cc are planning guidelines when these OARs are in proximity to the TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dependence of Achievable Plan Quality on Treatment Technique and Planning Goal Refinement: A Head-and-Neck Intensity Modulated Radiation Therapy Application

Purpose: To develop a practical workflow for retrospectively analyzing target and normal tissue dose–volume endpoints for various intensity modulated radiation therapy (IMRT) delivery techniques; to develop technique-specific planning goals to improve plan consistency and quality when feasible. Methods and Materials: A total of 165 consecutive head-and-neck patients from our patient registry were selected and retrospectively analyzed. All IMRT plans were generated using the same dose–volume guidelines for TomoTherapy (Tomo, Accuray), TrueBeam (TB, Varian) using fixed-field IMRT (TB-IMRT) or RAPIDARC (TB-RAPIDARC), or Siemens Oncor (Siemens-IMRT, Siemens). A MATLAB-based dose–volume extraction and analysis tool was developed to export dosimetric endpoints for each patient. With a fair stratification of patient cohort, the variation of achieved dosimetric endpoints was analyzed among different treatment techniques. Upon identification of statistically significant variations, technique-specific planning goals were derived from dynamically accumulated institutional data. Results: Retrospective analysis showed that although all techniques yielded comparable target coverage, the doses to the critical structures differed. The maximum cord doses were 34.1 ± 2.6, 42.7 ± 2.1, 43.3 ± 2.0, and 45.1 ± 1.6 Gy for Tomo, TB-IMRT, TB-RAPIDARC, and Siemens-IMRT plans, respectively. Analyses of variance showed significant differences for the maximum cord doses but no significant differences for other selected structures among the investigated IMRT delivery techniques. Subsequently, a refined technique-specific dose–volume guideline for maximum cord dose was derived at a confidence level of 95%. The dosimetric plans that failed the refined technique-specific planning goals were reoptimized according to the refined constraints. We observed better cord sparing with minimal variations for the target coverage and other organ at risk sparing for the Tomo cases, and higher parotid doses for C-arm linear accelerator–based IMRT and RAPIDARC plans. Conclusion: Patient registry–based processes allowed easy and systematic dosimetric assessment of treatment plan quality and consistency. Our analysis revealed the dependence of certain dosimetric endpoints on the treatment techniques. Technique-specific refinement of planning goals may lead to improvement in plan consistency and plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Compact turnkey focussing neutron guide system for inelastic scattering investigations

We demonstrate the performance of a compact neutron guide module which boosts the intensity in inelastic neutron scattering experiments by approximately a factor of 40. The module consists of two housings containing truly curved elliptic focussing guide elements, positioned before and after the sample. The advantage of the module lies in the ease with which it may be reproducibly mounted on a spectrometer within a few hours, on the same timescale as conventional sample environments. It is particularly well suited for samples with a volume of a few mm{sup 3}, thus enabling the investigation of materials which to date would have been considered prohibitively small or samples exposed to extreme environments, where there are space constraints. We benchmark the excellent performance of the module by measurements of the structural and magnetic excitations in single crystals of model systems. In particular, we report the phonon dispersion in the simple element lead. We also determine the magnon dispersion in the spinel ZnCr{sub 2}Se{sub 4} (V = 12.5 mm{sup 3}), where strong magnetic diffuse scattering at low temperatures evolves into distinct helical order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutrino constraints on inelastic dark matter captured in the Sun

Abstract The flux of neutrinos from annihilation of gravitationally captured dark matter in the Sun has significant constraints from direct-detection experiments. However, these constraints are relaxed for inelastic dark matter as inelastic dark matter interactions generate less energetic nuclear recoils compared to elastic dark matter interactions. In this paper, we explore the possibility for large volume underground neutrino experiments to detect the neutrino flux from captured inelastic dark matter in the Sun. The neutrino spectrum has two components: a mono-energetic “spike” from pion and kaon decays at rest and a broad-spectrum “shoulder” from prompt primary meson decays. We focus on detecting the shoulder neutrinos from annihilation of hadrophilic inelastic dark matter with masses in the range 4–100 GeV and the mass splittings in up to 300 keV. We determine the event selection criterion for DUNE to identify GeV-scale muon neutrinos and anti-neutrinos originating from hadrophilic dark matter annihilation in the Sun, and forecast the sensitivity from contained events. We also map the current bounds from Super-Kamiokande and IceCube on elastic dark matter, as well as the projected limits from Hyper-Kamiokande, to the parameter space of inelastic dark matter. We find that there is a region of parameter space that these neutrino experiments are more sensitive to than the direct-detection experiments. For dark matter annihilation to heavy-quarks, the projected sensitivity of DUNE is weaker than current (future) Super (Hyper) Kamiokande experiments. However, for the light-quark channel, only the spike is observable and DUNE will be the most sensitive experiment.

Astronomy & Astrophysics↗

Satellite Test Assistant Robot (STAR)

A three-year, three-phase program to demonstrate the applicability of telerobotic technology to the testing of satellites and other spacecraft has been initiated. Specifically, the objectives are to design, fabricate, and install into the JPL 25-ft. Space Simulator (SS) a system that will provide the capability to view test articles from all directions in both the visible and infrared (IR) spectral regions, to automatically map the solar flux intensity over the entire work volume of the chamber, and to provide the capability for leak detection. The first year's work, which provides a vertically mobile viewing platform equipped with stereo cameras, will be discussed. Design constraints and system implementation approaches mandated by the requirements of thermal vacuum operation will be emphasized.

Mcaffee, D. A.↗

Development of an analytical transient evacuation model for the fairing jettison process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

Fairing depressurization↗

Development of an analytical transient evacuation model for the fairing jettison process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

fairing depressurization↗

Development of an Analytical Transient Evacuation Model for the Fairing Jettison Process

A general, lumped-parameter, control volume equation is developed to describe the rapid loss of pressure associated with a launch vehicle fairing jettison event in its initial phase. Beginning with a general mass conservation statement, a sonic constraint is applied to the expanding gap between receding fairing halves to produce a statement for transient density. This is related to fairing pressure by assuming the expansion may be described by a polytropic process. A generic, single-step, lateral fairing half separation case is created and explored for illustrative purposes.

fairing depressurization, jettison, venting↗

Gravitational Inferences on Lunar Igneous History Beyond Mare Volcanism

The source, distribution, and volume of igneous material on the Moon sheds light into its thermal evolution. Previous work has focused on extrusive mare volcanism, but intrusions and non-mare compositions are equally as important. Constraints on the ratio of magma production to volcanic output (intrusive/extrusive ratio) inform mantle melting rates and the conditions that allowed transport of magma through the crust. Additionally, the lithological diversity of lunar volcanic products sheds light on the timeline of lunar cooling and fracturing of the crust.

K Izquierdo↗

A Novel Dose Constraint to Reduce Xerostomia in Head-and-Neck Cancer Patients Treated With Intensity-Modulated Radiotherapy

Purpose: To investigate the predictors of incidence and duration of xerostomia (XT) based on parotid glands (PG), submandibular glands (SMG), and both glands taken as a whole organ (TG) in head-and-neck cancer patients treated with intensity-modulated radiotherapy. Methods and Materials: A prospective study was initiated in May 2003. Sixty-three head-and-neck patients (44 with nasopharynx cancer) were included in the analysis. Using the dose-volume histogram the PG, SMG, and TG mean doses were calculated. Unstimulated and stimulated salivary flow were measured and XT-related questionnaires were compiled before and at 3, 6, 12, 18, and 24 months after radiotherapy. Salivary gland toxicity was evaluated using the Radiation Therapy Oncology Group scale, and Grade >=3 toxicity was used as the endpoint. The XT incidence was investigated according to descriptive statistics and univariate and multivariate analysis. The Bonferroni method was used for multiple comparison adjustment. Results: After a reduced flow at 3 months after radiotherapy, recovery of salivary flow was observed over time. Primary site and salivary gland mean doses and volumes were identified in univariate analysis as prognostic factors. Multivariate analysis confirmed that TG mean dose (p = 0.00066) and pretreatment stimulated salivary flow (p = 0.00420) are independent factors for predicting XT. Conclusion: The TG mean dose correlates with XT as assessed by Radiation Therapy Oncology Group criteria, salivary output, and XT-related questionnaires. Our results suggest that TG mean dose is a candidate dose constraint for reducing XT, requiring considerably more validation in non-nasopharyngeal cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Considering computational speed vs. accuracy: Choosing appropriate mesoscale RVE boundary conditions

Modeling a material’s microstructure using continuum theories allows for inspection of the relationship between coarse scale and fine scale behaviors. Computational limits generally require selection of a sub-volume from a bulk sample in order to directly model the microstructure. Boundary conditions are applied to the sub-volume to mimic the excluded bulk material. Appropriate selection of boundary conditions helps effectively determine the appropriate spatial scale required of the sub-volume. Applicable boundary conditions include direct displacement, periodic, and uniform traction. While direct displacement and periodic boundary conditions are commonly used, uniform traction boundary conditions have seen limited use due to rigid body stability issues in simulations of compression or shear deformation. A new application of uniform traction boundary conditions was developed through linear constraint equations, similar to approaches employed by direct displacement and periodic boundary conditions, to quench rigid body motions with minimal interference of the relative deformation of the model. These boundary conditions were tested by compressing several synthetically generated periodic microstructures using the finite element method. Evaluating the effective stiffness along the compression axis, the direct displacement boundary condition produced the stiffest response, whereas the uniform traction boundary condition produced the most compliant. Periodic boundary conditions produced the same response for all volumes analyzed and both the direct displacement and uniform traction boundary conditions trended toward the periodic response as the domain volume increased. Computational performance was also evaluated for each boundary condition using implicit and explicit solvers. Direct displacement boundary conditions presented the lowest computational cost of all of the boundary conditions followed by periodic then uniform traction. The computational expense of periodic and uniform traction boundary conditions limited the viable spatial scale and mesh resolutions able to be simulated. Selection of appropriate boundary conditions for specific uses need to be a balance between allowable computational expense and accuracy of the method. Techniques for evaluating which boundary conditions to use are discussed.

42 ENGINEERING↗