Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Reinforcement Learning-Based Secondary Control Strategy for Voltage and Frequency Regulation in Islanded Inverter-Based Microgrids

This paper presents a reinforcement learning (RL) approach for secondary voltage and frequency control in islanded inverter-based microgrids. The proposed control strategy aims to restore voltage and frequency deviations caused by the primary droop control while ensuring proper power sharing between distributed generators. The RL agent is designed to provide correction signals to the primary control, considering communication delays and system constraints. The effectiveness of the proposed control strategy is validated through simulation results in MATLAB/Simulink environment, demonstrating superior performance in maintaining voltage and frequency within the nominal values.

Rodriguez Martinez, Omar Felipe [University of Pue↗

Coordination of Energy Storage and Distributed Generation for Voltage Control and Peak-valley Filling

The increasing penetration of distributed energy resources (DERs) in distribution network (DN) poses challenges on voltage control. In addition, the growing integration of DERs also reshapes the traditional load profile. To comprehensively address the voltage control and peak-valley filling in DN, this paper proposes a model predictive control (MPC) based optimization framework. The proposed method can achieve coordinated voltage control and peak-valley filling by adjusting the reactive power output from distributed generations (DGs) and the charging/discharging of energy storage systems (ESS). The performance of the proposed method is demonstrated by simulations on a modified IEEE-123 bus system.

Zhang, Zhengfa [University of Tennessee, Knoxville↗

Effects of Voltage-Bias Annealing on Metastable Defect Populations in CIGS and CZTSe Solar Cells

We report on voltage-bias annealing (VBA) experiments performed on CIGS and CZTSe solar cells. In these experiments, completed devices were annealed at moderate temperatures and subsequently quenched with continuously applied voltage bias. These treatments resulted in substantial reversible changes in device characteristics. Photovoltaic (PV) conversion efficiency of the CIGS device varied from below 3% to above 15%, with corresponding changes in CIGS hole density from ~1014 cm-3 to ~1017 cm-3. In the CZTSe device, open-circuit voltage varied from 289 meV to 446 meV, caused by an approximately factor of fifty change in the CZTSe hole density. We interpret these findings in terms of reversible changes to the metastable point-defect populations that control key properties in these materials. Implications for optimization of PV materials and connections to long-term stability of PV devices are discussed.

14 SOLAR ENERGY↗

Admittance Spectroscopy in CZTSSe: Metastability Behavior and Voltage Dependent Defect Study

Admittance spectroscopy has been performed on a CZTSSe device with a carrier injection pretreatment and under electronically relaxed conditions to demonstrate metastability behavior. We show that the measurements with the carrier injection pretreatment demonstrate two admittance signatures while the relaxed measurement demonstrates only one admittance signature with a different activation energy. Additionally, voltage dependent admittance spectroscopy was performed using the carrier injection pretreatment method at each of the applied voltage bias. The activation energies of the two admittance signatures were calculated and are shown to be independent of the voltage bias.

14 SOLAR ENERGY↗

The Development of a DC Breakdown Voltage Test for Photovoltaic Insulating Materials

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for PV technology. Direct current breakdown voltage is therefore now specified for relied-upon insulator materials in the IEC 61730-1 safety standard. To fulfill that requirement, a new test method has been developed within the IEC TS 62788-2 backsheet standard for the measurement of breakdown voltage. The development of the test will be described, including the verification of the most critical parameters relative to factors such as defect population(s), dielectric medium, electrode size, electrode surface roughness, maximum current limit, moisture conditioning, number of replicate specimens, rate of voltage rise, specimen thickness, test polarity, and test temperature. Many of these parameters were specifically explored in discovery experiments as the test method was developed. An interlaboratory round-robin (R-R) experiment was conducted to further validate the test method by quantifying its repeatability and reproducibility. The materials examined in the R-R include the backsheet materials: polyethylene terephthalate (PET, two thicknesses), polyvinyl fluoride (PVF), and laminated PVF/PET/PVF ('TPT') as well as the encapsulants poly(ethylene-co-vinyl acetate) (EVA), and polyvinyl butyral (PVB). The precision of the test method as well as key factors contributing to the measurement will be described.

14 SOLAR ENERGY↗

Extremum seeking-based optimization of high voltage converter modulator rise-time

We digitally implement an extremum seeking (ES) algorithm, which optimizes the rise time of the output voltage of a high voltage converter modulator (HVCM) at the Los Alamos Neutron Science Center (LANSCE) HVCM test stand by iteratively, simultaneously tuning the first 8 switching edges of each of the three phase drive waveforms (24 variables total). We achieve a 50 μs rise time, which is reduction in half compared to the 100 μs achieved at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. Considering that HVCMs typically operate with an output voltage of 100 kV, with a 60Hz repetition rate, the 50 μs rise time reduction will result in very significant energy savings. The ES algorithm will prove successful, despite the noisy measurements and cost calculations, confirming the theoretical results that the algorithm is not affected by noise whose frequency components are independent of the perturbing frequencies.

43 PARTICLE ACCELERATORS↗

Large Angle Deviation in Grid-Following IBRs Upon Grid Voltage Dip

In the 2021 Texas Odessa large-scale solar PV tripping events, phase-locked-loop (PLL) loss of synchronism is identified as a major cause of solar PV tripping. When solar PVs detected a large phase angle deviation (e.g., 10 degrees), tripping commands were initiated. Here, the large phase angle deviation was triggered by a transmission line fault 200 miles away, which in turn led to approximately 30% voltage drop in the 345-kV system. This paper offers a plausible reason why grid-following inverter-based resources (IBRs) may experience a large angle deviation upon grid voltage dip. Critical operating conditions contributing to such phenomena are identified via analysis and their effects are demonstrated using electromagnetic transient (EMT) simulation. Furthermore, the effect of converter control, e.g., grid-following control vs. grid-forming control, is examined. It is found from EMT simulation results that frequency and voltage control are helpful in mitigating angle deviation. Furthermore, linear block diagrams are derived to examine why frequency control can effectively suppress large angle deviation.

14 SOLAR ENERGY↗

A Megawatt-Scale Medium-Voltage High-Efficiency High Power Density “SiC+Si” Hybrid Three-Level ANPC Inverter for Aircraft Hybrid-Electric Propulsion Systems

A hybrid-electric propulsion system is an enabling technology to make the aircraft more fuel saving, quieter, and lower carbide emission. In this article, a megawatt (MW) scale power inverter based on a three-level active neutral-point-clamped (3L-ANPC) topology will be developed. To achieve high efficiency, the switching devices operating at carrier frequency in the power converter are configured by the emerging silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors, while the conventional silicon (Si) insulated-gate bipolar transistors are selected for switches operating at the fundamental output frequency. To obtain high power density, dc bus voltage is increased from the conventional 270 V to medium voltage of 2.4 kV to reduce cable weight. Also, unlike the traditional 400 Hz dominated aircraft ac systems, the rated fundamental output frequency here is boosted to 1.4 kHz to drive the high-speed motor, which helps further to reduce the motor weight. Main hardware development and control modulation strategies are presented. Experimental findings are presented to verify the performance of this MW-scale medium-voltage “SiC+Si” hybrid 3L-ANPC inverter. It is shown that the 1-MW 3L-ANPC inverter can achieve a high efficiency of 99% and a high power density of 12 kVA/kg.

42 ENGINEERING↗

Virtual Self-Excited Induction Generator-Based Grid-Forming Inverter Control for Robust Voltage Regulation Under Nonideal Loading

This paper presents a generator-inspired control methodology for grid-forming (GFM) inverters that deliberately emulates a self-excited induction generator so that the inverter can hold its voltage and frequency under difficult loading and severe terminal disturbances across wide voltage and frequency ranges. The design integrates a Lyapunov energy function-based inner loop to provide high bandwidth and strong disturbance rejection, and it complements this with a passivity-based argument that furnishes a coherent large-signal stability guarantee beyond small-signal limits. Analytical insights are developed via the Krylov-Bogoliubov-Mitropolsky averaging method, which reveals an intrinsic resistive droop characteristic; these closed-form relations both explain the observed dynamics and yield simple, decentralized tuning rules. The methodology is validated on a controller-hardware-in-the-loop platform and exercised in real time across balanced, unbalanced, and nonlinear loads, as well as during parallel operation. Across these scenarios, the inverter maintains balanced three-phase voltages, limits harmonic content, settles quickly with well-damped transients, and remains resilient when multiple units operate in parallel. The contributions are a self-excited-machine-inspired GFM controller with enhanced dynamic performance and robustness, a single stability rationale grounded in passivity, closed-form expressions that guide tuning, and comprehensive hardware-in-the-loop validations demonstrating effectiveness and superiority under challenging operating conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Agent Graph-Attention Deep Reinforcement Learning for Post-Contingency Grid Emergency Voltage Control

Grid emergency voltage control (GEVC) is paramount in electric power systems to improve voltage stability and prevent cascading outages and blackouts in case of contingencies. While most deep reinforcement learning (DRL)-based paradigms perform single agents in a static environment, real-world agents for GEVC are expected to cooperate in a dynamically shifting grid. Moreover, due to high uncertainties from combinatory natures of various contingencies and load consumption, along with the complexity of dynamic grid operation, the data efficiency and control performance of the existing DRL-based methods are challenged. To address these limitations, we propose a multi-agent graph-attention (GATT)-based DRL algorithm for GEVC in multi-area power systems. Here, we develop graph convolutional network (GCN)-based agents for feature representation of the graph-structured voltages to improve the decision accuracy in a data-efficient manner. Furthermore, a cutting-edge attention mechanism concentrates on effective information sharing among multiple agents, synergizing different-sized subnetworks in the grid for cooperative learning. We address several key challenges in the existing DRL-based GEVC approaches, including low scalability and poor stability against high uncertainties. Test results in the IEEE benchmark system verify the advantages of the proposed method over several recent multi-agent DRL-based algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

Guest Editorial Special Section on Advanced Medium-Voltage Power Electronics for Grid Interactive Applications

Medium-voltage power electronics (MVPE) plays essential roles in power grid modernization and links the MV distribution grid with low-voltage consumers and prosumers. Various MVPE devices, such as solid-state transformers or circuit breakers, inverter-based resources, power flow controllers, etc., bring the benefits of voltage conversion and power regulation in small footprint, power quality and efficiency improvements, and enhancements of grid controllability, flexibility, stability, and resilience. The MVPE also makes it possible for sustainable energy systems, such as solar/wind farms and energy storage generating facilities, to directly access to MV grids without multistage conversions. With their intrinsic intelligence and communications, MVPE enables many new smart grid functions and applications, e.g., dc interconnections and electric vehicle charging, which were not envisioned by traditional power grids otherwise. In addition, the integration of physical power processing units with cyber components forms a cyber-physical system, which is essential for long-term sustainability, development, and environmental preservation. Nonetheless, technical challenges on MVPE device reliability, scalable and efficient converter topologies, control stability, large-scale modeling and simulation, to name a few, need to be addressed and advanced to the next level. In conclusion, this Special Section on Advanced MV Power Electronics for Grid Interactive Applications in IEEE Transactions on Power Electronics (TPEL) provides an insight on some of the recent advances in MVPE and emerging challenges and potential solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Conditional Sixth-Harmonic Injection to Improve the Linear Modulation Range of Three-Phase Voltage-Source Converters

Overmodulation techniques are used to improve dc bus voltage utilization for three-phase voltage-source converters (VSCs), resulting in significant reduction in fundamental voltage gain. Conventional pulse width modulation (PWM) techniques for three-phase VSCs cannot enhance the linear range of dc bus utilization by more than 15.5%. Here, in this letter, a conditional sixth-harmonic injection technique is introduced, which can theoretically improve the linear modulation range by up to 19.2% for three-phase ac systems without additional hardware components. Experimental validation of the proposed scheme is presented, with its performance compared against the conventional third-harmonic PWM technique.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fundamental-Frequency Reactive Circulating Current Injection for Capacitor Voltage Balancing in Hybrid-MMC HVDC Systems During Riding Through PTG Faults

Here, this article presents a comprehensive analysis and a novel solution for the discharge problem on the half-bridge submodules' (HBSMs') capacitors in the hybrid modular multilevel converter (MMC)-based high-voltage direct current transmission systems under a long-term (e.g., several minutes or longer) pole-to-ground fault condition. The mechanism of this issue is analyzed, and then a solution based on fundamental-frequency reactive circulating current (FFRCC) injection is proposed. The influence of FFRCC injection is analyzed in terms of the fluctuated arm capacitor energy and the current stress of semiconductors. Moreover, an enhanced arm voltage modulation method based on HBSMs and full-bridge submodules coordinate control is proposed to accelerate the capacitor voltage balance of HBSMs. Finally, the performance of the proposed control strategy is verified by the simulation results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative operando XPS studies of quasi-Fermi level splitting and open-circuit voltage in CZTSe/CdS and CIGS/CdS junctions and device structures

This contribution describes operando x-ray photoelectron spectroscopy (opXPS) studies of Cu(In,Ga)Se 2 (CIGS) and Cu 2 ZnSnSe 4 (CZTSe) absorber layers and device structures. X-ray-excited valence-band and core-level spectra were acquired on bare absorber surfaces and after CdS and ZnO:Al depositions in standard absorber/CdS/ZnO/ZnO:Al device stacks. OpXPS data sets were acquired at various x-ray fluxes, with and without white-light illumination. From these measurements, quasi-Fermi level splitting (ΔE F ) values in the absorber/CdS junctions were measured directly as a function of excitation conditions. For both CIGS and CZTSe, results show that ..delta..EF proportional to the full open-circuit voltage (V OC ) of the completed devices is present after the deposition of the CdS layer - i.e., E F = qV OC - demonstrating that the so-called V OC deficit in CZTSe solar cells is also present at this stage of processing. The authors find that photoexcitation due to x-rays or stray visible light during XPS or similar measurements can produce measurable photovoltages in materials, absorber/CdS junctions, and finished devices. In situ current density versus voltage measurements on a typical CIGS device reveal that x-ray-induced photoexcitation associated with typical XPS measurement conditions is equivalent to ~3 x 10 -3 suns, which in this study produced V OC = 440 mV. These findings demonstrate that accounting for photoexcitation conditions during XPS or similar measurements can improve band-offset determinations and produce more reliable values for the junction built-in voltage. The implications of the study findings on the CZTSe V OC deficit and device performance are discussed.

36 MATERIALS SCIENCE↗

Effect of frequency and applied voltage of an atmospheric-pressure dielectric-barrier discharge on breakdown and hydroxyl-radical generation with a liquid electrode

This work examines the effect of the frequency and peak applied voltage on hydroxyl-radical generation in a dielectric-barrier plasma discharge between a metallic needle electrode and one electrode covered with dielectric. The authors examine a system that can expose up to 96 liquid samples in an automated fashion without human intervention beyond setting the initial software configuration. Then, hydroxylradical concentration, measured through coumarin fluorescence, was measured for 5 s plasma exposures generated under different highvoltage conditions with frequencies from 2 to 16 kHz and amplitudes from 4 to 9 kV. Their results show that an increase in frequency and/or applied voltage, within the range prescribed above and the limits of the high-voltage power supply, can yield up to a 150% increase in fluorescence with an equivalent hydroxyl-radical increase. Applications using typical previous methods, such as the Fenton Reaction, are limited in that they continuously generate hydroxyl radicals over millisecond and longer intervals. These results establish the electrical parameters that can now be applied to polymers, like proteins, which show three dimensional structures that are flexible and fluctuate on a microsecond and nanosecond time scale, with hydroxyl-radical generation on this time scale using this device. Additionally, plasma exposures may be optimized for a great variety of proteins, devices and techniques, where hydroxyl-radical generation is of utmost importance, reducing exposure time and potential subjection of samples to harmful side effects.

42 ENGINEERING↗

Kinetics of charged particles in a high-voltage gas discharge in a nonuniform electrostatic field

A high-voltage gas discharge is of interest as a possible means of generating directed flows of low-temperature plasma in the off-electrode space distinguished by its original features [1–4]. We propose a model for calculating the trajectories of charges particles in a high-voltage gas discharge in nitrogen at a pressure of 0.15 Torr existing in a nonuniform electrostatic field and the strength of this field. Based on the results of our calculations, we supplement and refine the extensive experimental data concerning the investigation of such a discharge published in [1, 2, 5–8]; good agreement between the theory and experiment has been achieved. The discharge burning is initiated and maintained through bulk electron-impact ionization and ion–electron emission. We have determined the sizes of the cathode surface regions responsible for these processes, including the sizes of the axial zone involved in the discharge generation. The main effect determining the kinetics of charged particles consists in a sharp decrease in the strength of the field under consideration outside the interelectrode space, which allows a free motion of charges with specific energies and trajectories to be generated in it. The simulation results confirm that complex electrode systems that allow directed plasma flows to be generated at a discharge current of hundreds or thousands of milliamperes and a voltage on the electrodes of 0.3–1 kV can be implemented in practice [3, 9, 10].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of inductive and capacitive coupling on the current–voltage characteristic and electromagnetic radiation from a system of Josephson junctions

We have studied the current–voltage characteristic of a system of long Josephson junctions taking into account the inductive and capacitive coupling. The dependence of the average time derivative of the phase difference on the bias current and spatiotemporal dependences of the phase difference and magnetic field in each junction are considered. The possibility of branching of the current–voltage characteristic in the region of zero field step, which is associated with different numbers of fluxons in individual Josephson junctions, is demonstrated. The current–voltage characteristic of the system of Josephson junctions is compared with the case of a single junction, and it is shown that the observed branching is due to coupling between the junctions. The intensity of electromagnetic radiation associated with motion of fluxons is calculated, and the effect of coupling between junctions on the radiation power is analyzed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗