Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

System and method for assaying a radionuclide

A system for assaying a radionuclide includes a liquid scintillation detector, an analyzer connected to the liquid scintillation detector, and a delay circuit connected to the analyzer. A gamma detector and a multi-channel analyzer are connected to the delay circuit and the gamma detector. The multi-channel analyzer produces a signal reflective of the radionuclide in the sample. A method for assaying a radionuclide includes selecting a sample, detecting alpha or beta emissions from the sample with a liquid scintillation detector, producing a first signal reflective of the alpha or beta emissions, and delaying the first signal a predetermined time. The method further includes detecting gamma emissions from the sample, producing a second signal reflective of the gamma emissions, and combining the delayed first signal with the second signal to produce a third signal reflective of the radionuclide.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurement of free chlorine levels in water using potentiometric responses of biofilms and applications for monitoring and managing the quality of potable water

We report residual free chlorine is not monitored continuously at scale in drinking water distribution systems because existing real-time sensor technologies require frequent maintenance, cleaning, and calibration, which makes these products too costly to be used throughout a distribution system. As a result, current measurement approaches require manual sampling, which is not feasible for the consistent monitoring of free chlorine because chlorine concentrations vary significantly throughout pipeline distribution and over time and space. This research presents an alternative and cost-effective method of predicting free chlorine levels in drinking water using graphite electrodes coated with naturally grown microbial biofilms. This Microbial Potentiometric Sensor (MPS) array was installed in a Continuously Mixed Batch Reactor (CMBR), and drinking water containing variable free chlorine concentrations. The chlorine concentrations were introduced in a controlled manner, and the MPS signals were monitored over time. MPS signals were measured from the change in Open Circuit Potential (OCP) across the MPS array in real-time. An empirically derived relationship between the normalized change in OCP and free chlorine was established by fitting individual and average MPS data to a decaying exponential growth function in order to predict free chlorine levels. The results show that free chlorine can be predicted with reasonable accuracy, with model validation showing an average absolute error of ±0.09 ppm below 1.1 ppm and ±0.30 ppm between 1.1 and 2.7 ppm. However, the accuracy of predictions was reduced at higher free chlorine levels. The researchers conclude that MPS systems may benefit drinking water distribution systems by measuring free chlorine. These advantages of the MPS are especially pronounced in the developing world because this system is inexpensive and does not require routine maintenance or cleaning. The system relies on a naturally forming and regenerating biofilm and an inexpensive potentiometric meter to produce stable measurements.

54 ENVIRONMENTAL SCIENCES↗

Digitally Enhanced Heterodyne Interferometry

Spurious interference limits the performance of many interferometric measurements. Digitally enhanced interferometry (DEI) improves measurement sensitivity by augmenting conventional heterodyne interferometry with pseudo-random noise (PRN) code phase modulation. DEI effectively changes the measurement problem from one of hardware (optics, electronics), which may deteriorate over time, to one of software (modulation, digital signal processing), which does not. DEI isolates interferometric signals based on their delay. Interferometric signals are effectively time-tagged by phase-modulating the laser source with a PRN code. DEI improves measurement sensitivity by exploiting the autocorrelation properties of the PRN to isolate only the signal of interest and reject spurious interference. The properties of the PRN code determine the degree of isolation.

Shaddock, Daniel↗

Visualizations of Travel Time Performance Based on Vehicle Reidentification Data

This paper provides a visual reference of the breadth of arterial performance phenomena based on travel time measures obtained from reidentification technology that has proliferated in the past 5 years. These graphical performance measures are revealed through overlay charts and statistical distribution as revealed through cumulative frequency diagrams (CFDs). With overlays of vehicle travel times from multiple days, dominant traffic patterns over a 24-h period are reinforced and reveal the traffic behavior induced primarily by the operation of traffic control at signalized intersections. A cumulative distribution function in the statistical literature provides a method for comparing traffic patterns from various time frames or locations in a compact visual format that provides intuitive feedback on arterial performance. The CFD may be accumulated hourly, by peak periods, or by time periods specific to signal timing plans that are in effect. Combined, overlay charts and CFDs provide visual tools with which to assess the quality and consistency of traffic movement for various periods throughout the day efficiently, without sacrificing detail, which is a typical byproduct of numeric-based performance measures. These methods are particularly effective for comparing before-and-after median travel times, as well as changes in interquartile range, to assess travel time reliability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adaptive Online Multivariate Signal Extraction With Locally Weighted Robust Polynomial Regression

High-frequency, multivariate data collected in real-time and used to control or make decisions regarding a process’ operation often contain some noise and outliers. Thus, a method to extract the signal is needed in order to reduce the number and magnitude of control-based adjustments that are implemented. Such a method must be (i) online, depending only on past and current observations; (ii) fast, producing a smooth value more quickly than the measurement frequency; (iii) robust, ignoring brief bursts of erroneously measured values; (iv) multivariate, ignoring observations that are jointly unusual; (v) adaptive, adjusting to periods of rapid fluctuation in the signal versus periods of stability; and (vi) purely data-driven, not incorporating any information about the process from which the data are collected. Most existing methods are only able to address a subset of these six features. Furthermore, we also require the method to be nonlinear, providing a local nonlinear estimate of the signal. In this work, we propose a novel, real-time signal extraction method based on a local, robust polynomial fit. We demonstrate the performance of our method compared to a state-of-the-art competitor through simulation. For illustration, the methodology is applied to data collected from a reverse osmosis water treatment process.

97 MATHEMATICS AND COMPUTING↗

Communication: Proton NMR dipolar-correlation effect as a method for investigating segmental diffusion in polymer melts

A simple and fast method for the investigation of segmental diffusion in high molar mass polymer melts is presented. The method is based on a special function, called proton dipolar-correlation build-up function, which is constructed from Hahn Echo signals measured at times t and t/2. The initial rise of this function contains additive contributions from both inter- and intramolecular magnetic dipole-dipole interactions. The intermolecular contribution depends on the relative mean squared displacements (MSDs) of polymer segments from different macromolecules, while the intramolecular part reflects segmental reorientations. Separation of both contributions via isotope dilution provides access to segmental displacements in polymer melts at millisecond range, which is hardly accessible by other methods. The feasibility of the method is illustrated by investigating protonated and deuterated polybutadiene melts with molecular mass 196 000 g/mol at different temperatures. The observed exponent of the power law of the segmental MSD is close to 0.32 ± 0.03 at times when the root MSD is in between 45 Å and 75 Å, and the intermolecular proton dipole-dipole contribution to the total proton Hahn Echo NMR signal is larger than 50% and increases with time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsar-Calibrated Timing Source for Synchronized Sampling

The Global Positioning System (GPS) is critical to the real-time synchronized sampling of phasor measurement units (PMUs). Unfortunately, GPS signals are occasionally unstable due to several factors such as weak satellite signal and GPS spoofing, thereby leaving the PMU with a degraded sampling performance. In this letter, a novel Pulsar-calibrated Timing Source (PTS) is proposed as the alternative timing source for synchronized sampling. Further, the PTS can generate the timing signal with a 1 μs drift error within 91 holdover minutes to ensure continuity of sampling accuracy. Experimental tests are conducted and the results reveal the reliability and accuracy of the PTS for PMU synchronization.

42 ENGINEERING↗

Isotope effect on hydrated electron relaxation dynamics studied with time-resolved liquid jet photoelectron spectroscopy

The excited state relaxation dynamics of the solvated electron in H{sub 2}O and D{sub 2}O are investigated using time-resolved photoelectron spectroscopy in a liquid microjet. The data show that the initial excited state decays on a time scale of 75 ± 12 fs in H{sub 2}O and 102 ± 8 fs in D{sub 2}O, followed by slower relaxation on time scales of 400 ± 70 fs and 390 ± 70 fs that are isotopically invariant within the precision of our measurements. Based on the time evolution of the transient signals, the faster and slower time constants are assigned to p → s internal conversion (IC) of the hydrated electron and relaxation on the ground electronic state, respectively. This assignment is consistent with the non-adiabatic mechanism for relaxation of the hydrated electron and yields an isotope effect of 1.4 ± 0.2 for IC of the hydrated electron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining Direction of Arrival at a Y-Shaped Antenna Array

An algorithm computes the direction of arrival (both azimuth and elevation angles) of a lightning-induced electromagnetic signal from differences among the times of arrival of the signal at four antennas in a Y-shaped array on the ground. In the original intended application of the algorithm, the baselines of the array are about 90 m long and the array is part of a lightning-detection-and-ranging (LDAR) system. The algorithm and its underlying equations can also be used to compute directions of arrival of impulsive phenomena other than lightning on arrays of sensors other than radio antennas: for example, of an acoustic pulse arriving at an array of microphones.

Starr, Stan↗

HydroCube Mission Concept: P-Band Signals of Opportunity for Remote Sensing of Snow and Root Zone Soil Moisture

We have developed the HydroCube mission concept with a constellation of small satellites to remotely sense Snow Water Equivalent (SWE) and Root Zone Soil Moisture (RZSM). The HydroCube satellites would operate at sun-synchronous 3-day repeat polar orbits with a spatial resolution of about 1-3 Km. The mission goals would be to improve the estimation of terrestrial water storage and weather forecasts. Root-zone soil moisture and snow water storage in land are critical parameters of the water cycle. The HydroCube Signals of Opportunity (SoOp) concept utilizes passive receivers to detect the reflection of strong existing P-band radio signals from geostationary Mobile Use Objective System (MUOS) communication satellites. The SWE remote sensing measurement principle using the P-band SoOp is based on the propagation delay (or phase change) of radio signals through the snowpack. The time delay of the reflected signal due to the snowpack with respect to snow-free conditions is directly proportional to the snowpack SWE. To address the ionospheric delay at P-band frequencies, the signals from both MUOS bands (360-380 MHz and 250-270 MHz) would be used. We have conducted an analysis to trade off the spatial resolution for a space-based sensor and measurement accuracy. Through modeling analysis, we find that the dual-band MUOS signals would allow estimation of soil moisture and surface roughness together. From the two MUOS frequencies at 260 MHz and 370 MHz, we can retrieve the soil moisture from the reflectivity ratio scaled by wavenumbers using the two P-band frequencies for MUOS. A modeling analysis using layered stratified model has been completed to determine the sensitivity requirements of HydroCube measurements. For mission concept demonstration, a field campaign has been conducted at the Fraser Experimental Forest in Colorado since February 2016. The data acquired has provided support to the HydroCube concept.

Derksen, Chris↗

UAS-Based P-Band Signals of Opportunity for Remote Sensing of Snow and Root Zone Soil Moisture

We have developed the P-band Signals of Opportunity (SoOp) sensor based on the Unmanned Aircraft System (UAS) to remotely sense Snow Water Equivalent (SWE) and Root Zone Soil Moisture (RZSM). The P-band UAS SoOp sensor for Hydrology (UASHydro) would operate on the S2 aircraft developed by Black Swift Technologies for sensing of SWE and RZSM with a spatial resolution of about 10m. Root-zone soil moisture and snow water storage in land are critical parameters of the water cycle. The long-term goal of our development would be to use small UAS to perform regional high resolution observation of two key hydrological measurements to improve the estimation of terrestrial water storage for water management, crop production and forecasts of natural hazard. The UASHydro concept utilizes passive receivers to detect the reflection of strong existing P-band radio signals at the 360-380 MHz band from geostationary Mobile Use Objective System (MUOS) communication satellites launched by the US Navy. The SWE remote sensing measurement principle using the P-band SoOp is based on the propagation delay (or phase change) of radio signals through the snowpack. The time delay of the reflected signal due to the snowpack with respect to snow-free conditions is directly proportional to the snowpack SWE, while the soil moisture can be retrieved from the reflectivity at the P-band frequencies for MUOS. We have been conducting ground-based campaigns to test the instrumentation and data processing methods at the Fraser Experimental Forest in Colorado since February 2016. The field campaign data has provided support to the measurement concept. To install the SoOp technologies on the UAS, a lightweight antenna has been built and interfaces with the S2 built by Black Swift Technologies have been completed. A set of flights have been planned starting April 2018 through the end of 2018 in Colorado.

Elston, Jack↗

Technical Note: Intrafractional changes in time lag relationship between anterior–posterior external and superior–inferior internal motion signals in abdominal tumor sites

Purpose: To investigate constancy, within a treatment session, of the time lag relationship between implanted markers in abdominal tumors and an external motion surrogate. Methods: Six gastroesophageal junction and three pancreatic cancer patients (IRB-approved protocol) received two cone-beam CTs (CBCT), one before and one after treatment. Time between scans was less than 30 min. Each patient had at least one implanted fiducial marker near the tumor. In all scans, abdominal displacement (Varian RPM) was recorded as the external motion signal. Purpose-built software tracked fiducials, representing internal signal, in CBCT projection images. Time lag between superior–inferior (SI) internal and anterior–posterior external signals was found by maximizing the correlation coefficient in each breathing cycle and averaging over all cycles. Time-lag-induced discrepancy between internal SI position and that predicted from the external signal (external prediction error) was also calculated. Results: Mean ± standard deviation time lag, over all scans and patients, was 0.10 ± 0.07 s (range 0.01–0.36 s). External signal lagged the internal in 17/18 scans. Change in time lag between pre- and post-treatment CBCT was 0.06 ± 0.07 s (range 0.01–0.22 s), corresponding to 3.1% ± 3.7% (range 0.6%–10.8%) of gate width (range 1.6–3.1 s). In only one patient, change in time lag exceeded 10% of the gate width. External prediction error over all scans of all patients varied from 0.1 ± 0.1 to 1.6 ± 0.4 mm. Conclusions: Time lag between internal motion along SI and external signals is small compared to the treatment gate width of abdominal patients examined in this study. Change in time lag within a treatment session, inferred from pre- to post-treatment measurements is also small, suggesting that a single measurement of time lag at the session start is adequate. These findings require confirmation in a larger number of patients.

60 APPLIED LIFE SCIENCES↗

PERIODOGRAMS FOR MULTIBAND ASTRONOMICAL TIME SERIES

This paper introduces the multiband periodogram, a general extension of the well-known Lomb–Scargle approach for detecting periodic signals in time-domain data. In addition to advantages of the Lomb–Scargle method such as treatment of non-uniform sampling and heteroscedastic errors, the multiband periodogram significantly improves period finding for randomly sampled multiband light curves (e.g., Pan-STARRS, DES, and LSST). The light curves in each band are modeled as arbitrary truncated Fourier series, with the period and phase shared across all bands. The key aspect is the use of Tikhonov regularization which drives most of the variability into the so-called base model common to all bands, while fits for individual bands describe residuals relative to the base model and typically require lower-order Fourier series. This decrease in the effective model complexity is the main reason for improved performance. After a pedagogical development of the formalism of least-squares spectral analysis, which motivates the essential features of the multiband model, we use simulated light curves and randomly subsampled SDSS Stripe 82 data to demonstrate the superiority of this method compared to other methods from the literature and find that this method will be able to efficiently determine the correct period in the majority of LSST’s bright RR Lyrae stars with as little as six months of LSST data, a vast improvement over the years of data reported to be required by previous studies. A Python implementation of this method, along with code to fully reproduce the results reported here, is available on GitHub.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust power detector for wideband signals among many single tone signals

Various technologies for isolating a signal of interest from signals received contemporaneously by an antenna are described herein. A time period for which a signal of interest is present in a second signal can be identified based upon ratios of values of the second signal to the mean value of the second signal. When the ratio of the value of the second signal at a particular time to the mean of the second signal exceeds a threshold value, the signal of interest is considered to be present in the second signal.

47 OTHER INSTRUMENTATION↗

Robust power detector for wideband signals among many single tone signals

Various technologies for isolating a signal of interest from signals received contemporaneously by an antenna are described herein. A time period for which a signal of interest is present in a second signal can be identified based upon ratios of values of the second signal to the mean value of the second signal. When the ratio of the value of the second signal at a particular time to the mean of the second signal exceeds a threshold value, the signal of interest is considered to be present in the second signal.

47 OTHER INSTRUMENTATION↗

Wilson loops with neural networks

Wilson loops are essential objects in QCD and have been pivotal in scale setting and demonstrating confinement. Various generalizations are crucial for computations needed in effective field theories. In lattice gauge theory, Wilson loop calculations face challenges, including excited-state contamination at short times and the signal-to-noise ratio issue at longer times. To address these problems, we develop a new method by using neural networks to parametrize interpolators for the static quark-antiquark pair. We construct gauge-equivariant layers for the network and train it to find the ground state of the system. The trained network itself is then treated as our new observable for the inference. Our results demonstrate a significant improvement in the signal compared to traditional Wilson loops, performing as well as Coulomb-gauge Wilson-line correlators while maintaining gauge invariance. Additionally, we present an example where the optimized ground state is used to measure the static force directly, as well as another example combining this method with the multilevel algorithm. Finally, we extend the formalism to find excited-state interpolators for static quark-antiquark systems. To our knowledge, this work is the first study of neural networks with a physically motivated loss function for Wilson loops.

Bellscheidt, Verena [Massachusetts Inst. of Techno↗

Lindblad equations for strongly coupled populations and coherences in photosynthetic complexes

Recent experimental observations of time-resolved multidimensional signals in the light-harvesting antennae Fenna-Mathews-Olson [G. S. Engel et al., Nature (London) 446, 782 (2007)] show large oscillations of exciton populations coupled to the long-lived coherences. These effects may not be reproduced by the standard Redfield theory which assumes weak coupling to a bath. A more general relaxation superoperator which holds for all system-bath coupling parameter regimes is constructed by taking into account the statistics (covariances) of Lindblad equation parameters. Simulations for a model dimer reproduce all observed strong coupling effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full waveform analysis for high pressure ultrasonic measurement

In this paper we report a data analysis protocol for ultrasonic velocity measurements carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. Synthetic ultrasonic signals for the time period between echoes from the two ends of the sample assembly are created with a few simple parameters as the echo waveform is modeled by the first echo from the anvil-assembly boundary. Each echo is modeled as a delta function with an amplitude and arrival time and convolved with this waveform. The final waveform, fit to the data, enables analysis of signals with overlapped echoes as they are common in small cell assemblies and high pressure.

47 OTHER INSTRUMENTATION↗