Electronics for the far-forward CMS muon detector upgrade, ME0

Abstract With the High Luminosity upgrade of the Large Hadron Collider (LHC) we expect increased instantaneous luminosities up to 7.5 × 10 34 cm −2 s −1 , or five times more than the original values. In order to maintain performance of the Compact Muon Solenoid (CMS) experiment under these conditions, ME0 is one of three new muon sub-detectors being added, along with GE1/1 and GE2/1, which use the triple Gas Electron Multiplier (GEM) technology. ME0 is designed to cover the forward region of 2.0 < | η | < 2.8, thus improving muon reconstruction at high background rates by supplementing other overlapping muon subsystems up to | η | = 2.4, while also extending the acceptance for the first time to | η | = 2.8. The readout electronics for ME0 must be designed to accommodate high data rates and be sufficiently radiation hard to operate close to the beamline. The Optohybrid (OH) board for ME0, which reads out data from the front-end VFAT3b ASICs, has therefore been designed to operate without an FPGA (unlike GE1/1 and GE2/1) to ensure radiation hardness. The ME0 OH uses the radiation-hard CERN-designed lpGBT ASIC and VTRx+ optical transceiver module for high bandwidth optical links up to 10.24 Gb/s. The backend system is based on the ATCA standard. The design and development status of the readout electronics for ME0 is presented, along with recent results from integration tests performed using the first prototypes.

Instruments & Instrumentation↗

Physiological Adaptations to Progressive Endurance Exercise Training in Adult and Aged Rats: Insights from the Molecular Transducers of Physical Activity Consortium (MoTrPAC)

While regular physical activity is a cornerstone of health, wellness, and vitality, the impact of endurance exercise training on molecular signaling within and across tissues remains to be delineated. The Molecular Transducers of Physical Activity Consortium (MoTrPAC) was established to characterize molecular networks underlying the adaptive response to exercise. Here, we describe the endurance exercise training studies undertaken by the Preclinical Animal Sites Studies component of MoTrPAC, in which we sought to develop and implement a standardized endurance exercise protocol in a large cohort of rats. To this end, Adult (6-mo) and Aged (18-mo) female (n = 151) and male (n = 143) Fischer 344 rats were subjected to progressive treadmill training (5 d/wk, ~70%–75% VO 2 max) for 1, 2, 4, or 8 wk; sedentary rats were studied as the control group. A total of 18 solid tissues, as well as blood, plasma, and feces, were collected to establish a publicly accessible biorepository and for extensive omics-based analyses by MoTrPAC. Treadmill training was highly effective, with robust improvements in skeletal muscle citrate synthase activity in as little as 1–2 wk and improvements in maximum run speed and maximal oxygen uptake by 4–8 wk. For body mass and composition, notable age- and sex-dependent responses were observed. This work in mature, treadmill-trained rats represents the most comprehensive and publicly accessible tissue biorepository, to date, and provides an unprecedented resource for studying temporal-, sex-, and age-specific responses to endurance exercise training in a preclinical rat model.

60 APPLIED LIFE SCIENCES↗

Phylodynamic Inference across Epidemic Scales

Within-host genetic diversity and large transmission bottlenecks confound phylodynamic inference of epidemiological dynamics. Conventional phylodynamic approaches assume that nodes in a time-scaled pathogen phylogeny correspond closely to the time of transmission between hosts that are ancestral to the sample. However, when hosts harbor diverse pathogen populations, node times can substantially pre-date infection times. Imperfect bottlenecks can cause lineages sampled in different individuals to coalesce in unexpected patterns. To address realistic violations of standard phylodynamic assumptions we developed a new inference approach based on a multi-scale coalescent model, accounting for nonlinear epidemiological dynamics, heterogeneous sampling through time, non-negligible genetic diversity of pathogens within hosts, and imperfect transmission bottlenecks. We apply this method to HIV-1 and Ebola virus (EBOV) outbreak sequence data, illustrating how and when conventional phylodynamic inference may give misleading results. Within-host diversity of HIV-1 causes substantial upwards bias in the number of infected hosts using conventional coalescent models, but estimates using the multi-scale model have greater consistency with reported number of diagnoses through time. In contrast, we find that within-host diversity of EBOV has little influence on estimated numbers of infected hosts or reproduction numbers, and estimates are highly consistent with the reported number of diagnoses through time. The multi-scale coalescent also enables estimation of within-host effective population size using single sequences from a random sample of patients. We find within-host population genetic diversity of HIV-1 p17 to be 2Nμ=0.012 (95% CI 0.0066–0.023), which is lower than estimates based on HIV envelope serial sequencing of individual patients.

59 BASIC BIOLOGICAL SCIENCES↗

Contact interactions in low scale string models with intersecting D6-branes

We evaluate the tree level four fermion string amplitudes in the TeV string mass scale models with intersecting D6-branes. The coefficient functions of contact interactions subsuming the contributions of string Regge resonance and winding mode excitations are obtained by subtracting out the contributions from the string massless and massive momentum modes. Numerical applications are developed for the standard-model-like solution of Cremades, Ibanez, and Marchesano for a toroidal orientifold with four intersecting D6-brane stacks. The chirality conserving contact interactions of the quarks and leptons are considered in applications to high-energy collider and flavor changing neutral current phenomenology. The two main free parameters consist of the string and compactification mass scales, m{sub s} and M{sub c}. Useful constraints on these parameters are derived from predictions for the Bhabha scattering differential cross section and for the observables associated to the mass shifts of the neutral meson systems K-K, B-B, D-D and the lepton number violating three-body leptonic decays of the charged leptons {mu} and {tau}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chasing the nonlinear evolution of matter power spectrum with a numerical resummation method: Solution of closure equations

We present a new numerical scheme to treat the nonlinear evolution of cosmological power spectra. Governing equations for matter power spectra have been previously derived by a nonperturbative technique with closure approximation. Solutions of the resultant closure equations just correspond to the resummation of an infinite class of perturbation corrections, and they consistently reproduce the one-loop results of standard perturbation theory. We develop a numerical algorithm to solve closure evolutions in both perturbative and nonperturbative regimes. The present numerical scheme is particularly suited for examining nonlinear matter power spectrum in general cosmological models, including modified theory of gravity. As a demonstration, we study weakly nonlinear evolution of power spectrum in a class of modified gravity models, as well as various dark energy models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Active Power and Flux Control of a Self-Excited Induction Generator for a Variable-Speed Wind Turbine Generation

A Self-Excited Induction Generation (SEIG) for a variable speed wind turbine generation(VS-WG) is normally considered to be a good candidate for implementation in stand-alone applications such as battery charging, hydrogenation, water pumping, water purification, water desalination, and etc. In this study, we have examined a study on active power and flux control strategies for a SEIG for a variable speed wind turbine generation. The control analysis for the proposed system is carried out by using PSCAD software. In the process, we can optimize the control design of the system, thereby enhancing and expediting the control design procedure for this application. With this study, this control design for a SEIG for VS-WG can become the industry standard for analysis and development in terms of SEIG.

17 WIND ENERGY↗

Shortwave Radiometer Calibration Methods Comparison and Resulting Solar Irradiance Measurement Differences: A User Perspective

Banks financing solar energy projects require assurance that these systems will produce the energy predicted. Furthermore, utility planners and grid system operators need to understand the impact of the variable solar resource on solar energy conversion system performance. Accurate solar radiation data sets reduce the expense associated with mitigating performance risk and assist in understanding the impacts of solar resource variability. The accuracy of solar radiation measured by radiometers depends on the instrument performance specification, installation method, calibration procedure, measurement conditions, maintenance practices, location, and environmental conditions. This study addresses the effect of different calibration methods provided by radiometric calibration service providers, such as NREL and manufacturers of radiometers, on the resulting calibration responsivity. Some of these radiometers are calibrated indoors and some outdoors. To establish or understand the differences in calibration methodology, we processed and analyzed field-measured data from these radiometers. This study investigates calibration responsivities provided by NREL's broadband outdoor radiometer calibration (BORCAL) and a few prominent manufacturers. The BORCAL method provides the outdoor calibration responsivity of pyranometers and pyrheliometers at 45 degree solar zenith angle, and as a function of solar zenith angle determined by clear-sky comparisons with reference irradiance. The BORCAL method also employs a thermal offset correction to the calibration responsivity of single-black thermopile detectors used in pyranometers. Indoor calibrations of radiometers by their manufacturers are performed using a stable artificial light source in a side-by-side comparison between the test radiometer under calibration and a reference radiometer of the same type. In both methods, the reference radiometer calibrations are traceable to the World Radiometric Reference (WRR). These different methods of calibration demonstrated +1% to +2% differences in solar irradiance measurement. Analyzing these differences will ultimately help determine the uncertainty of the field radiometer data and guide the development of a consensus standard for calibration. Further advancing procedures for precisely calibrating radiometers to world reference standards that reduce measurement uncertainty will allow more accurate prediction of solar output and improve the bankability of solar projects.

14 SOLAR ENERGY↗

Quantitative Total and Diffuse Reflectance Laboratory Measurements for Remote, Standoff, and Point Sensing

Methods for making total and diffuse directional/hemispherical reflectance measurements in the shortwave to longwave infrared using an integrating sphere are described. The sphere is a commercial, off-the-shelf optical device with its sample port at the bottom, which is essential for examining powdered samples without using a cover glass. The reflectance spectra of recently-developed National Institute of Standards and Technology (NIST, USA) infrared reflectance standards have been measured using the sphere. Reflectance spectra of other materials such as Spectralon and Infragold were also measured. The relative systematic error for the total reflectance measurements is estimated to be on the order of 3%, and random measurement error for multiple samples of each material is on the order of 0.5%.

Integrating sphere, infrared, total reflectance, d↗

Dose response of selected solid state detectors in applied homogeneous transverse and longitudinal magnetic fields

Purpose: MR-Linac devices under development worldwide will require standard calibration, commissioning, and quality assurance. Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is therefore evaluated in varying transverse and longitudinal magnetic fields for this purpose. Methods: The Monte Carlo code PENELOPE was used to model irradiation of a PTW 60003 diamond detector and IBA PFD diode detector in the presence of a magnetic field. The field itself was varied in strength, and oriented both transversely and longitudinally with respect to the incident photon beam. The long axis of the detectors was oriented either parallel or perpendicular to the photon beam. The dose to the active volume of each detector in air was scored, and its ratio to dose with zero magnetic field strength was determined as the “dose response” in magnetic field. Measurements at low fields for both detectors in transverse magnetic fields were taken to evaluate the accuracy of the simulations. Additional simulations were performed in a water phantom to obtain few representative points for beam profile and percent depth dose measurements. Results: Simulations show significant dose response as a function of magnetic field in transverse field geometries. This response can be near 20% at 1.5 T, and it is highly dependent on the detectors’ relative orientation to the magnetic field, the energy of the photon beam, and detector composition. Measurements at low transverse magnetic fields verify the simulations for both detectors in their relative orientations to radiation beam. Longitudinal magnetic fields, in contrast, show little dose response, rising slowly with magnetic field, and reaching 0.5%–1% at 1.5 T regardless of detector orientation. Water tank and in air simulation results were the same within simulation uncertainty where lateral electronic equilibrium is present and expectedly differed at the beam edge in transverse field orientations only. Due to the difference in design, the two detectors behaved differently. Conclusions: When transverse magnetic fields are present, great care must be taken when using diamond or diode detectors. Dose response varies with relative detector orientation, magnetic field strength, and between detectors. This response can be considerable (∼20% for both detectors). Both detectors in longitudinal fields exhibit little to no dose response as a function of magnetic field. Water tank simulations seem to suggest that the diode detector is better suited to general beam commissioning, and each detector must be investigated separately.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-358: Is Auto-Planning Useful for Volumetric-Modulated Arc Therapy Planning in Rectal Cancer Radiotherapy?

Purpose: To evaluate whether Auto-Planning based volumetric-modulated radiotherapy (auto-VMAT) can reduce manual interaction time during treatment planning and improve plan quality for rectal cancer radiotherapy. Methods: Ten rectal cancer patients (stage II and III) after radical resection using Dixon surgery were enrolled. All patients were treated with VMAT technique. The manual VMAT plans (man-VMAT) were designed in the Pinnacle treatment planning system (Version 9.10) following the standard treatment planning procedure developed in our department. Clinical plans were manually designed by our experienced dosimetrists. Additionally, an auto-VMAT plan was created for each patient using Auto-Planning module. However, manual interaction was still applied to meet the clinical requirements. The treatment planning time and plan quality surrogated by the DVH parameters were compared between manual and automated plans. Results: The total planning time and manual interaction time were 50.38 and 4.47 min for the auto-VMAT and 36.81 and 16.94 min for the man-VMAT (t=60.14,−23.86; p=0.000, 0.000). In terms of plan quality, both plans meet the clinical requirements. The PTV homogeneity index (HI) and conformity index (CI) were 0.054 and 0.822 for the auto-VMAT and 0.059 and 0.815 for the man-VMAT (t=−1.72, 0.36;p=0.119,0.730).Compared to the man-VMAT, the auto-VMAT showed reduction of 11.9% and 0.7% in V40 and V50 of the bladder, respectively.The V30 and D mean were reduced by 14.0% and 5.1Gy in the left femur and 12.2% and 3.8Gy in the right femur. Conclusion: The Auto-Planning based VMAT plans not only shows similar or superior plan quality to the manual ones in the rectal cancer radiotherapy, but also improve the planning efficiency significantly. However, manual interactions are still required to achieve a clinically acceptable plan based on our experiences.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators

Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional data sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.

60 APPLIED LIFE SCIENCES↗

Radial force on the vacuum chamber wall during thermal quench in tokamaks

The radial force balance during a thermal quench in tokamaks is analyzed. As a rule, the duration τ{sub tp} of such events is much shorter than the resistive time τ{sub w} of the vacuum chamber wall. Therefore, the perturbations of the magnetic field B produced by the evolving plasma cannot penetrate the wall, which makes different the magnetic pressures on its inner and outer sides. The goal of this work is the analytical estimation of the resulting integral radial force on the wall. The plasma is considered axially symmetric; for the description of radial forces on the wall, the results of V.D. Shafranov’s classical work [J. Nucl. Energy C 5, 251 (1963)] are used. Developed for tokamaks, the standard equilibrium theory considers three interacting systems: plasma, poloidal field coils, and toroidal field coils. Here, the wall is additionally incorporated with currents driven by ∂B/∂t≠0 accompanying the fast loss of the plasma thermal energy. It is shown that they essentially affect the force redistribution, thereby leading to large loads on the wall. The estimates prove that these loads have to be accounted for in the disruptive scenarios in large tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging in Diagnostic Nuclear Medicine

Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are modern methods for visualization in diagnostic nuclear medicine. SPECT is known as a workhorse in cardiology, and PET is the gold standard in oncology. The development of nuclear medicine is provided by cooperation of physicists, mathematicians, biologists, medical doctors, and radio-chemists. In spite of extensive clinical applications, several problems may lead to false diagnoses. In particular, the correction of attenuation of gamma radiation in human organs must be taken into account. For interpretation and evaluation of such an effect on the clinical results, we perform physico-mathematical simulation of the SPECT diagnostics in cardiology in the absence and presence of the correction of attenuation. A brief review of the state-of-the art is presented. The simulation employs the first Russian anthropomorphic mathematical phantom that describes the distribution of radio-pharmacological agent ({sup 99m }Tc-methoxyisobutylisonitrile) in chest organs of a typical male patient. A model for calculation of raw images is developed with allowance for attenuation of radiation in biological tissues and the effect of collimator and detector. The results of the proposed models and calculated images are compared with clinical images obtained at the Meshalkin Institute of Circulation Pathology (Novosibirsk) and Myasnikov Institute of Clinical Cardiology (Moscow). Statistical algorithms are developed for the solution of the inverse problem of image reconstruction based on the entropy principle. The clinical and physico-mathematical approaches are compared in the evaluation of the effect of correction on the quality of reconstructed images of the left ventricle of myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

eProject Builder (ePB) v3.1

eProject Builder (ePB) is a secure, web-based system that enables agencies and ESCOs to securely: (1) preserve, track, and access energy project information for the life of the contract (2) quickly generate data and reports for their portfolio of projects (3) develop project scenarios using standardized amortization calculations (4) benchmark new projects against historical project data

Larsen, Peter↗

ROI Hide and Seek Protocol v1

1. Segmentation We provide scripts for the model definition of the U-net architecture adapted from: https://github.com/jvanvugt/pytorch-unet/blob/master/unet.py We developed scripts for preparing the lung segmentation data set. We developed scripts for training the U-Net architecture. We developed scripts for applying the trained U-Net model to perform the ROI Hide and Seek protocol on the classification dataset to create the modified dataset. 2. Classification We provide scripts for the training of the COVID-Net models provided by Linda Wang, this code is adapted from her github repository: https://github.com/lindawangg/COVID-Net/tree/d7b36831d854f57de5bc7557217f5439e86e016f. These scripts were modified to save training log information as well as to load the provided models in their github repo. We developed scripts for training standard Neural Network Models (resnet 50, vgg 11, Alexnet) on the COVID datsets along with the ROI Hide and Seek altered datasets.

Sadre, Robbie↗

PHEV-EV Charger Technology Assessment with an Emphasis on V2G Operation

More battery powered electric vehicles (EVs) and plug-in hybrid electric vehicles (PHEVs) will be introduced to the market in 2011 and beyond. Since these vehicles have large batteries that need to be charged from an external power source or directly from the grid, their batteries, charging circuits, charging stations/infrastructures, and grid interconnection issues are garnering more attention. This report summarizes information regarding the batteries used in PHEVs, different types of chargers, charging standards and circuits, and compares different topologies. Furthermore, it includes a list of vehicles that are going to be in the market soon with information on their charging and energy storage equipment. A summary of different standards governing charging circuits and charging stations concludes the report. There are several battery types that are available for PHEVs; however, the most popular ones have nickel metal hydride (NiMH) and lithium-ion (Li-ion) chemistries. The former one is being used in current hybrid electric vehicles (HEVs), but the latter will be used in most of the PHEVs and EVs due to higher energy densities and higher efficiencies. The chargers can be classified based on the circuit topologies (dedicated or integrated), location of the charger (either on or off the vehicle), connection (conductive, inductive/wireless, and mechanical), electrical waveform (direct current (dc) or alternating current (ac)), and the direction of power flow (unidirectional or bidirectional). The first PHEVs typically will have dedicated, on-board, unidirectional chargers that will have conductive connections to the charging stations or wall outlets and will be charged using either dc or ac. In the near future, bidirectional chargers might also be used in these vehicles once the benefits of practical vehicle to grid applications are realized. The terms charger and charging station cause terminology confusion. To prevent misunderstandings, a more descriptive term of electric vehicle supply equipment (EVSE) is used instead of charging station. The charger is the power conversion equipment that connects the battery to the grid or another power source, while EVSE refers to external equipment between the grid or other power source and the vehicle. EVSE might include conductors, connectors, attachment plugs, microprocessors, energy measurement devices, transformers, etc. Presently, there are more than 40 companies that are producing EVSEs. There are several standards and codes regarding conductive and inductive chargers and EVSEs from the Society of Automotive Engineers (SAE), the Underwriter Laboratories (UL), the International Electrotechnical Commission (IEC), and the National Electric Code (NEC). The two main standards from SAE describe the requirements for conductive and inductive coupled chargers and the charging levels. For inductive coupled charging, three levels are specified: Level 1 (120 V and 12 A, single-phase), Level 2 (208 V-240 V and 32 A, single-phase), and Level 3 (208-600 V and 400 A, three-phase) . The standard for the conductive-coupled charger also has similar charging ratings for Levels 1 and 2, but it allows higher current ratings for Level 2 charging up to 80 A. Level 3 charging for this standard is still under development and considers dc charging instead of three-phase ac. More details in these areas and related references can be found in this Oak Ridge National Laboratory (ORNL) report on PHEV-EV charger technology assessment.

25 ENERGY STORAGE↗

Built-Environment Wind Turbine Roadmap

Although only a small contributor to total electricity production needs, built-environment wind turbines (BWTs) nonetheless have the potential to influence the public's consideration of renewable energy, and wind energy in particular. Higher population concentrations in urban environments offer greater opportunities for project visibility and an opportunity to acquaint large numbers of people to the advantages of wind projects on a larger scale. However, turbine failures will be equally visible and could have a negative effect on public perception of wind technology. This roadmap provides a framework for achieving the vision set forth by the attendees of the Built-Environment Wind Turbine Workshop on August 11 - 12, 2010, at the U.S. Department of Energy's National Renewable Energy Laboratory. The BWT roadmap outlines the stakeholder actions that could be taken to overcome the barriers identified. The actions are categorized as near-term (0 - 3 years), medium-term (4 - 7 years), and both near- and medium-term (requiring immediate to medium-term effort). To accomplish these actions, a strategic approach was developed that identifies two focus areas: understanding the built-environment wind resource and developing testing and design standards. The authors summarize the expertise and resources required in these areas.

17 WIND ENERGY↗

Integrated Detection of Pathogens and Host Biomarkers for Wounds

The increasing incidence and complications arising from combat wounds has necessitated a reassessment of methods for effective treatment. Infection, excessive inflammation, and incidence of drug-resistant organisms all contribute toward negative outcomes for afflicted individuals. The organisms and host processes involved in wound progression, however, are not well understood. We therefore set out, using our unique technical resources, to construct a profile of combat wounds. We employed the Lawrence Livermore Microbial Detection Array and next-generation sequencing to identify all microorganisms present in wound samples, building complete profiles of wound infection. These methods allowed for comprehensive assessment of the wound bioburden, revealing pathogens that could not be detected by standard microbiology. Further, we developed and applied proteomics technology and identified host biomarkers associated with wound resolution. In combination with our pathogen data, these biomarker discovery efforts will provide a profile that will assist in clinical outcome classification and will provide vital insight for treatment of these complex cases.