Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,045 records · Page 58

Performance of a focused cavity aerosol spectrometer for measurements in the stratosphere of particle size in the 0.06-2.0-micrometer-diameter range

A focused cavity aerosol spectrometer aboard a NASA ER-2 high-altitude aircraft provided high-resolution measurements of the size of the stratospheric particles in the 0.06-2.0-micrometer-diameter range in flights following the eruption of Mount Pinatubo in 1991. Effects of anisokinetic sampling and evaporation in the sampling system were accounted for by means adapted and specifically developed for this instrument. Calibrations with monodisperse aerosol particles provided the instrument's response matrix, which upon inversion during data reduction yielded the particle size distributions. The resultant dataset is internally consistent and generally shows agreement to within a factor of 2 with comparable measurements simultaneously obtained by a condensation nuclei counter, a forward-scattering spectrometer probe, and aerosol particle impactors, as well as with nearby extinction profiles obtained by satellite measurements and with lidar measurements of backscatter.

Jonsson, H. H.↗

Giotto ion mass spectrometer measurements at comet P/Grigg-Skjellerup

The Giotto ion mass spectrometer high-intensity spectrometer (IMS-HIS) measured fluxes of ions from about 260,000 km before (1008:37 UT spacecraft time) to about 86,000 km after (1701:33 UT spacecraft time) closest approach to comet P/Grigg-Skjellerup during the encounter on July 10, 1992. Although the HIS sensor was not designed to measure protons, these ions were measured far from the comet. Close in to the comet, the ions observed were probably also protons, although heavier ions cannot be completely ruled out. Considerable temporal structure appears in the data, well-correlated with the data of other instruments onboard, especially those of the magnetometer. In particular, the ion count rate correlates with the direction of the magnetic field. This strong modulation at the water group ion cyclotron period (approx. 90 s) inside the inbound bow wave indicates a very narrow ion pitch angle distribution. Hence at Grigg-Skjellerup the ions appear to experience very little pitch angle scattering. This may result from strong compression in the rapidly increasing magnetic field.

Goldstein, R.↗

Primary results from the Berkeley EUV airglow rocket spectrometer: O I and N2 FUV/EUV dayglow in the thermosphere and lower exosphere

The Berkeley extreme-ultraviolet airglow rocket spectrometer (BEARS) made spectroscopic measurements of far and extreme UV, atomic oxygen emissions from a Black Brandt XII (12.041 WT) sounding rocket launched from Wallops Island, Virginia, on September 30, 1988. BEARS' primary instrument, a near-normal Rowland mount spectrometer, measured several atomix oxygen and molecular nitrogen dayglow features at high spectral resolution (1.5 A): O I (989, 1027, 1304, and 1356 A); and N2 Lyman-Birge-Hopfield (4, 0) and (3, 0) bands at 1325 and 1354 A. The instrument collected over 800 s of data spanning altitudes of 150 - 963 km with look directions between 95 deg and 125 deg from zenith. We have analyzed the data using electrons and radiative transport models in a forward modeling approach. The model and data are generally in good agreement. However, there are some discrepancies, which are discussed in terms of remote sensing capabilities and improvements to the models.

Cotton, Daniel M.↗

Two-Diffraction-Order, Beam-Splitting, Imaging Spectrometer

Two-octave imaging spectrometer utilizes light of two harmonically related wavelengths diffracted to harmonically related orders at same angles, followed by separation via dichroic beam splitter before final imaging. Conceptual design of spectrometer calls for minimum number of optical elements to achieve coverage of required visible and near-infrared wavelengths in instrument of reduced size, weight, and cost.

Labaw, Clayton C.↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

Telescope With A Two-Color Camera And Two Imaging Spectrometers

Proposed remote-sensing optical instrument system includes two charge-coupled-device (CCD) video cameras sensitive to different colors of light; line-imaging infrared spectrometer; and line-imaging ultraviolet spectrometer; all sharing common telescope foreoptics. Principal advantages: compactness and light weight.

Chrisp, Michael P.↗

A visible-infrared imaging spectrometer for planetary missions

This final report summarizes the design effort for the construction of a visible-infrared imaging spectrometer for planetary missions, funded by NASA under the Planetary Instrument Definition and Development Program. The goal was to design and develop a prototype brassboard pushbroom imaging spectrometer covering the 0.35 gm to 2.5 gm spectral region using a simplified optical layout that would minimize the size, mass and parts count of the instrument by using a single holographic grating to disperse and focus light from a single slit onto both the infrared and visible focal plane arrays. Design approaches are presented and analyzed, along with problems encountered and recommended solutions to those problems. In particular, a new type of grating, incorporating two sets of rulings and a filter in a layered structure, is presented for further development.

McCord, Thomas↗

The Wavelength-Dispersive Spectrometer and Its Proposed Use in the Analytical Electron Microscope

The Analytical Electron Microscope (AEM) equipped with a wavelength-dispersive spectrometer (WDS) should have the ability to resolve peaks which normally overlap in the spectra from an energy-dispersive spectrometer (EDS). With a WDS it should also be possible to measure lower concentrations of elements in thin foils due to the increased peak-to-background ratio compared with EDS. The WDS will measure X-ray from the light elements (4 less than Z less than 1O) more effectively. This paper addresses the possibility of interfacing a compact WDS with a focussing circle of approximately 4 cm to a modem AEM with a high-brightness (field emission) source of electrons.

Goldstein, Joseph I.↗

Observing gamma-ray bursts with the INTEGRAL spectrometer SPI

The spectrometer for INTEGRAL (SPI) is a germanium spectrometer with a wide field of view and will provide the International Gamma Ray Astrophysics Laboratory (INTEGRAL) mission with the opportunity of studying gamma ray bursts. Simulations carried out to assess the response of the instrument using data from real burst data as input are reported on. It is shown that, despite the angular resolution of 3 deg, it is possible to locate the direction of bursts with an accuracy of a few arcmin, while offering the high spectral resolution of the germanium detectors. It is remarked that the SPI field of view is similar to the size of the halo of bursts expected around M 31 on galactic models. The detectability of bursts with such a halo is discussed.

Skinner, G. K.↗

Induced Background in the Mars Observer Gamma-Ray Spectrometer

Gamma-Ray Spectrometers in space must necessarily work in an environment of a background of lines due to natural and cosmic-ray induced radioactivity and lines due to prompt emission following nuclear reactions caused by primary and secondary cosmic rays. The Gamma-Ray Spectrometer (GRS) on the Mar Observer mission has provided important data allowing one to estimate for future missions the extent of the background due to cosmic rays. These data will help in the design of instruments and in calculation of realistic background intensities that may effect the sensitivity of determining the intensity of lines of interest.

Boynton, William V.↗

NEAR Gamma Ray Spectrometer Characterization and Repair

This report covers the work completed in the third year of the contract. The principle activities during this period were (1) the characterization of the NEAR 2 Gamma Ray Spectrometer using a neutron generator to generate complex gamma ray spectra and a large Ge Detecter to identify all the major peaks in the spectra; (2) the evaluation and repair of the Engineering Model Unit of the Gamma Ray Spectrometer for the NEAR mission; (3) the investigation of polycapillary x-ray optics for x-ray detection; and (4) technology transfer from NASA to forensic science.

Groves, Joel Lee↗

Alignment and Polarization Sensitivity Study for the Cassini-Composite InfraRed Spectrometer (CIRS) Far InfraRed (FIR) Interferometer

The Composite InfraRed Spectrometer (CIRS) instrument flying on the Cassini spacecraft to Saturn is a cryogenic spectrometer with far-infrared (FIR) and mid-infrared (MIR) channels. The CIRS FIR channel is a polarizing interferometer that contains three polarizing grid components. These components are an input polarizer, a polarizing beamsplitter, and an output polarizer/analyzer. They consist of a 1.5 micron thick mylar substrate with 2 gm wide copper wires, with 2 gm spacing (4 micron pitch) photolithographically deposited on the substrate. This paper details the polarization sensitivity studies performed on the output polarizer/analyzer, and the alignment sensitivity studies performed on the input polarizer and beamsplitter components in the FIR interferometer.

Crooke, Julie A.↗

Reference Interferometer Using a Semiconductor Laser/LED Reference Source in a Cryogenic Fourier-Transform Spectrometer

A combination of a single mode AlGaAs laser diode and broadband LED was used in a Michelson interferometer to provide reference signals in a Fourier transform spectrometer, the Composite Infrared Spectrometer, on the Cassini mission to Saturn. The narrowband light from the laser produced continuous fringes throughout the travel of the interferometer, which were used to control the velocity of the scan mechanism and to trigger data sampling. The broadband light from the LED produced a burst of fringes at zero path difference, which was used as a fixed position reference. The system, including the sources, the interferometer, and the detectors, was designed to work both at room temperature and instrument operating temperature of 170 Kelvin. One major challenge that was overcome was preservation, from room temperature to 170 K, of alignment sufficient for high modulation of fringes from the broadband source. Another was the shift of the source spectra about 30 nm toward shorter wavelengths upon cooldown.

Martino, Anthony J.↗

Effects of Shear, Defocus, and Wavefront Error on the Theoretical Performance of the Composite Infrared Spectrometer for Cassini

The combined effects on performance of shear between the two arms, defocus of die detector, and difference in wavefront between the two arms of a Fourier transform spectrometer using cube corner retroreflectors were investigated. Performance was characterized by the amplitude of the fringe signals coming from a detector as the path-length difference was scanned. A closed-form expression was found for the combined effects of shear and defocus, and it was found that defocus had no effect in the absence of shear. The effect of wavefront error was modeled numerically and assumed to be independent of shear and defocus. Results were compared with measurements made on the breadboard and engineering model of the Composite Infrared Spectrometer for the Cassini mission to Saturn, and good agreement was found.

Martino, Antonio J.↗

Development of an Atmospheric Pressure Ionization Mass Spectrometer

A commercial atmospheric pressure ionization mass spectrometer (APIMS) was purchased from EXTREL Mass Spectrometry, Inc. (Pittsburgh, PA). Our research objectives were to adapt this instrument and develop techniques for real-time determinations of the concentrations of trace species in the atmosphere. The prototype instrument is capable of making high frequency measurements with no sample preconcentrations. Isotopically labeled standards are used as an internal standard to obtain high precision and to compensate for changes in instrument sensitivity and analyte losses in the sampling manifold as described by Bandy and coworkers. The prototype instrument is capable of being deployed on NASA C130, Electra, P3, and DC8 aircraft. After purchasing and taking delivery by June 1994, we assembled the mass spectrometer, data acquisition, and manifold flow control instrumentation in electronic racks and performed tests.

Source record↗

The Astro-E High Resolution X-Ray Spectrometer

The Astro-E High Resolution X-ray Spectrometer (XRS) was developed jointly by the NASA/Goddard Space Flight Center and the Institute of Space and Astronautical Science in Japan. The instrument is based on a new approach to spectroscopy, the X-ray microcalorimeter. This device senses the energies of individual X-ray photons as heat with extreme precision. A 32 channel array of microcalorimeters is being employed, each with an energy resolution of about 12 eV at 6 keV (the Fe-K region). This will provide spectral resolving power 10 times higher than any other non-dispersive X-ray spectrometer. The instrument incorporates a three stage cooling system capable of operating the array at 60 mK for about two years in orbit. The array sits at the focus of a grazing incidence conical mirror. The quantum efficiency of the microcalorimeters and the reflectivity of the X-ray mirror system combine to give high throughput over the 0.3-12 keV energy band. This new capability will enable the study of a wide range of high-energy astrophysical sources with unprecedented spectral sensitivity. This paper presents the basic design requirements and implementation of the XRS, and also describes the instrument parameters and performance.

Kelley, Richard L.↗

Deep Atmosphere Ammonia Mixing Ratio at Jupiter from the Galileo Probe Mass Spectrometer

New laboratory studies employing the Engineering Unit (EU) of the Galileo Probe Mass Spectrometer (GPMS) have resulted in a substantial reduction in the previously reported upper limit on the ammonia mixing ratio derived from the GPMS experiment at Jupiter. This measurement is complicated by background ammonia contributions in the GPMS during direct atmospheric sampling produced from the preceding gas enrichment experiments. These backgrounds can be quantified with the data from the EU studies when they are carried out in a manner that duplicates the descent profile of pressure and enrichment cell loading. This background is due to the tendency of ammonia to interact strongly with the walls of the mass spectrometer and on release to contribute to the gas being directly directed into the ion source from the atmosphere through a capillary pressure reduction leak. It is evident from the GPMS and other observations that the mixing ratio of ammonia at Jupiter reaches the deep atmosphere value at substantially higher pressures than previously assumed. This is a likely explanation for the previously perceived discrepancy between ammonia values derived from ground based microwave observations and those obtained from attenuation of the Galileo Probe radio signal.

Mahaffy, P. R.↗

Miniature Time-of-Flight Mass Spectrometer

Major advances must occur to protect astronauts from prolonged periods in near-zero gravity and high radiation associated with extended space travel. The dangers of living in space must be thoroughly understood and methods developed to reverse those effects that cannot be avoided. Six of the seven research teams established by the National Space Biomedical Research Institute (NSBRI) are studying biomedical factors for prolonged space travel to deliver effective countermeasures. To develop effective countermeasures, each of these teams require identification of and quantitation of complex pharmacological, hormonal, and growth factor compounds (biomarkers) in humans and in experimental animals to develop an in-depth knowledge of the physiological changes associated with space travel. At present, identification of each biomarker requires a separate protocol. Many of these procedures are complicated and the identification of each biomarker requires a separate protocol and associated laboratory equipment. To carry all of this equipment and chemicals on a spacecraft would require a complex clinical laboratory; and it would occupy much of the astronauts time. What is needed is a small, efficient, broadband medical diagnostic instrument to rapidly identify important biomarkers for human space exploration. The Miniature Time-Of- Flight Mass Spectrometer Project in the Technology Development Team is developing a small, high resolution, time-of-flight mass spectrometer (TOFMS) to quantitatively measure biomarkers for human space exploration. Virtues of the JHU/APL TOFMS technologies reside in the promise for a small (less than one cubic ft), lightweight (less than 5 kg), low-power (less than 50 watts), rugged device that can be used continuously with advanced signal processing diagnostics. To date, the JHU/APL program has demonstrated mass capability from under 100 to beyond 10,000 atomic mass units (amu) in a very small, low power prototype for biological analysis. Further, the electronic nature of the TOFMS output makes it ideal for rapid telemetry to earth for in-depth analysis by ground support teams.

Potember, Richard S.↗